Loading...
2002-908 TORN OF OUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 CEIRT IFICATE OF OCCUPANCY Permit Number: P20020908 Date Issued: Thursday, October 28,2004 This is to certify that work requested to be done as shown by Permit Number P20020908 has been completed. Tax Map Number: 523400-309-017-0001-015-002-0000 Location: 399A BIG BAY Rd Owner: JOSEPH&DEBRA GROSS Applicant: JOSEPH&DEBRA GROSS This structure may be occupied as a: By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN 'OF QUEENSBURY 742 Bay Road;Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020908 Application Number: A20020908 Tax Map No: 523400-309-017-0001-015-002-0000 Permission is hereby granted to: J0SFPH&DFBRAGR0SS For property located at: 399A BIG BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH &DEBRA GROSS Commercial Alteration $2,000.00 61 PALMER Dr Total Value $2'000.00 QUEENSBURY,NY 12804 Contractor or Builder's Name Address Electrical Inspection Agency Plans&Specifications 2002-908 Interior commercial alterations,3,200 sq ft,per plot plan and specifications. $384.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, October 07,2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o hu October 07,2004 SIGNED BY :7V/I ZT�� —for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. 2-3 Q No inspection will be made until applicant has received a Fee Paid $js lG�Z"1=00 valid building.permit. All applicants' spaces on this Roe.Fee Paid $ application must be completed and must appear on the Reviewed By: application form: E C E I V E Applicant: a E- T—a.S�a - Owner: -_=SAM Address: A �A2j VUS Address: OCT 2 5 2002 ov-4E5 N TOWN-OF QUEENSBURY Phone#( } - a Phone#(_} - BUILDING AND CODE Email Address: Email Address: Property Location: Lot Number: J House Number r✓_ Subdivision Name: Tax Map Number: ❑ New Building: residence J commercial Estimated Market Value of Construction: $ ❑ Addition: residence/ commercial If an Addition,what will use of new addition be? Alteration: residence/ commerci C1 No change to exterior size: residence/com'1 ❑ Other work(describe ) Check OccupancyInformation I"Floor 2nd Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet ❑ Single family dwelling ❑ Two family dwelling ❑ Townhouse ❑ Multifamily dwelling #of units ❑ . Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage ❑ .2 car attached garage ❑ 3 car attached garage ❑ Storage building- commercial ❑ Storage building- residential 4- Other i Q K w. What is the proposed height of the structure feet inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil / gas J wood /forced hot ajr/ baseboard/othet: Number of Fireplaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder 6 L,tJ Plumber Mason Electrician Declaiation: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Complianc@ being issued,as requested by the Zoning Administrator or Director of Building and Codes;an As Built Survev by a licensed surveyor;drawn to,scale,showing actual location of allaew construction. Signature: 77JP-.� owner,owner's agent,architect,contractor xi C� Permit Number Envelope Compliance Certificate Checked By/Date � New York State Energy Conservation Construction Code - � COMcheck EZ Software Version 2.4 Release 2a Data filename: C:\Program Files\Check\COMcheck-EZ\Saturn of the Adirondacks.cck NA}� 22003 Section 1: Project Information �OWN BUILD�QUFE�SBU Project Name: Saturn of the Adirondacks AND CODE Y Designer/Contractor: Townsend Architects Document Author: Michael Dobereiner,R.A:; Section 2: General Information Building Location(for weather data): Albany,New York Climate Zone: 14a Heating Degree Days(base 65 degrees F): 6894 Cooling Degree Days(base 65 degrees F): 523 ' Activity Type(s) Floor Area Retail Sales,Wholesale Showroom 4036 Industrial Work,<20 ft Ceiling Height 11639 Project Description(check one): New Construction _Addition _Alteration _Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Bldg. Dept. Use Air Leakage,Component Certification,and Vapor Retarder Requirements [ ] 1 1. All joints and penetrations are caulked,gasketed,weather-stripped,or otherwise"sealed. [ ] ) 2. Windows,doors,and skylights certified as meeting leakage requirements. [ ] ( 3. Component R-values&U-factors labeled as certified. [ ] ( 4. Fireplaces installed with tight fitting non-combustible fireplace doors. [ ] ( 5. Dampers integral to the building envelope are equipped with motorized dampers. [ ] 1 6. Cargo doors and loading dock doors are weather sealed. [ ] ( 7. Recessed lighting fixtures are sealed or gasketed. [ ] 8. Vapor retarder installed. S i ' Climate-Specific Requirements Gross Cavity Cont. Proposed Budget Component Name/Description Area R-Value R Value U-Factor U-Factor Roof 1:Metal Roof with Thermal Blocks 15675 19.0 20.0 0.029 0.054 Exterior Wall 1:Metal Frame, 16"o.c. 14000 19.0 0.0 0.114 0.079 Window 1:Metal Frame,Double Pane with Low-E Clear,SHGC 0.87 1196 --- --- 0.250 0.547 Door 1: Solid 75 --- --- 0.200 0.127 Door 2:Glass,Clear,SHGC 0.54 446 --- --- 0.250 0.547 Door 3:Overhead 720 --- --- 0.200 0.127 (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Envelope PASSES: Design 3%better than code Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 2a. When a Registered Design Professional has stamped and signed s page,the are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans o _ ar in compliance with this Code. Principal Envelope Designer-Name ature Date Permit Number Lighting and Power Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code COMcheck-EZ Software Version,2.4 Release 2a Data filename:C:\Program.Files\Check\COMcheck-EZ\Satum of the Adirondacks.eck Section 1: Project Information Project Name: Saturn of the Adirondacks Designer/Contractor: Townsend Architects Document Author: Michael Dobereiner,R.A. Section 2: General Information Building Use Description by: Activity Type Activity Type(s) Floor Area Retail Sales,Wholesale Showroom 4036 Industrial Work,<20 ft Ceiling Height 11639 Project Description(check one): New Construction —Addition Alteration Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Bldg. Dept. Use Interior Lighting 1. Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 32918 26033 YES Exterior Lighting 2. Type(s)of exterior lighting sources: _Fluorescent —Metal Halide —High-Pr.Sodium Exceptions: Specialized signal,directional,and marker lighting;lighting highlighting exterior features of historic buildings;advertising signage;safety or security lighting;low-voltage landscape lighting. Controls,Switching,and Wiring 3. Master switch at entry to hotel/motel guest room. 1 4. Individual dwelling units-separately metered. 5. Minimum of two switches,dimmer,or occupancy sensor in each space. Exceptions: Only one himinaire in space; Security lighting,24 hour lighting; The area is a corridor,storage,restroon,4 retail sales area or lobby. 6. Automatic I lighting"shutoff "shutoff control-in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.ft. 7. Photocell/astronomidal time switch'on exterior lights. Exceptions: Areas requiring lighting during daylight hours 8. Tandem wired one-lamp and three-lamp ballasted luminaires. Exceptions: Electronic high-frequency ballasted luminaires not on same switch [ ] ( 9. Transformers meet minimum efficiencies listed in Table 805.6.1 or 805.6.2. Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 2a. When a Registered Design Professional has stamped.and signed this page,the are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or in compliance with this Code. Pkincipal Lighting Designer-Name a Date Lighting Application Worksheet New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 2a Section 1: Allowed Lighting Power Calculation A B C D Total Floor Allowed Allowed Area Watts Watts Area Category (ft2)(watts/ft2) (B x Q Retail Sales,Wholesale Showroom 4036 2.1 8476 Industrial Work,<20 ft Ceiling Height 11639 2.1 24442 Total Allowed Watts-- 32918 Section 2: Actual Lighting Power Calculation A B C D E F Fixture Fixture Description/ Lamps/ #of Fixture ID Lamp Description/Wattage Per Lamy/Ballast Fixture Fixtures Watt. (D x E) S20 2x4 deep cell parabolic 48"T8 32W/Electronic 3 41 96 3936 S22 2x4 troffer/48"i8 32W/Electronic 3 2 96 192 S23 pendant bench light/48"T8 32W/Electronic 2 8 64 512 $24 8'pendant light/48"T8 32W/Electronic 4 16 128 2048 S25 4'pendant fixtures/48"T8 32W/Electronic 2 5 64 320 S28 4'under counter/48"T8 32W/Electronic 1 1 32 32 S29 4'pendant fixture/48"T8 32W/Electronic 2 2 64 128 S1 pendant truss system/Metal Halide 1 OOW Electronic 8 1 800 800 S2 semi-recessed system/Metal Halide 70W Electronic 6 1 420 420 S3 track system/Metal Halide 100W/Electronic 8 3 800 2400 S6 industrial light/Metal Halide 250W/Electronic 1 6 250 1500 S7 industrial light/Metal Halide 400W/Electronic 1 19 400 7600 S9 exterior surface mount/Metal Halide 250W/Electronic 1 17 250 4250 Sil showroom pendant lights/Metal Halide 175W/Electronic 1 7 175 1225 S14 showroom pendant light/Metal Halide 50W/Electronic 1 2 50 100 S30 recessed downlight Other/Electronic 1 19 30 570 Total Actual Watts= 26033 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies. Total Allowed Watts= 32918 Total Actual Wafts= 26033 Project Compliance= 6885 Lighting PASSES: Design 21%better than code r Permit Number Mechanical Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 2a Data filename: C:\Program Files\Check\COMcheck-EZ\Satum of the Adirondacks.cck Section 1: Project Information Project Name: Saturn of the Adirondacks Designer/Contractor: Townsend Architects Document Author: Michael Dobereiner,R.A. Section 2: General Information Building Location(for weather data): Albany,New York Climate Zone: 14a Heating Degree Days(base 65 degrees F): 6894 Cooling Degree Days(base 65 degrees F): 523 Project Description(check one): _New Construction _Addition _Alteration Unconditioned Shell(File Affidavit) Section 3: Mechanical Systems List uanti System Type&Description 1 HVAC System 1: Heating:Central Furnace,Gas,Heating Capacity Unknown/Cooling:Packaged Terminal Unit,Capacity 15000 Btu/h,Air-Cooled Condenser/Single Zone 1 Water Heating 1: Service Water Heater Section 4: Requirements Checklist Bldg. Dept. Use Requirements Specific To:HVAC System 1 [ ] 1. Equipment minimum efficiency: Packaged Terminal DX Unit: 9.3 EER [ ] ( 2. Newly purchased cooling equipment meets the cooling efficiency requirements Requirements Specific To:Water Heating 1 [ ] 1. Heat traps in inlet/outlet fittings [ ] 2. 1/2-in.insulation on 8 ft'of inlet/outlet piping if no integral heat traps j Generic Requirements: Must be met by all systems to which the requirement is applicable [ ] ( 1. Load calculations per 1997 ASA AE Fundamentals [ ] ( 2. Plant equipment and system capacity no greater than needed to meet loads -Exception: Standby equipment automatically off when primary system is operating -Exception:Multiple units controlled to sequence operation as a function of load [ ] 3. Minimum one temperature control device per system [ ] 4. Minimum one humidity control device per installed humidification/dehumidification system [ ] ( 5. Thermostatic controls has 5 deg.F deadband -Exception:Thermostats requiring manual changeover between heating and cooling [ ] ( 6. Automatic Controls: Setback to 55 deg.F(heat)and 85 deg.F(cool);7-day clock, 2-hour.occupant override, 10-hour backup -Exception:Continuously operating zones -Exception:2 kW demand or less,'submit calculations [ ] 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow>3,000 cfm [ } ( 8. Outside-air source for ventilation;system capable of reducing OSA to required minimum [ ] j 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly -Exception:Ducts located within equipment -Exception:Ducts with interior and exterior temperature difference not exceeding 15 deg.F. [ ] 10. Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts; UL 181A or 181B tapes and mastics [ ] 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment [ ] ( 12. Operation and maintenance manual provided to building owner [ ] } 13. Balancing devices provided in accordance with 603.15 of Mechanical Code for New York State [ ] 14. Newly purchased service water heating equipment meets the efficiency requirements [ ] ( 15. Water heater temperature controls: 110 deg.F for dwelling units or 90 deg.F E for other occupancies [ ] ( 16. Stair and elevator shaft vents are equipped with motorized dampers [ ] S 17. Exhaust air heat recovery included for systems 5,000 cf n or greater with more than 70%outside air fraction or specifically exempted [ ] 18. Kitchen hoods>5,000 cfm provided with 50%makeup air that is uncooled and heated to no more than 60 deg.F unless specifically exempted [ ] ( 19. Buildings with fume hood systems must have variable air volume hood design, exhaust heat recovery,or seprate makeup air supply meeting the following: a)75%make up air quantity,and/or i b)within 2°F of room temperature and/or c)no humidification d)no simultaneous heating and cooling Section 5: Compliance Statement The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed' to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 2a. The design professional shall provide to the code enforcement official a written certification that the required HVAC tests,system balancing,etc.,have been performed and the system is operating as designed. The design professional shall retain copies of the test reports to be provided to the code enforcement official,if requested.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief, and professional judgment,such plans or specifications are in co m s Code. qr M�; o t + 5• I •�'3► rincipal Mechanical Nesignei-M me Si a Date Mechanical Requirements Description New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 2a Data filename:C:\Program Files\Check\COMcheck-EZ\Satum of the Adirondacks.cck The following list provides more detailed description of the requirements in Section 4 of the Mechancal Compliance Certificate. Requirements Specific To:HVAC System 1 1. The specified heating and/or cooling equipment is covered by the New York State Energy Conservation Code and must meet the following minimum efficiency: Packaged Terminal DX Unit: 9.3 EER 2. The specified cooling equipment is covered by Federal minimum efficiency requirements.New equipment of this type can be assumed to meet or exceed New York State Energy Conservation Code requirements for equipment efficiency. Requirements Specific To:Water Heating 1 1. Heat traps are required on noncirculating water heating systems on both inlet and outlet connections. Heat traps may be purchased or field-fabricated by creating a loop or inverted U-shaped arrangement on the inlet and outlet pipes. 2. Pipe insulation for the specified noncirculating service hot water system is required for all piping in the following categories:a)the first 8 ft of outlet piping from any constant-temperature,noncirculating storage systemb)the inlet piping between the storage tank and a heat trap in a noncirculating storage systemPipe insulation must be at least 1/2 in.and have a conductivity no>0.28 Btu•in/(h•ft2•°F). Generic Requirements: Must be met by all systems to which the requirement is applicable 1. Design heating and cooling loads for the building must be determined using procedures equivalent to those in Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater.than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible,within available equipment options. -Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. -Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degree F deadband(a range of temperature where no heating or cooling is provided). -Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degree F during heating and setting up to 85 degree F during coolingb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power. -Exception:A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously. -Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW(6,826 Btu/h)or less. 7. Outdoor-air supply systems with design airflow rates>3,000 cfin of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 8. The system must supply outside ventilation air as required by Chapter 4 of the Mechanical Code for New York State.if the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels, the system must be capable of reducing outdoor-air flow to the minimum required levels. 9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces(spaces neither heated'nor cooled)must be insulated with a minimum of R-5. Unconditioned spaces include attics,crawl spaces,unheated basements,and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When ducts are located within exterior components(e.g.,floors or roofs),minimum R-8 insulation is required only between the duct and the building exterior. -Exception:'Duct insulation is not required on ducts located within equipment. -Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degree F. 10. All joints,longitudinal and transverse seams,and connections in ductwork must be securely sealed using weldments;mechanical fasteners with seals,gaskets,or mastics;mesh and mastic sealing systems;or tapes. Tapes and mastics must be listed and labeled in accordance with UL 18 1A or UL 18 1B. 11. Mechanical fasteners and seals,mastics,or gaskets must be used when connecting ducts to fans and other air distribution equipment,including multiple-zone terminal units. 12. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity(*input and output)and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC system control maintenance and calibration information,including wiring diagrams,schematics,and control sequence descriptions;des'ired or field-determined set points must be' permanently recorded on control drawings,at control devices,or,for digital control systems,in programming commentsd) complete narrative of how each system is intended to operate. 13. Each supply air outlet or diffuser and each zone terminal device(such as VAV or mixing box)must have its own balancing device.Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices,and supply air diffusers. 14. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy Conservation Act and the Energy Policy Act of 1992,which meet or exceed New York State Energy Conservation Code. New service water heating equipment can be assumed to meet these requirements. 15. Water-heating equipment must be provided with controls that allow the user to set the water temperature to 110 OF for dwelling units and 90 OF for other occupancies.Controls must limit output temperatures of lavatories in public facility restrooms to 110 OF. 16. Stair and elevator shaft,vents must be equipped with motorized daippers capable of being.automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods,vents,and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: -Gravity(non-motorized)dampers are acceptable in buildings less than three stories in height above grade. -Ventilation systems serving unconditioned spaces. 17. Individual fan systems with a design supply air capacity of 5000 cfin or greater and minimum outside air supply of 70%or greater of the supply air capacity must have an energy recovery system with at least a 50% effectiveness. Exceptions: -Systems serving spaces that are not cooled and heated to<60 OF. -Commercial kitchen hoods(grease)classified as Type 1 by NFPA 96 -Systems exhausting toxic,flammable,paint,or corrosive fumes or dust If an air economizer is also required,heat recovery must be bypassed or controlled to permit air economizer operation. 18. Individual kitchen exhaust hoods larger than 5000 efin must be provided with make-up air sized for at least 50% of exhaust air volume that is uncooled and either unheated or heated to no more than 60 OF Exceptions: -Where hoods are used to exhaust ventilation air that would otherwise exfiltrate or be exhausted by other fan systems. -Certified grease extractor hoods that require a face velocity no>60 fpm. 19. Buildings with fume hood systems having a total exhaust rate>15,000 cfm must either have variable air volume hood design,exhaust air heat recovery,or separate make up air supply. Commercial Final Inspection Report n Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: Ir am/p Depart: am/pm 742 Bay oad Queensbury,NY 12804 Inspector's Initials: NAME: _ PERMIT#: O _ LOCATION: ~ DATE: COMMENTS: Y N NA Chimne /"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oi1'Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors > 10%> 1000 s .ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors 'Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in., Checkout 36" Handicapped Ram /Handrails Continuous/12 in.Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if reg. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide 'Lqkaj To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc l� ' Town of Queensbu ry Fire Marshal's Office 742 Bay Road Queensbury, NY 12604 Phone (518)761-8205 Fax(518)745-4437 Fire Marshal's Inspection Report Request SCHEDULE - - Received. C� G Permit# �e INSPECTION ON- Name: Name: M ANYTIME Location AP PROVED N tA_ YES NO COMMENTS EXIT ACCESS EXIT ENCLOSURE;", EXIT DISCHARGE:'' MAIN AISLE WIDTH' SECONDARY AISLEWIDTH EXIT SIGN`-NORMAL EXIT SIGN-13ATTERY EMERGENCY LIGHTING FIRE EXTINGUISHER HUNG C FIRE EXTINGUISHER v 8 INSPECTION FIRE EXTINGUISHER HYDRO FIRE ALARM SYSTEM VA FIRE ALARM -FAN SHUTDOWN FIRE SPRINKLER SYSTEM FIRE SUPPRESSION-KITCHEN FIRE SUPPRESSION-GAS ISLAND HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE ti VEHICLE IMPACT PROTECTION FIRE LANE F.D.SIGNAGE-UTILITY ROOMS NO SMOKING SIGNS MAXIMUM OCCUPANCY SIGN EMERGENCY EVAC PLAN OK THIS DATE F R CO T OK r ED BY COMDEVICHRISJIWORDILETTERS20011FIREMARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY i Commercial Final Inspection Report . Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: 4- / NAME: C— SS PERMIT#: OF LOCATION: DATE: COMMENTS: Y N NA Chimne /"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s .ft. All Doors 36 in.sv/Lever Handles/Panic Hardware,if required b j a�•� � L ° �`J Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/Z doors ' > 10%> 1000 s .ft. 3/a Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ram /Handrails Continuous/12 in.Beyond Active Listening System and Signage Assembly Space / � c Final Electrical r Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides b able Surface 20' wide , Okay To Issue Temp. or KermaneDn Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doe Commercial Final Inspection Report Office No.: (518) 761-8256 Date InspectigA request received: Queensbury Building&Code Enforcement Arrive: 1/1 0 am/pm Depart: _am/pm 742 Bay Road, Queensbury,NY J2804 Inspector's Initials: NAME: j PERMIT#: LOCATION: DATE: /6 COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location I,/ Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks oll Stair Handrail 34 in. 38 in./Step Risers 711/Treads 1111 Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(187)Above Grade Floor Bathroom Watertight/Other Floors Okay -v" J Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum V Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area V Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 Y2doors > 10%> 1000 sq.ft. 1/4Hour Corridor Doors&Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire V/Z Dampers Fire Doors V Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x,24" Smoke Vents Or Fan, if required Elevator Operation and Signage/Shaft Sealed Ter- Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage WC, 5j/ -k�t Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. V Z' ,,, As-built Septic System Layout Required or On File V 11�� Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20' vide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc