Loading...
AST-0555-2021 Office Use Oniy ACCESSORY STRUCTURE Permit#: T �cJ — 2021 roar:o£Ctucc 6�;�• PERMIT APPLICATION permit Fee:$ Zb0 742 Bay Road,Queensbury,NY 12804 Invoice#: 40 w [[ P:518-761-8256 www.gueensbury.net Flood Zone? Y ( I�) Reviewed By: j Project Location: 43 Zenas Drive, Queensbury, NY 12804 Tax Map ID#: 301.12-3-43 Subdivision Name: Cresthaven PROJECT INFORMATION: TYPE: 2 Residential ❑ Commercial, Proposed Use: STRUCTURE: ❑ Boathouse(with or w/o sundeck) ❑ Canopy ❑ Carport ❑ Cell Tower ❑ Deck ❑ Detached Garage(>300 s.f.) ❑ Dock ❑ Gazebo ❑ Pavilion ❑ Pole Barn ❑ Porch ❑ Ramp ❑ Shed (<300 s.f.) ❑ Solar Panels (w/o rafter upgrades) ❑ 3-Season Porch 2 Other: Workshop Building SQUARE FOOTAGE OF STRUCTURE: ist floor: 280 Square Feet 2nd floor: Total square feet: 280 Square Feet Brief description of scope of project: 14' x 20' building to be constructed on a pier foundation with a plywood deck to be used as a woodworking shop. ECEDd � . JUL 21 2021 TOWN LpING 8 CODES Y Accessory Structure Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Jonathan Wood Mailing Address, C/S/Z: 43 Zenas Drive, Queensbury, NY 12804 Cell Phone: 518-538-1614 Land Line: N/A Email:jonathangarrywood@gmail.com ® Primary Owner(s): Name(s): Same as above. Mailing Address, C/S/Z: Cell Phone: Land Line: Email: Check if all work will be performed by property owner only ® Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: Email: "Workers' Comp documentation must be submitted with this application** • Arch itect(s)/Engi nee r(s): Business Name: Contact Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: Email: Contact Person for any questions regarding this project: Cell Phone: Land Line: 2 Email: Accessory Structure Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ 9,000 2. Are there any structures not shown on the plot plan? AYES ❑NO Explain: 8' x 10' storage building located on the back corner of the property. No permanent foundation. 3. Are there any easements on the property? ❑ YES 2 NO DECLARATION: I. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Jon than W od SIGNATURE: DATE: 7-21-2021 Accessory Structure Application Revised January 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) Two (2) full sets of plans NJ--b Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 115 Wind Floor Loads 40 psf (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf ` Calculations Decks 40 psf Wind design for lake front properties Window schedule with glass size & main doors/Air leakage< .5 cfm for doors, < .3 cfm for 4 windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door Emergency Escape or Bedrooms& Habitable Space Above-grade: 5.7 sq. ft. / Grade: 5.0 sq. ft. Iv 24" (h) x 20" (w) minimum 44" maximum height above door Window control devices 24" or less 2"d story or 72" above grade Egress window from basement 5.0 sq. ft. Floor system sizing per table 502.3.1 Residential check ERI or Prescriptive method U� Driveway length: 300' or more-12' width required/500' or more, turnaround required f Foundation drainage on plans,if required d jl- 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10' where required/joist spans pg. 127 & Ice & snow shield—24" from exterior wall Platforms at exterior doors Stairway headroom 6'8"; all stairs 36" width Stair run and rise Winder run and rise rJ Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Bathroom fixtures—proper clearance �a Hall width-36" width Handrails more than four risers on open sides Railing &guards > 30"/basement stairs included/closed risers more than 4" in height Safety glazing notes for required areas Garage fire separation:%" gable end/5/8" under living space &%" on walls/20 min. door and closer Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation Roof over 30"—22" x 30"/Crawl spaces 18" x 24" access Residential Plan Review Revised March 2018 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' of sleeping area Soil test results, if required Septic to well or water line separation �'- All paperwork signed Note on plans energy saving light bulbs 75% 1� Blower door test agency paperwork 1� Floodplain Permit required —check map: 2 feet above flood elevation �t Hurricane clips required Ij ` Floors less than 2 x 10 covered by W gypsum or 5/8" wood panel Manuals S &J required for heating system. Cold air return hard piped Separate room for draft HVAC or hot water heater with fresh air rj HRV shown and calculations rV Baffles at eaves for insulations and knee walls N Makeup air for range hood >400 cfm Continuous header for garage doors to end wall Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised March 2018 Overview of the project 1 The attached blueprint and drawings are for a 14' x 20' building to be used as a hobby woodworking shop. Rather than building on a concrete slab as the prints show, this building will be built on a %" plywood deck supported by a post and pier foundation. Jon Wood 43 Zenas Drive Queensbury, NY 12804 515r � 5 � 8 1,6 1 pSCE0VE JUL 21 2021 TOWN OF QUEENSBURY BUILDING&CODES 301.12-3-43 AST 0555-2021 Wood, Jonathan 43 Zenas Dr `. Workshop 280 s.f. AF'1 , 'f. -_ •V 19.G„ Mary CautSic��e�c� � c>rsJr cs e b, clej �I ,l1 g r' L r- gT ea- 77 P-r ---.> I I f 1 s �: �e.�w��rir bQAnR� I�► 1� 1 1 . - ' 1. THE TOTAL COMBINED HEIGHT OF BirrOOTSYSTFNIS(A) FINISH GRADE FOOTING FORM MUST NOT EXCEED THIRTE5N FEET(13'), 2. SCREW CONSTRUCTION TUBE TO FOOTING FORM WITH e- A MINIMUM OF FOUR(4)3/4"#8 WOOD SCREWS. ON UNDISTURBED GROUND OR 4"-6"COMPACTED GRAVEL- 4. BACKFILL MUST BE PLACED UP TO A MINIMUM OF 2'TO A MAXIMUM OF 6FROM THE BOTTOM OF THE FOOTING FORM. THS OACKFILLIS INTENDED TO HOLD THE FOOTING FORM ." PLACE, 5, BACKFILL SHOULD BE CONSOLIDATED WITH A MANUAL PLATE TAMPER OR P '2 X 4"ON END. DO NOT STRIKE CONSOLIDATE SO AS TO DISTORT THE SHELL OF THE FOOTING FORM. 8.CHECK ALIGNMENTOF CONSTRUCTION TUBE AFTER 2' ' UNDISTURBED GROUND OR BIGFOOT SYSTEM FOOTING FORM 4�8^COMPACTED GRAVEL BELOW GRADE APPLICATION 6716 TITLE � . ' K— �TE� 18 FEB2OOU | |snssT O 1 �F1 > ' 1' \ | / c Post and Beam Details Beams Three Pressure Treated Double 2" x 8 beams spaced 7' on center across the 14' dimension of the building. Each beam is supported by three 12" concrete piers spaced 10' apart (see pier details). Posts Pressure Treated 4" x 4" Fasteners Post to Beam: Simpson Strong-TieBC Galvanized Post Cap for 4x Nominal Lumber or equivalent Post to Pier: Simpson Strong-TieABA ZMAX Galvanized Adjustable Standoff Post Base for 44 Nominal Lumber or equivalent Post Base to Pier: 1/2 in. x 8 in. Hot Galvanized Anchor Bolt z�;yek .,..;^�•';,ice%.. e,,a.4"Adr'•'A;b' Fh i S l i s P a� -14 VO o-} l no i I I TOwn of Queensbury Interactive Mapper https:flqbycis.queensbury.net/,,vebapp/default.htn-d?pid=301.12--' Town Of Queensbury Interactive Mar%-,,er AA A- ............ a Selected Parcel: 301.12-3-43 .................................... .......... 'TID '14827 • 16 INEWNUMBER 1301.12-3-43 --j V'r, o .... ...... iT ........................ .............. pe-op� a z" 0 20 40ft 7/2 1/202 1. 10.00