2002-462 TOVN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804.5902 (518)761.8201 Community Development.Building&Codes (518)761-8256 P TIFICATE 'V".r'Uft-n—L E PennitNumber. P20020462 Date Issued; Friday,February 01,2008 This is to ceftiif that work requested to be done as shown by Permit Number P20020462 has been completed. Tax Map Number. 523400-301-008-0001-069-000-0000 Location; 59 HELEN Dr Owner. JOHN&CYNTHIA HORGAN Applicant: JOHN&CYNTHIA HORGAN This structure maybe occupied as a: Porch By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020462 Application Number: A20020462 Tax Map No: 523400-301-008-0001-069-000-0000 Permission is hereby granted to: JOHN& CYNTHIA HORGAN For property located at: 59 FIELEN Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. TWe of Construction Value Owner Address: JOHN& CYNTHIA HORGAN Porch $5,000.00 59 HELEN Dr QUEENSBURY, NY 12804 Total Value $5,000.00 Contractor or Builder's Name Address Electrical Inspection Agency Plans&Specifications 2002-462 244 SQ FT PORCH AS PER PLOT PLAN SPECIFICATIONS SENDING CK FOR 25.00 RENEWAL. CHG ENPIRATIONTO 6/12/05 $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,June 12, 2007 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T June 12, 2002 SIGNED BY zz!� for the Town of Queensbury. V '%Q Director of Building&Code Enforcement I ' TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT - Permit Number: ., P20020462 Application Number: A20020462 Tax Map No: 523400-301-008-0001-069-000-0000 Permission is hereby granted to: JOHN& C;YNTNTA HC)RGAN For property located at: 59 HELEN Or f, in the Town of Queensbury,to constrictor place i at.the above location in accordance with application together with.plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Ty0e of Construction Value Owner Address: 70HN& CYNTHIA HORGAN 59 HELEN Dr Porch $5,000.00" Total Value $5,000.00 QUEENSBURY,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency {k i Plans&Specifications 2002 462 close out p`ertnit�7/14145 as Mrs`T"Horgan'Wig reapply at a later-date. , 244 SQ FT PORCH AS PER PLOT PLAN SPECIFICAF N-- SENDING CK FOR 25.00 RENEWAL. CHG E3TIRATIONTO 6/12/05 $40,46 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, June 12, 2005 (If a longer period is required,an application for an extension must Ue made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) ' Dated at a To Lofe ury nesday, June 12, 2002 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement t �- TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 I Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020462 Application Number: A20020462 Tax Map No: 523400-301-008-0001-069-000-0000 Permission is hereby granted to: JOHN & CYNTHIA MORGAN For property located at: 59 HELEN Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOHN,& CYNTHIA HORGAN 59IELEN Dr Porch 5,000.00 Total Value 5,000.00 QUEENSBURY,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2002-462 244 SQ FT PORCH AS PER PLOT PLAN SPECIFICATIONS $40.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,June 12,2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at a To �fl ury; esday,June 12,2002 SIGNED BY for the Town of Queensbury. r Director of Building&Code Enforcement TOWN OF QUEENSBQRY � RECEENED , Fee Paid - -:Q ;BUILDING & CODES DEPARTMENT Permit # -ipG :APPLICATION FOR PORCHES-DECKS-J UNV O 3 2002 DOCKS & BOATHOUSES . Est. CosTOWN OF QUEENSBURY 11tly�" A PERMIT MUST BE OBTAINED BEFORE BEGINNING CON ST M '-MI (`19 —WN"WER -ALL OF Tf1E FOLiLOWING: The undersigned hereby applies for a Building Permit to do the following work which will be {` done in accordance With the description, plans and specifications submitted, and such;specia'l conditions -T ,as may be indicated on the permit, WO-SETS OF.STRUCTURAL PLANS S11ALL BE SUBMITTED WITH THIS APPL-ICATION. t Owner, of Property: - ~��� •� �y }, '} �} P.O. Address ISc1 \AE.1"EA.3 DO)N-\IJE Phone # `-71:71 -,0-7I -7 Property' Location t3�sn�/ }-.]� 1�C> Tax Map ,# Subdivision Name (If applicable) - E1)Eq_(>6 aLA,7 PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: Name: !,OAN VA -,tam Address Phone# ?61-0) is ` BUILDING SPECIFICATIONS: Type of1,work 'to be done: orch . Deck Dock Boathouse (Circle one) r , a� Size of;'Structure to be -bui 7 t (..square footage): i 3 -10 �(� r t,� Foundation Material : Width thickness f T� "1 Depth of Footing, below grader Size of Posts or Studs:. x x Long," Size 'of Floor Joists x x Span Decking or Flooring Material :; . How will Porch or Deck be fastened to building? If Roof Will Be Installed, Answer -Following_ Questions: Size of Posts' or Studs: x. x Long Roof Rafters:, x Spacing Span Roof- Trusses ;(pre-engineered spacing): Span - Type of;,Roof:' Sloped Flat Shed Other (Circle one) Material of Roof: ZONING- INFORMATION: TWO PLOT PLANS MUST BE PREPARED-AND SUBMITTED;- drawn reasonably to scale .and attached hereto, showing clearly and distinctly.-all bu d ngs, whether existing or proposed and ` indicate all set back -dimensions from property lines. Show location of water supply and location ,and configuration .of septic disposal area. Size of Property:. i t�`l ft. x ) ft. Exi;sting ,building(s): Size .,a-6 ft, x 45 ft_ Size ft. x ft. , Use of Existing building(s): tt Proposed structure, distance from property line.: I Front yard ft. Rear yard ft. ' f Side yards . ft. and ft'. If -on corner, setback from side street:' ft. -DECLARATION To the best of my knowledge and..belief the statements 'contatned .in this 'applicati.00, ,together with the plans and specifications submitted, are a' true and complete statement of all proposed workt 'to be done on the described premises and that all provisions of the Building Code, ..the Zoning. Ordinance, and all other 'laws pertaining to the proposed work shall be complied wi-th, whether specified or not, and that such work is authori,zed_ by .the owner. DATE: SIGNATURE J -- Own� r Owner's Agenc c ct, ntractor REVIEWED' BY CODE ENFORCEMENT OFFICER, DATE-. SIGNATURE �.� _ Queensbury Building & Code Enforcement - Residential Final Inspection e No.(518)761-8256 Arrive: am/p epart, am/pm Inspection request received: _ Inspector's Initials: E: 14oma PERMIT CATION: r-' DATE: VPE OF STRUCTURE: (,7 Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: f Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft,vents �( Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating ` Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tenip 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\R.esidential Final Inspection Form revised_l00405.doc COMMONWEALTH ELECTRICAL INSPECTION SERVICE, INC. Main Office 176 Doe Run Road - Manhelm, PA 1754 MUNICIPAL CERTIFICATE , ELECTRICAL APPROVAL �Per#No•iiiiilfittif i#tiiii#It#il#iliit#i tii���} * Cut-in Bard itt{i IR if#i{Ni !ii#!#iH#Niil{ii}fMi11#IffirNifiifflffHfi}iiff ii!!t fii fif ii}f itl fif! ffiitffiffllf lffif ffififlplgNfif Cy Locaft'on,,,,fa,,,,,1a4,,#401.4rom}ffl}f{}i!lffir!!NIDowlilfRifliMi#flttifpiNi11RliiilliNNNIIif#!#ilNNRNlRI/I#####!I##NIif##4140ams q}tfliNlN### 7�/ Installation Consisting of... ###}i Niififiiffi IiiRi # ui#N/iit#f ififNiff lff#Naf/a1#M##ii#INN##HufRiauflttfififfiii iHiN1N##IIq#NtfN}iftigftibitifr/figfuNlFNiNfif f Irlf!lloiuiftiRuflNftfifurf!#fiufilNitliiililNlN##i1i.NfRi#{INtpiiifiiNRlNilo1##IlNi##i1i#fNNlNtfiuu} tMfffffiloiloi $1I#iitli*#00i4 iiff0Rt.fifolii#i}#Hi}tiittilflNt#f};fN1lffIN.NiftitIIIl/#i#f Ito afirrfiitN#N}lofts lrritsetr lot!i#ib}ti#IIIlffiif Matta ff414#00 iitf06i440 1 Installedf 1i1#i!i}fii##4���t1YY#I1��1"'1i#illiifEi tilii ali#itiiNififfiiiftiiNiai}iaia a#fi05F }}tt}fatarfftiifffN L+ca Not if#firtfrratiiii ii#iiaiif/ftiitffirfftfff tftftaff The conditions following governed the issuance of this certilkate, and any certificate previously issued is cancelled. This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations, application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of mkin inspections at any time, and if its rules are violated, the Company shall have the right to a lie hi ce fic ! Date �' tlo# IIIiilloi. !t##i Nf nfttNfittlNNNfii INSPECTOR fiilati iffiiiiill r#1iNiloINNNiffISMII1#}iiI#l/liiffi{fiti $III fffloNNflNilitI Member N.F.P.A..I.A1411 Queensbury Building & Code Enforc 9'ni t -Vesidefiffa-lTin' al-lfispectic�n� I 0 'e No.(518)761-8256 Arrive: am/pm Depart: am/pm Da a inspection request received: Inspector's Initials: A g A NAME: 1---- PERMIT#: LOCATION: . DATE: TYPE OF STRUCTURE: Commen s Yes No N/A Building Number/'Address visible from road Chimney Height I"•B"Vent/Direct Vent Location Fresh Air Intake NZ C; 3 inch PlumbingVent through roof minimum 6 inches � � Roof Complete/Exterior Finish Complete Platform at all exterior doors �� ..----_ Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more ; Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall j Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade J r Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing_/Window in stairwells safety glazingZ Interior Smoke Detectors: Every level: Every Bedroom: Outside_every bedroom area: Inter Connected Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures' Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within:30 feet or within line of site tf Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater'o eratin Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%s"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas o s.in-$_sled or Glass Enclosure Final Electrical Fina urve Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certif cation,if required Okay to issue C I C or C/O Tem or /Permanent LABuilding&Codes FormslBuilding&Codesllnspection Forms\Residential Final Inspection Form revised 100405.doc .� Town of 44 eesbury hie Mai rsbal 742 BAy Road Queensbury,NY 12804 761-8205'1761-8206 fax 745-4437 'tt9gry Suitt Gas Firenlaee/Stove Inspection Report Notices New York State requires that all UL Listed,factory built appliances be installed according to.the instructions and specifications contained in the histallation manual accompanying the,appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# _ l Schedule In ection 1�' Time ��� m anytime J[nspector Address_m >� � I13T,� �. k2ough In3inal Appliance 111anufact�xrex _ _Model# Direct Vent Al factory.built Chinuley Flue Sire Double Wall Triple Walt Insulated Yes No N/A, ; Comments Floor Protection i. Clearances to Combustibles (all sides) Firestop(s) vertical chase, wall Penetration...d- ` Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible 1 construction within 10 feet j Gas Shut-Off Valve Combustion Air r Hearth]Extension.(if any) Mantel V Height above f/p opening, Witness Operation Tank Placement Cif LP) White—BuIMIng Dept. . .A � w.p M. 1'M w r Pink--Rro MarAd Rough Plumbing /.,Insul 61tion Inspection Report Office No. (518) 761-8256 Date Inspection request received: 10 1-7 0 Queensbury Building &Code Enforcement Arrive:, am/pm Depart. 36 am/pm 742 Bay Road, Queensbury, NY 12804 Inspector`s Initials: ` NAME: �" �` �� PERMIT #: LOCATION: INSPECT ON: L&L16 TYPE OF STRUCTURE: Y N N/A Rough Plumbin / Nall Plates Plumbing Vent Vents in Place 1 1l2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 PS.I for 15 minutes 1010, ,--ftrs-uraffl-io-D Residential Check Commercial Check ro er Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air:Supply for Furnace Duct work sealed properly / No duct tape 77 COMMENTS: Y Z'k LAPam Whiting�Building&CodesMnspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing/ Firestoppin� Ifispection Report 9. Office No.(518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive. ____am/yn e art: I am/pm ,742 Bay Road,Queensbury,NY 12804 Inspector's Initials' f, PER A62 NAME: LOCATION: INSPECT ON: TYPE OF STRUCTURE., Framing COMMENTS ��--ic -�cce s 22"x 30"minimum Jack Studs Headers Bracing Bridging Joist hangers Jack Posts/Main Beams < Exterior sheeting nailed properly IT,O.C. Headroom 6 ft. 8 in. Y. Stairwells 36 in.or more Headroom 6 ft. 8 in. Note i Holes/Bearing Walls Metal Strapping for Notches Top Plate I Y2(w) 16 gauge(8),1,6D nails each side Draft stopping 1,000 sq. ft.floor trusses Anci or less on center Ice and water shield 2 inches from wall 11�re-�separ4tion 1,2,-3 hour J Fire wall 2., 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min-_ Garage Fire Separation House side Y2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall -Windows Habitable Space Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above below grade 5.0 sf grade -3 MOP DAII"T 10116106 Framing / Firestopping Inspection Report , Office No.(518) 761-8256 Date Inspection request received: Queensbiuy Building&Code Enforcement Arrive., am/M�C a Depart: ?Y�am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: 152 7462 . LOCATION: Mk-t,-, b ri e INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COM MENTS Attic Access 22"x 30"minimum Jack Studs Headers Bracing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fi 112 3,4 hour Firestoppini Pen—effr—af ion sealed 16 inch insulation in cavity min. Garage Fire Separation .House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilinewall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5,0 sf grade V Office Use GENERAL INSPECTION REPORT Inspector: t time:Ready at Town of Queensbury Dept. of Community Development Request received. Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE am/pm; DEPARTZ - am/pm Notes: (518) 761-8256. Inspector's Initials v} NAME: PERMIT# ' LOCATION: t 59 INSPECT ON(date): TYPE OF STRUCTURE: . RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Ilu mdation/DampproofmgkfillApprovalmbing Under Slab 1 Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R Floors R Walls R- ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent raming Jack Studs/Headers Bracing/Bridging.- Joist Hangers Jack Posts/Main Beain Air Infiltration Barrier Fire Separation 1,42,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\.SueHemingway\Building.Codes.Inspection.FORMSIGENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE a T rCa M9 "Notes: (518) 761-8256 Inspector's Initial NAME: %A%�� PERMIT# 2 -C)C)7- 4(a� LOCATION: HELEO INSPECT ON(date): TYPE OF STRUCTURE. (11.V----0-T-ogy== Povc-\A) \/-)L4R 16 Rt FC)OV\ RECHECK JFootings/Piers N/A YES COMMENTS Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. 'e P PERMIT"T"4, ateiials for this purpose on site tititiJJJFoundation/Wallpour L— R Reinforcement in Place )toundation/Dampprooflng— —�7z I-'Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place ough Plumbing — eating Rough-In Insulation V/ Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig— Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopplug— L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc S t I y � � CL ?�: � e / tit P G r'�,v/,91g1, y ?i � t^m h�' � a, r• .9,,. r 1 / (�\\V' � 41 rZ I i 73­ �t�',-.- ,`�^Y xa +�'sy•' ?f%"'ity�Gj�y� �/ � �\.`.. 71' �D� /� °r ¢� ( C'F LJ -ZF ?'\. /\ �., Q g `,.\ i,(� rr� lE ..�. ,t,._...,�' / r ✓i r r f n A£.£F'./v ,,� �;-%S _ "L( Yoh `',<, �j�'t'r�' // � � i/ `� ��,�•(� r { 44 sL ul�/C�n�`"M1 � h� c�� •a��'r r 1�9 a / rr / � Qx� I / � 6i Nil � 2� �� � •� :I: ��. : �B�o��LN .�J� �a'u .r\\ ���`�;. 11 /< .'a'. 8_ �� � r 4 �,// � arm IIIF � m lot ' U) _J -"' � � " 6 �.fa � . _ �Gi I r � ;��C\O•,4, r, •/i _\ ��5��'+`s®�r'��� "'/f`� �:YSk �i� 4- t� `,r-�r \\ ! _s'' 5 � ' to £gip\+ `Y-r i i /roSS d^ '�' \`. I NP .�`•' knit . a 1so r T /k...+c✓. I M o'-' ` "s' rs; S a \,} sAve i,�, > °'A�dY s 'h�i `-�f v �;':• 'e sir . AA,,yy _ / 1A '%' y / .9 m�`;I'- rrl a—_,_.__ .-_._ .i 4-3k'�'� #-- �i"' '/�G/l/.G .r \ `'. ,�.i' `��� \, *,.'ax4 TSY / V• �11.. �r, \'S���..�yF'`/' .. \-s .\ RIGHT ELEVATION SCALE: 1/4" - 1'-0" ROOF MATERIAL RIDGE VENT - NOT SHOWN SHINGLES TO MATCH EXISTING 150 ROOFING FELT 5/8" OSB SHEATHING 2 x 10 RAFTERS 1 16" O.C. 8" (R-30) NI-PERF. FG INSULATION PROPER VENT FOR AIR FLOW TO RIDGE 1 x 6 T4G V-JOINT PINE CEILING (2) 1-3/4" x 14" LVL RIDGE BEAM WITH PINE TRIM SAVE MATERIAL METAL DRIP EDGE ICE t WATER SHIELD • EAVES ALUMINUM FASCIA 2 X 6 "FASCIA VENTED VINYL SOFFIT WALL MATERIAL DOUBLE-4 VINYL SIDING TYVEK OR EQUAL BARRIER 1/2" OSB SHEATHING 2 X 4 STUDS • 16" O.C. 3-1/2" (R-15) FG INSULATION POLY VAPOR BARRIER GYP. WALL BOARD FOUNDATION MATERIAL STAMPED CONC SLAB FLOOR 8" POURED CONC. FROST WALL 2" RIGID FOAM INSULATION CROSS SECTION SCALE: 1/4" - 1'-0" PROVIDE ANCHOR BOLTS S' 0/C MAX AND 12" FROM CORNERS AND JOINTS UNEXCAVATED STAMPED CONCRETE FLOOR W/ RIGID INSUL. 8" POURED CONCRETE FROST WALL 014'-0" Fek.ezir FOUNDATION PLAN SCALE, 1/4" 1'-0" EXISTING FAMILY ROOM OPY LEFT ELEVATION T{ C - - c� *E'ENE ;j -/ "U;t. NG DEPARTMENT ~sawed on our l;rnited examination, SCALE: 1/4" ■ 1'-0" compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the code, T014VN OF Q1.1�L�-.�`�`° ...;fir BUILDING %n'T" REVIEWED BYDATE /„ GARAGE DOOR LOCATION Z �. . 1 • SUNROOM I STAMPED vE11oc F6-106 L-dSKYLIG44TS _ CONCREiE 1� Q I � fie ' • Cr sloped I CrI e111g 1 n A .• 0 d I CUSTOM CUSTOM y FIXED I FIXED 2062 2 2062-2 4'-4" 61-514" 41-4" 6'-514" 4'-2" 51-8" 13�-a 14'-0" FLOOR PLAN SCALE: 1/4" - 1'-0" Midnight Oil .Design Ashton (AK) Hayes III 297 Ridge Street Glens Falls, New York (518) 792 - 7173 akiii@yahoo.com 0 Y l a o Zi o�� �o U -71 z 0 A Q lu d cc) Job No.: - 2002-03 Q Dwn By: AK Hayes Date: 04/07/2002 Scale: As Noted Revisions: Sheet: e E'V D JUN 0 3 �0 / roW,V D,t