Loading...
RC-0733-2020 A C Office Use Only ADDITION ALTERATION PERMIT Permit#: APPLICATION `�b•`� Town of Queensbury permit Fee:$ =J 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.gueensbury.net �l Project Location: 10 East Branch Drive Tax Map ID#: 309.18-1-10.1 Subdivision Name: CONTACT INFORMATION: • Applicant: Name(s):Nick& Olivia Dunbar Mailing Address, C/S/Z:_10 East Branch Drive, Queensbury NY 12804 Cell Phone:_518-420-4315 Land Line: _( ) Email:_oliviamariex3@gmail.com_ Primary Owner(s): Name(s): Nick&Olivia Dunbar Mailing Address, C/S/Z:_10 East Branch Drive, Queensbury NY 12804 Cell Phone:_518-420-4315 Land Line: _( ) Email:_oliviamariex3@gmail.com Check if all work will be performed by homeowner only • Contractor(s): !i I NOV 2 5 2020 Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: _( ) Land Line: _( ) Email: "list all additional contractors on the back of this form • Arch itect(s)/Engi nee r(s): Business Name: Rucinski Hall Architecture Contact Name(s):_Ethan P. Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801_ Cell Phone:_(518-260-2888 Land Line: _518-741-0268 Email:_ephall@nycap.rr.com Contact Person for Building& Code Compliance:_Ethan P. Hall Cell Phone:_518-260-2888 Land Line: 518-741-0268 Email: ephall@nycap.rr.com Addition/Alteration Application Revised February 2019 r PROJECT INFORMATION: TYPE: ❑ Commercial Q" Residential WORK CLASS: Q'Single-Family ❑Two-Family ❑Multi-Family(#of units ) F]Townhouse El Business Office ❑Retail El Ind ustrial/Warehouse L/T Garage (#of cars t ❑ Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: _1,419_ 1st floor: 2"dfloor: 536 2"d floor: 3rdfloor: 3rd floor: Basement(habitable space): Basement(habitable space): Total square feet:_1,955_ Total square feet: ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $_$35,000_ 2. If Commercial project,what is the proposed use: woonw� 3. Source of heat: C/GasMOil❑Propane❑Solar ❑Other Fireplaces need a separate Fuel Burning Appliances &Chimney Application 4. Are there any structures not shown on the plot plan? ❑YES Cr7N0 Explain: 5. Are there any easements on the property? ❑YES Lr1N0 6. SITE INFORMATION: a. What is the dimensions or acreage of the par el? _1.01 acres- b. Is this a corner lot? ❑YES �1NC � c. Will the grade be changed as a resul�f the construction? ❑YES QN0 d. What is the water source? 1 PUBLIC El PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? �VAVA-t15- Addition/Alteration Application Revised February 2019 ,e DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: _Ethan P. Hall - Architect\Agent for the applicant_ SIGNATURE: DATE: IV` At Aga Addition/Alteration Application Revised February 2019 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) 'jjtj Two (2) full sets of plans Over 1,500 sq. ft. requires engineering stamp � e Design loads on plans: 115 Wind Floor Loads 40 psf (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties Light and vent room schedule_ Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for !v windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door Emergency Escape or Bedrooms & Habitable Space Above-grade: 5.7 sq. ft. Grade: 5.0 sq. ft. 24" (h)x 20" (w) minimum 44" maximum height above door Window control devices 24" or less 2"d story or 72" above grade UA11A Egress window from basement 5.0 sq. ft. Floor system sizing per table 502.3.1 1 e_kA•-,,J, A0_,<--VNr Residential check ERI or Prescriptive method All foam plastic on foundation &crawl space covered by 15 minute thermal barrier ttlk Driveway length: 300'.or more-12' width required/500' or more,turnaround required et Foundation drainage on plans, if required 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10' where required/joist spans pg. 127 Ice & snow shield—24" from exterior wall ti Platforms at exterior doors �;. Stairway headroom 6'8"; all stairs 36" width Stair run and rise l} Winder run and rise 1 Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Bathroom fixtures—proper clearance Hall width-36"width Handrails more than four risers on open sides ailing 8-guard > 30"/basement stairs included/closed risers more than 4" in height g notes for required areas r Garage fire separation:%" gable end/5/8" under living space &%" on walls/20 min. door h and closer Garage floor sloped Residential Plan Review Revised August 2020 Residential Plan Review: 1- and 2- Family Dwellings Attic access: gasket seal & R-value equal to roof insulation Roof over 30"—22" x 30"/Crawl spaces 18" x 24" access Y/N/ (2 of 2) Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected 1�5 within 15' of sleeping area Soil test results, if required Septic to well or water line separation All paperwork signed Note on plans energy saving light bulbs 75% Blower door test agency paperwork Floodplain Permit required—check map: 2 feet above flood elevation Hurricane clips required 14 roc Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel Dcr Manuals S &J required for heating system. Cold air return hard piped Separate room for draft HVAC or hot water heater with fresh air i&- HRV shown and calculations Baffles at eaves for insulations and knee walls -- wfz � Makeup air for range hood >400 cfm Continuous header for garage doors to end wall/3" nailing pattern/strapping Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised August 2020 -7 3 3- Generated. by RES.check-web Software Compl.ia-nce .Certifi:c ate . Project Dunbar Addition Energy Code: ode: 2018 IECC O Location; Glens Fallsj New York SED Construction Typeir Single4amily RE Project Type- Addition, Climate Zone: 6 (7635, HDD), Permit Date: Permit Number:. Construction Site:, OwnerjAgent: Designer/Contractor: 10 East Branch Drive Nick&Olivia Dunbar Ethan P. Hall Que,emiaury,NY 12804 10 East Branch Drive Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave 518-420-4315 Glens Falls,NY 12801 oliviamarlex3@gmail.com! 51&741-0268 ephall@nycap.rr.com 1@nycap.rr.corn Ce impliance: Pa5ses usIng UA trade-off Compliance:. 1.8%Better Than Cade Maximum UA: 170 Your UA: 167 The%Better or worse Than Code Index refiecti Row close to compliahce the house is based on code.irade-off rules. It 60E5 NOT prdvide an estimate of.energy use or cost relative to a minimum-code home, Envelope Assemblies 4brbss Ar6a Ca t Cont. As5;embly or 111vi y U-Factor UA R-Value R-Value Perimeter Ceilingil, Cathedral Ceiling 531 49.0 0.0, 0.022 12-1. Ceiling 2:.Cathedral Ceiling 357 38.0 .0.0 0.027 1-0 , Wall 1:Wood Frame..16"o.c. 856 21.0 3.6 0.046 -33*- Door 1:Glass. 36 0.2120 12- Window 1:Wood Frame:Double-Pane with Low-E 100 0.290 29 Wall 2;.Wood Frame, 16"o.c. 552 21.0 3.6 0.046 .22 Door 2:Solid 20 0.300 6 Winclow:9:WoodFrimtnDouble Pane With Low-E 56 0.290. 16 Floor is All-Wood jdistri7ru'ss:0Ver Unt-6nditicined Sjxate 380 38.01 0.0 0.026 .10 Crawl 1:Solid Concrete or Masonry 4, .ason60 0.0 15.0 :OiOST 17 Wall heigijit!5;9' D60th,below grade:,4.0' insulation depth::5.5' MAR 1 7 2021 TOVV,�! T Project Title?,Punbar.Addition ROdrt date: 03/16/21 Data filename; Pagel of A r I Compliance Statement: The proposed building design described here is consistent with the building plans,specifications;and other calculations submitted with the permit application:The proposed building has been designed to.meet the 2018 IECC requirements in REScheck Version:REScheck-Web and to comply with the mandatory re eme15Y Wth check Inspection Checklist. Ethan P. Hall-Architect r.'- •'s= M.&ZJ Name-Title Signa 8',� py�' �,n. "s c. �`', Date l i i { i i Project Title: Dunbar Addition Report date: 03/16/21 Page 2 of10 Data filename: I iI l RX Date/Time 05126/2022 09t32 15182731202 P,003 "May. 26. 2022k 9:03A ' MDIA— N0. 9373 P, 3 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. Toy. ,&that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Nick Dunbar Date: 05l10l2p22 Occupant: Same Location 10 East Branch Dr. Occupancy ervices Queensbury, Warren Co. NY Applicant: Nick Dunbar 10 East Branch Dr. Queensbury, NY 12804 D P Jose h A.Holmes No. 3.1801A15.0245E1,. _ _ _ - T MAY 262022 U LDI U Equipment_ - - - NG co�eSRY 21 -Switches; 36-Receptacles; 31 -Fbdures; 1 -30 Arho Receptacle;2-Vent Fans;43-Smoke Detectors; 1 -500 KW Electric Heater, 1 -1000 KW Electric Heater,2-1760 KW Electric Heaters;3-Are Fault Breakers 4�- ��~v'.� 2420— i his cettifleata applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and above and the installation inspected es of the above noted date based on a visual ownership as Indiceted herein. upon a change In Ilia use,occupancy or ownerzhip inspection, No warranty is expressed or implied as to the mechanical safety,efri- of the property indicated above,this certificate shall be immediately null and void, clency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle ed to,me fnVoduction of edditlonal elechiczl equipment and/or the replacement of Department Inspection Agency,Inc.to initiate the inspection an0 revalftlation arty of the components instalfea as of the above oared date,this tertifrcate shall be prods. A fee will be charged for this service. RUCINSKI-HALL ARCHITECTURE . Ronald Richard Rucinski Ethan Peter-Hall 1 M Dix Avenue Glens Falls NY 12801 Voice 518 741 0268 Fax 518 741 0274 Email ephall@nycap.rr.com .'. rr p UL' gVIE 10 East Branch Drive Dunbar Residence AUG .� 1 2021 TOWN OF QUEENSBURY 6 August 2021 BUILDING& CODAS Town of Queensbury Building Department 742 Bay Road .013'.� Queensbury NY 12804 Re: Installation of Replacement Sewage Disposal System At the.above referenced project location this office observed.the.installation of the new distribution box and gravity bed system. This installation is acceptable to this'office. If there are.any questions please contact our office to discuss: Re ards ���. U 9 <� ���`r a Etha a er.Hall Architect _ ' IX JJJ 1