2002-462 TOVN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804.5902 (518)761.8201
Community Development.Building&Codes (518)761-8256
P TIFICATE 'V".r'Uft-n—L
E
PennitNumber. P20020462 Date Issued; Friday,February 01,2008
This is to ceftiif that work requested to be done as shown by Permit Number P20020462
has been completed.
Tax Map Number. 523400-301-008-0001-069-000-0000
Location; 59 HELEN Dr
Owner. JOHN&CYNTHIA HORGAN
Applicant: JOHN&CYNTHIA HORGAN
This structure maybe occupied as a:
Porch
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20020462 Application Number: A20020462
Tax Map No: 523400-301-008-0001-069-000-0000
Permission is hereby granted to: JOHN& CYNTHIA HORGAN
For property located at: 59 FIELEN Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. TWe of Construction Value
Owner Address: JOHN& CYNTHIA HORGAN Porch $5,000.00
59 HELEN Dr QUEENSBURY, NY 12804 Total Value $5,000.00
Contractor or Builder's Name Address Electrical Inspection Agency
Plans&Specifications
2002-462
244 SQ FT PORCH AS PER PLOT PLAN SPECIFICATIONS
SENDING CK FOR 25.00 RENEWAL. CHG ENPIRATIONTO 6/12/05
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,June 12, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T June 12, 2002
SIGNED BY zz!� for the Town of Queensbury.
V '%Q
Director of Building&Code Enforcement
I '
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT -
Permit Number: ., P20020462 Application Number: A20020462
Tax Map No: 523400-301-008-0001-069-000-0000
Permission is hereby granted to: JOHN& C;YNTNTA HC)RGAN
For property located at: 59 HELEN Or
f,
in the Town of Queensbury,to constrictor place i
at.the above location in accordance with application together with.plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Ty0e of Construction Value
Owner Address: 70HN& CYNTHIA HORGAN
59 HELEN Dr Porch $5,000.00"
Total Value $5,000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
{k
i
Plans&Specifications
2002 462 close out p`ertnit�7/14145 as Mrs`T"Horgan'Wig reapply at a later-date. ,
244 SQ FT PORCH AS PER PLOT PLAN SPECIFICAF N--
SENDING CK FOR 25.00 RENEWAL. CHG E3TIRATIONTO 6/12/05
$40,46 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, June 12, 2005
(If a longer period is required,an application for an extension must Ue made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.) '
Dated at a To Lofe ury nesday, June 12, 2002
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
t
�- TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
I
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20020462 Application Number: A20020462
Tax Map No: 523400-301-008-0001-069-000-0000
Permission is hereby granted to: JOHN & CYNTHIA MORGAN
For property located at: 59 HELEN Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JOHN,& CYNTHIA HORGAN
59IELEN Dr Porch 5,000.00
Total Value 5,000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2002-462
244 SQ FT PORCH AS PER PLOT PLAN SPECIFICATIONS
$40.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,June 12,2003
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at a To �fl
ury; esday,June 12,2002
SIGNED BY for the Town of Queensbury.
r
Director of Building&Code Enforcement
TOWN OF QUEENSBQRY � RECEENED , Fee Paid - -:Q
;BUILDING & CODES DEPARTMENT Permit # -ipG
:APPLICATION FOR PORCHES-DECKS-J UNV O 3 2002
DOCKS & BOATHOUSES . Est. CosTOWN OF QUEENSBURY
11tly�"
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CON ST M '-MI (`19 —WN"WER -ALL OF Tf1E FOLiLOWING:
The undersigned hereby applies for a Building Permit to do the following work which will be {`
done in accordance With the description, plans and specifications submitted, and such;specia'l
conditions -T
,as may be indicated on the permit, WO-SETS OF.STRUCTURAL PLANS S11ALL BE SUBMITTED
WITH THIS APPL-ICATION.
t
Owner, of Property: - ~��� •� �y }, '} �}
P.O. Address ISc1 \AE.1"EA.3 DO)N-\IJE Phone # `-71:71 -,0-7I -7
Property' Location t3�sn�/ }-.]� 1�C> Tax Map ,#
Subdivision Name (If applicable) - E1)Eq_(>6 aLA,7
PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES:
Name: !,OAN VA -,tam Address Phone# ?61-0)
is ` BUILDING SPECIFICATIONS:
Type of1,work 'to be done: orch . Deck Dock Boathouse (Circle one)
r , a�
Size of;'Structure to be -bui 7 t (..square footage): i 3 -10 �(� r t,�
Foundation Material : Width thickness f T� "1
Depth of Footing, below grader
Size of Posts or Studs:. x x Long,"
Size 'of Floor Joists x x Span
Decking or Flooring Material :; .
How will Porch or Deck be fastened to building?
If Roof Will Be Installed, Answer -Following_ Questions:
Size of Posts' or Studs: x. x Long
Roof Rafters:, x Spacing Span
Roof- Trusses ;(pre-engineered spacing): Span -
Type of;,Roof:' Sloped Flat Shed Other (Circle one)
Material of Roof:
ZONING- INFORMATION:
TWO PLOT PLANS MUST BE PREPARED-AND SUBMITTED;- drawn reasonably to scale .and attached
hereto, showing clearly and distinctly.-all bu d ngs, whether existing or proposed and
` indicate all set back -dimensions from property lines. Show location of water supply and
location ,and configuration .of septic disposal area.
Size of Property:. i t�`l ft. x ) ft.
Exi;sting ,building(s): Size .,a-6 ft, x 45 ft_
Size ft. x ft. ,
Use of Existing building(s): tt
Proposed structure, distance from property line.: I
Front yard ft. Rear yard ft. ' f
Side yards . ft. and ft'.
If -on corner, setback from side street:' ft.
-DECLARATION
To the best of my knowledge and..belief the statements 'contatned .in this 'applicati.00,
,together with the plans and specifications submitted, are a' true and complete statement
of all proposed workt 'to be done on the described premises and that all provisions of the
Building Code, ..the Zoning. Ordinance, and all other 'laws pertaining to the proposed work
shall be complied wi-th, whether specified or not, and that such work is authori,zed_ by .the
owner.
DATE: SIGNATURE J --
Own� r Owner's Agenc c ct, ntractor
REVIEWED' BY CODE ENFORCEMENT OFFICER, DATE-. SIGNATURE �.� _
Queensbury Building & Code Enforcement - Residential Final Inspection
e No.(518)761-8256 Arrive: am/p epart, am/pm
Inspection request received: _ Inspector's Initials:
E: 14oma PERMIT
CATION: r-' DATE:
VPE OF STRUCTURE:
(,7 Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom: f
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft,vents �(
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
`
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Tenip 110
Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\R.esidential Final Inspection Form revised_l00405.doc
COMMONWEALTH ELECTRICAL INSPECTION SERVICE, INC.
Main Office 176 Doe Run Road - Manhelm, PA 1754
MUNICIPAL CERTIFICATE , ELECTRICAL APPROVAL
�Per#No•iiiiilfittif i#tiiii#It#il#iliit#i tii���} * Cut-in Bard
itt{i IR if#i{Ni !ii#!#iH#Niil{ii}fMi11#IffirNifiifflffHfi}iiff ii!!t fii fif ii}f itl fif! ffiitffiffllf lffif ffififlplgNfif
Cy
Locaft'on,,,,fa,,,,,1a4,,#401.4rom}ffl}f{}i!lffir!!NIDowlilfRifliMi#flttifpiNi11RliiilliNNNIIif#!#ilNNRNlRI/I#####!I##NIif##4140ams q}tfliNlN###
7�/
Installation Consisting of... ###}i Niififiiffi IiiRi # ui#N/iit#f ififNiff lff#Naf/a1#M##ii#INN##HufRiauflttfififfiii
iHiN1N##IIq#NtfN}iftigftibitifr/figfuNlFNiNfif f Irlf!lloiuiftiRuflNftfifurf!#fiufilNitliiililNlN##i1i.NfRi#{INtpiiifiiNRlNilo1##IlNi##i1i#fNNlNtfiuu}
tMfffffiloiloi $1I#iitli*#00i4 iiff0Rt.fifolii#i}#Hi}tiittilflNt#f};fN1lffIN.NiftitIIIl/#i#f Ito afirrfiitN#N}lofts lrritsetr lot!i#ib}ti#IIIlffiif Matta ff414#00 iitf06i440
1
Installedf 1i1#i!i}fii##4���t1YY#I1��1"'1i#illiifEi tilii ali#itiiNififfiiiftiiNiai}iaia a#fi05F }}tt}fatarfftiifffN L+ca Not if#firtfrratiiii ii#iiaiif/ftiitffirfftfff tftftaff
The conditions following governed the issuance of this certilkate, and any certificate previously issued is
cancelled.
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations, application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of mkin inspections at any time, and if its
rules are violated, the Company shall have the right to a lie hi ce fic !
Date �'
tlo# IIIiilloi. !t##i Nf nfttNfittlNNNfii INSPECTOR fiilati iffiiiiill r#1iNiloINNNiffISMII1#}iiI#l/liiffi{fiti $III fffloNNflNilitI
Member N.F.P.A..I.A1411
Queensbury Building & Code Enforc 9'ni t -Vesidefiffa-lTin' al-lfispectic�n�
I
0 'e No.(518)761-8256 Arrive: am/pm Depart: am/pm
Da a inspection request received: Inspector's Initials: A g A
NAME: 1---- PERMIT#:
LOCATION: . DATE:
TYPE OF STRUCTURE:
Commen s
Yes No N/A
Building Number/'Address visible from road
Chimney Height I"•B"Vent/Direct Vent Location
Fresh Air Intake NZ C;
3 inch PlumbingVent through roof minimum 6 inches � �
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
�� ..----_
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more ;
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall j
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade J r
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing_/Window in stairwells safety glazingZ
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside_every bedroom area:
Inter Connected Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures'
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within:30 feet or within line of site tf
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater'o eratin
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%s"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas o s.in-$_sled or Glass Enclosure
Final Electrical
Fina urve Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certif cation,if required
Okay to issue C I C or C/O Tem or /Permanent
LABuilding&Codes FormslBuilding&Codesllnspection Forms\Residential Final Inspection Form revised 100405.doc
.� Town of 44 eesbury hie Mai rsbal
742 BAy Road
Queensbury,NY 12804
761-8205'1761-8206
fax 745-4437
'tt9gry Suitt Gas Firenlaee/Stove Inspection Report
Notices New York State requires that all UL Listed,factory built appliances be installed according to.the instructions and
specifications contained in the histallation manual accompanying the,appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# _ l Schedule In ection 1�' Time ��� m anytime J[nspector
Address_m >� � I13T,� �. k2ough In3inal
Appliance 111anufact�xrex _ _Model#
Direct Vent Al factory.built Chinuley Flue Sire Double Wall Triple Walt Insulated
Yes No N/A, ; Comments
Floor Protection
i.
Clearances to Combustibles (all sides)
Firestop(s) vertical chase,
wall Penetration...d- `
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible 1
construction within 10 feet j
Gas Shut-Off Valve
Combustion Air
r
Hearth]Extension.(if any)
Mantel V
Height above f/p opening,
Witness Operation
Tank Placement Cif LP)
White—BuIMIng Dept. . .A � w.p M. 1'M w r Pink--Rro MarAd
Rough Plumbing /.,Insul 61tion Inspection Report
Office No. (518) 761-8256 Date Inspection request received: 10 1-7 0
Queensbury Building &Code Enforcement Arrive:, am/pm Depart. 36 am/pm
742 Bay Road, Queensbury, NY 12804 Inspector`s Initials: `
NAME: �" �` �� PERMIT #:
LOCATION: INSPECT ON: L&L16
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbin / Nall Plates
Plumbing Vent Vents in Place
1 1l2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 PS.I for 15 minutes 1010,
,--ftrs-uraffl-io-D Residential Check Commercial Check
ro er Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air:Supply for Furnace
Duct work sealed properly / No duct tape 77
COMMENTS: Y
Z'k
LAPam Whiting�Building&CodesMnspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing/ Firestoppin� Ifispection Report
9.
Office No.(518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive. ____am/yn e art: I am/pm
,742 Bay Road,Queensbury,NY 12804 Inspector's Initials' f,
PER A62
NAME:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE.,
Framing COMMENTS
��--ic -�cce s 22"x 30"minimum
Jack Studs Headers
Bracing Bridging
Joist hangers
Jack Posts/Main Beams <
Exterior sheeting nailed properly
IT,O.C.
Headroom 6 ft. 8 in. Y.
Stairwells 36 in.or more
Headroom 6 ft. 8 in.
Note i Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I Y2(w) 16 gauge(8),1,6D nails each side
Draft stopping 1,000 sq. ft.floor trusses
Anci or less on center
Ice and water shield 2 inches from wall
11�re-�separ4tion 1,2,-3 hour J
Fire wall 2., 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min-_
Garage Fire Separation
House side Y2inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
-Windows Habitable Space Bedrooms
24 in.(H)
20 in.(W)
5.7 sf above below grade
5.0 sf grade
-3 MOP DAII"T 10116106
Framing / Firestopping Inspection Report ,
Office No.(518) 761-8256 Date Inspection request received:
Queensbiuy Building&Code Enforcement Arrive., am/M�C
a Depart: ?Y�am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: 152 7462 .
LOCATION: Mk-t,-, b ri e INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COM MENTS
Attic Access 22"x 30"minimum
Jack Studs Headers
Bracing Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft.8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2,3 hour
Fi 112 3,4 hour
Firestoppini
Pen—effr—af ion sealed
16 inch insulation in cavity min.
Garage Fire Separation
.House side V2inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilinewall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5,0 sf grade
V
Office Use
GENERAL INSPECTION REPORT Inspector:
t time:Ready at
Town of Queensbury
Dept. of Community Development Request received. Meet:
Building& Code Enforcement At time:
742 Bay Road
Queensbury, AT 12804 ARRIVE am/pm; DEPARTZ - am/pm Notes:
(518) 761-8256. Inspector's Initials v}
NAME: PERMIT# '
LOCATION: t 59 INSPECT ON(date):
TYPE OF STRUCTURE: .
RECHECK
N/A YES NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
Foundation/Wallpour
Reinforcement in Place
Ilu
mdation/DampproofmgkfillApprovalmbing Under Slab 1
Plumbing Vent/Vents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R
Floors R
Walls R-
ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
raming
Jack Studs/Headers
Bracing/Bridging.-
Joist Hangers
Jack Posts/Main Beain
Air Infiltration Barrier
Fire Separation 1,42,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping
L:\.SueHemingway\Building.Codes.Inspection.FORMSIGENERAL INSPECTION REPORT.doc
Office Use
GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time:
Dept. of Community Development Request received: Meet:
Building& Code Enforcement At time:
742 Bay Road
Queensbury, AT 12804 ARRIVE a T rCa M9 "Notes:
(518) 761-8256 Inspector's Initial
NAME: %A%�� PERMIT# 2 -C)C)7- 4(a�
LOCATION: HELEO INSPECT ON(date):
TYPE OF STRUCTURE. (11.V----0-T-ogy== Povc-\A) \/-)L4R 16 Rt FC)OV\
RECHECK
JFootings/Piers N/A YES COMMENTS
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
'e
P
PERMIT"T"4,
ateiials for this purpose on site
tititiJJJFoundation/Wallpour L— R
Reinforcement in Place
)toundation/Dampprooflng— —�7z I-'Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
ough Plumbing
—
eating Rough-In
Insulation
V/
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridgmig—
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopplug—
L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc
S t I
y � �
CL ?�: � e /
tit P
G r'�,v/,91g1, y ?i � t^m h�' � a, r• .9,,. r 1 / (�\\V' �
41
rZ I i
73
�t�',-.-
,`�^Y xa +�'sy•' ?f%"'ity�Gj�y� �/ � �\.`.. 71' �D� /� °r ¢� (
C'F
LJ
-ZF ?'\. /\ �., Q g `,.\ i,(� rr� lE ..�. ,t,._...,�' / r ✓i r r
f n A£.£F'./v
,,� �;-%S _ "L( Yoh `',<, �j�'t'r�' // � � i/ `� ��,�•(� r {
44
sL ul�/C�n�`"M1 � h� c�� •a��'r r 1�9 a / rr / � Qx�
I / � 6i
Nil
� 2� �� � •� :I: ��. : �B�o��LN .�J� �a'u .r\\ ���`�;. 11 /< .'a'. 8_ �� � r 4 �,// � arm
IIIF
� m
lot
' U) _J -"' � � " 6 �.fa � . _ �Gi I r � ;��C\O•,4, r, •/i _\ ��5��'+`s®�r'��� "'/f`� �:YSk �i� 4- t� `,r-�r \\
!
_s''
5 � ' to £gip\+ `Y-r i i /roSS d^ '�' \`. I NP .�`•' knit
.
a 1so r T /k...+c✓. I M o'-' ` "s' rs;
S a \,}
sAve i,�, > °'A�dY s 'h�i `-�f v �;':• 'e sir . AA,,yy _ /
1A '%'
y /
.9 m�`;I'- rrl a—_,_.__ .-_._ .i 4-3k'�'� #-- �i"' '/�G/l/.G .r \ `'. ,�.i' `��� \, *,.'ax4 TSY / V• �11.. �r, \'S���..�yF'`/' .. \-s .\
RIGHT ELEVATION
SCALE: 1/4" - 1'-0"
ROOF MATERIAL
RIDGE VENT - NOT SHOWN
SHINGLES TO MATCH EXISTING
150 ROOFING FELT
5/8" OSB SHEATHING
2 x 10 RAFTERS 1 16" O.C.
8" (R-30) NI-PERF. FG INSULATION
PROPER VENT FOR AIR FLOW TO RIDGE
1 x 6 T4G V-JOINT PINE CEILING
(2) 1-3/4" x 14" LVL RIDGE
BEAM WITH PINE TRIM
SAVE MATERIAL
METAL DRIP EDGE
ICE t WATER SHIELD • EAVES
ALUMINUM FASCIA
2 X 6 "FASCIA
VENTED VINYL SOFFIT
WALL MATERIAL
DOUBLE-4 VINYL SIDING
TYVEK OR EQUAL BARRIER
1/2" OSB SHEATHING
2 X 4 STUDS • 16" O.C.
3-1/2" (R-15) FG INSULATION
POLY VAPOR BARRIER
GYP. WALL BOARD
FOUNDATION MATERIAL
STAMPED CONC SLAB FLOOR
8" POURED CONC. FROST WALL
2" RIGID FOAM INSULATION
CROSS SECTION
SCALE: 1/4" - 1'-0"
PROVIDE ANCHOR BOLTS
S' 0/C MAX AND 12" FROM
CORNERS AND JOINTS
UNEXCAVATED
STAMPED CONCRETE
FLOOR W/ RIGID INSUL.
8" POURED CONCRETE
FROST WALL
014'-0" Fek.ezir
FOUNDATION PLAN
SCALE, 1/4" 1'-0"
EXISTING
FAMILY ROOM
OPY
LEFT ELEVATION T{ C - - c� *E'ENE ;j -/ "U;t. NG DEPARTMENT
~sawed on our l;rnited examination,
SCALE: 1/4" ■ 1'-0" compliance with our comments shall
not be construed as indicating the
plans and specifications are in full
compliance with the code,
T014VN OF Q1.1�L�-.�`�`° ...;fir
BUILDING %n'T"
REVIEWED BYDATE /„
GARAGE
DOOR LOCATION Z
�. . 1
•
SUNROOM I
STAMPED vE11oc F6-106
L-dSKYLIG44TS
_
CONCREiE
1�
Q
I
�
fie
'
• Cr sloped I CrI e111g
1 n
A
.• 0 d I
CUSTOM CUSTOM
y FIXED I FIXED
2062 2 2062-2
4'-4" 61-514" 41-4" 6'-514"
4'-2" 51-8"
13�-a 14'-0"
FLOOR PLAN
SCALE: 1/4" - 1'-0"
Midnight
Oil
.Design
Ashton (AK) Hayes III
297 Ridge Street
Glens Falls, New York
(518) 792 - 7173
akiii@yahoo.com
0
Y
l
a
o
Zi
o��
�o
U
-71
z
0
A
Q
lu
d
cc)
Job No.: - 2002-03
Q Dwn By: AK Hayes
Date: 04/07/2002
Scale: As Noted
Revisions:
Sheet:
e E'V
D
JUN 0 3 �0 /
roW,V D,t