2002-811 TOWN 'OF QUEENSBU,RY
-
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Commuiuty Development-Building&Codes (518)761.8256
CER"I"IFICATROF OCCUPANCY
Permit Number: a20020811 Date Issue: Wednesday,December 03,2003
This is to certify.that<work'requested to.be done-as',shown by?ermit Number :M 420020$11
has been completed,
Tax Map Number: 523400.302.007-0001-043-000.0000
Location: 265 BAY RD.
Owner: C.R. BARD INC USCI DIV
Applicant: C.1 BARD INC USCI'DIV
This structure may be.occupied as a:
By Order of Town Board
Commercial I Industrial TOWN OF QUEENSBURY
Duector of Building&Code Enforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20020811 Application Number: A20020811
Tax Map No: 523400-302-008-0001-003-000-0000
Permission is hereby granted to: C R BARD INC IJSCI DIV
For property located at: 2-10 BAY Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: C R BARD INC USCI DIV Conunercial/Industrial 1,000,000.00
ATTN: ACCTS PAYABLE 289 BAY Rd Total Value 1,000,000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
RON CTREFN/DAN BRI JNO
793-2531 X259: 793-4141
NY 12804-0000
Plans&Specifications
2002-811 289 Bay Rd.
Construction of a 9,800 sq ft commercial/industrial building per plot plan and specifications.
$1,470.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, September 26,2003
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
' ---`
Dated at the TZW7;7? ,�ay, September 26,2002 "L
LF*`� W,
SIGNED BY for the Town of Queensbury.
Director of Building&Code nforcement
Building Permit Application
Town of Queensbury-Dept of Community Development, 742 Bay Road, Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File'No.
No inspection will be made until applicant has received a Fee Paid
valid building permit. All applicants' spaces on this Rec. Fee Paid
application must be completed and must appear on the- Reviewed By
application form. a
Applicant: C 'a P 12 T> Owner: 15 vo, S'FP '0
Address: IZ6 Address: 5
-,�Fjvss
Phone# RY
,:?- ?-&-3/ 2C 2-S-9 Phone#( ) - U,
Email Address: Email Address:
q--.3
Property Location: Lot Number: House Number W7/
Subdivision Name: Tax Map Number: ' 3o e13
Q New Building: residence PhQaQrnm�ercial Estimated Market Value of Construction: $
c3 Addition: residence/ commercial
If an Addition,what will use of new addition be?
u Alteration: residence/ commercial
U No change to exterior size: residence com'l
C3 Other work(describe
Check Occupancyinformation Is'Floor 21d Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
U Single family dwelling
o Two family dwelling
U Townhouse
0 Multifamily dwelling
#of units
C3 Office
L3 Mercantile
-0 Manufacturing 0
0 -1 car detached garage
U 2 car detached garage
0 3 car detached garage
13 1 car attached garage
0 2 car attached garage
0 3 car attached garage
e
0 Storage building-
commercial
0 Storage building-
residential
C3 Other
What is the proposed height of the structure IY-feet inches
Will any second-hand or ungraded lumber be used? If so, for what? /14)
Type of Heating System: electric/ oil e`g�a pod forced hot air/ baseboard t othet:
Number of Fireplaces to be installed Number of Moodstoves to be installed
List below the person(s)responsible for super-vision of work as regards to building codes:
Zame Address Phone Number
Builder 3.
Plumber 7 -13 -J / 'fl
Mason
Electrician
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
withwhether ci ie noted,and that such work is authorized by the owner. Further,it is understood that I/we shall
- r if, 0
Ir 0 of C
.o
to a�
ub t pr fl ate of C inpliance being issued,as requested by the Zoning
P
s ) i( to a Cer' of
tr or Dir o o "up Em y or e=
'dtra 2:-tcd'YCod2 Certificate
by a licensed surveyor;drawn to scale,showing actual
rato t 1 c 'o f al c S c
Signature: owner,-owner's agent,architect,contractor
ItIspector's No
Date 20
COMMONWEALTH ELECTRICAL INSPECTION SERVICE INC.
(Consulting and Fire Inspection Services)
(incorporated in the states of Maryland,New York,Pennsylvania,Delaware and West Virginia)
Desiring Certification of Approval, application is made for inspection of electrical'installation in the premises
described below.On demand,applicant agrees to pay for inspection service in accord with schedule of charges.
PLEASE P�RNT- §
Type Bldg. ❑LJ DWG Other .............
Owner......... .............. ....... ----------- .......*'*"*....... ... Building
Occupant....61,11. ........................................................................ Permit No.
JobLocation...... ........F4.q......... 0.................................City......................................................................... State ........................
County ......-(,.U.... . .......................Twp........................................M/C#.......................................... Swimming Pool—New El Old El
Directionsto Job Site ..........7-�7.7....... ......n.......... ...............................................................................
....................................................................................................................................................................................................................................................
....................:................................--.......................................................................................................-...........................................................................
Application For Rough Wiring El Fixtures El Service El or ....--...................................................................................................................
Work—New El Additional D Bldg.—New 0 Old❑ Ready for Inspection .............................................---........
APPLICANT'S LICENSE CENSE 0 PERMIT a
PLEASE PHONE#
PRINT NAME NAME OF
APPLICANT'S
ADDRESS UTILITY
OFFICE TO
CITY STATE ZIP CODE BE NOTIFIED
SPACE BELOW FOR USE OF INSPECTORS ONLY
ROUGH WIRING AMP SERVICE
OUTLETS EQUIPMENT PUMP
SWITCHES HEAT OVEN
PUMP
SURFACE GARBAGE
RECEPTACLES UNIT DISPOSAL UNIT
MEDIUM BASE RANGE DISHWASHER
FIXTURES
MOGUL BASE WATER DRYER
FIXTURES HEATER
FLUORESCENT AIR AMP. RECEPTACLES
FIXTURES CONDITIONER
MERCURY VAPOR OR WIRING&CONTROLS FOR BURNER FRAC.H.P.
QUARTZ FIXTURES I VENT FANS
MOTORS:H.P. 118 1 116 1 1/4 113 112 1 3/4 1 1 11-1121 2 1 3 1 5 7-11 10 15 20 25 30 40 1 50 1 75 11001
MARK NUMBER
OF EACH SIZE
I I I
Inspector's Comments:
OFFICE USE ONLY WORK INSPECTED NOTIFIED REPOR 0
cr TED < -j0 FEE PAID
SERVICE DATE CON- TOTAL $
Date Repeived: TRACTOR
R.W.DATE OWNER CHECK NO.
FINAL DATE OCCUPANT CHARGE
Certificate No.:
CERTIFICATE NEEDED AGENT CASH
Date Sent: DYES ODUP
INSPECTOR
Progress El
THIS APPLICATION EXPIRES ONE YEAR FROM DATE MAKE ALL FEES PAYABLE TO C.E.I.S.INC.
WHITE/OFFICE PINK/INSPECTOR YELLOW/OFFICER GOLD/CUSTOMER
Envelope Compliance Report
Proposed New York State Energy Conservation Construction Code
COMcheck-EZ Software Version 2.3 Release I
Data filename:Untitled
Section 1: Project Information
Project Name: C.R.Bard Building 5A Addition
Designer/Contractor: Rist-Frost Associates P.C.
Document Author: K.J.Stankiewicz
Section 2: General Information
Building Location: Warren,New York
Climate Zone: 15
Heating Degree Days(base 65 degrees F): 7635
Cooling Degree Days(base 65 degrees F): 380
Building Use Method of Compliance: Whole Building Method
Building Type Floor Area
Storage,Industrial and Commercial 9753
Project Description(check one):
New Construction Addition Alteration —Unconditioned Shell(File Affidavit)
Section 3: Requirements Checklist
Air Leakage,Component Certification,and Vapor Retarder Requirements
Inspection Approved Initial
Date (Y/N)
All joints and penetrations are caulked,gasketed,
weather-stripped,or otherwise sealed
Fireplaces installed with tight fitting
non-combustible fireplace doors
Dampers integral to the building envelope are equipped
with motorized dampers
Cargo doors and loading dock doors are weather sealed
Recessed lighting fixtures are sealed or gasketed
Windows,doors,and skylights certified
as meeting leakage requirements
Component R-values&U-factors labeled as certified
Vapor retarder installed
Climate-Specific Requirements
Gross Cavity Cont. Proposed Budget
Component Name/Description Area R-Value R-Value U-Factor U-Factor
Roof 1:Non-Wood Joist/Rafter/Truss 9753 0.0 25.2 0.039 0.051
Exterior Wall 1:Metal Wall without Thermal Blocks 6442 0.0 23.1 0.042 0.074
Window 1:Metal Frame with Thermal Break,Double Pane
Clear,shgc 0.65 108 --- --- 0.580 0.520
Door 1: Solid 84 --- --- 0.240 0.120
Door 2: Solid - 79 --- --- 0.160 0.120
Floor 1:Unheated Slab-On-Grade,Vertical 4 ft. 350 --- 15.1 --- ---
(a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements.
Envelope PASSES: Design 35%better than code
Section 4: Compliance Statement
The proposed envelope design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application. The proposed envelope system has been designed to meet
the Proposed New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.3
Release 1.
Principal Envelope Designer-Name Xiggnat56e� Date I
Mechanical Compliance Report
Proposed New York State Energy Conservation Construction Code
COMcheck-EZ Software Version 2.3 Release I
Data filename:Untitled
Section 1: Project Information
Project Name: C.R.Bard Building 5A Addition
Designer/Contractor: Rist-Frost Associates P.C.
Document Author: K.J.Stankiewicz
Section 2: General Information
Building Location: Warren,New York
Climate Zone: 15
Heating Degree Days(base 65 degrees F): 7635
Cooling Degree Days(base 65 degrees F): 380
Building Use Method of Compliance: Whole Building Method
Project Description(check one):
_New Construction —Addition _Alteration —Unconditioned Shell(File Affidavit)
Section 3: Mechanical Systems List
Quantity System Type&Description
1 HVAC System 2: Heating:Duct Furnace,Gas/Cooling:Rooftop Package Unit,Capacity>=760
kBtu/h,Air-Cooled Condenser/Multiple-Zone
1 Water Heating l: Service Water Heater
Section 4: Requirements Checklist
Generic Requirements: Must be met by all systems to which the requirement is applicable
[ ] 1. Load calculations per 1997 ASHRAE Fundamentals
[ ] 2. Plant equipment and system capacity no greater than needed to meet loads
-Exception: Standby equipment automatically off when primary system is operating
-Exception:Multiple units controlled to sequence operation as a function of load
C 3 3. Minimum one temperature control device per system
[ ] 4. Minimum one humidity control device per installed humidification/dehumidification system
[ ] 5. Thermostatic controls must have 5 deg.F deadband
-Exception:Thermostats requiring manual changeover between heating and cooling
[ ] 6. Automatic Controls: Setback to 55 deg.F(heat)and 85 deg.F(cool);7-day clock,2-hour occupant
override, 10-hour backup
-Exception:Continuously operating zones
-Exception:2 kW demand or less,submit calculations
[ ] 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow>3,000 cfm
[ ] 8. Outside-air source for ventilation;system capable of reducing OSA to required minimum
[ ] 9. R-5 supply and return air duct insulation in unconditioned spaces
R-8 supply and return air duct insulation outside the building
R-8 insulation between ducts and the building exterior when ducts are part of a building assembly
-Exception:Ducts located within equipment
-Exception:Ducts with interior and exterior temperature difference not exceeding 15 deg.F.
[ ] 10. Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts;UL 181A or 181B tapes
and mastics
[ ] 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
[ ] 12. Operation and maintenance manual provided to building owner
[ ] 13. Balancing devices provided in accordance with 603.15 of Mechanical Code for New York State
[ ] 14. Newly purchased service water heating equipment will meet the efficiency requirements
[ ] 15. Water heater temperature controls: 110 deg.F for dwelling units or 90 deg.F for other occupancies
Requirements Specific To: HVAC System 2
[ ] 1. Equipment minimum efficiency: Duct Furnace(Gas): 80%Ec
2. Minimum one temperature control device per zone
3. Equipment minimum efficiency: Rooftop Package Unit: 9.2 EER,9.4 IPLV
4. Discharge dampers prohibited with fan motors>25 hp
5. Integrated air economizer required
6. Systems serving more than one zone must be VAV systems
7. Controls capable of resetting supply air temp(SAT)by 25%of SAT-room temp difference
8. Fan motor demand<=50%design kW at 50%design flow-calculations required
Requirements Specific To: Water Heating I
1. Heat traps in inlet/outlet fittings
2. 1/2-in. insulation on 8 ft of inlet/outlet piping if no integral heat traps
Section 5: Requirements Description
The following section provides a more detailed explanation of the requirements listed in Section 4.
Generic Requirements: Must be met by all systems to which the requirement is applicable
1. Design heating and cooling loads for.the building must be determined using procedures equivalent to those in
Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation
procedure.
2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece
of equipment providing both heating and cooling must satisfy this provision for one function with the capacity
for the other function as small as possible,within available equipment options.
-Exception: The equipment and/or system capacity may be greater than calculated loads for standby
purposes.Standby equipment must be automatically controlled to be off when the primary equipment and/or
system is operating.
-Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated
load are allowed if they are provided with controls to sequence operation of the units as the load increases or
decreases.
3. Each heating or cooling system serving a single zone must have its own temperature control device.
4. Each humidification system must have its own humidity control device.
5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degree F deadband(a
range of temperature where no heating or cooling is provided).
-Exception: Deadband capability is not required if the thermostat does not have automatic changeover
capability between heating and cooling.
6. The system or zone control must be a programmable thermostat or other automatic control meeting the
following criteria:a) capable of setting back temperature to 55 degree F during heating and setting up to 85
degree F during coolingb) capable of automatically setting back or shutting down systems during unoccupied
hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up
capable of maintaining programmed settings for at least 10 hours without power.
-Exception:A setback or shutoff control is not required on thermostats that control systems serving areas that
operate continuously.
-Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW
(6,826 Btu/h)or less.
7. Outdoor-air supply systems with design airflow rates>3,000 cfrn of outdoor air and all exhaust systems must
have dampers that are automatically closed while the equipment is not operating.
8. The system must supply outside ventilation air as required by Chapter 4 of the Mechanical Code for New York
State.If the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels,
the system must be capable of reducing outdoor-air flow to the minimum required levels.
9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in
unconditioned spaces(spaces neither heated nor cooled)must be insulated with a minimum of R-5.
Unconditioned spaces include attics,crawl spaces,unheated basements,and unheated garages.b) Supply and
return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c)
When ducts are located within exterior components(e.g.,floors or roofs),minimum R-8 insulation is required
only between the duct and the building exterior.
-Exception: Duct insulation is not required on ducts located within equipment.
-Exception: Duct insulation is not required when the design temperature difference between the interior and
exterior of the duct or plenum does not exceed 15 degree F.
10. All joints,longitudinal and transverse seams,and connections in ductwork must be securely sealed using
weldments;mechanical fasteners with seals,gaskets,or mastics;mesh and mastic sealing systems;or tapes.
Tapes and mastics must be listed and labeled in accordance with UL 18 IA or UL 18 113.
11. Mechanical fasteners and seals,mastics,or gaskets must be used when connecting ducts to fans and other air
distribution equipment,including multiple-zone terminal units.
12. Operation and maintenance documentation must be provided to the owner that includes at least the following
information:a) equipment capacity(input and output)and required maintenance actionsb) equipment operation
and maintenance manualsc) HVAC system control maintenance and calibration information, including wiring
diagrams,schematics,and control sequence descriptions;desired or field-determined set points must be
permanently recorded on control drawings,at control devices,or,for digital control systems,in programming
commentsd) complete narrative of how each system is intended to operate.
13. Each supply air outlet or diffuser and each zone terminal device(such as VAV or mixing box)must have its
own balancing device.Acceptable balancing devices include adjustable dampers located within the ductwork,
terminal devices,and supply air diffusers.
14. Service water heating equipment must meet minimum Federal efficiency requirements included in the National
Appliance Energy Conservation Act and the Energy Policy Act of 1992,which meet or exceed New York State
Energy Conservation Code. New service water heating equipment can be assumed to meet these requirements.
15. Water-heating equipment must be provided with controls that allow the user to set the water temperature to 110
'F for dwelling units and 90'F for other occupancies.Controls must limit output temperatures of lavatories in
public facility restrooms to 110'F.
Requirements Specific To:HVAC System 2
1. The specified heating and/or cooling equipment is covered by the New York State Energy Conservation Code
and must meet the following minimum efficiency: Duct Furnace(Gas): 80%Ec
2. Each zone of a multiple-zone system must have its own temperature control device.
3. The specified heating and/or cooling equipment is covered by New York State Energy Conservation Code and
must meet the following minimum efficiency: Rooftop Package Unit: 9.2 EER,9.4 IPLV
4. Fans with motors>25 hp may not be equipped with discharge dampers.
5. An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate.
An integrated economizer allows simultaneous operation of outdoor-air and mechanical cooling.
6. Systems serving multiple thermostatic control zones must be variable-flow systems. Zone terminal controls
must reduce the flow of primary supply air before reheating,recooling,or mixing air streams.
7. Multiple-zone systems must include controls capable of resetting the supply air temperature by at least 25%of
the difference between the design supply air temperature and the design room temperature.
8. Fans over 25 hp on a variable-flow system are specified to include flow controls that limit fan power
consumption to 50%of the design power consumption at 50%of the design airflow rate.Manufacturer's
literature and other supporting documentation must be submitted with permit application.
Requirements Specific To: Water Heating 1
1. Heat traps are required on noncirculating water heating systems on both inlet and outlet connections. Heat traps
may be purchased or field-fabricated by creating a loop or inverted U-shaped arrangement on the inlet and
outlet pipes.
2. Pipe insulation for the specified noncirculating service hot water system is required for all piping in the
following categories:a)the first 8 ft of outlet piping from any constant-temperature,noncirculating storage
systemb)the inlet piping between the storage tank and a heat trap in a noncirculating storage system.Pipe
insulation must be at least 1/2 in.and have a conductivity no>0.28 Btu•in/(h•ft2•°F).
Section 6: Compliance Statement
The proposed mechanical design represented in this document is consistent with the building plans,specifications
and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the Proposed New York State Energy Conservation Construction Code requirements in
COMcheck-EZ Version 2.3 Release 1.
The design professional shall provide to the code enforcement official a written certification that the required
HVAC tests,system balancing,etc.,have been performed and the system is operating as designed. The design
professional shall retain copies of the test reports to be provided to the code enforcement official,if requested.
Principal Mechanical Designer-Name Signature Date
Commercial Final Inspection-Report
Office No.: (518)761-8256 Date Inspection refqut re 1 ed:
Queensbury Building&Code Enforcement Arrive: a p Depart:
742 Bay Road,Queensbury,NY 12804 Inspector's Initials
NAME: PERMIT# Z-LN—'\7
LOCATION: DATE: VZ-—�—
COMMENTS:
Y N NA
Chimney "B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 711/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if re
uired
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp.110-Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stocicroom/Storage/Receiving/Shipping Room(2 hr.), I V2doors
> 10%> 1000 sq.ft.
3/411our Corridor Doors&Closers
Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft,Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot S!gnage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening System and Signage Assembly Space
Final Electrical 4/1
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 201 wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
Town of Queensbury
Fire marshal's Office
742 Bay Road
Queensbury, NY 12804 Fax{518) 745-4437
Phoney(518)761-8205
Fire Marshal's Inspection Report
Request � SCHEDULE
Received: Permit# -- i INSPECTION®N. �E
Name: `- nAMYTIME
APPROVED COMMENTS
m!A YES NO
ExITS
AISLE WIDTHS
EXIT SIGNS—NORMAL l
- BATTERY
EMERGENCY LIGHTING
FIRE EXTINGUISHERS
FIRE ALARM SYSTEM
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION SYSTEM
HOOD INSTALLATION
INTERIOR FINISHES r" {
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO HEATINGcn��
UNITS
CLEARANCE TO ELECTRICAL
REQUIRED SIGNAGE f C� {� yk-
EMERGENCY PLAN
MAXIMUM OCCUPANCY SIGN
CHIMNEY
MASONRY ROUGH IN
FINAL
CHIMNEY
FACTORY BUILT ROUGH IN
FINAL �� --
WOOD
STOVE' ROUGH IN
. FINAL
VENTER GAS
APPLIANCE ROUGH IN
FINAL
FIREPLACE
MASONRY RcaU+ H IN OK THIS l�ATE OR CLNOT ty8�
FINAL � _
FIREPLACE
FACTORY BUILT ROUGH III! _ I PECTED BY
FINAL
CoMr3EV/CliRis.Inn►e Ian/LETTERS20011FIREMARSRALINSPeCTIONREPOR 11 22�W q OCCUPANT COPY
WHITE—BUILDING DEPARTMENT COPY
Town of Queensbury
Fire Marshal's Office
742 Bay Road
Queensbury: NY 12804
Phone (518)7 1-8205 Fax(518) '745-4497
Fire Marshal's Inspectlon Report
Request SCHEDULE
Received: Permit# INSPECTION ON:
Nam e: '� I J AM ANYTIME
Location:.
APPROVED
N/A YES NO COMMENTS
EXITS
AISLE WIDTHS
EXIT SIGNS--NORMAL
- BATTERY
EMERGENCY LIGHTING
CRE EXTINGUISHERS
FIRE ALARM SYSTEM
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION SYSTEM
HOOD INSTALLATION
INTERIOR FINISHES _
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO HEATING
UNITS _
CLEARANCE TO ELECTRICAL.
REQUIRED SIGNAGE
EMERGENCY PLAN
MAXIMUM OCCUPANCY SIG
CHIMNEY
MASONRY ROUGH IN
FINAL
CHIMNEY
FACTORY BUILT ROUGH IN
FINAL
WOOD
STOVE' ROUGH IN
FINAL
VENTED GAS
APPLIANCE ROUGH IN
FINAL
FIREPLACE
MASONRY ROUGH IN OK THIS DATE 0 CO N CT�OK
FINAL
FIREPLACE
FACTORY BUILT" ROUGH IN INSPECT EY
FINAL
COMDEVICHRISJIWORDILETTER820O11FIREMARSHALINSPECTIONREPORT/1022001
WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY
ro x x x ro c� n ro ;� w ro x n ro n w ro H d r z
H w r x x H w` w a z 0 x 0 r z0 0 � � �
a z z �' H w l w p 0 a C 0 ' r a 0 C 0 ro a n H .
a N d a a n r M M n M z 0 H H M ro [a M n w
0 r r H w H N H x P 0 n w P H H H �
ro n n n 0 cn C1 U z a 0 X H p N N Z H z w z 0 W w
w to r H 0 0' 0 M 0 0 a 0 0 0 z a 0 ro 0 z !,
0 C ro ro ro > 0 0 0 © C w � z cn
q H _ n
k n z z m 0
n H ro C r n H z cn H a m n
ro H n n H 0 H p 0 [ p m , > H 'lz
Or � � � a r ax roz n [ � z �
0zrxx � 0rc 0 rv� r wa x �
0 H n w N cn ro N G ni C
t� z to ro �] a w H H a )0 w
ro Gi H ro n H H G C r 0 z k� C:- Z.._
n r z r 0 w r c c�� ro 0
y t� Q z H x 0 " HH
nz `� � izo
w � uA0c
N ro I z �; J
w ►� m � 0 00 [N0z
0
z z ►� H038 �' yd10
c 0
14
"0 z
0 0a
r
i
Commercial Final Inspection Deport
Office No.: (518)761-8256 Date Inspection re t ec ' e :
Queensbury Building&Code Enforcement Arrive:2°-bp p Depart: a m
742 Bay Road,Queensbury,NY 12804 Inspector's Initi s:
NAME: PE
LOCATION: AT
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roaf Cam lete -16
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 1111
Vestibules For Exit doors>3000 s . ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if re uircd
Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18")Above Grade
Floor Bathroom Watertight/Other Floors Oka
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stoclaoom/Storage/Receiving/Shipping Room(2 hr.), 1 'lz doors
> 10%> 1000 s .ft.
'K Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in.,Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening System and Signa e Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20'/Driveable Surface 20'wide
Okay To Issue Temp.or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&,Codes\Commercial Final Inspection Report.doc
Town of Queensbury
Fire Marshal's Office
742 Say Road
Queensbury, NY 12804
Phone (518)761-8205 Fax(518) 745-4437
t
Fire Marshal's Insnect on Report
W-9 I t.
Request SCHEDULE
Received: Permit# SCHEDULE /
ON:
E
Name: AM Pll ANYTIM
Location: sc� e)CL A-)-ODROVED I�J
N/A YES NO COMMENTS
AISEXITSLE WIDTHS X Z—
y --- —,`'j 4
EXIT SIGNS-NOTTERY RMAL
- BA ')4'
EMERGENCY LIGHTING D$4
FIRE EXTINGUISHERS I '\> Wov\lli
FIRE ALARM SYSTEM x
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION SYSTEM
HOOD INSTALLATION
INTERIOR FINISHES
STORAGE
COMPRESSED GAS Y, I
CLEARANCE TO SPRINKLERS
CLEARANCE TO HEATING y S t 6
UNITS
CLEARANCE TO ELECTRICAL— X
REQUIRED SIGNAGE (Jo
EMERGENCY PLAN
MAXIMUM OCCUPANCY SIGN
CHIMNEY C2 0 0
MASONRY ROUGHIN
FINAL
CHIMNEY
FACTORY BUILT ROUGH IN
FINAL
WOOD
STOVE' ROUGH IN
FINAL
VENTED GAS �V �� � \' 1 �)gj(>
APPLIANCE ROUGH IN
FINAL
FIREPLACE
MASONRY ROUGH IN OK THIS DAT OK IF OR CO D�TO K
FINAL
FIREPLACE
FACTORY BUILT. ROUGHIN INSPECTED BY
FINAL
COMDEV/CHRISJNVORDILE ERS20ol/FIREMARSHALINSPECTIONREPORT11022001 -OCCUPANT COPY
WHITE-BUILDING DEPARTMENT COPY YELLOW
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date In pection re t received:
Queensbury Building&Code Enforcement Arrive: �-V a ep rt:
742 Bay Road, Queensbury,NY 12804 Inspector's Initia s
NAME: PERMIT#: � C 1
LOCATION: INSPECT ON: ^— ~
TYPE OF STRUCTURE: `"
Y N N/A
raining COMMENTS
�
Jack Studs/Ireadiers V�/
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:1SueHemingway\Building.Codes.Inspection.FORMSIFraming Firestopping Inspection Report.doc January 28,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received;
Queensbury Building&Code Enforcement Arrive: a ep
742 Bay Road,Queensbury,NY 12804 Inspector's Initi s:
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
PVC: R-1,R-2,R-3,R-4 Drain Vents Y N N/A
Cast Iron,Copper Drain/Vent Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft.above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper, CPVC,Pex One&Two Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
L:\PamW\Whiting\Rough Plumbing Insulation Report.doc
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection re quest received:i,2/AO 3
Queensbury Building&Code Enforcement Arrive: 7., D ' a
742 Bay Road, Queensbury,NY 12804 Inspector's Init
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMMENTS
(�—Framing
1W) .VK_ I
Jack Studs/Headers
COMMENTS
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LAS ueHemingway\B ui Iding.Codes.Inspection.FORNISTrarni ng Firestopping Inspection Report.doc January 28,2003
Rough Plumbing/ Insulation Inspection Report
Office No. (518)761-8256 Date Inspection re ue ceived�— /0
Queensbury Building&Code Enforcement Arrive: 1, M
742 Bay Road,Queensbury,NY 12804 Inspector's Ini
3 C'�1 �6v
NAME: 45�qaA---) PERNHT M I
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper Drain/Vent Comm.
Plumbing V Vents in Place
V/ Rough Plum Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water
Top—per Co j=ercial
ex e&Two Fan-Li
Water Su
ly
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent (>,IF- Vj UJD(JV--
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
L:\PamW\Whiting\Rough Plumbing Insulation Report.doc
Foundation Inspection Report
Office No. (518)761-8256 Date Ins ection re ue ece e
Queensbury Building&Code Enforcement Arrive: Depart:
742 Bay Rd., Queensbury,NY 12804 Inspector's Ini
NAME: PERMIT
a —8 A
LOCATION: INSPECT ON:
TYPE OF STRUCTURE_
Comments
Y N N/A
Footings
Piers
onolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
einforcement in Place r-
Foundation Dampproofmg
Foundation/Waterproofing
Type of Dampproofmg/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbin nder Slab
PVC ����, opper
Fours ionInsulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
Ao
Framing / Firestopping Inspection Report �1
,Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: -1 a D art- am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initi
NAME: 1'A ED fZ1, PERMIT#:
LOCATION; INSPECT ON: a
TYPE OF STRUCTURE: -L_. to y A-
Y N N/A COMMENTS
Framing
Jack Studs/Headers
Bracing/Bridging
Joist hangers I
Jack Posts/Main Beams
Exterior sheeting nailed properly ���17(--�j fi OEJ -z>v-- �
12"O.C.
Headroom 6 ft. 8 in. r
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft.floor trusses
Anchor Bolts 6 ft.or less on center
Ice and snow shield 24 inches from wall
Fire separation I,2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation.
House side ''/x inch or 5/8 inch Type X
Garage side 5/8'inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Septic Inspection Report
Office No. (5 18)761-825 6 Date Inspection reque rqceiy�d
Queensbury Building&Code Enforcement Arrive: a P art: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Init.-
NAME PERMIT NO.:
LOCATION: INSPECT ON:
RECHECK:
Comments and/or diagram
Soil Type: Sand/Loam/Clay
Type of Water: Municipal/Well Water
Waterline separation distance
Well separation dis nce�
Other wells: I ft.
Absorption Field: T6tal en
Length of each trench ft.
Depth of trenches ft.
Size of Stone
Seepage Pits: Numb&
Size: x
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box
Distribution Box to Field Pit
Opening Sealed: Y/NI Partial
Location/Separations
Foundation to tank ft.
Foundation to absorption
Separation of Pits
Conforms as per Plot Plan Y N A,61
Location of System on Property:
Front Rear Left Side Right Side
Middle Front Middle Rear
System Use Status:
Approved
Partial Approved and needs to be re-inspected,please call the Building&Codes Office
Disapproved
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection re ue eceive-d-
Queensbury Building&Code Enforcement Arrive:W,co a JZ� a
742 Bay Road, Queensbury,NY 12804 Inspector's Ini i
NAME: C 13 ap, V !7 : ZL)07-�R I
PERMIT#
LOCATION: _ Z6,6--R 1:4 - R-MIIA INSPECT ON: 1 -13-03
TYPE OF STRUCTURE:
Y N X/A
Framing
COMMENTS
Jack Studs Headers
Bracing Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting naillCe properly >6
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or in re
Headroom 6 ft.8 in.'
Notches/Holes/Bearing ails
Metal Strapping for Notches o Plate k kJ
I V2(w) 16 gauge(8) 16D na each side
Draft stopping 1,000 sq. ltflo r trusses
Anchor Bolts 6 ft.or less on ce ter
Ice and snow shield 24 inches fr,in wall
Fire separation 1,2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity 'kin. I
Garage Fire Separation
House side V2inch or 5/8 i4h Type X
Garage side 5/8 inch Tye X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above below grade
5.0 sf grade
CyENERAL INSPECT`ION REPORT
(-518 )761-8256
Town of Queensbury
Dept.of Community Development Date inspection request received:
Building&Code Enforcement
742 Bay Road
Queensbury,NY 12804 Arrive I-If am/pm Depart_am/pm
Inspector's Initials
NAME: (19 5,11 PERMIT 4
LOCATION: DATE:
TYPE OF STRUCTURE:
RECHECK
N/A.YESAO COMMENTS
Footing V.
Monolithic Pour Fo C
Reinlorcement,in PI�or I
The contract is r e 1pvo nms for
providing protection from freezing
for 48 hours folio i th placement
of the concrete.
Materials for this purpo e n site
Foundatio a
Reinforcement in ace
Foundation/Dampproofin
Backfill Approval
Plumbing Under Slab
Plumbing VentfVents in Place
Rough Plumbing
Heating Rough In
Insulation
Foundation Walls Interior -R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent Attic Vent
Frami
Jack Studs/Headers
Bracing/Bridging-
Joist Hangers__
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping_
Office Use
.GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time:
Dept. of Community Development Request received. l �f Meet:
Building& Code Enforcement At time:
742 Bay Road Queensbury, NY 12804 ARRIVE�1,d am/pm: DEPART am/pm Notes-
(518) 761-8256 Inspector's Initials
NAME: PERMIT
LOCATION: INSPECT ON(date):
TYPE OF STRUCTURE. &J
RECHECK
N/A YES i NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
`Foundation/W allpour
Reinforcement in Place
Foundation/Dampproofing_
Backfill Approval
Plumbing Under Stab
Plumbing Vent/Vents in Place
Rough Plurnbing__
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
. unheated spaces R-
PY
R-
P Attic Vent
Framing-> JJf/ , /1,/C
Sack StudslHeaders
Bracing/Bridgmig-
Joist Hangers-
Jack Posts/Main Beam,
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Spaled
Fire Wall 2&4.hour--
Firesto i
pping-
L-.\SueHemiiigway'Ouilding.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe
Office Use
.GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time:
Dept. of Community Developmeni Request received: Meet:
Building& Code Enforcement At time:
742 Bay Road s:
. , In
Queensburj,, NY 12804 ARRIVE am/pm: DE A
(518) 761-825d Inspector's Initia
NAME: PERMIT#
LOCATION: INSPECT ON(date): kill! 2
TYPE OF STRUCTURE:
RECHECK
NIA YES NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
'Materials for this purpose on site
-FoundationVallpour .7"
Reinforcement in Place
Foundation/Dampproofing___
Backfill Approval
)KTIumbing Under Slab
Plumbing Vent/Vents in Place--
#ough Plumbing_
neating Rough-In_
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
. unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
AirInfiltration Barrier
Fire Separation 1,2,3,hoiu
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping_
L.\SueHemiiigwayl@uilding.Codes.Inspection.FORMS\GENERAT,INSPECTION REPORT.doe
office use
GENERAL INSPE rION REPORT spector:
A
Ready at tirnel�ct ,--,
Town of Queensbuiy
Dept of Community Development Request received.
Meet:
Building& Code Enforcement At time:
742 Bay Road Notes:
Queensbu6,, NY 12804 ARRIV4-:'i'C-0 a Tz�k>mlpm
spec
tor:
M e t,
e .
tim
e:L
t Notes.
(518) 761-825d Inspector's Initi s
NAME: PERMIT ff
LOCATION: INSPECT ON(date): A-Voo-
TYPE OF STRUCTURE:
RECHECK
N/A i YE NO COMMENTS
Footings/Piers �=Y-s t
Monolithic Pour Form
cement in Place d�
V
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
Foundation/Wallpour
Reinforcement in Place
Foundation/Dampproofing_ 7Z
Backfill Approval
Plumbing Under S
Plumbing Vent/Vents in Place
Rough Plumbing_
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping mi
. unheated spaces R-
Proper Vent,Attic Vent
Framing__
Jack Studs/Headers
Bracing/Bridging--
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier.
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4-hour_
Firestoppmg_
L:\S-ueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doe
Office Use
�` r - `.? �.b--„-_mot/��,Y.:'r, °'i,.=• ��
.GENERA SPECTION REPORT Inspector:
Ready at time:.
Town of Queensbury
Dept. of Community Development .Request received.- U�-- Meet:
Building chi Code Enforcement At time:
742 Bay Road
Queensbuq, AT 12804 ARRIVE�am/ RT)ZL am Notes:
(518) 761-825b Inspector's Initi
NAME: - C �r�q!I c� PERMIT## vCl%U 47
LOCATION: INSPECT ON(date): 3-
TYPE OF STRUCTURE: l A/Zw ( ��
RECHECK
N/A YES NO COMMENTS
ootin Ze 4���� � •
Monolithic Pour Form
Reinforcement in Place �L-
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
'Materials for this purpose on siteT
Foundation/Wallpour_
Reinforcement in Place
F undation/Dampproofing
ackfi1l Approval
lumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing IN t t:�) C�vzx-'v- F11_
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,41our
Firestopping
L:LSueHemingway\Building.Codes.Inspection.FORMS\GENERAI,INSPECTION REPORT.doc
C7� Offike Use
.GENERAL INSPECTION REPORT Inspector:
Ready at time:
Town of Queensbuty
Dept. of Community Development Request received: Meet:
Building& Code Enforcement At time:
742 Bay Road A Notes:
e Us
e
Queensbui-ji, AT 12804 ARRI4
A PA CA, am
(518) 761-8256 Inspector's jIniti
NAME. cs PERMIT#?�}�2iY I
LOCATION: INSPECT ON(date):
f
TYPE OF STRUCTURE. C- CO-
RECHECK
N/A YES NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
Foundation/Wallpour
Reinforcement in Place
Foundation/Dampproofing_
Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing_
Heating Rou
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
. unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridgmig-
Joist Hangers�._
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Scaled
Fire Wall 2,3,4 hour
Firestoppin
L.\SueHemiiigway\Building,Codes.Inspection.FORMS\GEtl,'ERAL INSPECTION REPORT.doc
Office
.GENERAL INSPECTION REPORT Inspector: Use
Town of Queensbury Ready at time:
De ived:
Dept. of Community Development Request rece Meet:
Building& Code Enforcement At time:
742 Bay Road
4 Notes:
Queensbury, NY 12804 ARRIVE amlpm: DEPART
(518) 761-8256 Inspector's Initials
NAME: PERMIT#
LOCATION: 0,., INSPECT ON(date):
TYPE OF STRUCTURE:
RECHECK
N/A YES i NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
'Materials for this purpose on site
Toundation/Wallpour
Reinforcement in Place
#oundation/Dampproofing_
nackfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing
Heating Rough-In
1-Y su ion
V_Uoutdation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
. unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridging_
Joist Hangers
Jack Posts/Main Beani
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4-hour
Firestopping
L:\SueHemiiigway\Building.Codes.Inspectio.i.FORMS\GENERAT,INSPECTION REPORT-doe
COMMONWEALTH ELECTRICAL INSPECTION SERVICE, INC.
Main Office 176 Doe Run Road - Manheim, PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Perrnit No.iilllllpili BHIIIi flfflnill{BBfffl`r' iN 0 8 2 17 9 Cut-in Card No 1�u
;}}}}}IflNiiifi}YIiIYI/illllll 111
ownerIllllil}IIIIli}li}llliiRl{iiffiHil{1}!}Ri}}llll/2b
}Iilllillgiffflliiifl}1}}IIIBfflffiiiflifiliiiiiff!lfifiNtffliffi111}RliIINi!!{{IH HIiiR{/fjJffH{ff/RflFRlNIUlR{{I
Locationoff 4 .....ffflffiiflllflfififff•;BBii ilifll111}}I}lffi ifiRi}iffffllli/f}Nflf{
f
Installation Consisting f... {iif /MIl1{i1�RRRiIMRR MIR ♦,fill}{f!*FRfflffiiHf��flNHffffl fifulfffffifl}fl}f#if NRMilllfff fib�i}I}fi}INl1iM}Rfl{
� /j(■+
Bilqfi{ff Illf llifllfiBfltlBBiiffiiffiiiilf 1 II11 1 f4�RNifR{lRiNfRffiiflil111HiH111f11111 fi1i414f1f {ilfflfftfifffiffiff1fillilNl!}fB1fiifilf}Ei1}RIYIIlfliff N4}}1 06111
e (f
i ffifilfflBf lfflBffflBRBfff ffiffiffi/flff/l};B}ff IliBBfiBff Bftiflffffaii lf}if{IHI!!lRfiRR11liftillR{I{pRfillYlll Ili iii iflElBf��NfiRBilifff!}f lfi FfilBiiilffflffif Bfff RifififflRl
InstalledBy/111}}IllfffillffNlfillB/ilfffBf#H dill/}flfflBlffffii!!lffiii}ff};}!1{111141i1111f14f lMM Lich Nos i!!1!lf11{fii11liiifif;ilRiillffYllNiifii1f11fi1
S ,
The conditions following governed the issuance of this certificate, and any certificate previously issued i,
cancelled:
This certificate only covers the electrical equipment and installation conditions as of date, Upon th(
introduction of additional equipment or alterations, application shall be promptly rude for inspection,
Inspectors of this Company shall have the privilege of making ' ections at any time, and if it
rules are violated, the Company shall have the right t re ol�e this c rtif catel
Date,,,, i111►fi/IMfllBill{iBiiffffif llfffitffffNRYI{ INSPECTOR
1}fill lRiiiglRlflfNi ifff Yil}I{RR{{R{aliRR lluaRliaiaal}illif Rl lllufllffasia{1f N11}
MAMhAM u UD 11 1 V i
GENEA4L INSPECTION REPORT
(-518 ) 761-8256
Town of Queensbury
Dept of Community Development Date inspection request received:
Building&Code Enforcement
742 Bay Road
Queensbury,NY 12804 Arrive-?�3f;ulvm Depart �P-m
Inspector's Initialsiv—
NAME: PERMIT# 02f-/ Vi
LOCATION: DATE:
TYPE OF STRUCTURE:
RECHECK
N/A.YES X- O COMMENTS
Footin 'ers
o ithic Pour Form �6
Reinforcement in Place
The contractor is responsible for
providing protection from freezing /V
for 48 hours following the placement
of the concrete.
Materials for this purpose on site A
Foundation/Wallpour�__
Reinforcement in Place
Foundation/Dampproofing—
Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing—
Heating Rough-In,_
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent a
Framm�,.
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping
7 i` Offwe Use
���
GENERAL INSPECTION REPORT Inspector:
YOU
Town of Queensbury Ready at time4. A
Dept. of Community Development Request received. tG ^b Z Meet:
Building& Code Enforcement At time: /a-M
742 Bay Road
Queensbury, NY 12804 ARRIY�' a / DE AR "�, pIn Notes:
(518) 761-8256 Inspector's Initi is
NAME: PERMIT# ,7-96 2,r—' [��
LOCATION: _ _ INSPECT ON(date):
TYPE OF STRUCTURE:
RECHECK
N/A YES NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
aterials for this purpose on site
oundation/Wallpour
Reinforcement in Place
Foundation/Dampproofing
Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing
Heating Rough-In
Insulation °' - _ li� o..
Foundation Walls Interior R- l
Foundation Walls Exterior R-
Floors R-
Walls It-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridging
Joist Hangers _
Jack Posts/Main Beam
Air Infiltration Barrier _
Fire Separation 1,2,3,hour �.
Penetration Sealed
Fire Wall 2,3,4-hour
Firestopping
L:\SueHemingway\Building.Codes.inspection.FORMS\GENERAL INSPECTION REPORT.doc
Office Use
.GENERAL INSPECTION REPORT Inspectors- __.
Town of Queensbury Ready at time gjQ
Dept. of Community Development Request received: I Meet:
Building& Code Enforcement At time: 4,50—Z-
742 Bay Road Queensbury, NY 12804 ARRIVE 1'.11T?a, EPART am pm Notes:]
(518) 761-8256 Inspector's Initials
NAME: Clk 6cAA-d PERMIT _,0 P9,=
1-1
LOCATION: ed, INSPECT ON(date):
TYPE OF STRUCTURE:
RECHECK
N/A YES NO COMMENTS
k Q
otings/Piers o onlithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of th&concrete.
Materials for this purpose on site
FoundationVallpour
Reinforcement in Place
Foundation/Dampproofing_
Backfill.Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
. unheated spaces R-
Proper Vent,Attic Vent
Framing__
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation t,2,3,hour
Penetration Sealed
Fire Walt 2,3,4 hour
L:\SueHemiiigway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT-doe
Offke Use
-GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time..
Dept of Community Development Request received. Meet:
Use
Building& Code Enforcement At time:
742 Bay Road
Queensbut3,, AT 12804 ARRIVEART Notes:
(518) 761-8256 Inspector's Initia
NAME: PERMIT#
LOCATION: INSPECT ON(date): >
a .
TYPE OF STRUCTURE:
RECHECK
N/A YE/1 NO COMMENTS
ootin s ier-
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection fi-om freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
Foundation/Wallpour
Reinforcement in Place
Foundation/D ampproofing
Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing-_
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Coiling R-
Duct work or piping in
. unheated spaces R-
Proper Vent,Attic Vent
Framing_ ____
Jack Studs/Headers---
BracingfBridgmig-
Joist Hangers
Jack Posts/Main Beam.
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping
L:\SueHemingway\Building.Codes.Insl)cction.FORMS%GENERAL INSPECTION REPORT.doc
Office Use
GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time:
Dept. of Community Development Request received: Meet:
Building& Code Enforcement At time: I
742 Bay Road otes:
III
A
Queensbury, NY 12804 ARRIVE tUh am P T an 6p
el
(518) 761-8256 Inspector's Initia s
P It
NAME: C, PERMIT# '7 7
LOCATION: fj INSPECT ON(date): A1, 10
. t
TYPE OF STRUCTURE: C P--V—m VPL
RECHECK
N/A YES i NO COMMENTS
Footings/Piers
Monolithic Pour Form.
Reinforcement in Place
The contractor is responsible for NIL/
providing protection from freezing
for 48 hours following the placement
of c
\/IMatenals for this propose on site �;
Foundatio
Reinforcement in Place
Foundation/Dampproofmg_
ackfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
ough Plumbing
eating Rough-In
' Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Coiling R-
Duct work or piping in
. unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air InfiltratioirBarrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping_
L:\SueHemingway'@uilding.Codes.Inspection.FORMS\GENIERAL INSPECTION REPORT-do-C
From: Dave Hatin
To: Tom Center
Date: 10/11/02 3:04PM
Subject: CR Bard inspection schedule
Inspections required;
1. rebar irisp of footings prior to any pours
2. rebar insp of walls be four any pours
3. underslab plumbing before'any pours
4. underslab insulation be four any pours
5.steel framing and certification of steel erection by
engineer
6. insulation in walls before covering
7. plumbing above slab be four any covering
8.firewall insp
9.final insp
10. sprinkler insp
You can call for partial inspections if needed. Please try to give 24 hour notice.
CC* Joel Clugstone; John O'Brien
Office Use
GENERAL INSPECTION REPORT Inspector:
To-wn of Queensbury Ready at time:
Dept. of Community Development Request received: Meet:
Building& Code Enforcement At time:
742 Bay Road
Queensbury, IVY 12804 ARRIVE 100 am/pm: DEPART am/pm Notes:
(518) 761-8256 Inspector's Initials
'NAME: PERMIT#
LOCATION: INSPECT ON(date): Of- 2,o 0
TYPE OF STRUCTURE:
RECHECK
N/A YES NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing 41,9. toe, de4A
for 48 hours following the placement UU
of the concrete.
Materials for this purpose on site
Foundation/Wallpour
Reinforcement in Place
Foundation/Dampproofmg
Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing__
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/BridgingJoist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping_
L:\SueHemingwayNJ3uilding.Codes.Inspection.FORMS\GENF,RAL INSPECTION REPORT.doc