Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2002-755
r TOWN. OF:QUEEN.SBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes- (518)761.8256 'CER.TIFICATE OF OCCUPA,NCY Permit Number; P20020755 Date Issued:,." Thursday,June-02,2005 This is to certify that work requested to be done as shown by Permit Number. P2:0020755 has been completed. Tax Map Number: 523400-296-012.0001-037-001-0000 Location: 25 WILLOWBROOK Rd Owner: SCHERMERHORN COMM,HOLDINGS,LP Applicant: GLENS FALLS HOSPITAL MEDICAL OFFICE CENTER This structure may be occupied as a: Commercial i Industrial By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020755 Application Number- A20020755 Tax Map No: 523400-296-012-0001-037-000-0000 Permission is hereby granted to: For property located at: BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GUIDO PASSARELLI Commercial/Industrial 585,000.00 465 LAKE Ave Total Value 585,000.00 LAKE LUZERNE,NY 12846-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications BP 2002-755 Medical Office Lots 2, 3, and 4 to be consolidated within the Baybrook Professional Park: Schennerhorn Construction and Ownership of Richard Schermerhom is under contract. Construction of a 35,368 sq. ft. commercial building(Medical Office) as per plot plan and specifications. Tax Map No. 296.12-1-37 will be the main identification(296.12-1-31 and 296.12-1-32 will be deleted as per R. Dixon(Warren Cty Real Property Tax Office). Address: 25 Willowbrook Road $5,305.20 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,September 06, 2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To n of ptember 06,2002 SIGNED BY �&;v IA�' for the Town of Queensbury. Director of Building&Code Enforcement _ - Building _Ferm:a Appl � <,wn of Qucensbury—Dept of Community Development, 742 B Roa s ', (518)761-8256 rr 0 :r.. A ermit must be obtained before beginniics[E? tion. Permit File N _ spection will be made until applican ed Free Paid $s,Sa building permit. All applicants' spa P ec. Fee Paid'_$ - - aglication must be completed and must appear on the Reviewed By: application form. O AlWicant: . Owner: SG�a.i.�.��,e�-` nL3/o Address: 15" F Address: Y r-- l3it- ' z-_ - 's dut-�Z , AV-,y PKane#(s/S )-7qr -CC-7 Phone 0 P perty Location: of Number: '! Hou z=ber S tf6division Name: C New Building: residence �erci. Estimated Market Value bf Construction: $ ❑ Addition: residence/ If an Addition,what will use of new addition be? z ❑alteration: residence/ commercial ❑n o change to exterior size: residence f com'I ❑fi`Other work(describe ) ' ! 49heck OccupancyInformation 1"Floor 2" Floor Other floor Total Dial ow sq.ft. sq.ft. sq.ft. Square Feet w c �❑ Single family dwelling ❑ Two family dwelling r ❑ Townhouse ❑ Multifamily dwelling #of units ❑ Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage �a ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage ❑ 2 car attached garage ❑ 3 car attached garage ❑ Storage building- commercial d Storage building- residential. ❑ Other / y"J_ l -74 $`f 3 3 What is the proposed height of the structure 8 d feet /0 inches %1l Will any second-hand or ungraded lumber be used? If so, for what? o Type of Heating System: electric/ oil / gas/wood ,Plforce�ir/ baseboard/other: Number of Fireplaces to be installed V Number of yI'oodstoves to be installed iD List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder sc 4 /,K v Plumber Ce l�s 7�Z —30o Z, Mason G,l c. 2.ESa— t2�t'z. Electrician A,sa, z 60 l Sl Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of allcons coon. Signature: owner,owner's agent,architect,contractor ENERGY CODE COMPLIANCE APP?3: ATION t p • TOWN OF QUEENS' BU'RYi WARREN COUNTY 9000 HEATING DEGREE DAYS AUG 2 9 2002 Comoliar_ce Methods: PART 5 - Acceptable Practice MethoUOJ I-ffi,OF Ur NSm� Y 1&2. Family Dwellings '(only 3 irk-�;;�� ,n t PART 6* - Thermal Rating Component Trade Offs--=- 1&2 Family Dwellings; Multi-Family Dwellings (3 stories or less) PART d* i Design by Component Performance Commercial Buildings-Hi Rise Residential *Require's submission of worksheets APPLICANT'S NAME: PROPERTY LOCATION: S c c G+ V" 2,r w PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: I . ' Gross Floor Area - 3 3/$ square. feet 2 . Tvoe of Heat - Electric Oil Gas Other 3 . Is building n%echanidally cooled? _ N�- Yes No 4 . Percentage of area of widows and doors Over 17% Under 17's 5 . R-V ILUES FOR INSULATION GIVEN BELLOW MUST. CORRESPOND TO R-VALUES AS SR0'r7N, ON PLANS SUBMITTED: a . Roof R 3 b . Exterior walls R c . Glazed areas. R 3 d . Exterior doors R e . Floors over unheated' spaces R W4 Edge o-E slab on grace (heated building) R a. Basement/cellar wail's (above grade) R �+ : Basement/cellar walls (below grade) ' R jo _ . Heating/cooling-ducts-pi.p i ng in unheated space R 6 . Service (domestic) hot 'water heating device' ' Con=orms to mi :_raum efici ency per code C_ Yes No TEMPERATURE CONTROL MAXIMUM SETTING 1400 - WILL NOT BE EXC;EDED Aoio lca-u ' s at re D2 t-e Phory, ee r6 7 REMARKS: Application for Permit—Septic Disposal System Town Of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER NVORMATION: ................................................... ........................................ 7. se Location of installation: ce7*4 Ree r r zmt 1-�90',WL Tax Map No. Fee Paid Owner's Name: ..... 920 .......I——........................ 9.2................................ Address: TOVVAJ OF Q111c-ENSBUpy 2, INSTALLER'S NAME e,- PHONENO-7-7X-- 7-ye 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate 4 bedroom(s) and multiply# of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Beftgras x Comoutation = Total Pail�Flow 1980 or older x 150 gal/bdrm = 1980-1991 x 130 gal/bdrm = 1991 —present x 110gal/bdrm Garbage Grinder Installed yes no Spa or Whirlpool Installed yes no 4.'- PARCEL INFORMATION: (circle applicable information&indicate measurements) TQRogmphy Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply Flat sand at what depth at what depth municipal Rolling loam feet —feet well Steep slope clay if well,water supply %slope other from any septic system depth: absorption is_ft. other, Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per Inch 5. PROPOSED SYSTEM: For New Cons gdga: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: gallon (min. size 1,000 gal) Tile Field: each trench —ft Total System Length: ft Seepage Pit(s): number of size ofeach: ft. by Size of Stone to be used: depth or thickness feet Bad System Size: Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number oftanks: Size of each: gallons t TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspe6tion agency. 7. 1 SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval jrWnted which is based upon or is granted in reliance upon any material misrepresentatioil or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town f Queensbury Sanitary Sewage Disposal Ordinance. 839nal of responsible person 17 to .. :'1'ntiv'tt of t2tta:t_sswtsiii-y 5etv:if;c: I)isjs< sal Chapter SI Ply RNI-It,)N Ii-FAIIA R I i;.N'I'S POND '. �• - ll'JF_l.t_ iN t//ITF.'Ft,- �� r/���„/ F_L Lt'ta•! . t1t}tIT CA51tlQ ._.� • T �. � l�.,.,,, r-• 7l�t tY� �t �• �—..� J ,�i�•' �x•,f_ 1 (Jiro IMI t IItt•t t t+fYrrntPt�t s ROAM 7. SIGNATURE 8c INFORMATION FOFC RY-51"OMS"Al.:r rnr-o..,L, wwv-a......,.�•• . COMMONWEALTH ELECTRICAL INSPECTION SERVICE, INC*�00 Main Office 176 Doe Run Road - Manheim, PA 17545 MUNICIPAL CERTIFICATE • ELECTRICAL APPROVAL � Pem t No, If,},,,,}►!1!},!„l.ui.,il.,i,..,,,e„ e , 7 0 7 Cut-in Card No,111rf1,1►,1,,,I,,,r,,,1}}„}}!,{}}, 904t%u �/ ►I t���f fltf►ftrl},trrrriii►{if,t,s{tlifiNlittttf,iN,t}1t}41}}!i}it},i►,fii,lptlffltill!!R}HIt„{!,l,lH,i,t!„fttt}}tt}}lliiq}f i,lfittgf ,fllNtftlllNi{ff{fHpt{tilt Location tRftllrtrl to f„eelt,t„etftellretfNflfttNt,Ittlttllei►rr,►,i►i,1 }�,le,fa,u,r,rlN,Nee ,�,►l,ln,lft now installation Consisting Vflf!liflNii{{ttltflltttfttilfi!! 11 (41oM#1 #11 ##16Jif{• 11Ff •ft{}!t!f!!}}ll/,it,N/111tt!}f}t„ 4 lffNf Wdis !f„„r1,►111N }►♦Ieillle!# R,,,„to#N{i„1,tlr! lfilliiqlfifl,!„i1r,1}„1!!,{fittlffiiflflfl!!!tlfttrrtri„ili!lillf{{N••Itl1 gigolo iilf,iiliitilf!!f iillfi14,H1ro Igo f fell ti Ito iili1rl11fi 11141{1til,vititi11et1N11itit{1e,f11NiH11itNtHlHlttl,,,1,N,tlif}tilNee,til�iti,ellfllNlrHi}}„ffNlifHilf!!le,,t1„r„#lN,iflRN! InstalledBy#1o4141&6A41o11##*1A#§ fltfre,,fil,/r,i li lffillelff fftletlf rffif!lffttf rfrl„11li/Neff Lice No. t1lt,ftlt,i„,l,{,111 Hit►/Net„t„l„!Nlf,1,1+ The conditions following governed the issuance of this certificate, and any certificate previously issued i! cancelled: - This certificate only covers the electrical equipment and installation conditions as of date, Upon the introduction of additional equipment or alterations, application shall be promptly made for inspection, lnspectors of this Company shall have the privilege o5a,,,, ' spections at any time, and if it rules are violated, the Company shall have the right to re se f icate, py �'0iN; m` f ffeilr!• ffefl,lllr,il,ril►/N! I• " lfr iftrftfit ,► ►11►eftf}fll.Rittif,►►IN,!{„I,N{ielfll,},iffiilili{f{iflifl!• Member N{ I ''& I}A/F.I! Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspe111c ion request received: Queensbury Building&Code Enforcement . 4 am/pin 4 Depart: am/pm 742 Bay Road,Quee sbury NY, 12804 Inspector's Initials: NAME:. jCR,PERMIT#: LOCATION: ��ATE: COMMENTS: Y N NA Chimney/"B"Vent Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in,-38 in./Step Risers 711/Treads I I" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 1/2doors > 10%> 1000 sq. ft. 3/4Hour Corridor Doors&Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars-LSiaks/Toilets Handicapped Bath/Pa Lot Sig,nage, Public Toilet Room Handigapped-A-Cc—essible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if reg. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by qaLLDrixkable Surface 201 wide— r rler-maneg[!��K Okay To Issue Temp. 04 V Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc } COMWERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received:, Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrivdilu am/pin Depart pm 712 Bay Road Inspector,�s Inut, s Qtaeensbury, NY 12804 l// NAR E �,�-. � PEI #� LOCATION DATE 3 JP TYPE OF STRUCTURE N/A YES NO CONINIENTS ChimueyP'B"Vent/Dired Vent location Plumbing Vent Roof Complete Exterior finish grade complete hgaior/exterior guardrails 42 in.platform/decks Interior/exterior ballasters 4 in.spacingplatform/decks Stair handrail 34 in.-38 in. Step risers 7 3/a in. Alain door 44 in. All others 36 in. Lever handles Exits at grade or platform Candy to cover req.exit doors Gas valve shut-off exposed®ulator(18 in.)above grach Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut offwithin 30 ft<or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3h hour door Storage/receiving/shipping room(2 hour), 1 '/z doors 1 112 hour doors and closers 14 hour corridor doors and closers Firewalls/frre separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shufiers 1 1/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required_ Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) ` Okay to issue permanent C/O(Certif.of Oc upancy) Okay to issue C/C(Certif.of Compliance) Z•o wN o f Q U E E N S B U R Y BU x LIJ xNG S. CODE ENFORCEMENT 742 BAY ROI1n - QUEENS 8 U R Y N Y 1 2 8 0 4 (518) 7i61-8256 A RR x V E : DEPART : x N S P C;e& �'xP7.7�L ZP7SPECTSON REPQAT CCfPfiMERIC2�1L ....,--.------ MTJLTIf"LE 11WELL�I+it3 (hotel. rnc►t�l. apt_ cc7rnple-x) DATE xNSP E TxC)N EQUE RE xVED LOCr�T xal ���'� � '�---•` nA� # 'I'YPM C?F S T RUCTUiZE FC1C)'x X NGS F3AC:KF'I LL xNG PIJiIMB xNG x NSLSL�T1`i�zQN raf� Yes ivcv CHxMNEY/ " B " VENT/fiExGHT P LUM S x NG VENT/F x X T U RE S RC?CIF S NG - EXTERxC)R FxNmoll HEATxNG/FiQT WATER RE L x E F VALVE S FLOOR S FOL7N DAT x O N x N S U LAT x Q N xNTERxC)R S`I'AxRS/RAxLxNGS S TO C K RO QM E N C LQ S U R E FIRE/DEMISE WALLS PENE'IRA'rxQN FIRE nAM P E R S C E x L x N G F x R G S TO P P x NG FxRE L)OQRSlCLOSERS EXxT DC)C)n HARDWARE E X:E IJLI P`LATFOZZ.M ELEVATQR H AN D x CAP P E D AC C E S S I3ANC]xCAPPEn BAiriiS iiAN D x CAP P E n P ARK x N G PLAN VARxi4.NCE RE op 14 2k, SURVEY PLAT PLAN xF RE QK TQ ZSSUE C C) OR C C 1ssc/e s s cl o vfs MAP REFERENCE: BAYBROOK PROFESSIONAL PARK DATED JANUARY 31, 2001 LAST REVISED MAY 9, 2001 BY VAN DUSEN & STEVES LAND SURVEYORS, LLC FILED IN THE WARREN COUNTY CLERK'S OFFICE ON JULY 25, 2001 Dm ► ►wvL Wv%- - - WALKER LANE BAIBRIDGE ACCESS RD. 76.6' z I 0 W Om _. C W � OC 0 I O 3 77' S83 09 00"E 269.14' n ev v� 4�11 N83'12 52"W 58.18' i v AREA 209,668 sq.ft. 4.81 acres oJi2, a 04 Taw Vl ?4 _o 0 x 10.) po q � a � W � 0 u ow Al z 04 0 x 0 W E w x N .y 0 .•4 u ti z z :3 rin ^1 W 0 q R A 0 or z n 1W, T � t� o a r m � DWO scale T- w S 1 G EEr 1 OF 1 D-593 DWG. NO. 90276-4 PROTECTION SYSTEM NEW YORK FIRE & SIGNAL CORP. INSPECTION REPORT* 4 Glens Falls Technical Park Glens Falls, NY 12801 e—DATE OF 0 WORK ORDERED BY ?ML I o (518)798-9551 ORDER TAKEN BYJ PHONE Fax(518)792-5199 P.O.NO. JOB NAME11, ATION KL I0104 �INS,7ALLrOj DATE LAST INSPECTION� j 02 i INVOICE DATE JOB PHONE 0 pv 'A ':SY STEM INSPECTION SYSTEM EQUIPMENT MANUFACTURE INFORMATION 1�7 ao SYSTEM INSTALLER R.O.R. *14" Fixed Heat SYSTEM APPLICATION Photoelectric TYPE OF SYSTEM [on Duct MAINTENANCE PROGRAM BY Flame ❑ CALL LIST UP TO DATE Yes No Manual Cross Zone REMARKS Single Zone Contacts Motions A C Photobeams -AWA Nk MU TION&D CONTROLFAN9� ENTT: v, Water Flow Low Air A.C.Voltage A.C.Voltage Weight V-1 Sprinkler Tamper D.C.with Load Last Hydro A D.C.Voltage D.C.without Load Gauge Pressure D.C.without Load -T Air Hand. V"' Serial# yiJ tC ri- Door Release Duct Damper Equipment ShutdownVIVAL V [IA.C.Voltage 141 T7' D.C.Voltage Battery 'V/ Detection Circuit A Audible Circuit Remote Activation Audible Devices I tits Visual Devices Pre.Discharge Signs As Needed 777 7T Selector Valves Piping Nozzles y. Tanks Gauges s, INSPECTOR Piston Activator C.6 I hereby acknowledge the satisfactory completion SYSTEM FUNCTIONAL Solenoid of the above described work, Manual Release , El SYSTEM NON-FUNCTIONAL 7t� Time Delay Remote Station Trans. ❑ DISCREPANCIES Digital Dialer NOTED ABOVE Voice Dialer t Phone Line Signature{Title) Date FIRE-ALARM SYSTEM CHECKLIST Date: Name: $al aw fl'c OLD Location: NIA YES NO Fire alarm system plan and facility layout provided Manual pull,stations visible Fire alarm panel room has proper desigtration.on-do Confirm receipt of alarm at central station (supervise Local fire alarm signage posted Zone chart posted - , Tamper and Flow switches tied into alarm panel Hood suppression tied into alarm panel Affix do not reset sticker to panel System test ; Pull station. Smoke detector Duct detector HVAC shutdown Inspector. ' ' COMMERCIAL FINAL INSPECTION REPORT � Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 (Dept. of Community(Development j Town of Queensbury Arrive 12� andpm (Depart �n 742 Bay Road Inspector's Initial Queensbury,NY 12804 L erne f rrrr- NAME � �? z.�� PERMIT# LOCATION 91it DATE 3 �3 TYPE OF STRUCTURE N/A YES NO COMMENTS CnimneyP'B"VentlDirect Vert location Plumbing Vent Roof Complete Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks hictior/exterior ballaste s 4 in.spacing platform/dedcs Poo Stair handrail 34 in.-38 in. /Step risers 7 3/.in. ?`Lain door 44 in. All others 36 in. j /elf kE fS Levy handles fin g J2 6( /s` r I Exits at grade or platform Canopy to cover req.exit doors Cras valve shut-off exposed®ulator(18 in.)above gradi / Hoar bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(I hour) >1,000,000 BTU's(2 hour) Gras furnace shut offwithin 301 or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(I hour),'/.hour door Swragelreceivingtshipping room(2 hour),I '/2 doors I "hour doors and closers 3 4 hour corridor doors and closers FirewalWfire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signagg Handicapped bathroom grab bars/sinks/toilets Handicapped bathiparking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond .-fictive listening system and sigiage assembly space Final Electrical Site PlanNariance required_ Final Survey,new structures .As-built septic system layout required Okay to issue temp.C/O(Certif of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Cectif.of Compliance) Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 � fax 745-4437 (� firemarshal@queensbury.net Fire Marshal's Commercial Inspection Ile ort Name �c Address 7-1 A Date Time O V am m Inspector nkler.Sys Suppressio tem a Afar Y No Wet ised Y o Ye Nd� o al spection Date Jt' Inspection ate nspection Date NOTICE:As the property owner/manager,I understand that this inspection is required by law,and that I have the right to refuse entry into/onto the property for the purposes.of conducting this inspection.I further understand that by granting permission conduct this inspection,I agree-to abide by all applicable laws;and further agree to correct any violatio the law specified herein within a reasonable amount of time from e date of this inspection. Signed:_ Applicable Code Section Comments Fvu VAO- 3 ci� A&WL44 LIX.) 1' 06MS s 15Cu55� C7 ,f' "w o�� I a 0� eel• t White—Customer Yellow—Fire Marshal Pink-F) COBUAEERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury ArriveA Ll>am/pm Depart am/pm 742 Bay Road Inspector's Initials Q Queensbury,NY 12804 f NAME �• tu'- cC%1 PERMIT# 0 M—l ", LOCATION , r r DATE TYPE OF STRUCTURE q7/ N/A YES NO COMMENTS ChiumeyP'B"Vent/Direct Vent location Plumbing Vent Roof Complete Exterior finish grade Mete laterior/exterior guardrails 42 in.platform/decks [ /f / Interior/exterior ballasters 4 in.spacing platform/decks _ tb `e, � NeG Stair handrail 34 in.-38 in. Step risers 7%m. Main door 44 in. Alt others 36 in. ) / Lever handles `� lZ l� lk- ,�/j 4�rli Exits at grade or platform �J" Canopy to cover req exit doors Gras valve shut-off exposed®ulator(18 in.)above grade Floor bathroom wateatigltt - J or, Other floors okay � �/.- a c�i1�S Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(I hour) >1,000,000 BTU's(2 hour) U Gras furnace shut off within 30 1 or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage ireceiving/shipping room(2 hour), I '/2 doors I °i hour doors and closers 3 4 hour corridor doors and closers r� / Firewalls/fire separation,2 hour,3 hour complete 1' Iti J S4 ?ewl Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 %2 hour,3 hour �' /' ' �J. �=j 40 r Ceiling fire stopping 3,000/5,000 sq.8. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required _ t Final Survey,new structures .A---built septic system layout required Okay to issue temp.C/O(Calif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) Itis A United Technologies Company FINAL ACCEPTANCE city u b u Q OTIS ELEVATOR COMPANY Date �/ /0 3 Ladies and/or Gentlemen: We have)examined the Elev for furnished and completed by you in C Q�}rt WA v r& � Q l� Building in this city. The elevator appears to be satisfactory and in accordance with your contract and we hereby accept it. Note: Elevator Cab(enclosure) and Hoistway Entrances have been thoroughly inspected and found satisfactory. �j Yours truly, Sales No. � 79 1 �1 p (Company) By Y Contract with 1 ature and title of person accepting) SCE -ems ei'ho�,�/ 0�1 By (Printed name of person accepting) KEY ACKNOWLEDGMENT The following keys,necessary for the proper operation of the above named elevator,have been turned over to me along with complete instructions on the operations of the elevator. QUANTITY QUANTITY Emergency Side Exit Keys Lobby Panel Keys UTA Keys Emergency Door Key(Under Glass) UTF Keys Utility Cabinet Keys _ UTB Keys Hoistway Unlocking Device(w/Brochure) Light Switch Keys O.M.M.S Manuals _ .Fan Switch Keys I m y u T OTIS SERVICE EQUIPMENT Any counters,meters,tools, remote monitoring devices,or communication devices which we may use or install under this Contract remain our property, solely for the use of Otis employees. Such service equipment is not considered a part of the Units. You grant us the right to store or install such service equipment in your building and to electrically connect it to the Units. You will restrict access to the service equipment to authorized Otis personnel. You agree to keep the software resident in the service equipment in confidence as a trade secret for Otis. You will not permit others to use, access, examine,copy, disclose or disassemble the service equipment or the software resident in the service equipment for any purpose whatsoever. If the service is terminated for any reason,we will be given access to your premises to remove the equipment, including the resident software, at our expense. CUSTOMER-PLEASE NOTE THE FOLLOWING: The New Installation Service(N.I.S.# }will begin immediately and will continue for months. The warranty period will begin immediately and will continue for months. Should any problem develop in the operation of this elevator, please call Otis Elevator Company at 1-800-233-6847. (Operator will request the name and address of the building,and a elevator number--should there be more than one elevator in L SIGNED: By (Company) erson Accepting) Form 426(REV 3199) w COMRsRCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development . Town of Queensbury Arrive X> am/pm Depart am/pm 742 Bay Road Inspector's Initial- ' Queensbury,NY 12804 NAtv1E �Gr a•�e� r� e dt,,4 ��Ll PERM[T# LOCATION ,2 L� DATE L D� TYPE OF STRUCTURE N/A YES NO COMMENTS ChinmeyP'U'Vent/Direct Vent location Plumbing Vent Roof Complete �Z- Exterior finish grade complete 74. s hucrior/exterior guardrails 42 in.platform/decks hiterior/exterior ballasters 4 in.spacingplatform/decks Stair handrail 34 in.-38 in. Step risers 7 3/4 in. Main door 44 in. All,others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gras valve shut-off exposed®ulator(18 in.)above gracbh[s /�IfGUr Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 301 or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/s hour door Swrage/rec eiving(shipping room(2 hour), 1 '/z doors 1 =4 hour doors and closers '4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot sigrage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond .-fictive listening system and sighage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures .As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Oc upancy) Okay to issue C/C(Certif.of Compliance) )1h CO1bImERCIAL F'INAL.INSPECTION REPORT Building& Cade Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrivedm am/pm Depart am/pm 742 Bay Road Inspector's Initial- Queensbury,NY 12804 NAME PERMIT LOCATION DATE b-- TYPE OF STRUCTURE N/A YES NO COMMENTS ChinmeyP'B"Vent/Direct vent location Plumbing Vent Roof Complete G L.J .,/e - 3lx Exterior finish grade complete lurerior/exlcrior guardrails 42 in.platform/decks ry Interior/exterior ballasters 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Step risers 7%in. fl1 Main door 44 in. All others 36 in. )1, �e�4#M2z/� ('LY7ms Lever handles Exits at grade or platform / Canopy to cover req.exit doors (/2ti Gas valve shut-off exposed®ulator(18 in.)above gradAff Floor bathroom watertight zt SA/lrl /7% , Other floors okay Hat water relief valve Boiler/fiamace enclosure <250.000 BTU N/R f 250,000 BTU to 1,000,000 BTU's(I hour) j >1,000,000 BTU's(2 hour) �f- ec C � lk� Gas furnace shut offwithin 30 fl.or within line of site C1 Oil furnace shut off at entrance to furnace areaUrJ ,t l«t/eit jYJ/S,f Stockroom enclosure(I hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 1/z doors U/0S c /f 11,i hour doors and closers ! `r j �`` /`/� r�' ���i ?4 hour corridor doors and closers v .•�' Firewalis/fre separation,2 hour,3 hour complde �S �` �!-xS/ 11�t1r6/r5 Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. P rmv/64 Jj l/ Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware (� Elevators Elevator signage / Handicapped bathroom grab bars/sinkshoilets f" Handicapped bath/parking lot signage //.I Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond 4— j� / •w .�` . ive listening system and signage assembly space �G ,' G / Final Electrical Site Plan/Variance required _ Final Survey,new structures .As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif of Occupancy) Okay to issue C/C(Certif.of Compliance) 4�� COMMONWEALTH ELECTRICAL INSPECTION SERVICE,,IN Main Office 176 Doe Run Road of Manheim, PA 17545 � MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Pem'tNot Cut-in Card No,fffffffitffilf�/ifltffilffifftlf ff Owner,,,,,,,,,I off###R i goo f lost#{H Iota iftimsa l I#$##so fiHiffiflfpiffilftif oft llilN l ltt AN ttii{tft i i{tlf+ffHfNffiiiiiN{{{$$1##Aat#*###111lffiitit tonal too l afoot it fi Locationlpf,@fiNfN@11#fsef#,fool,i@••it#l11t„NIN#e!@toolsfellfflaloof,NNN#ft#i##o11#tell,NiRRRR!!RR►RlllRliRfitlRlifl►NliffifilR! fRf#NtNif!#1 follis,1 0 1 70 �aff V lel IS R '�Installation Consisting ofNlaliti,111/r#f1N111e1NNff@1NN.@f fir i###INiN.eNa#faalN1N1t1f{►!+ tflagogltfililllHiltlflff@{fiNN@ff11N# eff##NI (0 /fN 11lf!!Nflalf!ltMfl i!!@!iH#(Il• 6� 6#1 itflitlN/tlgffnl+ a Imsittli@Mtotf#1 HIM166 11H1N/g@if fee##N@@@H{ft!lf Ifeet to 11f091 off I NNs I NNif@a total tiff@1VNN1#a@t#@#N#as MvmNiHNNff 011mee 601101ii{ogle l to 111#19 Its fool f if EW P4 4 1 Not Installed B/Jteioi fiffooittil/t{i flatfeet if6#66{t ioi{tf Beal/l Nllifii hots fi/fitlf l off It##@ l Boost#@@ tfLie# ififffffilfitettff feffff tififfifflt1f N11flfilll The conditions following governed the issuance of this certificate, and any certificate previously issued i cancelled: This certificate only covers the electrical equipment and installation conditions as of date. Upon th introduction of additional equipment or alterations, application shall he promptly made for inspection, Inspectors of this Company shall have the privilege of pthicei ' pections at any time, and if il rules are violated, the Company shall have the right to r okecate "")P., 5lT � ('�TniJ"�' �/�fDatel#Iaf#!#famtI##ValeItogoftooffmo iNiiNttiii IN PECTORtrait,,#N H{#'f#NNNisrfN{#iN#oolN##NNN!##tfil!llaiifllllll#oioN# Mcmhor N Ti p d TAYI Rough Plumbing / Insulation Inspection ort office No. (518)761-8256 Date IiIspection re es -;)rec iv d: Queensbury Building&Code Enforcement Arrive: -a pm/ art: ?2 742 Bay Road,Queensbury,NY 12804 Inspector's Initia s: NAME: e):P�RMIT#: 7==Q=— LOCATION: t,3 INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3, R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft.above,highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\PamW\Whiting\Rough Plumbing Insulation Report.doe Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit# d�" 7S� INSPECTION ON: a Name: 0-743°`D P 61) Lo `C, PM ANYTIME Location: �°"� �� APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS L t it C U r=1� S EXIT SIGNS—NORMAL - BATTERY C (�S •sc� 4L�2c,—ct�:cinCV d EMERGENCY LIGHTING _ FIRE EXTINGUISHERS ©,YV I-i S FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM sy 5-q� 't HOOD INSTALLATION INTERIOR FINISHES P' PAD ��"' ��' STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS �� r Cz7t1�e'IG 1 S(� `�j S� '�tY;`�` C CLEARANCE TO HEATINGS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGNS CHIMNEY MASONRY ROUGH IN #- FINAL - CHIMNEY FACTORY BUILT ROUGH IN FINAL .�-- ?c-,1=;tiWOOD STOVE ROUGH IN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE 4 _•._. MASONRY ROUGH IN OK THIS DATE K OR CO LNOLO� FINAL f FIREPLACE FACTORY BUILT ROUGH IN INSPECTED BY FINAL COM13EV/CHRISJlWORD/LETTERS2001/FIREMARSHALINSPECTIONREPORT102200YELLOW-OCCUPANT COPY WHITE—BUILDING DEPARTMENT COPY COMMERCIAL FINAL INSPECTION REPORT 9Building& Code Enforcement Date inspection request received: ! /� Office No. (518)761-8256 Dept. of Community Development Town of'Queensbury Arrive-Vir am/pm Depart pm 742 Bay Road Inspector's Initials�� Queensbury,NY 12804 } ] NAME $_y l PERMIT# Oa LOCATION i CS1D DATE "TYPE OF STRUCTURE N/A YES NO CON54ENTS Chimneyr'B"vent/Direct vent location Plumbing Vent Roof Complete j , fit Exterior finish grade complete � Q lmerior/exterior guardrails 42 in.platform/decks Interior/exterior ballast rs 4 in.spacingplatform/decks Stair handrail 34 in.-38 in. � %+ '!C jO t-7 Step risers 7 3/4 in. �✓ Main door 44 in. ,all others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gras valve shut-off exposed®ulator(18 in.)above gracb Floor bathroom watertigtrt Other floors okay z Hot water relief valve Boiler/furnace enclosure <250.000 BTU N/R ,skiff � �,� f ot<Q.r��ll2f 250.000 BTU to 1,000,000 BTU's(I hour)>1,000,000 BTU's(2 hour) � 44- /ti rletx/11 Gas furnace shut offwithin 301 or within line of site --f' Oil furnace shut off at entranceto furnace area / j'� Stoc�avom enclosure(I hour),3/4 hour door I t�e Storagelreoeiving/shipping room(2 hour),1 '/-doors f l 11,i hour doors and closes ?4 hour corridor doors and closers_ Firewalls/fire separation,2 hour,3 hour complete f .C- l�G Iw Fire dampers,2 hour fire wall/separation or greater 1r1 Fire door/shuders 1 1/z hour,3 hour 6 /sL Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators r � Elevator signage "�` Z' �� Handicapped bathroom grab bars/sinks/loilets J � Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. I l J J ✓ ' Aoo Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage asssembly space Final Electrical rr Site PlanNariance required �A/`f I J//c Final Survey,new structures /hClJi✓t As-built septic system layout required _ r�,f� �,ww� S J a,o•.r��� Okay to issue temp.C/O(Certif.of Occupancy) Sewer J ,(� Okay to issue permanent C/O(Certif.of Occupancy) YJ�lrs4 7'UU) Okay to issue C/C(Certif.of Compliance) 5t Viv hs�r �>�� D2ji wJ d- rfr �7S ,t SeJrta l Sys Ce-t�r�,�u lip Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection requ r ceive 3 Queensbury Building&Code Enforcement Arrive: i.9p rt: 742 Bay Road, Queensbury, NY 12804 Inspector's Init*I NAME: S � . /�,�'F-- � ' PERMIT#: LOCATION: ' S [ INSPECT ON: D TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour - -- oppmg Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X — � Garage side 5/8 inch Type X4� :�1 1y � -- Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\BuiIding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing 1 Firestopping Inspection Report Office No. (518) 761-8256. Date Inspection re u cei Queensbury Building&.Code Enforcement Arrive:. —a e r QDa pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initia s. NAME: ERMIT#: � LOCATION: TSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS , Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 Stairwells 36 in. or more Headroom 6 ft. 8 in. .Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts'6 ft.or less on center Ice and snow shield 24 inches from wall - Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour estopping - K Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X . Garage side 5/8 inch Type X . Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in:(W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Fra ring Firestopping Inspection Report.doc January 28,2003 Framing / Flrestopping Ins ection Report p p Office No. (518) 761-8256 Date Ins ection re ues eived- Queensbury Building&Code Enforcement Arrive: a D ``� a 742 Bay Road, Queensbury, NY 12804 Inspector's Init' NAME: (y"' PERMIT#: CQ LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N NIA COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000.sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire all 2, 3,4 hour Irestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation - House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingtivaylBuilding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report r j�,�..: Office No. (518) 761-8256 Date Inspection reque receive Queensbury Building&Code Enforcement Arrive: a p rt: A "All a pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: PERMIT#: c z- Wr LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6:ft. 8 in. Stairwells:`36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping V ,, Penetration sealed �. 16 inch insulation in cavity min. Garage Fire Separation i House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in: (W) 5.7 sf above/below grade 5.0 sf grade L ASueHemingway\Buiiding.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: /l Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive-A-0 am/pm Depart pm 7.12 Bay Roast Inspector's Initial. Queensbury,NY 12804 / / NAME Sc 1?fn er l d r- PC . 1 6 PERMIT# LOCATION 1,J,flu,1,,a L P1 DATE 3 TYPE OF STRUCTURE N/A YES NO CONM EENTS CnimneyP'B"VentA)irect Vent location Plumbing Vent Roof Complete Exterior finish grade complete Dior/exterior guardrails 42 in.platform/decks Interior/exteriorballasters 4 in.spacing platfonn/decks Stair handrail 34 in.-38 in. Step risers 7 3/4 in. Main door 44 in. All others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gras valve shut-off exposed®ulator(18 in.)above gra Floor bathroom watertight Other floors okay Hot water relief-valve Boilerlfumace enclosure <250.000 BTU N!R 250,000 BTU to 1,000,000 BTU's(I hour) eGi'ef �v/�,.Lc /Ld >1,000,000 BTU's(2 hour) J Gas furnace shut off within 30 IL or within line of site �- Oil furnace shut off at entrance to furnace area f Stockroom enclosure(I hour),3/4 hour door Storage/receiving/shipping room(2 hour),1 '/z doors I "•i hour doors and closers �4 hour corridor doors and closers Firewallslfre separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 I/s hour,3 hour Ceiling fire stopping 3,000/5,000 sq.R. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signagg Handicapped bathroom grab bars/sh"oilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond .active listening system and signage assembly space Final Electrical Site Plan/Variance required_ Final Survey,new structures .-is-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif:of Occupancy) Okay to issue C/C(Certif.of Compliance) Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit# AA INSPECTION ON: Name: SCILa&.)L �I�Zt%� -- AA I(A I AM PM ANYTIME Location: APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM -0 tj 5D(,t HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS feN 10 U.5 okJ CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGH IN CHIMNEY FINAL )A)5UJOU 104 wir-0,po-A aiao r FACTORY BUILT ROUGH IN (? . �j P, - head FINAL WOOD STOVE ROUGH IN &r" FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN OK THIS DATE OK FOR CO NOT OK FINAL FIREPLACE FACTORY BUILT ROUGH,IN FINAL COMDEV/CHPJSJ/tVORlj/LETTERS20011F IRE MARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection re ue c ve Queensbury Building&Code Enforcement Arrive: 'I In e �nm 742 Bay Road, Queensbury,NY 12804 Inspector's Initia NAME: PERMIT#: 0 a\ '7 �" LOCATION: Qd 6 �2-6 1 INSPECT ON: Z4 -:7 TYPE OF STRUCTURE: "o- Y N N/A • PVC:. R-1,R-2,R-3-P R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Df4in and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping 6 Copper Commercial OG6 Co��er,CPVC,Pex One &Two Family In�ation/Residential Check/Commercial Check ;40 Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly CONfMENTS: L:\SucHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing Insulation Inspection Report Office No.(518)761-8256 Date Inspection requeat received: Queensbury Building&Code Enforcement Arrive:.�V,2 at,! .t�Qprj 742 Bay Road,Queensbury,NY 12804 Inspector's 1nitLd NAME: PERMI T#: LOCATION: I k--,1-p Li::) INSPECT ON: TYPE OF STRUCTURE: x P)t)I% ID V 10(-r Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron, Copper Drain/Vent Comm. 0 Plumbing Vent/Vents in Place Ick Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft.above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check C)�L— Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\PamW\Whiting\Rough Plumbing Insulation Report.doc Framing/ Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re est re Pive Queensbury Building&Code Enforcement Arrive: a pin pa pm It 742 Bay Road, Queensbury,NY 12804 Inspector's Initials NAME: PERMIT#: LOCATION: t LU--�ku_13 R INSPECT ON- E :IPNCT#ON/ TYPE OF STRUCTURE: , Y N N/A COMMENTS COM Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more P"4—N Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 161)nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts.'6 ft.or less on center Ice and snow shield 24 inches from wall rc� Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Lc ts� C)QJ Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation, House side V2inch or 5/8 inch Type X V3 1 'Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above I below grade 5.0 sf grade maQ,-k- L-aoe-Lanc) Framing / Firestopping Inspection,Report CLA / a Ajco-(\ Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: /1L0' am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:-��... NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: L Q) Framing Y N N/A COMMENTS- Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 'a o,,,,r ire 12"O.C.Headroom 6 ft. 8 in. Mee S7eA, 5-/7,13 �— Stairwells 36 in. or more F--1e,(r1,- Headroom 6 ft. 8 in. AlfC— C111f—, Notches/Holes/Bearing Walls 0,1411b g, Metal Strapping for Notches Top Plate bVij re ul' ',-e J- 1 V2(w) 16 gauge(8) 16D nails each sideY-A f, ol Draft stopping 1,000 sq. ft. floor trusses rnork 01- Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LAS uel-lerningway\13 ui Iding.Codes.Inspection.FO RMSTraming Firestopping Inspection Report.doc January 28,2003 Rough Plumbing l Insulation Inspection Report p . 21-3 Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: t 1� am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: �G � PERMIT#: v�h LOCATION: c3C; U,3,\Km2 INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper,CPVC,Pex One&Two Family Jr Insulation/Residential Chec /Co ercia Check /�C--/p� Proper Vent,Attic Vent, ' Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly CONMENTS: •L:1SueHemingwaylBuilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: '-71 am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: 0, INSPECT ON: TYPE OF STRUCTURE: Y N PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron, Copper Drain/Vent Comm. Plumbing Vent Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Coer, CPVC Pex One&Two Family Residential Check/Commercial Check ation Proper Vent,Attic Vent 'flale o/ "ell Y_ Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: !L:\Sucliemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing/ Insulation Inspection Report Office No. (518)761-8256 Date Inspection request rece Queensbury Building&Code Enforcement Arrive: -a m -part 742 Bay Road,Queensbury,NY, 12804 Inspector's Initia n, NAME: Y mt,Qt'V PERMIT#; 'aw, LOCATION: INSPECT ON-_3�� TYPE OF STRUCTURE: N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron, Copper Drain/Vent Comm. Plumbing Vent Vents in Place Rough Plumbing/Nail Plates Read or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping ,zC er Commercial opper,CPVC,Pex One&Two Family /nsulation/Residential Check/Commercial Check -Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly LJ lug > COMMENTS: -L:1SucHemingwa3'Buildin,-.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: Q;7'1 am/pm Depart: am/pm /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: rx-V-,0 W klll,� PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURL Y N N/A Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,'2, 3 hour Fire wa 4 hour estopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Vi'inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMST-raming Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building"&Code Enforcement Arrive: 3x am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: LJ7, 3 3/4 Z, TYPE OF STRUCTURE: Y N N/A S Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate /j I Y2(w) 16 gauge(8) 16D nails each side (Cki Draft stopping 1,000 sq. ft..floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Ireel,111— Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Ole" A/r/4 Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X c1d Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHem.ingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection req s ree v(� Queensbury Building&Code Enforcement Arrive: a p 742 Bay Road, Queensbury,NY 12804 Inspector's Initia NAME: A( rl ERMIT LOCATION: SPECT ON: 3-1 E) TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain t Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents .5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial opper,CPVC,Pex One&Two Family su atioxi/Re M tial Checl�/eQornmerct(kck Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct.Work Sealed Properly COMMENTS: L.\Suellemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 4 10-5L�� 'F Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Notes: Queensbury, NY 12804 ARRIVA-9-- a TVJ5�anyipm In P (518) 761-8256 Inspector's 71nitial PERMIT NAME: PERMIT# 7--op-Z- LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing_ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents1n—Place WjQRough Plumbing F Heating Rough-In 7-- Insulation x, Foundation Walls Inferior R- Foundation Walls Exterior R- Floors GC))t, vA9EAR- Ct Walls R- 4A. Ceiling R- Duct work or piping in C)tA unheated spaces R- Proper Vent,Attic Vent f7AN Framing —TP Jack Studs/Headers Bracing/Bridgmig— Joist Hangers Jack Posts/Main BeamL_ Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping j= L:\SueHemingway\Building.Codes.Inspection.FORNIS\GENERAI,INSPECTION REPORT.doc Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection req r ei d: e a Queensbury Building&Code Enforcement Arrive: -a p part. 742 Bay Road, Queensbury,NY 12804 Inspector's Initia NAME: PERMIT#: 755 LOCATION: -)1 INSPECT ON: TYPE OF STRTCTU-RE-: Y N N/A COMMEN Framing OM/MEN Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3, 4 hour stopping 143� Penetration sealed 16 inch insulation in cavity min. V/ Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LAS u cFlcmin gway\Bui Iding.Codes.Inspection.FO RMSTrarning Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection r q e ece. ): Queensbury Building&Code Enforcement Arrive:-a I p rt: !A-"Zd ar��� 742 Bay Road, Queensbury, NY 12804 Inspector's Initi NAME: PE IT#: 7, S LOCATION: l rrt3 IN ECT ON: TYPE OF STRUCTURE: Y N. N/A Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers COMMENTS Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more .Headroom 6 ft. 8 in. ,Notches/Holes./Bearing Walls Metal'Strapping for Notches Top Plate I V2 (w) 16 gauge(8) 16D nails each side Draft stopping-1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Sucliemingway\Buildin-..Codes,Inspection.FORMSTrarning Firestopping Inspection Report.doc January 28,2003 Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road /Notes: Queensbury, NY 12804 ARRIVR a a"OPM (518) 761-8256 Inspector'sInitia NAME: PERMIT# LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing C� for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing_ Backfill Approval c P PA u h1l ing Under Slab u u rnbing Vent/Vents in Place ou2 ough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Stads/Headers Bracing/Bridging_ Joist Hangers Jabk Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour inetration Sealed e Wall 2,3,4 hour_ restoppin e 1P L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc Rough Plumbing /Insulation Inspection Report Office No, (518)761-8256 Date Inspection re r eiv Queensbury Building&Code Enforcement Arrive: pm a 742 Bay Road,Queensbury,NY 12804 Inspect NAME: PERMIT LOCATION: 1, INSPECT ON: TYPE OF STRUCTURE: Inspection re re epi pm ti N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft.above highest Connection for 15 minutes Water Supply Piping Copper Commercial per, CPVC,Pex One &Two Family sulation/Residential Check/Co�nmeTVI Check .Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: -L:\Sueliemingway\Building.Codes.Inspection.FORN4S\Rough Plumbing Insulation Report.doe January 28,2003 Rough Plumbing/ Insulation Inspection Report Office No. (518) 761-8256 Date Insp ction request received: Queensbury Building&Code Enforcement Arrive: I -k)&am/pm epart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: S r` PERMIT#: LOCATION: n INSPECT ON: IQ TYPE OF STRUCTURE: Y N N/A ( � PVC: R-1,R-2,R-3,R-4 Drain/Vents I Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential C eck//Comme cial Check 04, ,Y1eeA-vck ejolrlu. Proper Vent,Attic Vent p j Duct/Hot Water Piping Insulation If required unheated spaces lVeecF �Z+ Combustion Air Supply for furnace Duct Work Sealed Properly COMMENTS: L:\PamW\Whiting\Rough Plumbing Insulation Report.doc Rough Plumbing 1 Insulation Inspection Report- Office No. (518)761-8256 Date inspection request ived.` Queensbury Building&Code Enforcement Arrive: a pof epa 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: N)el-le C' , -\",IS PERMIT#:' C --7 LOCATION: INSPECT ON: 3- -S-0 . 2,6 TYPE OF S71RUCTURE. L-1 Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place )�ogh Plumbt! ail Plates �. Head or Air Supply Test Drain and Vents %,--s 4 5 PSI or 10 ft. above highest Connection for 15 minutes Water Su Water ;erC2onune;rcc Commercial I V11" x r, ex��ea Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\Pamw\whiting\Rough Plumbing Insulation Report.doe FramiiFl Fire\st port Office No. (518) 761-8256 Date Inspection request,r ed: Queensbury Building&Code Enforcement Arrive: a part* a m 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: QA/V,,�PERMIT#: L LOCATION: —INSPECT ON: TYPE OF STRUCTURE: Y N /N/A COMMENTS \/Framing CA , V/ Jack Studs Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 1231 O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2(w) 16 gauge(8) 16D nails each side Draft stopping 17,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 'inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour "restopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 26 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestoppin.-Inspection Report.doc January 28,2003 SPRINKLER SYSTEM CHECKLIST Date:. Name: f>0.4ba,,WL rA4q�co Location: NIA YES NO Sprinkler system plan and facility layout provided FDC correct;size FDC accesible Tamper switches in place Flow switch in place- All sprinkler heads have proper clearance FDC riser piping correct size Letter on file from contractor per NFPA 13 Inspector , f f Framing Firestopping Inspection Report Office No. (518) 761-8256 Date'Inspection re eF rec ive d: 3 � Queensbury Building&Code Enforcement Arrive: pin 742 Bay Road, Queensbury,NY 12804 Inspector's s: NAME: Ile PERMIT#-. LOCATION: ciw* INSPECT ON: -a�-2 AL TYPE OF STRUCTURE: JCTURE: Framin Y N /N/A COMMENTS g' Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I Y2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueFfemingway\Buildin-,.Codes.Inspection.FORMSTrarning Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re ecei Queensbury Building&Code Enforcement Arrive: pm. ep : 12,:-tc> aqZW 742 Bay Road,Queensbury,NY 12804 Inspector's Initial . ,on reque rp Initial NAME: t,3C H F—P—m r:=—2 I-A 0 PERMIT#: Z=CnZ�-- LOCATION: 7—,;-s 1 1 INSPECT ON: 2——7 1 TYPE OF STRUCTURE: it Y N N/A COMMENTS Framing Jack Studs/Headers D V—\ Bracing/Bridging � � '`J1 Joist hangers �— 1;R)�C:N- Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in.- Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 Y2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above I below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re re i e Queensbury Building&Code Enforcement Arrive:X 4-Co a D art: 742 Bay Road, Queensbury,NY 12804 Inspector's Inift NAME: t C PERMIT#: 7-crl)-L-755- LOCATION: 7 5 � INSPECT ON: Z/-L1%:t0 TYPE OF STRUCTURE: O-PFC-V- �1 - , Y N N/A COAMENTS Framing Jack Studs/Headers V4R\)C-- i3T-=E!13 Bracing/Bridging C-OT 13ROV)F-0 � DrouLra-D. Ru- Joist hangers Jack Posts/Main Beams V/ 9-�OARIZOZ� Exterior sheeting nailed properly IN A- -TIVO-AXA-) 12"O.C. Vp �� DbCZMV-�-N-EV 00 Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls 7(-V- Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall 60R� Fire separation 1,2,3 hour Fire wall 2, 3,4 hour esv—=Pzl izc, Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation - House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection requq re.ce' e m P Queensbury Building&Code Enforcement Arrive: a art: IN a rr T11P / ) 742 Bay Road,Queensbury,NY 12804 Inspector's Initi NAME: t--\v�-R PERMIT#: ZDEZ� LOCATION: Z&5 Lo I U--,-r ODV' INSPECT ON: _2-- 1?3 TYPE OF STRUCTURE: Framing Y N N/A COMMENTS 29 ETA i�Ll 11 \?- Jack Studs ,�3-T Headers F-EL- L*W- Bracing Bridging F--P,t, Joist hangers U3 �-:t Jack Posts!Main Beams Exterior sheeting nailed properly c 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side "Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above below grade 5.0 sf grade 12VE:-- �t Office use .GENERAL INSPEC ION REPORT Inspector: Ready at time of Queensbury Dept. of Community Development Request received: 441a� Meet: Building& Code Enforcement At time: 742 Bay Road Queensbut3,, NY 12804 ARR[VE9,q5 pr In Notes: a l a� (518) 761-8256 Inspector's Initials NAME: PERMIT# c C --7 LOCATION; 1/ot-4wb- INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS i is our orn Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site 'Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing_ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing HeatingRough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in . unheated spaces R- Proper Vent,Attic Vent Framing__. Jack Studs[Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L-,\SueHemiiigway'auildiiig.Codes.Iiispection.FORMSiGENERAL NSPECTION REPORT-doe Office Use .GENERAL INSPECTION REPORT (33Inspector: Town of Queensbury Ready at time:'_-.: Dept. o Community Development Request received: 1 Vl�Z �� P .f tJ' p �` _ Meet: Building& Cade Enforcement . At time: 742 Bay Road Queensbury, AT 12804 ARRII�E am/pyn: DEPART(, �1 am/pm Notes- 1 (518) 761-8256 Inspector's Initials �r NAME: �Akj ' d-,w�gmrr# 2—o ozf LOCATION: hhl 0 -�� ?Q INSPECT ON(date): J 7 7� (� �M i t" he— TYPE OF STRUCTURE: RECHECK N/A YE O COMMENTS odtizl slPiers Mant�lithic Four F Reinforceinen m Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour� Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing H ating Rough-In dksu oundation—WA11921nterior R- Foundation Walls.Exterior R- ` Floors R- Walls it- Ceiling R- Duct work or piping in unheated spaces R- _ Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe Offke.Use GENERAL INSPECTION REPORT Inspector: at time.. Town of Queensbury " ` Ready . Dept. of Community Development ,Request received: t& Meet: ,Building& Code Enforcement At time: 742.Bay Road � cr � Queensbwy}AY 12804 ARRIVE am/pm: DBFART�am/pm Notes:" (518) 761-8256 Inspector's Initials NAME: lgi' PERMIT-# LOCATION: 7J�j ,I Lov f6o I — INSPECT ON(date): TYPE OF STRUCTURE: ? `- CHECK N/A YE NO COMMENTS ' �nohthic Form Reinforcement in Place `-1 The contractor is responsible for providing protection from freezing for 48 flours following the-placement of the concrete. Materials for this purpose on site "FoundationlWallpour' Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing VentlVents in Place Ro Plumbing . ating Rough s Fian - Foundation Walls Interior R- Foundation Walls Exterior R- Floors R Walls R- f Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent. Framing Jack Studs/Headers BracingBridging Joist Hangers. Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4"hour Firestopping L.1SueHemingwa)'Ouiiding.Codes.Inspection.FORMSIGENERAL INSPECTION REPORT.doe Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: .Building& Code Enforcement At time: 742 Bay.Road Queensbury, IVY 12804 ARRIVE-am/pm: DEPART 64, 5am/pm Notes: (518) 761-8256 Inspector's Initials . NAME: e54!G,2 we gD2-41 PERMIT# LOCATION: 710 G�t/Lt�r)lJ,�172 INSPECT ON(date): TYPE OF STRUCTURE: 'RECHECK N/A YES NO COMMENTS /Footings/Piers � � Monolithic Pour Form . /1/0-7— Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place FoundationIDampproofing Backfill Approval Plumbing Under Slab_ Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- . Floors R Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging • Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping Z:1SueHemingway\Building.Codes.Inspection.FORMSiGENERAL INSPECTION REPORTAOC = ' -16-02 WED 2:52 PM SCHERMERHORN FAX IdO. 5187439653 �� _ P.. 2 evergreen OCT TESTING&ENVIRONMENTAL SERVICES, INC. TOWN OF QUEENSbURY ❑ 594 Broadway Watervliet, New York 12189, Phone:518-266WtD1 38 © PO Box 482 Orchard Park,New York 14127- Phone:716• - 74 Fax:716-648-3521 FIEND IN-PLACE - DENSITY TEST REPORT PROJECT: Medical Center REPORT NO: 02-167-1001 CLIENT: Schermerhorn Construction DATE: 10-1-02 CONTRACTOR: 5chermerhorn Construction :100 NO: ETE-02-167 Test Depth in-Place in-Place % °A proctor Location and Remarks No. or Density Moisture Compaction Req`d Code Elevation (pc6 �/a) 1 FG 115.E 3.2 100 95 .772 8'W, 10' N of SE Corner 2 FG 114.8 3.8 100+ 95 772 25'W, 15' N of SE Corner 3 FG 112,9 3.3 98.5 95 772 10' E,10' N of SW Corner 4 FG 114.E 3.9, 100.0 95 772 10'E, 60'N of SW Corner 5 FG 115.2 2.8 100+' 95 772 1 15'W, 65' N of SE Corner 6 FG 112.1 3.71 97.9 95 772 40'E, 60'a of NW Corner 7 FG 1.12.7 3.9 98-3 95 772 15'E, 35' S of NW Corner 8 FG 114.3 3.4 99.7 95 772 5'E, 5' S of NW Corner 9 FG 114.4 3.7 99.8 95 772 8'W, 8'S of NE Corner 10 FG 114.3 3.8 99.8 95 772 12'W, 25'S of NE Corner Proctor Maximum Optimum Material Type and Source Code Density Moisture(%) C 772 1 114.6 12.1 1 SAND, Some Gravel, trace silt Remarks: Respectfully submitted, Technician: S. Vacula evewsteen TESTING&ENVIRONMENTAL SERVICES,INC. Office Use .......... GENERAL INSPECTI REPORT nspector: Town of Queensbuq Ready at time: 21,1 1, Dept. of Community Development Request received: 12jV110 Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVEbc�p RT7!,F0 am/pm Notes: [nsp Ready Meet: time: P (518) 761-8256 Inspector's Ini i A NAME: PERMIT TT, S— # LOCATION: b C6 6,66 INSPECT ON(date): TYPE OF STRUCTURE: wu , C+jr RECHECK N/A YFA NO COMMENTS Footings/Piers Monolithic Pour Form Y1 Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place FoundationfDampproofing__ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place—— ; Plumb eating ng Rough-In V Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/BridgingJoist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firest opping— L:\,Suel4emingway\Building.Codes.Inspection.FORMS\GENERAT,INSPECTION REPORT.doc Office Use (q) �e'� , GENERAL INSPECTiON REPORT Inspector: Town of Queensbury Ready at time Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE, am/ i): DE AR R T1_v� (518) 76�14- 256 Inspector's NAME: PERMIT# 5?X 12? LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: Z'e RECHECK N/A YE Sr NO COMMENTS 0 ieis o it is Pour Formni orcement in Place 7T The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dan-ipproofing__ Backfill Approval Plumbing Under Slab Vlumbing Vent/Vents in Place ,kough Plumbing-- Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig- Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppmg_ L:\SueHemingway\Building.Codes.Inspection.FORPvIS\GENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: .Dept. of Community Development Request received. �� ��-- Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE am/ Aa pyn Notes: (518) 761-8256 Inspector's Initi Is i NAME: - PERMIT# 2 7�6 LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/W allpour Reinforcement in Place Foundation/D amppro o fing Backfill Approval qumbmg Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior-R- Floors R Walls R- Ceiling R- j Duct work or piping in unheated spaces R- Proper-Vent,Attic Vent Framing / Jack Studs/Headers Bracing/Bridging Joist Hangers Jack-Posts/Main Beam / Air Infiltration Barrier $ Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:1SueHerningway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe Office Use GENERAL IN SPELT IOT� OiY Inspector: Town of Queensbury - (j Z— Ready at time: Dept. of Community Development Request received: —aLj�� Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE ART a m Notes: (518) 761-8256 Inspector's Initia PERMIT NAME: # "92--7 5-; LOCATION: INSPECT ON(date): 62— TYPE OF STRUCTURE:_VK-E-j ('j1—, RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place FoundationfDampproofing_ ),,r,Backfill Approval '7v Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation---- Foundation Walls Interior R- Foundation Walls Exterior R Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour 'v Penetration Sealed P Fire Wall.2,3,4 hour irestoppmg_ e\gway\Building.Codes.Inspection.FORbiS\GENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPO Inspector: i I t p - Town of Queensbury 00 Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVEI X wpm Notes: elP R (518) 761-8256 Inspector's Initi Is NAME: PERMIT LOCATION: C;6 INSPECT ON(date): TYPE OF STRUCTURE: E' 3 AllRECHECK N/A YES NO COMMENTS 10.4 Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. ---MaterialL&--P-urpose on site <T:ou:�n—datio >.c> Reinforcement in Place tAIAI t > Foundation/Danipproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging_ Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firesto ' pping— L:\SueHemingway\]3uilding.Codes.Inspection.FORMS\GENERAL INSPECTION REPORTAOC fir (Yfflce Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbuol, ArY 12804 ARRIVE T 4 Notes: (518) 761-8256 Inspector's Initia NAME: C/L'P PERMIT# _V14LO iF -- LOCATION: 7,9- "101. INSPECT ON(date): TYPE OF STRUCTURE: K4- RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/DanipprooPing j�.t8ackfill Approval4 Plumbing Under Slab Plumbing Vent/Vents in Place Yeough Plumbing_ 10 eating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig- Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping-- L:\SueHemingway\Building.Codes.Inspcction.FORMS\GENERAT,INSPECTION REPORT.doe i ZREPORT GENERAL ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Rbad Quecusbury,NY 12804 Arrive am/ Depart ector's Init' s NAME: PERMIT X;k- LOCATION:� ,�� fi t- DATE: 9-1 TYPE OF STRUCTURE: ! Imo`aF1 t-- RECHECK N/A YES NO COMMENTS Footings/Piers -� Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing � �� for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Cteiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing �. Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppin Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE am/pm:, DEPART-7).1-r'am1pm Note (518) 761-8256 Inspector'slnitia4-11\ NAME: Gvil ti PERMIT# LLOCATION: 76C INSPECT ON(date): 1 o-a TYPE OF STRUCTURE: RECHECK N/A i YES O COMMENTS Orou rig onolithic Pour Form 71 Reinforcement in Place 2-4�/ The contractor is responsible for providing protection from freezing fo 48 hours following the placement the concrete. aterial for this purpose on site un, 0 allpour Reinforcement in Place I — Foundation/Dainpproofmi-----L— Backfill Approval Plumbing Under Slab Plumbing Vent(Vents in Place Rough Plumbing__ Heating Rough-In Insulation Foundation Walls Interior R- Foundation'Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping_ L-.\SueHemingway\Building.Codes.Inspection.FORrvlS\GENERAT,INSPECTION REPORT.doe Office Use GENERAL INSPECTION REP 0"A' T Inspector: Town of Queensbury Ready at time: 0 Dept. of Community Development Request received: � /� Gam-" Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE a D RT�a p Notes: (518) 761=8256 Inspector's Initi NAME: �C fA A 'S(—e- Alf PERMIT# LOCATION: ( t1, a /lscoc—f - INSPECT ON(date): TYPE OF STRUCTURE: f RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour.Form Reinforcement in Place _ The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site ��.Foundation/Wallpaur V3�1�--T DA ,Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R Walls R- Ceiling R- f Duct work or piping in / unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers /r BracingBridging / Joist Hangers 7 Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingwaylBuilding.Codes.Inspection.FORMSIGENERAL INSPECTION REPORT.doc i Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE am/pm: DEPARTjj-_1am/pm Notes: (518) 761-8256 Inspector's Initials NAME: PERMIT# 2- LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: CHECK N/A..YE 1 NO CON EVIEN Footings/Piers f� Monolithic Pour Form Reinforcement in Place '3 At!q The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing_ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig- Joist Hangers Jack Posts/Main Beair�_ Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping- L-\SueHemiiigway\Btiilding.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe a Q '1 0 (D0 0 Q'0 .,,a -+ ly� :ai � .ri(D (D (D 0 ' ZM Mj aaaHo r�, M 100 s . , -i I @0 C(� totoo (+ ii0 m~h0 mi11v"0In .r 0 ~ � cn U) 0 0 .J, ~h 0, '1 ;00 000 \ X0 N au h o(A o r �) 0 @ :3 a � � � cn �, _� iD � rF .<r) -h:3 IV (D 01� I ii awl rt r} TO 0 0 :3 ol n@ a ll-q 7 "u � L4 M . -� 0 0 (Al 0> 40. 4400 :r f"I I .,o 0 (A 0 , o. Aw 0 (D H 0 m N m f �\ � @fD@ ri 1 Z0@@ J. (D 0 C+ (+ rl Du Office Use GENERAL MSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: 6 Meet: Building& Code Enforcement At t' e: 742 Bay Road Queensbury, NY 12804 ARRITE a a tes:: (518) 761-8256 Inspector's Initia J�I�tk.(Z+( S& 77NAME: Ctr I&IA 7j kp4Z, PERMIT# 2()L12—/P LOCATION: JAJ� 1J.6 Wj INSPECT ON(date7 Iola, TYPE OF STRUCTURE: / RECHECK N/A iYES A/0 COM TS *Fo: tings/Piers . onolithic Pour Form Fei einforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following),the placement of the concrete. Materials for this purpose on site FoundationfWallpour Reinforcement in Place Foundation/Dampproofing__ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation ,), 6 Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- 'TO Duct work or piping in unheated spaces R- Proper Vent,Attic Vent \Z SF-,w3 Framing Jack Studs/Headers Bracing/Bridging Joist Hangers- Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping- L:\SueHemiiigway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 518-761-8201 June 9,2003 Rich Schermerhorn Schermerhom Construction,Inc. 15F Birdie Drive Queensbury,NY 12804 Dear Rich: The following items are still open on the Medical Arts building at 25 Willowbrook Road and need to be addressed immediately so that this Department can issue a Temporary CO until site work is complete. 1. The electrical rooms, mechanical rooms, sprinkler risers, and fire alarm panels must be labeled with signage on doorways leading to these spaces. This has not been completed as of Friday,June 6th.- An elevator door key, as well as the elevator fire department keys need to be put in the sprinkler room or electrical room and labeled as such. 2. New York-Fire and Signal still has to finish the fire alarm system with regards to the dialer,so that - the fire alarm--system and sprinkler-system will be-monitored -off-site 24-hours a--day.—-This installation still remains incomplete. 3. .-The pooLarea-needs to be finished,.indudingtile-and electrical w. ork,-and:the hatch-entering the, basement space around the bottom of the pool must be complete. 4. We need a letter from you,if you wish to have us issue a permanent CO,stating that the site work will be completed by a date of your choosing within 90 days from today. If you are not looking for a permanent CO,and this Department has to issue a temporary CO with the condition that all site work be complete within 90 days,then you must submit a check for$110, $100 of which will be a deposit,and fill out the Temporary Certificate of Occupancy paperwork. I would ask that all these issues be addressed immediately. Sincerely, OF QUE RYA David Hatin, ctor Building and Code Enforcement DH/mg cc: Steve Smith,Fire Marshal Craig Brown,Zoning Administrator Chris Round,Executive Director "HOME OF NATURAL BEAUTY .'. . A GOOD PLACE TO LIVE" SETTLED 1763 40 Envelope Compliance Report Proposed New York State Energy Conservation Construction Code COMeheck-EZ Software Version 2.3 Release I Data filename:C:\Program Files\Check\COMcheck-EZ\MED.cck Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees F): 380 Building Use Method of Compliance: Whole Building Method Building Type Floor Area Medical and Clinical Care 34000 Project Description(check one): Y--New Construction —Addition —Alteration —Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Air Leakage,Component Certification,and Vapor Retarder Requirements Inspection Approved Initial Date (Y/N) All joints and penetrations are caulked,gasketed, weather-stripped,or otherwise sealed Fireplaces installed with tight fitting non-combustible fireplace doors Dampers integral to the building envelope are equipped with motorized dampers Cargo doors and loading dock doors are weather sealed Recessed lighting fixtures are sealed or gasketed Windows,doors,and skylights certified as meeting leakage requirements Component R-values&U-factors labeled as certified Vapor retarder installed Climate-Specific Requirements Gross Cavity Cont. Proposed Budget Component Name/Description Area R-Value R-Value U-Factor U-Factor Roof 1:All-Wood Joist/Rafter/Truss 17000 30.0 0.0 0.035 0.051 Exterior Wall 1:Wood Frame,Any Spacing 11680 19.0 0.0 0.068 0.074 Window 1:Vinyl Frame,Double Pane,Tinted,shgc 0.32 1400 --- --- 0.333 0.520 Door 1:Glass,Tinted,shgc 0.27 135 --- --- 0.330 0.520 Floor 1:Heated Slab-On-Grade,Vertical 4 ft. 584 --- 10.0 --- --- (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Envelope PASSES: Design 30%better than code Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the Proposed New York State Energy Conservation Construction Code requirements in COMcheck--EZ Version 2.3 Release 1. r Principal velope Designer-Name Signatur Da• Lighting and Power Systems Compliance Certificate Proposed New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.3 Release 1 Data filename:C:\Program Files\Check\COMcheck-EZ\MED.eck Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees 17): 380 Building Use Method of Compliance: Whole Building Method Building Type Floor Area Medical and Clinical Care 34000 Project Description(check one): New Construction —Addition —Alteration —Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Inspection Approved Initial Date (Y/N) Controls,Switching,and Wiring Independent controls for each space(switch/occupancy sensor) Exceptions: Security lighting,building lobby/retail store/mall Master switch at entry to hotel/motel guest room Individual dwelling units separately metered Two switches,dimmer,or occupancy sensor in each space providing a uniform illumination pattern Exceptions: Only one luminaire in space; An occupant-sensing device controls the area; The area is a corridor,storage,restroom,or lobby Automatic lighting shutoff control in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.ft Photocell/astronomical time switch on exterior lights Exceptions: Large covered areas requiring lighting during daylight hours Tandem wired one-lamp and three-lamp ballasted luminaires Exceptions: Electronic high-frequency ballasted luminaires not on same switch Transformers meet minimum efficiencies listed in Table 805.6.1 or 805.6.2 Interior Lighting Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 54400 30040 YES Exterior Lighting Type(s)of exterior lighting sources: Fluorescent —Metal Halide High-Pr. Sodium Exceptions: Specialized signal,directional,and marker lighting;lighting highlighting exterior features of historic buildings; advertising signage;safety or security lighting;low-voltage landscape lighting. Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the Proposed New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.3 Release 1. golf!% q410 Z. rmcipal fighting Designer-Name Signa� Date Lighting Application Worksheet Proposed New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.3 Release 1 Section 1: Allowed Lighting Power Calculation A B C D Total Floor Allowed Allowed C Area Watts Watts Building Type (ft2) (watts/ft2) 03 x C) Medical and Clinical Care 34000 1.6 54400 Total Allowed Watts= 54400 Section 2: Actual Lighting Power Calculation A B C D E F Fixture Fixture Description Lamps/ #of Fixture ID Lamp Description/Wattage Per Lamp/Ballast Fixture Fixtures Watt. (D x E) 1 Treatment rooms/48"T8 32W/Electronic 3 275 96 26400 2 Exterior lights High-Pressure Sodium 70W/Electronic 1 12 70 840 3 Corridor lights Twin Tube 40W/Electronic 2 35 80 2800 Total Actual Watts= 30040 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies. Total Allowed Wafts= 54400 Total Actual Watts= 30040 Project Compliance= 24360 Lighting PASSES: Design 45%better than code Mechanical Compliance Report Proposed New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.3 Release I Data filename:CAPrograra Files\Check\COMcheck-EZ\NffiD.cck Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees F): 380 Building Use Method of Compliance: Whole Building Method Project Description(check one): —New Construction —Addition —Alteration —Unconditioned Shell(File Affidavit) Section 3: Mechanical Systems List Quanti System Type&Description I HVAC System 1: Heating:Duct Furnace,Gas/Cooling: Split System,Capacity>=90-<135 kBtu/h, Air-Cooled Condenser/Multiple-Zone Section 4: Requirements Checklist Generic Requirements: Must be met by all systems to which the requirement is applicable 1. Load calculations per 1997 ASHRAE Fundamentals 2. Plant equipment and system capacity no greater than needed to meet loads -Exception:Standby equipment automatically off when primary system is operating -Exception:Multiple units controlled to sequence operation as a function of load 3. Minimum one temperature control device per system 4. Minimum one humidity control device per installed humidification/dehumidification system 5. Thermostatic controls must have 5 deg.F deadband I -Exception:Thermostats requiring manual changeover between heating and cooling 6. Automatic Controls: Setback to 55 deg.F(heat)and 85 deg.F(cool);7-day clock,2-hour occupant override, 1 0-hour backup Exception:Continuously operating zones Exception:2 kW demand or less,submit calculations 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow>3,000 cfin 8. Outside-air source for ventilation;system capable of reducing OSA to required minimum 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly -Exception:Ducts located within equipment -Exception:Ducts with interior and exterior temperature difference not exceeding 15 deg.F. 10. Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts;UL 18 1 A or 18 1 B tapes and mastics 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment 12. Hot water pipe insulation: I in.for pipes<--1.5 in. and 2 in.for pipes>1.5 in. Chilled water/refrigerant/brine pipe insulation: 1 in.for pipes<=1.5 in.and 1.5 in.for pipes>1.5 in. Steam pipe insulation: 1.5 in.for pipes<--1.5 in.and 3 in.for pipes >1.5 in. -Exception:Piping within HVAC equipment -Exception:Fluid temperatures between 55 and 105 deg.F -Exception:Fluid not heated or cooled -Exception:Runouts<4 ft in length 13. Operation and maintenance manual provided to building owner 14. Balancing devices provided in accordance with 603.15 of Mechanical Code for New York State Requirements Specific To:HVAC System I 1. Equipment minimum efficiency: Duct Furnace(Gas): 80%Ec 2. Minimum one temperature control device per zone 3. Newly purchased cooling equipment will meet the cooling efficiency requirements 4. Discharge dampers prohibited with fan motors>25 hp 5. Integrated air economizer required 6. Systems serving more than one zone must be VAV systems 7. Single-duct VAV terminals must reduce primary air before reheating 8. Controls capable of resetting supply air temp(SAT)by 25%of SAT-room temp difference 9. Fan motor demand<=50%design kW at 50%design flow-calculations required Section 5: Requirements Description The following section provides a more detailed explanation of the requirements listed in Section 4. Generic Requirements: Must be met by all systems to which the requirement is applicable 1. Design heating and cooling loads for the building must be determined using procedures equivalent to those in Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible,within available equipment options. -Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes.Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. -Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degree F deadband(a range of temperature where no heating or cooling is provided). -Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degree F during heating and setting up to 85 degree F during coolingb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power. -Exception:A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously. -Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h)or less. 7. Outdoor-air supply systems with design airflow rates>3,000 cfm of outdoor air and all exhaust systems must ,have dampers that are automatically closed while the equipment is not operating. 8. The system must supply outside ventilation air as required by Chapter 4 of the Mechanical Code for New York State.If the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels, the system must be capable of reducing outdoor-air flow to the minimum required levels. 9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces(spaces neither heated nor cooled)must be insulated with a minimum of R-5. Unconditioned spaces include attics,crawl spaces,unheated basements,and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When ducts are located within exterior components(e.g.,floors or roofs),minimum R-8 insulation is required only between the duct and the building exterior. -Exception: Duct insulation is not required on ducts located within equipment. -Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degree F. 10. All joints,longitudinal and transverse seams,and connections in ductwork must be securely sealed using weldments;mechanical fasteners with seals,gaskets,or mastics;mesh and mastic sealing systems;or tapes. Tapes and mastics must be listed and labeled in accordance with UL 18 IA or UL 18 1B. 11. Mechanical fasteners and seals,mastics,or gaskets must be used when connecting ducts to fans and other air distribution equipment,including multiple-zone terminal units. 12. All pipes serving space-conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in.for pipes<=I 1/2-in.nominal diameter 2 in. for pipes>I 1/2-in.nominal diameter. Chilled water,refrigerant,and brine piping systems: 1 in.insulation for pipes<=I 1/2-in.nominal diameter 1 1/2 in.insulation for pipes>1 1/2-in.nominal diameter. Steam piping: 1 1/2 in.insulation for pipes<--1 1/2-in.nominal diameter 3 in.insulation for pipes>1 1/2-in.nominal diameter. -Exception: Pipe insulation is not required for factory-installed piping within.HVAC equipment. -Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55 degrees F and 105 degrees F. -Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. -Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control valve and HVAC coil. 13. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity(input and output)and required maintenance actionsb) equipment operation and maintenance manualse) HVAC system control maintenance and calibration information,including.wiring diagrams,schematics,and control sequence descriptions;desired or field-determined set points must be permanently recorded on control drawings,at control devices,or,for digital control systems,in programming commentsd) complete narrative of how each system is intended to operate. 14. Each supply air outlet or diffuser and each zone terminal device(such as VAV or mixing box)must have its own balancing device.Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices,and supply air diffusers. Requirements Specific To:RVAC System I 1. The specified heating and/or cooling equipment is covered by the New York State Energy Conservation Code and must meet the following minimum efficiency: Duct Furnace(Gas): 80%Ec 2. Each zone of a multiple-zone system must have its own temperature control device. 3. The specified cooling equipment is covered by Federal minimum efficiency requirements.New equipment of this type can be assumed to meet or exceed New York State Energy Conservation Code requirements for equipment efficiency. 4. Fans with motors>25 hp may not be equipped with discharge dampers. 5. An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate. An integrated economizer allows simultaneous operation of outdoor-air and mechanical cooling. 6. Systems serving multiple thermostatic control zones must be'variable-flow systems. Zone terminal controls must reduce the flow of primary supply air before reheating,retooling,or mixing air streams. 7. The specified multiple-zone system is equipped with single-duct VAV terminals.These terminals must be equipped with dampers,air valves,or other means to reduce the supply of primary supply air to a minimum prior to reheating. 8. Multiple-zone systems must include controls capable of resetting the supply air temperature by at least 25%of the difference between the design supply air temperature and the design room temperature. 9. Fans over 25 hp on a variable-flow system are specified to include flow controls that limit fan power consumption to 50%of the design power consumption at 50%of the design airflow rate.Manufacturer's literature and other supporting documentation must be submitted with permit application. Section 6: Compliance Statement The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the Proposed New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.3 Release 1. The design professional shall provide to the code enforcement official a written certification that the required HVAC tests,system balancing,etc.,have been performed and the system is operating as designed. The design professional shall retain copies of the test reports to be provided to the code enforcement official,if requested. Z. Principal Me6hanical Designer-Name SignatuX Datf f V� Enveitpe Compliance Report Proposed New York State Energy Conservation Construction Code AUG 2 9 2002 COMcheck-EZ Software Version 2.3 Release 1 Data filename:CAProgram.Files\Check\COMcheck-EZ\MED.cck 7 0 IJ V N OF G1(.1 E-EILD, B!)1 F.Y Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees F): 380 Building Use Method of Compliance: Whole Building Method Building Type Floor Area Medical and Clinical Care 34000 Project Description(check one): —New Construction —Addition —Alteration Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Air Leakage,Component Certification,and Vapor Retarder Requirements Inspection Approved Initial Date (Y/N) All joints and penetrations are caulked,gasketed, weather-stripped,or otherwise sealed Fireplaces installed with tight fitting non-combustible fireplace doors Dampers integral to the building envelope are equipped with motorized dampers Cargo doors and loading dock doors are weather sealed Recessed lighting fixtures are sealed or gasketed Windows,doors,and skylights certified as meeting leakage requirements Component R-values&U-factors labeled as certified Vapor retarder installed +'Climate-Specific Requirements Gross Cavity Cont. Proposed Budget Component Name/Description Area R-Value R-Value U-Factor U-Factor Roof 1:All-Wood Joist/Rafter/Truss 17000 30.0 0.0 0.035 0.051 Exterior Wall 1:Wood Frame,Any Spacing 11680 19.0 0.0 0.068 0.074 Window 1:Vinyl Frame;Double Pane,Tinted,shgc 0.32 1400 --- --- 0.333 0.520 Door 1: Solid 135 --- --- 0.071 0.120 Floor 1:Unheated Slab-On-Grade,Vertical 4 ft. '584 --- 10.0 --- --- (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Envelope PASSES: Design 31%better than code Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the Proposed New York State Energy Conservation Construction Co uirements in COMcheck-EZ Version 2.3 Release 1. r 6/?,9/0 Principal Envelope Designer-Namd Signature Date OF NEiv KEITh1a LJ r 0a 066752 '0fi�SSIOk�� Envelope Compliance Report Proposed New York State Energy Conservation Construction Code COMeheck-EZ Software Version 2.3 Release I Data filename:C:\Program Files\Check\COMcheck-EZ\MED.cck Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees F): 380 Building Use Method of Compliance: Whole Building Method Building Type Floor Area Medical and Clinical Care 34000 Project Description(check one): New Construction —Addition —Alteration Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Air Leakage,Component Certification,and Vapor Retarder Requirements Inspection Approved Initial Date (Y/N) All joints and penetrations are caulked,gasketed, weather-stripped,or otherwise sealed Fireplaces installed with fight fitting non-combustible fireplace doors Dampers integral to the building envelope are equipped with motorized dampers Cargo doors and loading dock doors are weather sealed Recessed lighting fixtures are sealed or gasketed Windows,doors,and skylights certified As meeting leakage requirements Component R-values&U-factors labeled as certified Vapor retarder installed %Ck Climate-Specific Requirements Gross Cavity Cont. Proposed Budget Component Name/Description Area R-Value R-Value U-Factor U-Factor Roof 1:AM Wood Joist/Rafter/Truss 17000 30.0 0;0 0:1035 0.051 Exterior Wall 1:Wood Frame,Any Spacing 11680 19.0 0.0 0.068 0.074 Window 1:Vinyl Frame,Double Pane,Tinted,shgc 0.32 1400 --- - --- 0-333 0.520 Door 1:Glass,Tinted,shgc 0.27 135 --- --- 0.330 0.520. Floor 1:Heated Slab-On-Grade,Vertical 4 ft. 584 --- 10.0 --- --- (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Envelope PASSES: Design 30%better than code Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the Proposed New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.3 Release 1. Vq12 0o Principal)Ynvelope Designer-.Name Signatur Dat� Lighting and Power Systems Compliance-Certificate Proposed New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.3 Release I Data filename:C:\Program Files\Check\COMcheck-EZVV1ED,cck Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees F): 380 Building Use Method of Compliance: Whole Building Method Building Type Floor Area Medical and Clinical Care 34000 Project Description(check one): ;L,New Construction —Addition Alteration Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Inspection Approved Initial Date (Y/N) Controls,Switching,and Wiring Independent controls for each space(switch/occupancy sensor) Exceptions: Security lighting,building lobby/retail store/mall Master switch at entry to hotel/motel guest room Individual dwelling units separately metered Two switches,dimmer,or occupancy sensor in each space providing a uniform illumination pattern Exceptions: Only one himinair.e in space; An occupant-sensing device controls the area; The area is a corridor,storage,restroom,or lobby Automatic lighting shutoff control in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.ft Photocell/astronomical time switch on exterior lights Exceptions: Large covered areas requiring lighting during daylight hours Tandem wired one-lamp and three-lamp ballasted luminaires Exceptions: Electronic high-frequency ballasted luminaires not on same switch Transformers meet minimum efficiencies listed in Table 805.6.1 or 805.6.2 Interior Lighting Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 54400 30040 YES Exterior Lighting Type(s)of exterior lighting sources: Fluorescent Metal Halide %)4High-Pr. Sodium Exceptions: Specialized signal,directional,and marker lighting;lighting highlighting exterior features of historic buildings; advertising signage;safety or security lighting;low-voltage landscape lighting. Section 4: Comphance Statement The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the Proposed New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.3 Release 1. rincipal Lighting Designer-Name Signa� Da Lighting Application Worksheet Proposed New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.3 Release 1 Section 1: Allowed Lighting Power Calculation A B C D Total Floor Allowed Allowed Area Watts Watts Building Type (ft2) (watts/ffl) (B x C) Medical and Clinical Care 34000 1.6 54400 Total Allowed Watts= 54400 Section 2: Actual Lighting Power Calculation A B C D E F Fixture Fixture Description Lamps/ #of Fixture ID Lamp Description/Wattage Per Lamp/Ballast Fixture Fixtures Watt. (L)x E) 1 Treatment rooms/48"T8 32W/Electronic 3 275 96 26400 2 Exterior lights High-Pressure Sodium 70W/Electronic 1 12 70 840 3 Corridor lights Twin Tube 40W/Electronic 2 35 80 2800 Total Actual Watts= 30040 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies. Total Allowed Watts= 54400 Total Actual Watts= 30040 Project Compliance= 24360 Lighting PASSES: Design 45%better than code I Mechanical Compliance Report Proposed New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.3 Release 1 Data filename:C:\Program Files\Clieck\COMcheck-EZ\MED.cck Section 1: Project Information Project Name: MED-CENTER Designer/Contractor: SCHERMERHORN Document Author: A.LoCASCIO Section 2: General Information Building Location: Warren,New York Climate Zone: 15 Heating Degree Days(base 65 degrees F): 7635 Cooling Degree Days(base 65 degrees F): 380 Building Use Method of Compliance: Whole Building Method Pro' ct Description(check one): I/ONNcew Construction Addition Alteration Unconditioned Shell(File Affidavit) Section 3: Mechanical Systems List Quantity System Type&Description 1 HVAC System 1: Heating:Duct Furnace,Gas/Cooling: Split System,Capacity>=90-<135 kBtu/h, Air-Cooled Condenser/Multiple-Zone Section 4: Requirements Checklist Generic Requirements: Must be met by all systems to which the requirement is applicable 1. Load calculations per 1997 ASHRAE Fundamentals - 2. Plant equipment and system capacity no greater than needed to meet loads -Exception:Standby equipment automatically off when primary system is operating -Exception:Multiple units controlled to sequence operation as a function of load 3. Minimum one temperature control device per system 4. Minimum one humidity control device per installed humidification/dehumidification system 5. Thermostatic controls must have 5 deg.F deadband I -Exception:Thermostats requiring manual changeover between heating and cooling 6. Automatic Controls: Setback to 55 deg.F(heat)and 85 deg.F(cool);7-day clock,2-hour occupant override, I 0-hour backup -Exception:Continuously operating zones -Exception:2 kW demand or less,submit calculations 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow>3,000 cfin 8. Outside-air source for ventilation;system capable of reducing OSA to required minimum' 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly -Exception:Ducts located within equipment -Exception:Ducts with interior and exterior temperature difference not exceeding 15 deg.F. 10. Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts;UL 18 IA or 18 1B tapes and mastics 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment 12. Hot water pipe insulation: I in. for pipes'<--1.5 in.and.2 in.for pipes>1.5 in., Chilled water/refrigerant/brine pipe insulation: 1 in.for pipes<--l.5in. and l.5 in.for pipes>l.5in. Steam pipe insulation: 1.5 in. for pipes<=1.5 in.and 3 in.for pipes >1.5 in. -Exception:Piping within HVAC equipment -Exception:Fluid temperatures between 55 and 105 deg.F -Exception:Fluid not heated or cooled -Exception:Runouts<4 It in length 13. Operation and maintenance manual provided to building owner 14. Balancing devices provided in accordance with 603.15 of Mechanical Code for New York State Requirements Specific To:HVAC System I 1. Equipment minimum efficiency: Duct Furnace(Gas): 80%Ec 2. Minimum one temperature control device per zone 3. Newly purchased cooling equipment will meet the cooling efficiency requirements 4. Discharge dampers prohibited with fan motors>25 hp 5. Integrated air economizer required 6. Systems serving more than one zone must be VAV systems 7. Single-duct VAV terminals must reduce primary air before reheating 8. Controls capable of resetting supply air temp(SAT)by 25%of SAT-room temp difference 9. Fan motor demand<--50%design kW at 50%design flow-calculations required Section 5: Requirements Description The following section provides a more detailed explanation of the requirements listed in Section 4. Generic Requirements: Must be met by all systems to which the requirement is applicable 1. Design heating and cooling loads for the building must be determined using procedures equivalent to those in Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible,within available equipment options. -Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes.Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. -Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degree F deadband(a range of temperature where no heating or cooling is provided). -Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degree F during heating and setting up to 85 degree F during coolingb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power. -Exception:A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously. -Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h)or less. 7. Outdoor-air supply systems with design airflow rates>3,000 cfin of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 8. The system must supply outside ventilation air as required by Chapter 4 of the Mechanical Code for New York State.If the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels, the system must be capable of reducing outdoor-air flow to the minimum required levels. 9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces(spaces neither heated nor cooled)must be insulated with a minimum of R-5. Unconditioned spaces include attics,crawl spaces,unheated basements,and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When ducts are located within exterior components(e.g.,floors or roofs),minimum R-8 insulation is required only between the duct and the building exterior. Exception: Duct insulation is not required on ducts located within equipment. Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or Plenum does not exceed 15 degree F. 10. All joints,longitudinal and transverse seams,and connections in ductwork must be securely sealed using weldments;mechanical fasteners with seals,gaskets,or mastics;mesh and mastic sealing systems;or tapes. Tapes and mastics must be listed and labeled in accordance with UL 18 1A or UL 18 1B. 11. Mechanical fasteners and seals,mastics,or gaskets must be used when connecting ducts to fans and.other air distribution equipment,including multiple-zone terminal units. 12. All pipes serving space-conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in.for pipes<=I 1/2-in.nominal diameter 2 in.for pipes>1 1/2-in.nominal diameter. Chilled water,refrigerant,and brine piping systems: 1 in.insulation for pipes<=1 1/2-in.nominal diameter 1 1/2 in.insulation for pipes>1 1/2-in.nominal diameter. Steam piping: 1 1/2 in:insulation for pipes<=1 1/2-in.nominal diameter 3 in.insulation for pipes>1 1/2-in.nominal diameter. -Exception: Pipe insulation is not required for factory-installed piping within HVAC equipment. -Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55 degrees F and 105 degrees F. -Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. -Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control valve and HVAC coil. 13. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity(input and output)and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC system control maintenance and calibration information,including wiring diagrams,schematics,and control sequence descriptions;desired or field-determined set points must be permanently recorded on control drawings,at control devices,or,for digital control systems,in programming commentsd) complete narrative of how each system is intended to operate. 14. Each supply air outlet or diffuser and each zone terminal device(such as VAV or mixing box)must have its own balancing device.Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices,and supply air diffusers. Requirements Specific To:HVAC System 1 1. The specified heating and/or cooling equipment is covered by the New York State Energy Conservation Code and must meet the following minimum efficiency: Duct Furnace(Gas): 80%Ec 2. Each zone of a multiple-zone system must have its own temperature control device. 3. The specified cooling equipment is covered by Federal minimum efficiency requirements.New equipment of this type can be assumed to meet or exceed New York State Energy Conservation Code requirements for equipment efficiency. 4. Fans with motors>25 hp may not be equipped with discharge dampers. 5. An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate. An integrated economizer allows simultaneous operation of outdoor-air and mechanical cooling. 6. Systems serving multiple thermostatic control zones must be variable-flow systems. Zone terminal controls must reduce the flow of primary supply air before reheating,recooling,or mixing air streams. 7. The specified multiple-zone system is equipped with single-duct VAV terminals.These terminals must be equipped with dampers,air valves,or other means to reduce the supply of primary supply air to a minimum prior to reheating. 8. Multiple-zone systems must include controls capable of resetting the supply air temperature.by at least 25%of the difference between the design supply air temperature and the design room temperature. 9. Fans over 25 hp on a variable-flow system are specified to include flow controls that limit fan power consumption to 50°%of the design power consumption at 50%of the design-airflow rate.Manufacturer's literature and other supporting documentation must be submitted with permit application. Section 6: Compliance Statement The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the Proposed New York State Energy Conservation Construction Code requirements in COMcheck EZ Version 2.3 Release 1. The design professional shall provide to the code enforcement official a written certification that the required HVAC tests,system balancing,etc.,have been performed and the system is operating as designed. The design professional shall retain copies of the test reports to be provided to the code enforcement official,if requested. Principal Me6hanical Designer-Name Signatur Da MEMO TO FILE RE: SCHERMERHORN MEDICAL OFFICE BUILDING BAY ROAD MARCH 25,2003 On March 24, 2003, at approximately noon, I met with Rich Schermerhorn, Frank Dingman, from Electric, Donald Loveland from Commonwealth Inspection Agency to go over the requirement for an additional ground to be placed in the medical treatment rooms at the medical office building. Previous to this date, Mr. Loveland had stated that the MC Cable met the requirements of Code Section 517.13 of the National Electrical Code. Further review and consultation with electrical suppliers revealed that the electrical manufacturers will not state in writing that their MC Cable meets this requirement of Code Section 517.13 because they also manufacture a cable that has a fourth conductor for grounding that meets the requirements for hospital grade insulation. While there was disagreement as to whether the MC Cable provided in this building would meet this requirement, Electric has agreed to add a grounding wire to all the outlets and switches in the rooms pertaining to patient treatment. They would be running this ground wire through the boxes and the boxes would be installed with a hospital grade electrical outlet which would be visible at time of inspection. During this meeting, we identified all the rooms in a purple marker that were required to meet this requirement. It was also understood that Don Loveland will re-inspect this building to ensure that this grounding wire has been properly installed. This Department will also inspect to make sure that a grounding wire has been installed in the building, although we are not inspecting it for compliance,other than to verify that the wire is in the building and home run back to a panel box for grounding purposes. TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 518-761-8201 March 7,2003 Rich Schermerhorn 15F Birdie Drive Queensbury,NY 12804 Dear Rich: This letter is in reference to our conversation regarding the installation of a sprinkler system and work related to the ceiling of the medical office building currently under construction on Bay Road. This-letter.will serve as a STOP WORK ORDER that no furthei work on the sprinkler system or sheet rocking of the ceiling first floor can commence until such time as this.office has received a sprinkler plan approved and accepted by the Fire Marshal's office for installation Once that plan has been received and approved, this Department will go over what requirements the contractor must meet for,installation of the sprinkler system. This office will not allow the ceiling of the first floor to be sheet rocked and sprinkler heads installed through the sheet rock into the truss space. The piping must be installed prior to sheet rocking of the ceiling for inspection by the Fire-Marshal's office to ensure that all clearances to the sprinkler heads have been met. Also, a revised drawing needs to be submitted to show the changes in the access area to the pool basement. As always,if you have any questions,you may contact me at any time or Steve Smith,the Fire Marshal. Thank you for your attention in this matter. Sincerely, TOWN OF QUEEN BURY David Hatin,Director Building and Code Enforcement DHlmg Cc: Steve Smith,Fire Marshal "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO-LIVE" _._._. SETTLED 1763 y w INSTALLATION REQUIREMENTS 13-53 5-12 In-Rack Sprinklers. Figure 5-11.5.1 Positioning of sprinklers to avoid obstructions to dis- charge(ESFRsprinkler). 5-12,1 System Size. The area protected by a single system of sprinklers in racks shall not exceed 40,000 ft2 (3716 m2) of floor area occupied by the racks,including aisles,regardless of Ceiling the number of levels of in-rack sprinklers. 5-12.2 Type of In-Rack Sprinklers, Sprinklers in racks shall be ordinary-temperature standard response classification with r a nominal Kfactor of 5.6 or 8.0,pendent or upright. Sprin- �� j klers with intermediate-and high-temperature ratings shall be used near heat sources as required by 5-3.1.3. Exception: Quick-response sprinklers shall be permitted to be installed in racks. aA5-12.3 In-Rack Sprinkler Water Shields. V(, 5-12.3.1t In-Rack Sprinkler Water Shields for Storage of Glass I through IV Commodities. Water shields shall be pro- 1. 1 � �1 . vided directly above in-rack sprinklers,or listed intermediate level/rack storage sprinklers shall be used where there is more - .—-- than one level,if not shielded by horizontal barriers. .:5-1 L5.2* Isolated Obstructions Below the Elevation of opr,,,- 'tilers. Sprinklers shall be installed below isolated noncontinu- 5-12.3.1-In-Rack Sprinkler Water Shields for Plastic Stor- �ous .obstructions that restrict only one sprinkler and are age.`Where in-rack sprinklers are not shielded by horizontal located below the elevation of sprinklers such as light fixtures barriters,,water shields shall be provided above the sprinklers and'unit heaters. off listed intermediate level/rack storage sprinklers shall be used. Exception No.1: Where the obstruction is 2 ft(0.6 m)or less in width and the sprinkler is located horizontally I jt(0.3 m)orgreater from the 542A Location, Position, and Spacing of In-Rack Sprin- nearest edge of the obstruction. klers, (See,Section 7-4). Exception No. 2: Where sprinklers are positioned with respect to the 542:5 'Obstructions to In-Rack Sprinkler Discharge. In-rack bottom of obstructions in accordance with 5-11.5.1. sprinklers shall not be required to meet the obstruction crite- Exceptian No.3. If the obstruction is 2 in.(50.8 mm)or less in width ria and clearance from storage requirements of Section 5-5. and is located a minimum of 2 ft(0.6 m)below the elevation of the sprinkler deflector or is positioned a minimum of 1 fl(0.3 m)horizon- 5-13.Special Situations. tally from the sprinkler r5=``l3'I'Conceaied'Spaes. - 5-11.5.3 Continuous Obstructions Below the Sprinklers. g-13.1.1* AlI concealed space""s enclosed wholly or pa y by Sprinklers shall be arranged to comply with Table 5-11.5.1 for exposed combustible construction shall be protected by horizontal obstructions entirely below the elevation of sprinklers sprinklers. that restrict sprinkler discharge pattern for two or more adjacent sprinklers such as ducts,lights,pipes,and conveyors. Exception No. 1: Concealed spaces formed by studs ar joists with less than 6 in. (152 mm)between the inside or near edges of the studs or Exception No.1: If the obstruction is 2 in.(50.8 mm)or less in width x joists.(See Figure 5-6:4.1.4.) and is located a minimum of 2 ft(0.6 m)below the elevation of the Exception No.2: Concealed spaces formed by bar joists with less than tally from the sprinkler. ; sprinkler deflector is positioned positioned a minimum of 1 f t(0.3 m)lzarizon- 6 in. (152 mm)between the roof or floor deck and ceiling. - Exception No.2: If the abstraction is l f t(0.3 m)or less in width and Exception No.3. Concealed spaces formed by ceilings attached directly a located a minimum of 1 ft(0.3 m)horizontally from the sprinkler. �` to or within 6 in.(152 mm)of woad joist construction. Exception No.3: If the abstraction is 2 ft(0.&m)or less in width and Exception No. 4: Concealed spaces formed by ceilings attached di- Exception aminimum of 2.p{0.6 m)horizontally from the sprinkler: rectty to the underside of composite wood joist construction,provid- ed the joist channels are firestopped into volumes each not 5-11.5.31 Upright sprinklers shall be installed on sprigs exceeding 160 fts(4.53 ms)using materials equivalent to the web ' arranged so that the deflector is a minimum of 7 in.(178 mm) construction. above the top of the sprinkler pipe. Exception No.5: Concealed spaces entirely filled with noncombustible 5.11.5.3.2 ESFR sprinklers shall be positioned a minimum of insulation. 1 ft(0.3.m) horizontally from the nearest edge to any bottom 'Exception No. 6. Concealed spaces within wood joist construction chord of a bar joist or open truss. and composite wood joist construction having noncombustible insu- lation filling the space from the ceiling up to the bottom edge of the 5-11.5.3.3 Sprinklers installed under open gratings shall be of joist of the roof or floor deck,provided that in composite wood joist the intermediate level/rack storage type or otherwise shielded .'construction the joist channels are frrestapped into volumes each not from the discharge of overhead sprinklers. exceeding 160 fO(4.53 ors)to the full depth of the joist with material 5-11.6 Clearance to Storage (Early Suppression Fast-Response a equivalent to the web construction. Sprinklers). The clearance between the deflector and the top motion No. 7.• Concealed spaces over isolated small roams not ex- of storage shall be 36 in. (914 mm)or greater. )teed ngs55 f?(4,6,td2).in area. - 1999 Edison "" w 13--54 INSTALLATION OF SPRINKLER SYSTEMS Exception No.8. Where rigid materials are used and the exposed Sur- tieon s nprinkler shall be installed at the top of each trapped stiofaces have aflame lame spread rating of 25 or less and the materials have been demonstrated not to prapagate.fire in the farm in which they are 5.13.2.3 Where accessible vertical shafts have noncombustible installed in the space. surfaces,one sprinkler shall be installed near the bottom. Exception No.9. Concealed spaces in which the exposed materials are 5-13.3 Stairways. constructed entirely of fire�•etardant treated wood as defined by NFPA 703,Standard for Fire Retardant Impregnated Wood and Fire Retar- 5-13.31 Sprinklers shall be installed beneath all stairways of dant Coatings for Building Materials. combustible construction. Exception No.10: Noncombustible concealed spaces having exposed 5-13.3.2 In noncombustible stair shafts with noncombustible combustible insulation where the heat content of the facing and sub- stairs,sprinklers shall be installed at the top of the shaft and strate of the insulation material does not exceed 1000 Biu/ft2 under the first landing above the bottom of the shaft. (11,356 kj/m2). Exception: Sprinklers shall be installed beneath landings or stairways Exception No. 11: Sprinklers shall not be required in the space below where the area beneath is used for storage. insulation that is laid directly on top of or within the ceiling joists in _ an otherwise sprinklered attic. - 5-13.3.3* Sprinklers shall be installed in the stair shaft at each } tnmed studs floor landing where two or more doors open from that land- Exception No,12: Pipe chases under 1010 t2(0.93 m2)f b3 in into separate fire divisions. or wood joists,provided that in multi/loor buildings the chases are fir- g P estopped at each floor loor using materials equivalent to the floor*loor•construc- 5-13,4* Vertical openings. Where moving stairways, stair - tion. Such pipe chases shall'contain no sources of ignition, piping cases, or similar floor openings are unenclosed, the floor shall be noncombustible,,and pipe penetrations at each floor shall be openings involved shall.be.protected by-closely spaced sprin- klers in combination with draft:stops. properly sealed. The•draft stops shall be located immediately adjacent to 5-13.1.2 Sprinklers in concealed spaces having no access for the opening,shall be at least 1$in'(457 mm) deep,and shall storage or other use shall,be installed in accordance with.the be of noncmbustible or limited-combustible material that requirements for light hazard occupancy. will stay in place before and during sprinkle operation.Sprin- 5-13.1.3 Where heat producing devices such as furnaces or "klers shall be spaced not m0re'4than 6 ft (1.8 in apart and process equipment are located in the joist channels above a placed 6 in.to 12 in.(152 min to 305 mm)from the draft stop ceiling attached directlYA64tie underside of composite wood on the side away from the:`opening. Where sprinklers are joist construction that would not otherwise require sprinkler closer.than 6 ft (1.8 m),'crass baffies shall be provided in protection of the spaces;.tlie joist channel containing the heat- accordance with ra 6.3:4. producing devices shall be sprinklered by installing sprinklers Exception No. 1: Closely'spaced.sprinklers and drat t stops are not re in each joist channel,on each side,adjacent to the heat-pro- quired around large openings,such"as those found in shopping malls, ducing device. atrium buildings,and similar,structures where all adjoining levels and . _ g P st. spaces are protected by automatic sprinklers in accordance with this stan- 5-131.4°In concealed spaces'hauls ex ased cambustib a dard and where the openings have all horizontal dimensions between op construction, or contauniiig'exposed-combustibles;zri roc - ized areas,the combustibles shall be protected as follows: posite edges of 20 ft(6 m)-orgreater and an area of I000 f t2(93 m2)or (a) If the exposed combustibles are in the vertical parti greater' tions or walls around all spaced not portion ft(3.7 m)capart nor more qui Exceptionlosure,a single forconvenien openings within indtops and closely ividual dwellligunits that row of sprinklers p than 6 ft(1.8 m)from the inside of the partition shall be per- meet all of the following criteria: mitted to protect the surface.The first and last sprinklers in (a) Such openings shall connect a maximum of two adjacent sto- such a row shall not be over 5 ft(1.5 m)from the ends of the ries(Pierre ane floor only). partitions. (b)* Such openings shall be separated from unprotected vertical (b) If the expose combustibles are-in the horizontal lane> openings serving other flows lours by a barrier h a.pw r��nce rating p P equal to that required for enclosure of floor toor openings by NEFA 101®, the area of the mbustibles`shall"be ermitted to be rotecte with sprinklers on a light hazard spacing.Additional sprinklers Life Safety CodP r �e (c) Such openings shall be separate from corridors. shall be installed no more than 6 ft(1.8 in)outside the outline of the area and not more than 12 ft(3.7 iri)on center along tle (d) Such openings shall not serge as a required means of egress, outline.When the outline returns to a wall or other obsiructioPl although they can serve as a required means of escape. —the-last sprinkler shall,nat lie m e an Eft-(1:8-m) om tt e wall.or-obstruction. 5-13.5* Building Service Chutes. Building service chutes . ubbish)shall be protected internally by automatic (e.g.,linen,r 5-13.2 Vertu Shafts, sprinklers.A sprinkler shall be provided above the top service 5-13.2.1 One sprinkler shall be installed at the tap of shafts. opevninge f th openings at alternate levels m buildiabove the lowest service ngs over two above 1xception No. 1: Noncombustible or limited combustible, nonaccessi-• stories in height.The room or area into which the chute dis- vertical duct shafts. charges shall also be protected by automatic sprinklers. 'ion No. 2: Noncombustible or limited-combustible, nonaccessi- 5-13.6 Elevator Hoistways and Machine Rooms. al electrical or mechanical shafts. 'There vertical shafts have combustible surfaces, 5-13.61* Sidewall spray sprinklers shall be installed at the but sat more than 2 ft {0.61 in) shall be installed at each alternate floor level. tom of each elevator hoistway ,ring combustible surfaces is trapped,an addi- I above the floor of the pit. �Qo i I I � W U co -----_------------------------------------------------------ BAY ROAD ----- �\ 1 ---------------------------------------------------- ---------------------------------- yY0 I ``a e i------------------------�--��—�.�--���—�--��--�--���—�--�--��--�--�--�--��--��--�--��--��--�--�� �� t' I Al 1, \ � I fAll- I 1 I I ^ I WETLAND 1 — 1 f I 1 1 00 1La s « „C 1 I 1 I :S 39 162.0' 18 PARIWG SPA:.0I 1381.0, - 9 PARMG 5PACE5 , 1 = I - .+ ' ( .0' —� -AL I I �►1c1 I SITE LIGHT I 17, EAVE TRENCH _ I I 1 i I 1 1 1 1 FEAFM AD 4M DRIVE THRU EMPLOYEE PARKM i ♦ ♦ DAYCARE CENTER ' r ...R... ....... ..... .. V I '( .................................................... ......:.......+o .. .......... ./....... i........... ......................... .� /. ............................................................::.::....:.' :.::::...'.'.:'.':..:::::::. 3.. [tTfiD .iR1 1D.............................................................................................................................................................................................................. \ , A SITE CUP K H.......................................................................... �(i ..... .......... .......... .......... .......... .......... .......... .......... ..... . ............................................... a\ ...... uGHT .. /., :•''':.'.'.•.'.':...'..::.'.':::.:.'.':.'.'..'.'.'.'.'.'...'...'::.'.'.::.'...':.':.'...:.::...:.'...'.'.':..'.'::.::..:::.....'.'::.::::.:::...'::::::.::.::..:::.::::::.::.'.:::.'::..':::::::::.'.':.'..::.::..::.:::.'::.:::.:':..'::::.':::::.::::.'.:.:::. ...............................................................................%20R GAB:.'.::....::::.. . r... SITE...::: '::::'::::::::::':::::'::::':':::':::'::.............................................................................a%/ t.......................................................................................................... ..........................................................................--....................... . .................................................................L 1t... ...........................- ...................................................................\............................................................................................................................................................................................................................................. LfhI1 .............. .............................. ............#..............................................................................................................................1.Q" I IP.MT- - - -................................ ............. ................ ..... .......... .... _ . -.. - .......... ..............._................................ ..a ....._ ................'......................'.:. ..... .......................AUL ...... ......... .............. .t .. 3i i \\ / ::..'....................... ...................... ':: t...::'. :::'.:....:.':.:..'.':.:....................... .....................:......... ::::......:.... •.:':.::::::::::.::.:':. ; . ' r, �.:::::...:::.......................................................... ....... \ ... Q.' \ ♦ / C ., Ii.. .................... ......... O ................ .....................::y`• . :.•t:::.-:.�::.:::ri ' x.•-emu.., %_,., ..�,.i ........................... .................. ....... ...... �1y ........ ......./.. ........ r+ ... .A ....... ..Q ...... ....................... ..... .,t �+}.........................�.............................. / s�................ P............................... ........................ a ...%...................... ....................... ....................... ' .:::.::.'.:::.'.' . :.:::::.:::.'.':..'::.:. _ .':::..:.'.'. _ .::.::.:......: ::.'::.'.'.':::.::..' ..:. ':.'. ma IL ♦ ;z.; :::..':.: :.......:.: . .......:...: ::.:...:.:............ ............................ ......................... ........................ � / ...... ' -............................................. ............................ - • ��' . I o...... t......................................... x.......................... �R ............. ............................. :l P PA1 �1 f I t !. Jac Imo, ♦ i I I R 11 I AARIVAL 23 - {{ I AND PARICNQ \ • � • %Idip .11L a o F I i I 1 t i � \ S 1 , %'�Y \ •: I %C :. i \ :: 1, d- �:: AF7*It•:• i �tw I do % AIL no .. ....... 18" STOP�BAR \:':':':.:..:.:•:::_::. ::::::::':' :•.., .. "r \:::':::.....'... .::.. SITE / \ �..............' . LIGHT I ,! i/• I 'et%ly :au:b: WEIAND . • / \ 3\FAPER;: ♦ py ;op / %\ ::. . �` ;,{ Tyr: '` „� AL / Site Statistics — -- - • / Medical Office Buildin — Schermerhoryk�� TAX MAP PARCEL 29G.12-1-24 g \ \ \ �` Q•/ , / ZONING: PROFESSIONAL O` ICE i Building Permit File \, %,_ g le /7 %\ . \%f / SITE AREA 5.21 ACRES C22G.995 sf) D �!/ w :: /� , • 1, \ \ / (CCO) 517E UTILIZATION ? %\ \ \ ��-r'': \ �� ' �I.+c / BIA.D�IG AREAL 17.360 sf = 7.67 e \\ \� i C(OPY Lots 2, 3, and 4 Willowbrook Road i \ \ >rr :' = • s�.1ll_ ` / PAVEMENTS: 73.OG8 sf = 32.2Z 9'\ PERMEABLE AREA• 13G.5G7 sf G0.2% C30Z. REC&M e '� °° ' °` ~ ? Baybrook Prof. Park Subdivision 12" HDPE "\ \ EASE MT w/END SECT. \ � i1 AL REQUIRED PARKING: 1 per 300 GRO55 LEASEABLE SJr. INV. 308.3 % \\ . \ \ \ AL 33.920 GRO55 LEASEABLE 5F - 113 5PACE5 \AL BUILDING SETBACKS PROPOSED PARKING, PRO005ED REQURED 19 5PACE5 Location Plan scale 1" = 1600' \ ♦` \\ V-� ` ` NORTH FRONT (NORD13a 239.2' 30.0' BAY ROAD CTRAVEL COR.3= 75.88' 75.0' FRONT CSOUTI13v 174.G' 30.0' SIDES 7G.1' 10.0' Miller Associates LANDSCAPE ARCHITECTS 169 Haviland Road Queensbury, NY 12804 Nace Engineering PC CIVIL ENGINEERS 169 Havlland Road Queensbury, NY 12804 VanDusen & Steves Land Surveyors, LLC 169 Haviland Road Queensbury, NY 12804 G ACCESSIBLE PARKING SPACE PROVIDED BULDING HEIGHT - 3G' C40' MAXIMUM) MEDICAL OFFICE BUILDING BAYBROOK PROFESSIONAL PARK Bay Road, Town of Oueensbury, Warren County, New York Owner/Applicant: 5chermerhorn Properties, Inc. 15F Birdie Drive, Oueensbury, NY 12804 A16-U Y -LU14MAM a I i LG A3 51MILAK I Irw- rSvvnvcry r DAYCARE CENTER, AND CHAIRMAN t June 24, 2002 - Respond to C.T. Made c mniw is 2. .J* 10, 2002 - PwIm Li" and Add Approval Block. DATE SITE LAYOUT AND UTILITY PLAN SP- I DATE- MAY 29, 2002 SHEET I OF 4 1 I I ( I n I CO 7= -.. .. . ..... WETLANDWAOW • - — -- -. ' . „ , ♦ � t ♦ AL ' SECTION \ \ \ ./ s•• OWAcc 0400e .\ \ 12"/ I HAY BALE DAM - CHANNEL FLOW �',- � �' ;�• ` � � \�. �� ` \\� ° ° `F CL V "� 3°a j = ' Erosion and Sediment Control Notes Site Notes NOT TO SCALE .. ;f �`. �� \� ~" \. \ \ \ \•� %_- INV3 ° ' 'y`' / / 1. DURING EARTHWORK PHASES. SEDIMENT TRAPS CHAY BALE DAMS) + AL I. EVIDENCE OF EXISTING UTILITIES 15 INDICATED FOR THE \ ♦ \ \ \` CULL v T �� / SEDIMENT GONTOL FENCING SHALL BE N5TALLED IN DRAINAGE 5WALE5 AND CONVENIENCE OF THE CONTRACTOR. IT IS THE SOLE RESPONSIBIL.IYT ''♦ \ `• \ \ \ ♦ w .o G /AL / /lei / AT THE TOE OF GRADED SLOPES A5, INDICATED ON THE PLAN. OF THE CONTRACTOR TO COORDINATE THE FIELD LOCATION OF \ \ ALL UTILITIES, WITH THE UTILITY OWNERS. j \ \ \ \ \ \ . r / 2. AFTER EVERY STORM THE SEDIMENT TRAPS \ \ MUM \♦ \ \ v 9'\ \ \ \ 2-4r HOPE n*. • ! SHALL BE IN5PECTED FOR FAILURES OR DISPLACEMENT. AND ANY FAILURES ♦ o �, \ cuLVERlS • 2. IT 15 THE RESPONSIBILITY Of THE CONTRACTOR TO PROTECT \ \ '. s INV. 305.4 (UP) / SHALL BE CORRECTED WITHIN 24 HOURS. •� \ w 12" HDPE\ \ ,` \ \ \ \ \ \ \ 1 V, 3�1 (DN) 40 ALL EXISTING UTILITIES FROM DAMAGE DURING EXCAVATION. GRADING NV. ND oa3 \ ` v \ \ '� \ \ \ AND CONSTRUCTION. 3. ALL BARE EARTH AREAS SHALL BE SEEDED AND MULCHED \ �`.� \ \ ♦ \ \ \do WITHIN 48 HOURS OF SPREADING TOPSOIL TO PREVENT EROSION. 3. THE CONTRACTOR SMALL DISPOSE OF ALL DEBRIS AND EXCESS 4. THE CONTRACTOR SHALL COMPLY WITH THE NEW YORK GUIDELINES MATERIAL OFF OF THE PROJECT SITE N A LEGAL MANNER. \ � I ` 1 \ \ , 1 / \ \ ` o\ '�s,,� \ / FOR URBAN EROSION AND SEDIMENT CONTROL AS PUBLISHED BY 36' FENCE POST. 10 oc MAX \ _ \ \ / FOR URBAN ER051OTHE EMPIRE STATE CHAPTER OF 4. THE CONTRACTOR SHALL STAKE THE LOCATION AND GRADES DRIVEN 16' FIN INTO GROUND :� '' \\ /j if .`3oe.s/'♦♦ \ �` \ "\ \ %�,� — — J / THE SOIL AND WATER CONSERVATION SOCIETY. OF ALL NEW WORK IN THE FIELD PRIOR TO STARTING WORK. ANY DISCREPANCIES OR QUESTIONS SHOULD BE IMMEDIATELY `V 511t STOP FABRIC \ / / + ; "I\\ \ \ � ` 5. NO SLOPE SHALL EXCEED 3 feet HORIZONTAL TO 1 foot VERTICAL. BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION FLpyy EMBED �' MN N BROUND i r / \ ♦ \ \ \ % /\ BEFORE PROCEEDING WITH THE WORK. UNDISTURBED GROUND TECTS • _— : — - _�_• ,`f i 308 g ,♦ ,69 Haviland Road Queensbury, NY 12804 p .ke 24,2002 ReooxMEDICAL OFFICE BUILDING &RAD1NG AND' Mi Miller Associates UNOSCE A CHI \♦ ,\ : 2 to C.1© 20Q2 - Revieets D= A PLAN 3oe.sJ^�♦ \� BAYBROOK PROFESSIONAL PARK \ - Nace Engineering PC CIVIL ENGINEERS 5EDIMENT CONTROL. FENCE '. `.'' �► 169 Haviland Road Queensbury, NY 12804 warren Gaunt a and Add Approval \ ` Boy Rood, Town of Oueensbury, y, New YorkSk)dL NOT TO SCALE .� 3o8•g -:; 'Jr ` ��� \ \ ; NORTH Owner/A licant: 5chermerhorn Pro erties, Inc. �J —:2 Off f 1 \ \ \ 11 1 VanDusen & Steves Land Surveyors, LLC pp p / a o ` \ \ �``\ \\\ \ ' \ ��� _ 169 Haviland Road Queensbury, NY 12804 I5� $Irdle Drive, Gtueensbury, NY 12804 DATE APFAL 30, 2002 SHEET 2 OF 4 L5- TOP COURSE ASPHALT 2" BINDER COURSE ASPHALT 0o a oo o GRANULAR SUBBASE COURSE NYS DOT SECT. 304. TYPE 4 o o�p COMPACTED TO 95X STD. PROCTOR - - SUBGRADE COMPACTED t0 90X STANDARD PROCTOR INSTALL MAY BALE DAM AROUND GRATE UNTIL AREA IS PAVED OR LAWN ESTABLISHED min FLASHED GRADE MEAVY DUTY FRAME AND GRATE FRAME TO BE MORTARED TO TOP OF STRUCTURE •4 WRAP GRATE WITH FILTER FABRIC UNTIL AREA 15 PAVED (� To RCE E NT a WE TO BE MORTARED IN d sum r 121, DEEP Bin. 4. J roll 2'--G" min roll min min CATCH BASIN DETAIL NOT TO 5CALE INSIDE+- V'/.I —OUTSIDE BUILDING WALL PROVIDE PROPER VENT THROUGH ROOF ACCE55 TO CLEANOUT5 AND BACKWATER VALVE GLEANOUT AT GRADE J J FLOOR SLAB ON GRADE a 3 FINISH GRADE CLEANOUT RISER 4' ECCENTRIC 4• REDUCER 1/4•/FT — 4' G' 4' HOUSE TRAP 1/8'/FT. W/2 CLEANOUTS 4' WYE 1/8 BEND COMBO SEWER LATERAL DETAILS OUND Le )X VALVE INSTALL TMRUST BLOCK BEHIND TAPPING SLEEVE EXISTING MAN CONNECTION TO EXISTING WATER MAIN NOT TO SCALE 2-#4 SMOOTH RUBBED FN511 on CURB 3/8" x 3/4" DEEP TOOLED JOINT RADUS V, 5'• BROOM FNSt't PERPENDICULAR TO WALK CONCRETE WALK SEE DETAL " • G" x G- NO. G/G WOVEN WIRE MESH ASPHALT ' Q 8- GRANULAR SUBBASE COUItSE NYS DOT SECT. 304. TYPE 4 0 0 •_ , 08 COMPACTED TO 95X STD. PROCTOR Cp�) S O'bC?6' o D .'• o • o t9 c> o 16 cjg;>o o F-°--t=- SUBGRADE COMPACTED TO G" 90X STANDARD PROCTOR Y. INTEGRAL CONCRETE CI�B NOT TO SCALE INSTALL RIP RAP ON 51DE5 AND TOP OF CULVERT END FLARED END SECTION W/ BOLTED COUPLING BAND 12" min. G-8- RIP RAP SEE PLAN FOR LENGTH � FINISHED GRADE 18" CMP CULVERT 1 0 BURY END 4" INTO SOIL min 4 aF2 STONE =- -- - GEOTEXTILE FABRIC WYE. ' 450 OR Go PLNI NOT TO SCALE ADAPTER FITTING if REQUIRED 450 OR 300 BEND AS REQUIRED 4" SERVICE CONNECTION z FINISHED GRADE 450 OR 300 BEND 3'-6" AS REQUIRED min COVER 19. min GRADE Cl/8"/ft) LL 4- SERVICE CONNECTION PIPE BEDDING MAIN SEWER AS REQUIRED SWTION ;1 SEWER CONNECTION NOT TO SCALE NOTES ALL SEWER SERVICE AND CONNECTION WORK SHALL BE N COMPLIANCE WITH THE TOWN OF QUEENSBURY. EXIST. GROUND ADJUSTABLE VALVE BOX GATE VALVE WIT" NON -RISING STEM CONCRETE 4* MIK NOTE VALVE BOX 15 NOT TO REST ON VALVE OR PPE LIFER. VALVE INSTALLATION DETAIL G BUILDING 'r • 1/2" RADIUS 1" 5" A V.r•, ., moo? p • f 0 ,COMPACTED SUBGRADE TO 90% STANDARD PROCTOR CONCRETE ORB ° 4°0°P ° o ALU MK M EDGING 08 (bO ° 0 op opo ►o 7O°° o #2 BROKEN STONE o ° ° 4P ° o 0 0 000 %O o ° °op opo FILTER FABRIC 6 ° 0 :c) 0 "GRADE EAVE TRENCH DETAIL GRADE AT UNPAVED - AREAS RESTORE TURF �11'�lEl NOT TO 5 MAC11 E BACICFLL W/ NATIVE MATERIAL COMPACT EXCAVATE TRENCH WDTM N 11-0' LIFTS MINIMUM WIDTH EQUAL C4' MAX. SIZE) TO PIPE PLUS 2.0 FT. ►+ TO 95Z MODIFED PROCTOR 3 inIL. OLED SCORE OIN SMOOTtt FORM FINIS" on CURB BROOM FINISH SURFACE TYPICAL SEE PLAN V o OMINAL PERPEMACULAR TO WALK EXPANSION JOINT TOOLED SCORE JOINT EXPANSION JOINT SEE PLAN. 25' or. ow LAWN 1/4" R. 2/2" DEEP 3/8" COMPRESSIBLE FILLER WITH ZIP STRIP + SEALANT GXGXG/G WWF TOOL BOTH EDGES TOP OF SEALANT 1/2" BELOW FN. CONC. Yti/��/� /,�/,`, � > � .• .4k 4.000 pal CONCRETEGROOM • PN5Ft i\ in PERPENDK3ULAR rf�: ` e TO WICK DIRECTION o` a : o ' GRANULAR SUBBASE { oa 2- NY5 DOT SECT. 304. TYPE 4 O o0 000 oo, .08 COMPACT TO 95X STD PROD ro" GRANULAR SUBBASE COURSE - _ - _ /• NY5 DOT SECT. 304. TYPE 4 1 1/2 COMPACTED TO 95X STD. PROCTOR ' , ' ' L. . 3"TOOLED EDGE. 1/4" RADIUS min SUBGRADE COMPACTED TO 90X STANDARD PROCTOR CROSS SLOPE- 1/8" TO 1/4'* PI.µ per FOOT CMAX 5/5- per ft-) n CONCRETE WALKS NOT TO SCALE SELECT GRAM" MATERU L C1OOZ PASSING 21 TO 18' ABOVE PPE. "AND BAC KFILL. G' LIFT. PPE BEDDING ro' DEPTH. SAND. GRAVEL OR CRUSHED STOPS CTO 1-1/2•. 1. AT CONCRETE WALKK$ AND CUTtBS. SAWCUT EDGES AND REPLACE TO MATCH EXISTING. PIPE EXCAVATION 4 SACKPILL DETAIL RUBBER HOSE FRICTION GUAPJ) GUY WIRE 3" dia. CEDAR STAKES 8 ft LONG 3" SHREDDED BARK MULCH 3" HIGH SAUCER AMENDED PLANTING SOIL NOTE -- - ALL TREES 3" CAL NER AND LESS SHALL BE STAKED AS SHOWN USING THREE STAKES TREE PLANTIN6 4 STAKING DETAIL NOT TO SCALE ORNAHWAL GLOBE MUM 250 WATT MGM WSOME SCUM CWATTAGE LIThONIA A25 2505 Gt5 OR EQUAL rum Au."K" ORNAIETRAL POST 12' HUM - COLOR OLAGK f_ I /yX.lil�flKfi• J. -- - -AM. � EVERGREEN PLANTING DETAIL NOT TO 50ALE NOT TO SCALE HOSE FRICTION GUARD E 3" dia. CEDAR STAKES 8 ft LONG 3" SHREDDED BARK MULCH 3" HIGH SAUCER AMENDED PLANTING SOIL a- ORNArtNTAL GLOBE rlXl 250 WATT MIG9 MM65M SOM" CWATTAG: UTMONIA A25 1505 GO OR EQUAL FLUTED ALIMU M ORNAMENTAL POST 12' MIEIGIT IN PAItlQrG AREAS -COLOR ix ACK 10' MMGKT ALONG Bl"NG - COLOR BLACK / ir 0, 1,Er!AA - INS /�� r , A •if mm - SPACING VARIES SEE PLANTING PLAN NOT TO SCALE 2" FINE SHREDDED BARK MULW 3" SOIL SAUCER SHRUB PLANTING DETAIL AMENDED PLANTING SOIL I NOTEl THIS DETAIL SHALL APPLY TO ALL GROUND COVER. PERENNIAL and ANNUAL BEDS. NOT TO SCALE 3" SHREDDED BARK MULCH 3" HIGH 5AUCER AMENDED PLANTING SOIL NOT TO SCALE NOT TO SCALE NOT TO SCALE