Loading...
2002-438 TOWN OF QUEENSBURY r 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes. (518)761-8256" i CERTIFICATE OF OCCUPANCY Permit Number: P20020438_ _ Date Issued: Tuesday, June 17,2003. This,is to cerdfy thatwo&requested.to be done as.shown by-PermitNumber . . P20020438 has been completed. Tax Map Number: 523400-296-017-0001.047-000-0000 Location: 900 STATE ROUTE 9 ..Owner: D&C MANAGEMENT ASSOCIATES INC Applicant: PIZZERIA UN0 CKICAGO BAR&GRILL This structure may be occupied as a: By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN OF QUEENSBURY fill 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020438 Application Number: A20020438 Tax Map No: 523400-296-017-0001-047-000-0000 Permission is hereby granted to: PIZZERIA UNO CHICAGO BAR & GRILL For property located at: STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: D & C MANAGEMENT ASSOCIAT Commercial Alteration 500,000.00 16 DEER Run Total Value 500,000.00 GANSEVOORT,NY 12831 Contractor or Builder's Name Address Electrical Inspection Agency Plans&Specifications BP 2002-438 PIZZERIA UNO CHICAGO BAR& GRILL 7538 SQ FT COMMERCIAL INTERIOR ALTERATION AS PER APPLICATION; former Ponderosa; Address: 900 State Route 0 $904.56 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,July 31,2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Wednesd y,July 31,2002 SIGNED BY for the Town of Queensbury. Director of Building&Code 06'-r�cent Building Permit Application Town of Queensbury—Dept of Community Development, 742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. No inspection will be made until applicant has received a Fee Paid $C valid building permit. All applicants' spaces on this Rec. Fee Paid $ application must be completed and must appear on the Reviewed By: application form. Applicant: N( 9-v� Owner: 2 aQ �r Address: ���I�C�E,.��� ) Address: / Phone#(S f ) S Phone# Email Address: Q�i��7_[�r s h "( Q,y�e� Email Address: S �`z Property Location: Lot Number: I House Number / y1f5T/t�1Gc Subdivision'Name Tax Map Number: ❑ New Building: residence /commercial Estimated Market Value of Construction: $ cam o o o a Af ❑ Addition: residence/ commercial If an Addition,what will use of new addition be? ua' Alteration: 130sideace/ commercial ti* No change to exterior size: residence/com'l ❑ Other work(describe ) Check OccupancyInformation 151 Floor 2'd Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet ❑ Single family dwelling o Two family dwelling ❑ Townhouse ❑ Multifamily dwelling #of units MAY E 9 002 ❑ Office TOWS SBURY ❑ Mercantile BUILDING AND GODS ❑ Manufacturing ❑ i car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage ❑ 2 car attached garage ❑ 3 car attached garage ❑ Storage building- commercial ❑ Storage building- �_-A residential, TK TIC " f ❑ Other ,j i What is the'proposed height of the structure feet 4_inches Will any second-hand or ungraded lumber be used? If so,for what? 1h Type of Heating System: electric/ oil / gas/wood /forced hot air I baseboard/othet: Number of Fireplaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: i Name Address Phone Number Builder i Plumber Mason Electrician i i Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other lawspertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature: '1l1< owner,owner's agent,architect,contractor BLDG. PERMIT NO. .2002-438 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A-TE-M-PORAR-Y-C-ER'PIFIC-A-T-E-OF-OC-C-U-PANC-3-isfiereby-requested-for-the-property- located at; 900 She Route 9 for the following uses: PIZZERIA UNO CIICAGO: BAR 9 GRILL (made--1-0;-2-J03 - ---- DATE- --SIGNATURE OF.A LICANT . . TEMPORARY-CERTIFICATE OF OCCUPANCY The,TEMPORARY CERTIFICATE OF OCCUPANCY is herebY . ( APPROVED ( )DISAPPROVED with the following.conditions: C Occu�aancy to be izzued-upon Com*.Zetion oA: 1). T=nAtaL,e tevyc hanyte on. b"ement door 2) Paint Bab-ement Wa.('.f 3) S.kipe N.C.- Panlu:ng Spaced 4)-.f'ini-6h UlWhm.6ttippincg eAound exit DooAz TEMPORARY CERTIFICATE OF OCCUPAN : O$1 00 DEP I { 4400.00 Mai' c.h 10, 20,03 :' Date of Issuance' Director of:Bldg. & ode.E forcement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES 90 DAYS FROM THE DATE OF ISSUANCE. NOTE: This .Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcenient or his designee. W jr@ gjPLrQ rL3 rL3 r@ rL3 rd3'L3"L3I Rrr3 P r 10 rLME M' g Rfafflj"LJI� I&rL3PLPdjjPrj-L3PLPr r3j-r3rrj3r3l'j2P L rL3 PL 1�L 3 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 BUREAU OF ELECTRICITY Sc 5 40 FULTON STREET - NEW YORK, NY 10038 5 CERTIFIES THAT Upon the application of upon premises owned by 5 . 5 5 5 DOUBLE L. ELEC.CONTR. PIZZERIA UNO CHICAGO BAR& GRI 46 TWIN CHANNELS RD. GLEN ST 5 QUEENSBURY, NY 12804-7230, QUEENSBURY, NY 12804 5 A� 5 5 5 Located at GLEN ST QUEENSBURY, NY 12804 5 5 __ 5 Application Number: 1098253 Certificate Number: 1098253 Section: Block: Lot: Building Permit: BDC: A239 Described as a Commercial occupancy,wherein the premises electrical system consisting of 5 electrical devices and wiring,described below, located in/on the premises at: Basement,First Floor,Outside, 5 5�� 5 was inspected in accordance with the National Electrical Code and the detail of the installation,as set forth below,was found to be in compliance therewith on the 10th Day of March,2003. 5,;. 5� 5 Name Y Rate Rgjjjjg Circuit Type Additional Charges 2 walk in freezer 30 amp each 5 3 lighting contactor Alarm and Emergency Equipment Emergency Light 16 0 Visual Exit'Light - - — - - -, 1,-3 0 --- -- - -1- Visual - 5 Appliances and Accessories Air Conditioner 2 0 100 Amps 5 5 Air Conditioner 2 0 70 Amps 5 Furnace 4 0 Gas Dish Washer 1 0 KW 5 Exhaust,Fan 4 0 30 Amps Electric Heater Unit 1 0 60 Amps 5 Hand Dryer 2 0 10 Amps Time Clock/Switch 3 0 40 Amps Water Heater 1 0 Gas Water Heater 1 0 2 KW Z" 5 Oven 1 0 10.8 KW Continued on Next Page I of 3 This certificate may not be altered in any way and is validated only by the presence of a raised se I af-"tdhb-"'�q�ti icated. E 1 L:' iL3,PL FE�3.PE:Pr L3pr WL30 0�'M-d3-r3j-L3FL3,M-L3 PL Pd-r3 P PE: I 0� �'M 19 10,E PR PR 0 IVE Pr-N,IN,2 7 LPLPCJ 1pr�Lff[ L3F _PEM 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 :, BUREAU OF ELECTRICITY 5 40 FULTON STREET — NEW YORK, NY 10038 5 5 5 CERTIFIES THAT Upon the application of upon premises owned by cS DOUBLE L. ELEC.CONTR. PIZZERIA UNO CHICAGO BAR& GRI 46 TWIN CHANNELS RD. GLEN ST 5 QUEENSBURY, NY 12804-7230, QUEENSBURY, NY 12804 5 5 5 5 Located at GLEN ST QUEENSBURY, NY 12804 _ �� y _ __ w �__5 _ 5 Application Number: 1098253 Certificate Number: 1098253 5Section: Block: Lot: Building Permit: BDC: A239 5 �_ 5 Described as a Commercial occupancy,wherein the premises electrical system consisting of 5 .r electrical devices and wiring, described below,located in/on the premises at: Basement,First Floor,Outside, J: 5 5 5 C5 5 was inspected in accordance with the National Electrical Code and the detail of the installation,as set forth below,was 5 5 found to be in compliance therewith on the 10th Day of March,2003. 5 5 Name QTY Rate Rating Circuit Type Oven 1 0 6 KW 5 Oven 2 0 1.6 KW Oven 1 0 16 Amps Oven 1 0 24 Amps Oven 1 0 29 Amps Srvfiotors"- - - S 5 1 2 5 1 1.6 5 Panels 5 200 42 1 200 30 5 1 400 42 1 150 24 5 Wiring and Devices Fixture 228 0 Incandescent Receptacle 86 0 General Purpq-lse 5 -75�? Receptacle 4 0 GFCI seal Z "T 5 Switch 17 0 General Purprjse� T Y_ Continued on Next Page 2 of 3 Z- Lj 0 `>; 5 r, This certificate may not be altered in any way and is validated only by the presence of a raised seal at the ltpdi i mriftdic' INJI I 0rJR W,I@�Q3,�"L3,�'-L3 Q,R Pr PLPLpr-pr-PLPL,�'E,��m��'RPLPLPL Pr-PRIERPRI01 03112 1200-P0 7011,019!pr-PRIVE-PRIVEIVEIVEP01101 Commercial Final h-ispection Report Office No.: (518) 761-8256 Date his tio request received: p , Queensbury Building&Code Enforcement Arrive: NO am/pm Depart: am/prrL 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: ?'t 10c) PERMIT#: LOCATION: ' DATE: LP -./2-io/3 COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—_3 8 in./Step Risers 711/Treads 1111 Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.w/Lever Handles/Panic Hardware, if required Exits At,Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 V2doors > 10%> 1000 sq.ft. 3/4Hour Corridor Doors&Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors Ceiling Fire Stooping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"..xZ4" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilefs Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible/ Handicapped Service Counters, 34 in., Chdckout 36" Handicapped Ramp/Handrails Continudus/12 in. Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification, if reg, As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 201 wide Oka-J& ue.Te] p,'-`ok.,Permanent.00, w _T Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\Pam.W\Building&Codes\Commercial Final Inspection Report.doc CONImERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 DepL of Community Development Town of Queensbury Arrive am/pm ]3egartx�lpm 742 Bay Road lnspector's Initials Queensbury,NY 12804 NAME C-,— PERMTT# DO— 3 LOCATION 0 DATE Cp --.1t?-0 TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney/"B"Vent/Direct Vent location Plumbing Vast Roof Complete f Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks haeriar/exterior ballasters 4 in.spacingplatfonn/decks Stair handrail 34 in.-38 in. Step risers 7'Kin. c�7� ?slain door 44 in. j � G� All others 36 in. SQy/I , S it �/` Lever handles Exits at grade or platform Canopy to cover req.exit doors Gras valve shut-0ff exposed&regulator(18 in.)above gra Floor bathroom watectig#st Other floors okay Hot water relief valve Boiler/fuace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(I hour) >1.000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or within line of site Cal furnace shut off at entrance to furnace area Suxkroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/z doors I ',i hour doors and closers '4 hour corridor doors and closers Fnrewalls/fre separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/a hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks4oilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond dive listening system and signage assembly space Final Electrical Site PlanNariance required Final Survey,new structures .As-built septic system layout required Okavto issue taM.C/O(Certif of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone(518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request &,5a SCHEDULE Received: -Permit# INSPECTION ON: Name: Y -2-2-Q)VC, 17 AM PM ANYTIME Location: I APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM I l FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS e-( wile- CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN kA X)l CHIMNEY MASONRY ROUGHIN FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGHIN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN T OK OK THIS D TE A OK FOR CO NOT FINAL ;+11 FIREPLACE FACTORY BUILT. ROUGH IN INSPECTED BY FINAL 4jOMDEV/CHPJSJ/WORD/LETTERS20011FIREMARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY COMAIERCLAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive am/pm Depart am/pm 742 Bay Road Inspector's Initials Queensbury,NY 12804 NAME PERMIT PJ 4�� LOCATION DATE 7� TYPE OF STRUCTURE I 4 N/A YES NO CON 4ENTS ChinmeyP'B"Vent/Direct Vent location Plumbing Vent Roof Complete Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks hrterior/exterior ballasteas 4 in.spacingplatform/decks Stair handrail 34 in.-38 in. Step risers 7%in. Main door 44 in. ,all others 36 in. Lever handles 74CJ�'rrad.2"�- Exits at grade or platform V, J�S " Canopy to cover req.exit doors L°!L'Gt Gas valve shut-off exposed&regulator(18 in.)above gradd Floor bathroom watertight � /� ,�Se fre-- / t J4/& Other floors okay Hat water relief valve � e j 2 (Ui C r ticpl Boiler/furnace enclosure y / Wow-", <250,000 BTU N/R ( ) ,� -> f' ,�+ �;ru i, 2>0�� 250,000 BTU to 1,000,000 BTUs I hour �nIdi% e?w '� �✓ `� >1,000,000 BTU's(2 hour) Gas furnace shut off within 301 or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(I hour),3/.hour door Storage/receiving/shipping room(2 hour), 1 '/z doors I 14 hour doors and closers '.hour corridor doors and closers Fimwalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/a hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinkshoilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond :active listening system and signage assembly space Final Electrical Site Plan/Variance;required__ Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Oocupancy) -�T I I Okay to issue C/C(Certif.of Compliance) COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No.(518)761-8256 Dept. of Community Development Town of Queensbury Arrive&am/pm Depart prn f 742 Bay Road Inspector's initiw;s Queensbury,NY 12804 NAME PERMIT# LOCATION DATE a=—0 TYPE OF STRUCTURE ` N/A YES NO CONB/ENTS ChimneyP'B"Vent/Dire t Vent location Plumbing Vent Roof Complete Exterior finish grade complete Interior/exterior guardrails 42 in.platfonn/decks literior/exterior ballasters 4 in.spacing platforni//decks Stair handrail 34 in.-38 in. Step rrsm 7%in. Main door 44 in. All others 36 in. f /� r�✓c �Gkr�IC i Lever handles Exits at grade or platform Canopy to cover req.exit.doors Gas valve shut-off exposed&regulator(18 in.)above grade Floor bathroom watertight Other floors okay Hat water relief valve Boiler/fiunace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft,or within line of site Oil furnace shut off at entrance to furnace area Cl&, d Glo Stockroom enclosure(1 hour),'/hour door j�/J/ LAC/ Storage/receiving/shipping room(2 hour), l 1/z doors 1 1,i hour doors and closers ?a hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete ` ter Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 'lz hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. _ Fan shutdown,smoke vents or fan ��c 1l s mot- ������ /,�r Qi✓ Exit door/panic bars assembly hardware Elevators �w/' Elevator signage Clt°1' Ul��� J" Crry''Z f Handicapped bathroom grab bars/sinkshoilets _ � �� W.» Y'—sf! , 1nZ cI— ey-k i,- Handicapped bathlparking lot signage J Handicapped service counters 34 in.,checkout 36 in. Zl � G C4Handicapped ramp/handrails continuous/12 in.beyond /v Active listening system and signage assembly space p , Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required Okay to issue ternp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) / Okay to issue C/C(Certif.of Compliance) t✓ t �� �� rt t�N ��'�1 Town of Queensbury Fire Marshal's Office . 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit#-'QQ0,a-q2,-2-R INSPECTION ON: Name: 6p-r1 92h AM ANYTIME Location: APPROVED N/A I YES YES NO COMMENTS EXITS NO AISLE WIDTHS fiq 5 VJ'l MU-4- C91 *jV7 EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM x I FIRE SUPPRESSION SYSTEM X, LO HOOD INSTALLATION Flt)A INTERIOR FINISHES COMPRESSED GAS Fop, M AAX,(\1Am 4t�,k 5, Lw STORAGE owt CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS x CLEARANCE TO ELECTRICAL X — REQUIRED SIGNAGE EMERGENCY PLANA MAXIMUM OCCUPANCY SIGN CHIMNEY ROUGH MASONRY �bm FINAL El w CHIMNEY ������ FACTORY BUILT ROUGH IN FINAL WOOD Tote ��aUa '�Y t STOVE ROUGH IN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN OK THIS DATE OK FOR CO& NOT OK FINAL FIREPLACE 7 FACTORY BUILT ROUGH IN FINAL COMDEV/CHRISJANORDILETTERS200I/FIREMARSHALINSPECTIONREPORTliO22001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Town of Queensbury Fire Marshal's Office 742 Bay Road �K Queensbury, NY 12804 �I Phone (518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit# ®w- INSPECTION ON: Name: tI, r � UAL 1,10D AM PM ANYTIME Location: APPROVED N/A YES NO COMMENTS EXITSAISLE { EXIT SIGNS WIDTHS NORMAL � � I - BATTERY EMERGENCY LIGHTING KkA w1(X1 y FIRE EXTINGUISHERS 11 FIRE ALARM SYSTEM x � � FIRE SPRINKLER SYSTEM 1, FIRE SUPPRESSION SYSTEM A HOOD INSTALLATION FINISHES INTERIORjr �5 1 1(a�,,oA�5 STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS (-aTO ELECTRICAL I � � ��" ► I l pZ oil CLEARANCE REQUIRED SIGNAGE EMERGENCY PLAN �Q1-110f' Le MAXIMUM OCCUPANCY SIGN MA ONRY ROUGH IN t�,�� � !'� 1J extCHIMNEY . FINAL tr�(1 014e GI;.`� 6 0 M CHIMNEY FACTORY BUILT ROUGH IN WOOD FINAL ice , V r STOVE ROUGH IN T p , FINALVENTED t APPLIANCES' ROUGH INL�0�� FINAL CA FIREPLACE MASONRY ROUGH IN OK THIS DATE OK c0 NOT OK FINAL , FIREPLACE FACTORY BUILT ROUGH IN I SPECTED BY FINAL COMDEV/CHRISJ/WORD/LETTERS20011FIREMARS HALINS PECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY FINAL — COMMERCIAL fNSPECTIOVN PORT Request received. J 0 1 t Office Use Town of Queensbury (518) 761-8256 ARRIVE am/pm: DEPART am1pin 742 Bay Road Ready at time: Queensburqy, 2804 Inspector's Initials Vho, Meet: NAME , PERMIT# At time: LOCATION 0-4�le Y 4 TYPE OF STRUCTURE INSPECT ON(date): 6 Notes: N1 YES NO Chimney/"B"Vent/Direct Vent location 'Plumbing Vent a r)",RdAX die—, Roof Complete COMMENTS Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks V 71� U� Interior/exterior balusters 4 in.spacing platform/decks_ Stair handrail 34 in. -38 in. Step risers 7 3/4 in, Main door 44 in. hrsjel- All others 36 in, zevee- Lever handles Exits at grade or platform Canopy to cover req.exit doors X �711JAI� 6440 Kf Gas valve shut-off exposed&regulator(18 in.)above grade Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU NT/R 250,000 BTU to 1,000,000 BTU's(1 hour)_ >1,000,000 BTU's(2 hour)_ Gas furnace shut off within 30 ft.or within line of site Oilfurnace shut off at entrance to furnace area V Stockroom enclosure(1 hour),3/4hour door z doors Zee. n c,,n V sew8le A'4FX-'w1 Storage/receiving/shipping room(2 hour), 1 V 1 1/2.hour doors and closers Ae 3/4hour corridor doors and closers (lost" 010k /7Y-,PX Firewalls/fire separation,2 hour,3-hour complete Fire dampers,2-hour fire wall/separation or greater Fire door/shutters 1 V2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware .2X- Elevators Elevator signage • /K, Handicapped bathroom grab bars/sinks/toilets ✓ b1f AV1,(cj X Za .Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in, Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space /Alit Final Electrical Site Plan/Variance required 1-1 z 144 Final Survey,new structures Ae As-built septic system layout required 0�744/ Okay to issue TEMPORARY CIO—Certificate of Occupancy yes_ no Okay to issue PERMANENT C/O—Certificate of Occupancy yes_ no Okay to issue C/C—Certificate of Compliance yes— no Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE T_1L (��m Notes: am 7 (518) 761-8256 Inspector's 71nitia,17 NAME: PERMIT# LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/D amppro ofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig- Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firesto i PPITI L:\SueNemingway\Building.Codes.Inspection.FORIvIS\GENERAI,INSPECTION REPORTAOC Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE tt Received: Permit# INSPECTION ON: Name: -IL)-17 .6 AM PM ANYTIME Location: APPAQVED N/A YES NO COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM Ot ( Lo[�3w,� �001 HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS WC CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIQN CHIMNEY MASONRY ROU H IN FI AL CHIMNEY FACTORY BUILT ROUG14V WOOD STOVE ROU HIN VENTED GAS /FINAL APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN <OfKTHIS DATE OKf` C NOT OK e7 FINAL FIREPLACE FACTORY BUILT ROUGH IN I I NSP=f ED BY FINAL 7 - coMDEV/CHRISJANORDILETTERS20OI/FIREMARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time:M� Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE i s D T a m Notes: (518) 761-8256 Inspector's Initi NAME: _ a 0(c PERMIT# 4 3t LOCATION: 1 INSPECT ON(date): �?_ TYPE OF STRUCTURE: c- RECHECK N/A YES NO COMMENTS. Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is"responsible for providing protection from freezing for 48 hours following the placement ` of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofmg Backfill Approval Plumbing Under Slab .plumbing Vent/Vents in Place ,,ough Plumbing __._ eating Rough-In nsulation Foundation Walls Interior R Foundation Walls Exterior R Floors R Walls R- Ceiling R- Duct work or piping in unheated spaces R- Vroper Vent,Attic Vent raining Jack Studs/Headers Bracing/Bridging- Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,Hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppmg L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAI.INSPECTION REPORT.doc Office Use .GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time. Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Notes: Queensbury, ATY 12804 ARRIVE a �pm (518) 761-8256 Inspector's Initia DEP s In a itz V PERMIT ,e cr 46 NAME: r/A, Ai4- rg /PPERMIT it C�W-)-— LOCATION' INSPECT ON(date): /5/6 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site 'FoundationfWallpour Reinforcement in Place Foundation/Dan-ipproofing_ Backfill Approval f Plumbing Under Slab %.-oo Ph x n,!tbiVent/Vents in Place Heating Rough-In�_ Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping mi . unheated spaces R- Proper Vent,Attic Vent Framing_ Jack Studs/Headers Bracing/Bridgmig— Joist Hangers Jack Posts/Main Beam. Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping_1 L-,\SueHemingway\Buildiiig.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT-doe GENERAL ZN'►PEC'TIiON REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive3�an p>Sii, Depa « •� + Inspector's Initi NAME: t�i _ PERMIT it LOCATION: -,.-- �1 LM DATE: TYPE OF STRUCTURE: RECHECK NIA YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour _ Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- per Vent,Attic Vent � raining Jack Studs/Headers Bracing/Bridging � Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppin GENERAL IV, REPORT ( 51.8) 761.-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road 4' , Queensbury,NY 12804 Arrive"am/pm DepaInspector's In NAME: Z2 PERMIT# LOCATION: 1 DATE: Z TYPE OF STRUCTURE: �A t< RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place V The contractor is responsible for providing protection from freezing for 48 hours following the placement / of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In f Insulation / Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- / Ceiling R- Duct work or piping in unheated spaces R- .` Proper Vent,Attic Vent r' Framing t` Jack Studs/Headers J Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3;4 hour Firestopping Office Use GENERAL INSPECTION REPORT Inspector: Town of Queenshury Ready at time: Dept. of Community Development Request received.- Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE)tAn a r Notes: amp —D al!�P/ (518) 761-8256 Inspector's Initia TT 4 NAME: uo C) V,Z�z E ej A PERMIT# Z=M-Z— q3B LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing_ ,Fackfill Approval VPlumbing Under Slab 9m PL\— Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- C Floors R- , Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppmg L:\SueRemingway\Btiilding.Codes.Inspection.FORMS\GFNERAL NSPECTION REPORT.doe Office Use GENERAL INSPECTION REPORT Inspector:77 SO—N r $0, Town of Queensbury Ready at time:nlLjQ� Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road L,0 q2 5(��m Queensbury, NY 12804 ARRIVE 'a D AR Notes: (518) 761-8256 Inspector's Initia NAME: 00C) PERMIT# ZoOZ-- �432) LOCATION: C INSPECT ON(date): 1(') — TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. IMaterials for this purpose on site VIFoundation/Wallpour — Reinforcement in Place 4— Foundation/Dampproofmg_ Backfill Approval 6, Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing_ Jack Studs/Headers BracingfBridgm' g— Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppin L:\SueHemingwayTuilding.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept,of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive jVf—am/pm Depart am/pm Inspector's Initial) NAME: l`t-L'I try PERMIT# ` `I LOCATION: DATE: TYPE OF STRUCTURE: RECHECK N/A YES-NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpo si 1,f� Foundation/Wallpour ' Reinforcement in Place Foundation/Dampproofing Backftli Approval Plumbing Under Slab Plumbing VenttVents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R Foundation Walls Exterior R- i Floors R / Walls R- Ceiling R- / Duct work or piping in unheated spaces - Proper Vent,Attic Vent Framin Jack Studs/Head. s Bracing/Bridgilag Joist Hangers Jack Postsftvlain Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppin Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept of Community Development Request received: A)/9 /6z- Meet: Building& Code Enforcement At time: 742 Bay Road Queensbuq, AT 12804 ARRIVE llwramlpm: DEPART amlpm Notes: (518) 761-8256 Inspector's Initials NAME: PERMIT# AdOL LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this p osq on site � Ae" a�- oundatiowWallpo:Tr otj-� 4;,— rzktf— tF" einforcement in Place Foundation/Dampproofing_ Backfill.Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing__ Heating Ron Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour�_ Firestopping_ L:\SueHemingway\Building.Codes.inspection.FORMS\GENERAL INSPECTION REPORTA& 12)-1 Office Use GENERACL INSPECTION REPOR Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: rV- F Building& Code Enforcement At time:Ljp.,1,,-70 A 742 Bay Road Notes: Queensbury, NY 12804 ARRIVE R in r's Initi(518) 761-8256 Inspector's NAME: rmwl-- assoc'. PERMIT# 2Q.2, q3 tr LOCATION: U J?a r i Ct INSPECT ON(date): 24 77,L� TYPE OF STRUCTURE: C= RECHECK N/A YE NO COMMENTS I_F�ooti rMonolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48-hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofrog Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing-_ Hearing Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig- Joist Hangers Jack Posts/Main Beam. Air Infiltration Barrier Fire Separation 1,2,3,hottt Penetration Sealed Fire Wall 2,3,4 hour Firestoppig L:\SueHemiiigway\Building.Codes.Inspection.FORMS\GENERAI,INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPO Inspector: Town of Queensbury Ready at time:' Dept. of Community Development Request received: Meet: .Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE+ � a pm: e,� a p Notes: (518) 761-8256 Inspector's Initi is NAME: �„ 3 0 PERMIT# e? LOCATION: t 9 INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. 41,aterials for this purpose on site v oundation/Wallpour Reinforcement in Place OEL, Foundation/Dampproofmg 1-� Backfill Approval / Plumbing Under Slab 1 `� Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main BeaYn Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Buiiding.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVES:1Z a am7J9'm Notes: (518) 761-8256 Inspector's Ini NAME: PERMIT# -7 C)cz- LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A S N COMMENTS V'/Footings/Piers L I./ Monolithic Pour Form —r�,+44 4einforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement C, of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place ` � � ��ti`-' ��~ U Rough Plumbing_ Heating Rough-In. Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers — Bracing/Bridgig— Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fite Wall 2,3,4 hour Firestopping_ L:\SueHemingway\Building.Codes.Iiispccfion.FORMS\GENERAL INSPECTION REPORTAOC STATE OF NEW YORE. - - DEPARTMENT OF HEALTH- Glens Falls District Office 77 Mohican Street, Glens Falls NY 12801 (518)793-3893 Fax(518)793=0427 Antonia C. Novello, M.D., M.P.H., Dr.P.H. Dennis P.Whalen Commissioner Executive Deputy Commissioner August 22, 2002 Dave S. Kapoor 16 Deer Run Gansevoort,NY 12831 Re: Proposed Food Service Uno Pizzeria Chicago Bar& Grill Facility Code# 56-AD88 (T) Queensbury, Warren County Dear Mr. Kapoor, I have reviewed and approved the plan submitted for the above food service establishment. Please advise us when the project is ready for a pre-operation inspection. If there are any questions, please call me at 793 3893. Sincerely, Joseph Curatolo Principal Sanitarian Cc: Anita Gabalski, District Director +ueenslauZ :,, � t ;n 4i ce STATE OF NEW YORK DEPARTMENT OF HEALTH Glens Falls District Office 77 Mohican Street, Glens Falls NY 12801 (518)793-3893 Fax(518)793-0427 Antonia C. Novello, M.D., M.P.H., Dr.P.H. Dennis P.Whalen Commissioner Executive Deputy Commissioner August 2, 2002 J x Ck Dave S. Kapoor V 16 Deer Run Gansevoort, NY 12831 Re: Proposed Food Service Uno Pizzeria Chicago Bar& Grill (T) Queensbury, Warren County Dear Mr. Kapoor, I The plan just submitted for the above-proposed food service establishment did not include the following: • Layout and description of the kitchen equipment. • Menu. • Finish materials list for the kitchen and bathrooms. • Details of the equipment in the bathrooms. • Seating capacity. You also did not complete and submit the plan preparation guide. I have enclosed another copy for your use. Please be advised that no construction should be started on this project without written approval from this office. If there are any questions, please call me at 793-3893. Sincerely, Joseph Curatolo RECEIVED Principal Sanitarian AUr, 0 R' 2002 TOWN OF QUELASBURY Cc: Anita GaLbg1ski,District Director BUILDING AND CODE t(ftl QR—e—en,sb"T�70�;Ubo'T�emwenit ffifffi_-RY TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 518-761-8201 ca -0 411=F TO: Dave Kapoor FROM: David Hatin,Director Building and Code Enforcement DATE: July 9,2002 RE: Pizzeria Uno Plan Review I On the structural plans,replace or change note where CDX Plywood is shown,to read CDX Plywood over 5/8th's exterior gypsum or some other type of noncombustible material Change size of exit doors to 44 inch doors. Change door swing from garden area to main dining area to swing towards main dining area. All exterior exit doors must have panic hardware. All non- latching doors are not required to have panic hardware. Note on the plans that all glass will be safety glass or tempered glass,as required by the Code. In the kitchen, the interior one hour fire separation must be continued across the cooler. Provide a cross section showing the detail of the one hour wall for the kitchen. A sprinkler head must be added inside the cooler and in the kitchen area to protect the door going into the cooler. The doors in the kitchen from the dining areas must be a three quarter hour fire rated and be on magnetic hold backs, not flushable links. We need a detail on the hood system showing the design of the hood and the fire extinguishing system. We need a complete sprinkler system layout to be reviewed by the Fire Marshal. OWe need to add smoke d,� bathrooms a heat d=etector in the kitchen area and a smoke��'-he�bathro detector in the vestibulf."Provide a horn strobe and smoke detection in the basement area., ?The basement stairwell must be one hour rated with a three quarter hour fire door at the top of the stairwell. We need a note on the plans'that states all plumbing will be cast iron or copper. e need to have emergency lights and an exit light installed in the basement area, as well as an exit ligh t over the exterior exit door from the main dining area. 3 1 We need handicapped elevations of all interior bathroom layouts, fully dimensioned. TZA/ e need notes that show canopies over the rear exit doors. We need the details showing the handicapped area at the bar adjoining the main dining room. /4. The exit door from the main dining room to the patio must have a clear area that leads to the parking lot and must have a dropped ramped curve at the parking lot for exit purposes. "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO LIVE" SETTLED 1763 /We need a statement on the plans that says this building complies with Part IV of the Energy Code. Once the above items have been revised on the plan and submitted to this office for approval, a building permit will be issued. P GENFILkL BUILDING CONSTRUCTION CHECKLIST Subchapter E Applications Owner: Q)-4 Reviewed by: (-Pk Location: Date:- -) !/ - Type of W:Ork: Within Fire Limits: Maw. Date of Substantial Completion: Note: Topics listed in italics are-._available. only to buildings' which are 10 years or older. is this a Minor Building ? See Table I-1233 Yes or No No Topic ' Code Required or Actual Section Allowed 1 Occupancy proposed 701.4 Fire ,Hazard Class 702 C§. 2 Construction Type 704.1 3 Height & Fire Area 705.4 Basic Area Tables 705 Basic Height Accessibility 705.5b 70Mj Sprinkler Increase 705.5c 109 allowance 1233.2c 3 Story, wood frame 1233.2d 4 Space I Requirements �1 Ceiling Height 762.3 (e� 762.4 Existing Ceiling 1233.3b GUI,- lctr/py 5 Light Ventilation 763 Artificial Light 763.1 Natural Light 763.2 Ventilation 763.3 Existing 1233.3c 6 Special Stairs 764.1 Or /t' C-1�/a" No Topic Code Required or Actual Section Allowed 7a Exits C 44�1_4j 61IJ(,&JSa1 Number 765.8 ,One Exit Permitted Th X-765 -Units of Exit Width Distance of Travel Th VI-765 Dead End Corridor 765.lj Enclosure Th 111-704 Existing Enclosure 1233.4c Corridor Width Th 1-765 " Door Width Th V-765 Existing Doors 1233.4b Smoke Stops 765.2a Opening Protectives Th 111-771 Panic Hardware 765.5a4 Door Alarms 1060.9a 7b Stairways 765.4 Access to Roof 765.4a Dimensions Th IV-765 Existing Dimensions 1233.4a4 Combustible stairs 765.4b2 765.4c3 Existing comb. stair 1233.4a2 Minor Bldg 1233.4a6&7 Handrails 765.4all 8. Safety Glazing 766.1 9. Garages and-Parking 767 �/ Structures 10 Malls and Passageways Passageways 768.1 Malls 768.2 11 Atriums 769 Existing 1233.8 12 ' Exterior Fire Spread Part 770 Distance Separation Th 1-770 ExIs Ling 1233.5b Tb IV-1233 Construction Limits 770.2c&d Type 4b & 5 1233.5c Party Walls 770.6 Parapet: 1233.5a Finishes 770.8 age- C 2 Jove) No Topic Code Required or Actual Section Allowed 13 Interior Fire Spread Part 771 Fire Separation Th 11-771 Mixed Occupancy 771.4a6 .Allowabl,e Mix 1233.6b Openings 771'41 Existing Openings 1233.6a Fire Stopping 771.5c 14 Interior Finish .772.2 Existing 1233.7 15 Plastic Materials Part 773 Part 1120 Existing 1237.3 16 Fire Protection Equip Fire Alarm System " 7.74.2 Zoned System 1060.2a5 Battery Backup 1060.2d1 Pull Box travel Th 1-1060 Fire Dept Connection 774.1b Detection system 774.3 Sprinkler System 774.4 Standpipe System 774.5 Yard Hydrants 774.6 Watchman System 774.7 Auto Vent Alarm 774.8 Co.odinated Fire Safety 774.9 17 SPECIAL HAZARDS Areas of Pub. Assemb. Fire & Smoke Det. 791 Sprinkler System 792 Gas Pumps I 774.10 1231.3e Emergency Ventilation 1004.2f Fan Shutdown 1004.2e Exhaust Hood System 1064.2b 18 Design Loads Snow 803.3 Floor Th 111-803 Wind Th V-803 lj Th VI-803 Existing Adequate 1237.2 w/ {~I,t,�,�i I' oti.. Yltliof✓�2 C if No Topic Code Required or Actual Section Allowed 19 Plumbing Fixtures 900.2 Materials 904.6 .Freezing 850.7 Existing Adequate 1237.1 20 Heat Producing Equip. Prohibited Locations 1000.2d Enclosure .771.4j Air- Supply 1000.2g Vents and Chimneys Prohibited Uses 1005.2 Outlet Location Th 1-1005 Existing Adequate 1237.1 21 Electrical Metal Veneers 1030.1g Emergency Power 1032.2 Emergency Lights Th 1-1032 Exit Lights 1033 Existing Adequate 1237.1 22 Accessibility A117.1-92 Extdrior Facilities 1101.1 Interior Routes 1101.3 Interior Elements 1101.4 Areas of Refuge 1101.5c .Assembly Space 1101.6 Specific Occupancies 1102 Existing Buildings Part: 1236 23 Energy Requirements Energy Code Certification 7810.10 A-- ,,kc-441-r Tafe c 4,�- co,-4 1,-VT qj aw It Fly F