Loading...
SEP-0461-2022 APPLICATION Permit#: �--�P �1,to.l, •?�Y7�?� Town of Quccn&6 , Permit Fee:$ Invoice#: 52.Q5 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.aueensbury.net Flood Zone? Y Reviewed B . Project Location: 9 WINGS FALLS COURT Tax Map#: 301.15-1-25 ,U V[�Y -VO\No OV g 00®ES RESIDENCE INFORMATION: BD��D-��" Year Built Gallons #of bedrooms: X gallons per =total daily flow perday bedroom Garbage Grinder 'Yes No 1980 or older 150 Installed? (choose one) X 1981-1991 130 Spa or Hot Tub Yes ' No 1992-Present 110 3 110 1.330 Installed? (choose one) X PARCEL INFORMATION: Topography ✓ .Flat Rolling : :Steep Slope % Slope- Soil Nature Sand Loam Clay Other, explain: Groundwater At what depth? GREATERTHAN.6 FT Bedrock/Impervious material At what depth? GREATER THAN 6 FT Domestic Water Supply Municipal Well Lake (if well or lake, water supply from any septic system absorption is Percolation Test Rate 1-5MIN per minute per inch (test to be completed by a. licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size Ex100o gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub EXISTING 1000 GAL CONCRETE System Absorption field w/#2 stone Total length: ft.; Each•Trench ft. Seepage Pit w%#3 stone How many: Size: Alternative System Bed or other type:20 FT X 30 FT Holding Tank System Total required capacity? ; tank size # of tanks • Applicant: Name(s): MATT WOODCOCK- Mailing Address, C/S/Z: 9 WINGS FALLS COURT, QUEENSBURY,NY 12804 Cell Phone: Land Line: Email: • Primary Owner(s): Name(s): SAME AS APPLICANT Mailing Address, C/S/Z: Cell Phone: Land Line: Email: Check if all work will be performed by property owner only • Contractor: Contact Name(s):SANITARY SEWER SERVICES Contractor Trade:, Mailing Address, C/S/Z:LUZERNE RD, QUEENSBURY Cell Phone: Land Line:518-796-3760 Email: "Workers' Comp documentation must be submitted with this application" • Engineer(s): Name(s): CENTER PROJECT SERVICES Mailing Address, C/S/Z:73 SHERIDAN STREET, GLENS FALLS NY 12801 Cell Phone: Land Line: Email: Contact Person for Compliance in regards to this project:GEORGE DRELLOS Cell Phone: Land Line: 518-796-3760 Email: NOTES: 1.Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency;2.We-will-.no-longer allow-systems to be-covered-until such-time as an as-built plan is received and "approved.The installed 'system must match the septic layout on file—no exceptions. 3. As= built drawings must be submitted prior to the inspection;.if there has been a change to the submitted plans.-4. If, for any reason, the building permit application is withdrawn, 30% of,the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100,1 of the fee-is retained. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinan PRINT NAME:GEORGE DREL S SIGNATURE: DATE: TOWN OF QUEENs.BURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist Plan to scale Received Deep hole pert test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) 0 All wells on property and adjacent properties shown ZWater line shown Municipal or well 10'separation to any part of system t'etback to property lines show 10'or more for any part of system Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline 0�Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) MSeptic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each Leech Field 20'from foundation 100'from any well 10'from water line �eepage pit 150'from well 50'from septic tank /N eepage Pits 3-times diameter apart I�Septic tank and pump stations over 30 gallons 50'from watercourse or wetland X4distance from bottom of trench or system 24"to bedrock or mottling 36"within 1000' of Lake George Leech field 100'from watercourse or wetland Yh—Toe of mound or bottom of retaining wall 10'from property line 100'from well 20'from Foundation Arovide Engineer/Architect stamp for bed or design systems e'Z_ — U� — kpepartment of Health Approval for all mobile home park new systems Flood Plain requirements ND�2' above established flood elevation to bottom of system �RAll tanks anchored or 2' above flood elevation 'D-,;..A All C/7!Y)7 309.15-1-25 SEP-0461-2022 E C E 0 W E Woodcock, Matt 9 Wings Falls Ct JUL 2 2 2022 f Residential Septic Alteration TOWN OF QUEENSBURY BUILDMG&CODES BUILDING DEPARTMENT Based on our limited examination,compliance with our comments shall not be construed as ! indicating the plans and specifications are in full compliance with the Building Codes of New York State. cl� a 1 i TOWN OF qUEENSBURY BUILDING CODES DEPT. U d B i ReveweY,/ p Date: a CENTER PROJECT SERVtCES 73 Sheridan Street,Glens Falls,NY 12801 Phone-518-796-2515 July 19,2022 Project#377 George Drellos Sanitary Sewer Service Queensbury,NY 12804 Re: Proposed Replacement Septic 9 Wings Falls Court, Queensbury,NY Dear George: At your request, we have reviewed your proposed replacement septic system design of the existing 3-bedroom house at 9 Wings Falls Court in Queensbury. As per our conversation the residence has an existing failed septic system. We have reviewed the proposed.replacement septic system design and we agree that a standard absorption bed is acceptable.Based upon a design flow rate of 330 GPD and a percolation rate of 1 to 5 minutes, you will need a minimum of 367 sf of absorption area. We recommend using 20 ft wide by 30 ft long absorption bed with 4 —25 ft long laterals. The absorption system can be constructed with the existing 1,000-gallon septic tank, new distribution box, and 4-inch diameter perforated pipe and stone. Please feel free to contact me at 796-2515 if you have any questions and that you for your assistance with this request. Sincerely, Thomas R. Center Jr,P.E. D E � Q � rJ JUL 2 2 2022 TOWN OF QUEENSBURY BUILDING&CODES V R 1t1tt f I 1 ! r I 1 f � ' t I i t i f j 1