2002-908 TORN OF OUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
CEIRT
IFICATE OF OCCUPANCY
Permit Number: P20020908 Date Issued: Thursday, October 28,2004
This is to certify that work requested to be done as shown by Permit Number P20020908
has been completed.
Tax Map Number: 523400-309-017-0001-015-002-0000
Location: 399A BIG BAY Rd
Owner: JOSEPH&DEBRA GROSS
Applicant: JOSEPH&DEBRA GROSS
This structure may be occupied as a:
By Order of Town Board
Commercial Alteration TOWN OF QUEENSBURY
Director of Building&Code Enforcement
TOWN 'OF QUEENSBURY
742 Bay Road;Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20020908 Application Number: A20020908
Tax Map No: 523400-309-017-0001-015-002-0000
Permission is hereby granted to: J0SFPH&DFBRAGR0SS
For property located at: 399A BIG BAY Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JOSEPH &DEBRA GROSS Commercial Alteration $2,000.00
61 PALMER Dr Total Value $2'000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name Address Electrical Inspection Agency
Plans&Specifications
2002-908
Interior commercial alterations,3,200 sq ft,per plot plan and specifications.
$384.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, October 07,2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o hu October 07,2004
SIGNED BY :7V/I ZT�� —for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No. 2-3
Q
No inspection will be made until applicant has received a Fee Paid $js lG�Z"1=00
valid building.permit. All applicants' spaces on this Roe.Fee Paid $
application must be completed and must appear on the Reviewed By:
application form: E C E I V E
Applicant: a E- T—a.S�a - Owner: -_=SAM
Address: A �A2j VUS Address: OCT 2 5 2002
ov-4E5 N TOWN-OF QUEENSBURY
Phone#( } - a Phone#(_} - BUILDING AND CODE
Email Address: Email Address:
Property Location: Lot Number: J House Number r✓_
Subdivision Name: Tax Map Number:
❑ New Building: residence J commercial Estimated Market Value of Construction: $
❑ Addition: residence/ commercial If an Addition,what will use of new addition be?
Alteration: residence/ commerci
C1 No change to exterior size: residence/com'1
❑ Other work(describe )
Check OccupancyInformation I"Floor 2nd Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
❑ Single family dwelling
❑ Two family dwelling
❑ Townhouse
❑ Multifamily dwelling
#of units
❑ . Office
❑ Mercantile
❑ Manufacturing
❑ 1 car detached garage
❑ 2 car detached garage
❑ 3 car detached garage
❑ 1 car attached garage
❑ .2 car attached garage
❑ 3 car attached garage
❑ Storage building-
commercial
❑ Storage building-
residential
4- Other i Q K w.
What is the proposed height of the structure feet inches
Will any second-hand or ungraded lumber be used? If so,for what?
Type of Heating System: electric/ oil / gas J wood /forced hot ajr/ baseboard/othet:
Number of Fireplaces to be installed Number of Woodstoves to be installed
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address Phone Number
Builder 6 L,tJ
Plumber
Mason
Electrician
Declaiation: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate of Complianc@ being issued,as requested by the Zoning
Administrator or Director of Building and Codes;an As Built Survev by a licensed surveyor;drawn to,scale,showing actual
location of allaew construction.
Signature: 77JP-.� owner,owner's agent,architect,contractor
xi
C�
Permit Number
Envelope Compliance Certificate Checked By/Date �
New York State Energy Conservation Construction Code - �
COMcheck EZ Software Version 2.4 Release 2a
Data filename: C:\Program Files\Check\COMcheck-EZ\Saturn of the Adirondacks.cck NA}�
22003
Section 1: Project Information �OWN BUILD�QUFE�SBU
Project Name: Saturn of the Adirondacks AND CODE Y
Designer/Contractor: Townsend Architects
Document Author: Michael Dobereiner,R.A:;
Section 2: General Information
Building Location(for weather data): Albany,New York
Climate Zone: 14a
Heating Degree Days(base 65 degrees F): 6894
Cooling Degree Days(base 65 degrees F): 523 '
Activity Type(s) Floor Area
Retail Sales,Wholesale Showroom 4036
Industrial Work,<20 ft Ceiling Height 11639
Project Description(check one):
New Construction _Addition _Alteration _Unconditioned Shell(File Affidavit)
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Air Leakage,Component Certification,and Vapor Retarder Requirements
[ ] 1 1. All joints and penetrations are caulked,gasketed,weather-stripped,or otherwise"sealed.
[ ] ) 2. Windows,doors,and skylights certified as meeting leakage requirements.
[ ] ( 3. Component R-values&U-factors labeled as certified.
[ ] ( 4. Fireplaces installed with tight fitting non-combustible fireplace doors.
[ ] ( 5. Dampers integral to the building envelope are equipped with motorized dampers.
[ ] 1 6. Cargo doors and loading dock doors are weather sealed.
[ ] ( 7. Recessed lighting fixtures are sealed or gasketed.
[ ] 8. Vapor retarder installed.
S i '
Climate-Specific Requirements
Gross Cavity Cont. Proposed Budget
Component Name/Description Area R-Value R Value U-Factor U-Factor
Roof 1:Metal Roof with Thermal Blocks 15675 19.0 20.0 0.029 0.054
Exterior Wall 1:Metal Frame, 16"o.c. 14000 19.0 0.0 0.114 0.079
Window 1:Metal Frame,Double Pane with Low-E
Clear,SHGC 0.87 1196 --- --- 0.250 0.547
Door 1: Solid 75 --- --- 0.200 0.127
Door 2:Glass,Clear,SHGC 0.54 446 --- --- 0.250 0.547
Door 3:Overhead 720 --- --- 0.200 0.127
(a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements.
Envelope PASSES: Design 3%better than code
Section 4: Compliance Statement
The proposed envelope design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application. The proposed envelope system has been designed to meet
the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 2a.
When a Registered Design Professional has stamped and signed s page,the are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans o _ ar in compliance with this Code.
Principal Envelope Designer-Name ature Date
Permit Number
Lighting and Power Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
COMcheck-EZ Software Version,2.4 Release 2a
Data filename:C:\Program.Files\Check\COMcheck-EZ\Satum of the Adirondacks.eck
Section 1: Project Information
Project Name: Saturn of the Adirondacks
Designer/Contractor: Townsend Architects
Document Author: Michael Dobereiner,R.A.
Section 2: General Information
Building Use Description by: Activity Type
Activity Type(s) Floor Area
Retail Sales,Wholesale Showroom 4036
Industrial Work,<20 ft Ceiling Height 11639
Project Description(check one):
New Construction —Addition Alteration Unconditioned Shell(File Affidavit)
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Interior Lighting
1. Total actual watts must be less than or equal to total allowed watts
Allowed Watts Actual Watts Complies(Y/N)
32918 26033 YES
Exterior Lighting
2. Type(s)of exterior lighting sources:
_Fluorescent —Metal Halide —High-Pr.Sodium
Exceptions:
Specialized signal,directional,and marker lighting;lighting highlighting exterior features of
historic buildings;advertising signage;safety or security lighting;low-voltage landscape lighting.
Controls,Switching,and Wiring
3. Master switch at entry to hotel/motel guest room.
1 4. Individual dwelling units-separately metered.
5. Minimum of two switches,dimmer,or occupancy sensor in each space.
Exceptions:
Only one himinaire in space;
Security lighting,24 hour lighting;
The area is a corridor,storage,restroon,4 retail sales area or lobby.
6. Automatic I lighting"shutoff
"shutoff control-in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.ft.
7. Photocell/astronomidal time switch'on exterior lights.
Exceptions: Areas requiring lighting during daylight hours
8. Tandem wired one-lamp and three-lamp ballasted luminaires.
Exceptions:
Electronic high-frequency ballasted luminaires not on same switch
[ ] ( 9. Transformers meet minimum efficiencies listed in Table 805.6.1 or 805.6.2.
Section 4: Compliance Statement
The proposed lighting design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application. The proposed lighting system has been designed to meet
the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 2a.
When a Registered Design Professional has stamped.and signed this page,the are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or in compliance with this Code.
Pkincipal Lighting Designer-Name a Date
Lighting Application Worksheet
New York State Energy Conservation Construction Code
COMcheck-EZ Software Version 2.4 Release 2a
Section 1: Allowed Lighting Power Calculation
A B C D
Total
Floor Allowed Allowed
Area Watts Watts
Area Category (ft2)(watts/ft2) (B x Q
Retail Sales,Wholesale Showroom 4036 2.1 8476
Industrial Work,<20 ft Ceiling Height 11639 2.1 24442
Total Allowed Watts-- 32918
Section 2: Actual Lighting Power Calculation
A B C D E F
Fixture Fixture Description/ Lamps/ #of Fixture
ID Lamp Description/Wattage Per Lamy/Ballast Fixture Fixtures Watt. (D x E)
S20 2x4 deep cell parabolic 48"T8 32W/Electronic 3 41 96 3936
S22 2x4 troffer/48"i8 32W/Electronic 3 2 96 192
S23 pendant bench light/48"T8 32W/Electronic 2 8 64 512
$24 8'pendant light/48"T8 32W/Electronic 4 16 128 2048
S25 4'pendant fixtures/48"T8 32W/Electronic 2 5 64 320
S28 4'under counter/48"T8 32W/Electronic 1 1 32 32
S29 4'pendant fixture/48"T8 32W/Electronic 2 2 64 128
S1 pendant truss system/Metal Halide 1 OOW Electronic 8 1 800 800
S2 semi-recessed system/Metal Halide 70W Electronic 6 1 420 420
S3 track system/Metal Halide 100W/Electronic 8 3 800 2400
S6 industrial light/Metal Halide 250W/Electronic 1 6 250 1500
S7 industrial light/Metal Halide 400W/Electronic 1 19 400 7600
S9 exterior surface mount/Metal Halide 250W/Electronic 1 17 250 4250
Sil showroom pendant lights/Metal Halide 175W/Electronic 1 7 175 1225
S14 showroom pendant light/Metal Halide 50W/Electronic 1 2 50 100
S30 recessed downlight Other/Electronic 1 19 30 570
Total Actual Watts= 26033
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies.
Total Allowed Watts= 32918
Total Actual Wafts= 26033
Project Compliance= 6885
Lighting PASSES: Design 21%better than code
r
Permit Number
Mechanical Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
COMcheck-EZ Software Version 2.4 Release 2a
Data filename: C:\Program Files\Check\COMcheck-EZ\Satum of the Adirondacks.cck
Section 1: Project Information
Project Name: Saturn of the Adirondacks
Designer/Contractor: Townsend Architects
Document Author: Michael Dobereiner,R.A.
Section 2: General Information
Building Location(for weather data): Albany,New York
Climate Zone: 14a
Heating Degree Days(base 65 degrees F): 6894
Cooling Degree Days(base 65 degrees F): 523
Project Description(check one):
_New Construction _Addition _Alteration Unconditioned Shell(File Affidavit)
Section 3: Mechanical Systems List
uanti System Type&Description
1 HVAC System 1: Heating:Central Furnace,Gas,Heating Capacity Unknown/Cooling:Packaged
Terminal Unit,Capacity 15000 Btu/h,Air-Cooled Condenser/Single Zone
1 Water Heating 1: Service Water Heater
Section 4: Requirements Checklist
Bldg.
Dept.
Use
Requirements Specific To:HVAC System 1
[ ] 1. Equipment minimum efficiency:
Packaged Terminal DX Unit: 9.3 EER
[ ] ( 2. Newly purchased cooling equipment meets the cooling efficiency requirements
Requirements Specific To:Water Heating 1
[ ] 1. Heat traps in inlet/outlet fittings
[ ] 2. 1/2-in.insulation on 8 ft'of inlet/outlet piping if no integral heat traps
j Generic Requirements: Must be met by all systems to which the requirement is applicable
[ ] ( 1. Load calculations per 1997 ASA AE Fundamentals
[ ] ( 2. Plant equipment and system capacity no greater than needed to meet loads
-Exception: Standby equipment automatically off when primary system is operating
-Exception:Multiple units controlled to sequence operation as a function of load
[ ] 3. Minimum one temperature control device per system
[ ] 4. Minimum one humidity control device per installed humidification/dehumidification system
[ ] ( 5. Thermostatic controls has 5 deg.F deadband
-Exception:Thermostats requiring manual changeover between heating and cooling
[ ] ( 6. Automatic Controls: Setback to 55 deg.F(heat)and 85 deg.F(cool);7-day clock,
2-hour.occupant override, 10-hour backup
-Exception:Continuously operating zones
-Exception:2 kW demand or less,'submit calculations
[ ] 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow>3,000 cfm
[ } ( 8. Outside-air source for ventilation;system capable of reducing OSA to required minimum
[ ] j 9. R-5 supply and return air duct insulation in unconditioned spaces
R-8 supply and return air duct insulation outside the building
R-8 insulation between ducts and the building exterior when ducts are part of a building assembly
-Exception:Ducts located within equipment
-Exception:Ducts with interior and exterior temperature difference not exceeding 15 deg.F.
[ ] 10. Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts;
UL 181A or 181B tapes and mastics
[ ] 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
[ ] ( 12. Operation and maintenance manual provided to building owner
[ ] } 13. Balancing devices provided in accordance with 603.15 of Mechanical Code for New York State
[ ] 14. Newly purchased service water heating equipment meets the efficiency requirements
[ ] ( 15. Water heater temperature controls: 110 deg.F for dwelling units or 90 deg.F
E for other occupancies
[ ] ( 16. Stair and elevator shaft vents are equipped with motorized dampers
[ ] S 17. Exhaust air heat recovery included for systems 5,000 cf n or greater with
more than 70%outside air fraction or specifically exempted
[ ] 18. Kitchen hoods>5,000 cfm provided with 50%makeup air that is uncooled and heated to
no more than 60 deg.F unless specifically exempted
[ ] ( 19. Buildings with fume hood systems must have variable air volume hood design,
exhaust heat recovery,or seprate makeup air supply meeting the following:
a)75%make up air quantity,and/or
i b)within 2°F of room temperature and/or
c)no humidification
d)no simultaneous heating and cooling
Section 5: Compliance Statement
The proposed mechanical design represented in this document is consistent with the building plans,specifications
and other calculations submitted with this permit application. The proposed mechanical systems have been designed'
to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4
Release 2a.
The design professional shall provide to the code enforcement official a written certification that the required HVAC
tests,system balancing,etc.,have been performed and the system is operating as designed. The design professional
shall retain copies of the test reports to be provided to the code enforcement official,if requested.When a Registered
Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,
and professional judgment,such plans or specifications are in co m s Code.
qr M�;
o t + 5• I •�'3►
rincipal Mechanical Nesignei-M me Si a Date
Mechanical Requirements Description
New York State Energy Conservation Construction Code
COMcheck-EZ Software Version 2.4 Release 2a
Data filename:C:\Program Files\Check\COMcheck-EZ\Satum of the Adirondacks.cck
The following list provides more detailed description of the requirements in Section 4 of the Mechancal Compliance
Certificate.
Requirements Specific To:HVAC System 1
1. The specified heating and/or cooling equipment is covered by the New York State Energy Conservation Code
and must meet the following minimum efficiency: Packaged Terminal DX Unit: 9.3 EER
2. The specified cooling equipment is covered by Federal minimum efficiency requirements.New equipment of
this type can be assumed to meet or exceed New York State Energy Conservation Code requirements for
equipment efficiency.
Requirements Specific To:Water Heating 1
1. Heat traps are required on noncirculating water heating systems on both inlet and outlet connections. Heat traps
may be purchased or field-fabricated by creating a loop or inverted U-shaped arrangement on the inlet and outlet
pipes.
2. Pipe insulation for the specified noncirculating service hot water system is required for all piping in the
following categories:a)the first 8 ft of outlet piping from any constant-temperature,noncirculating storage
systemb)the inlet piping between the storage tank and a heat trap in a noncirculating storage systemPipe
insulation must be at least 1/2 in.and have a conductivity no>0.28 Btu•in/(h•ft2•°F).
Generic Requirements: Must be met by all systems to which the requirement is applicable
1. Design heating and cooling loads for the building must be determined using procedures equivalent to those in
Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation
procedure.
2. All equipment and systems must be sized to be no greater.than needed to meet calculated loads. A single piece
of equipment providing both heating and cooling must satisfy this provision for one function with the capacity
for the other function as small as possible,within available equipment options.
-Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes.
Standby equipment must be automatically controlled to be off when the primary equipment and/or system is
operating.
-Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load
are allowed if they are provided with controls to sequence operation of the units as the load increases or
decreases.
3. Each heating or cooling system serving a single zone must have its own temperature control device.
4. Each humidification system must have its own humidity control device.
5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degree F deadband(a
range of temperature where no heating or cooling is provided).
-Exception: Deadband capability is not required if the thermostat does not have automatic changeover
capability between heating and cooling.
6. The system or zone control must be a programmable thermostat or other automatic control meeting the
following criteria:a) capable of setting back temperature to 55 degree F during heating and setting up to 85
degree F during coolingb) capable of automatically setting back or shutting down systems during unoccupied
hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up
capable of maintaining programmed settings for at least 10 hours without power.
-Exception:A setback or shutoff control is not required on thermostats that control systems serving areas that
operate continuously.
-Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW(6,826
Btu/h)or less.
7. Outdoor-air supply systems with design airflow rates>3,000 cfin of outdoor air and all exhaust systems must
have dampers that are automatically closed while the equipment is not operating.
8. The system must supply outside ventilation air as required by Chapter 4 of the Mechanical Code for New York
State.if the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels,
the system must be capable of reducing outdoor-air flow to the minimum required levels.
9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in
unconditioned spaces(spaces neither heated'nor cooled)must be insulated with a minimum of R-5.
Unconditioned spaces include attics,crawl spaces,unheated basements,and unheated garages.b) Supply and
return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When
ducts are located within exterior components(e.g.,floors or roofs),minimum R-8 insulation is required only
between the duct and the building exterior.
-Exception:'Duct insulation is not required on ducts located within equipment.
-Exception: Duct insulation is not required when the design temperature difference between the interior and
exterior of the duct or plenum does not exceed 15 degree F.
10. All joints,longitudinal and transverse seams,and connections in ductwork must be securely sealed using
weldments;mechanical fasteners with seals,gaskets,or mastics;mesh and mastic sealing systems;or tapes.
Tapes and mastics must be listed and labeled in accordance with UL 18 1A or UL 18 1B.
11. Mechanical fasteners and seals,mastics,or gaskets must be used when connecting ducts to fans and other air
distribution equipment,including multiple-zone terminal units.
12. Operation and maintenance documentation must be provided to the owner that includes at least the following
information:a) equipment capacity(*input and output)and required maintenance actionsb) equipment operation
and maintenance manualsc) HVAC system control maintenance and calibration information,including wiring
diagrams,schematics,and control sequence descriptions;des'ired or field-determined set points must be'
permanently recorded on control drawings,at control devices,or,for digital control systems,in programming
commentsd) complete narrative of how each system is intended to operate.
13. Each supply air outlet or diffuser and each zone terminal device(such as VAV or mixing box)must have its own
balancing device.Acceptable balancing devices include adjustable dampers located within the ductwork,
terminal devices,and supply air diffusers.
14. Service water heating equipment must meet minimum Federal efficiency requirements included in the National
Appliance Energy Conservation Act and the Energy Policy Act of 1992,which meet or exceed New York State
Energy Conservation Code. New service water heating equipment can be assumed to meet these requirements.
15. Water-heating equipment must be provided with controls that allow the user to set the water temperature to 110
OF for dwelling units and 90 OF for other occupancies.Controls must limit output temperatures of lavatories in
public facility restrooms to 110 OF.
16. Stair and elevator shaft,vents must be equipped with motorized daippers capable of being.automatically closed
during normal building operation and interlocked to open as required by fire and smoke detection systems. All
gravity outdoor air supply and exhaust hoods,vents,and ventilators must be equipped with motorized dampers
that will automatically shut when the spaces served are not in use.
Exceptions:
-Gravity(non-motorized)dampers are acceptable in buildings less than three stories in height above grade.
-Ventilation systems serving unconditioned spaces.
17. Individual fan systems with a design supply air capacity of 5000 cfin or greater and minimum outside air supply
of 70%or greater of the supply air capacity must have an energy recovery system with at least a 50%
effectiveness.
Exceptions:
-Systems serving spaces that are not cooled and heated to<60 OF.
-Commercial kitchen hoods(grease)classified as Type 1 by NFPA 96
-Systems exhausting toxic,flammable,paint,or corrosive fumes or dust
If an air economizer is also required,heat recovery must be bypassed or controlled to permit air economizer
operation.
18. Individual kitchen exhaust hoods larger than 5000 efin must be provided with make-up air sized for at least 50%
of exhaust air volume that is uncooled and either unheated or heated to no more than 60 OF
Exceptions:
-Where hoods are used to exhaust ventilation air that would otherwise exfiltrate or be exhausted by other fan
systems.
-Certified grease extractor hoods that require a face velocity no>60 fpm.
19. Buildings with fume hood systems having a total exhaust rate>15,000 cfm must either have variable air volume
hood design,exhaust air heat recovery,or separate make up air supply.
Commercial Final Inspection Report n
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: Ir am/p Depart: am/pm
742 Bay oad Queensbury,NY 12804 Inspector's Initials:
NAME: _ PERMIT#: O _
LOCATION: ~ DATE:
COMMENTS:
Y N NA
Chimne /"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 s . ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Watertight/Other Floors Oka
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure I hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oi1'Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors
> 10%> 1000 s .ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
'Ceiling Fire Stopping, 3,000 s . ft. Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters,34 in., Checkout 36"
Handicapped Ram /Handrails Continuous/12 in.Beyond
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if reg.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20'wide
'Lqkaj To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
l�
' Town of Queensbu ry
Fire Marshal's Office
742 Bay Road
Queensbury, NY 12604
Phone (518)761-8205 Fax(518)745-4437
Fire Marshal's Inspection Report
Request SCHEDULE - -
Received. C� G Permit# �e INSPECTION ON-
Name:
Name: M ANYTIME
Location
AP
PROVED
N tA_ YES NO COMMENTS
EXIT ACCESS
EXIT ENCLOSURE;",
EXIT DISCHARGE:''
MAIN AISLE WIDTH'
SECONDARY AISLEWIDTH
EXIT SIGN`-NORMAL
EXIT SIGN-13ATTERY
EMERGENCY LIGHTING
FIRE EXTINGUISHER HUNG C
FIRE EXTINGUISHER v 8
INSPECTION
FIRE EXTINGUISHER HYDRO
FIRE ALARM SYSTEM VA
FIRE ALARM -FAN SHUTDOWN
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION-KITCHEN
FIRE SUPPRESSION-GAS
ISLAND
HOOD INSTALLATION
INTERIOR FINISHES
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO ELECTRICAL
ELECTRIC WIRING ENCLOSED
COMBUSTIBLE WASTE ti
VEHICLE IMPACT PROTECTION
FIRE LANE
F.D.SIGNAGE-UTILITY ROOMS
NO SMOKING SIGNS
MAXIMUM OCCUPANCY SIGN
EMERGENCY EVAC PLAN
OK THIS DATE F R CO T OK
r
ED BY
COMDEVICHRISJIWORDILETTERS20011FIREMARSHALINSPECTIONREPORT11022001
WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY
i
Commercial Final Inspection Report .
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: 4- /
NAME: C— SS PERMIT#: OF
LOCATION: DATE:
COMMENTS:
Y N NA
Chimne /"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 s .ft.
All Doors 36 in.sv/Lever Handles/Panic Hardware,if required
b j a�•� � L ° �`J
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Watertight/Other Floors Oka
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/Z doors '
> 10%> 1000 s .ft.
3/a Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ram /Handrails Continuous/12 in.Beyond
Active Listening System and Signage Assembly Space / �
c
Final Electrical r
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides b able Surface 20' wide
, Okay To Issue Temp. or KermaneDn
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doe
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date InspectigA request received:
Queensbury Building&Code Enforcement Arrive: 1/1 0 am/pm Depart: _am/pm
742 Bay Road, Queensbury,NY J2804 Inspector's Initials:
NAME: j PERMIT#:
LOCATION: DATE: /6
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location I,/
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks oll
Stair Handrail 34 in. 38 in./Step Risers 711/Treads 1111
Vestibules For Exit doors>3000 sq.ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(187)Above Grade
Floor Bathroom Watertight/Other Floors Okay -v" J
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum V
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area V
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Y2doors
> 10%> 1000 sq.ft.
1/4Hour Corridor Doors&Closers
Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire V/Z Dampers Fire Doors V
Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x,24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed Ter-
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
WC, 5j/ -k�t
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in.,Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req. V Z'
,,,
As-built Septic System Layout Required or On File V 11��
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' vide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc