Loading...
2002-886 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 CE RT IFICATE OF OCCUPANCY Permit Number: P20020886 Date Issued: Tuesday, May 06,,2003 This is to certify that work requested to be done as shown by Permit Number P20020886 has been completed. Tax Map Number: 523400.290-017-0001.038.000-0000 Location: 88 MASTERS COMMON NORTH Owner: MICHAELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: By Order of Town Board Garage-3 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling D tector of uiid &Code ce t TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020886 Application Number: A20020886 Tax Map No: 523400-290-017-0001-03 8-000-0000 Permission is hereby granted to: MTCHAFI,SCTROIJPI,T,CTIIF For property located at: 88 MASTERS COMMON NORTH in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. T"e of Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Garage-3 Cars Attached MALTA NY 12020 Single Family Dwelling 276,000.00 Total Value 276,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2002-886 Construction of a 3,070 sq ft single family dwelling with a 770 sq ft attached three-car garage and one fireplace per plot plan and specifications. $445.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: S etilrday,October 25,2003 (If a longer period is required,an application for an extension must be made to the code Enforc enA(3fffcer of the Town of Queensbury before the expiration date.) Dated at the ToT7n _y ,October 25,2002 SIGNED BY for the Town of Queensbury. Director of Building&Code%forcement Building Permit Application �� ����� Town of Qucensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY (518)76 I-825G 'Z-1 2002 C A permit must be obtained before beginning construction. Permit File No, — QWN Off-QUEENSBURY No inspection will be oracle until applicant has received a Fee Paid $ ., '� BUILDI IG AND CODE valid building permit. All applicants' spaces on this Rce. 1%ee Paid $_ application must be completed and must appear on the Reviewed By: �C + application form. Applicant:��{ 'i �� G�� Owner: VDF— Address: 1 Address: L/ Phone Property Location: Lot Nurn cr: I House Number /InAenL.`e 1C�1CIYl � Subdivision Name: �1 Z�n%z'� Tax Mali Number: New Building: residence /conuncrcial Estimated Market Value of Construction:$ 0Q7(.P (3CX'1) ❑ Addition: residence/ commercial If an Addition,what will use of new addition be? ❑ Alteration: residence/ commercial ❑ No change to exterior size: residence/com'l o. Other work(describe ) Check Occulmneyinfornlatiou I`+Floor 2"` Floor other Hoor 'Total Below set.fl. sq.ft. sq. U. Square Feet Single family dwelling At—�.cal ❑ . Two family dwelling ❑ Townhouse ❑ Multifamily dwelling; #of units ❑ Office ❑ Mercantile d Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage a 3 car detached garage ❑ 1 car attached garage ❑ 2 car attached garage 3 car attached garage ?� ❑ Storage building- t commercial ❑ Storage building- residential ❑ Other �� `J�, f✓ Will any second-hand or ungraded lumber be used? If so, for what? ,�, . Type of Heating System: electric/ oil /(S)wood /forced hot air/ baseboard/other: Number of Fireplaces to be installed CIRS Number of Woodstwes•to be installed . List below the person(s) responsible ror supervision of work as regards to building codes: Na me a y Address { P_llioone N`Uniber .. Plumber —Y Mason55c ElectricianG �.i/GY�iL lleclaraliort; please sign below aver you trove ctur.ti+lly read the statcnten[:.�. To(lie best of my knowledge the statements contained in this application,together with the plans and specifications submitted, are a true and complete statement ofall proposed work to be done on the described premises and(hat all provisions of the Building Cocle, the Z.oniag Ordinance and all other laws pertaining to the proposed work shall be complieel with, whcllier specified or noted, and that sucli work is authorized by the an•+ter. Further, it is understood that Ihve shall submit, prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Toning Administrator or Director of Bijilcling and Co(jes,an its Biti/t Sarver by a licensed surveyor;drawn to scale,showing actual location ol'all new c rtstructi Signature:_ + owner,owner's agent,architect,contractor TOWN OF QUEENSBURy ,7 Riclitard A.Missita HIGHWAY Highway Superintendent DE PA RTM EN Home(518),798-5127 742 Bay Road,* Queensbury,NY 12804 Michael F. Travis Deputy Highway Superintendent Offs4.Aone: (518) 761-821f (518)798-0413 -Tax. (518) 745-4466 DRIVEWAY PERMIT C VjEL) DATE: 0C, 212002 (9 TOS UVVJLA1J01N(3 FQ IJEENSS UR y APPLICANT NAME: TELEPHONE NO.: tE ADDRESS TO BE INSPECTED: Na,Mn6r RETURN ADDRESS: Applicant must show exact location and width of driveway(s).to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: )Preliminary Approval NEED: )Slight male Level with the road Deep male Size pipe to be used(if necessary) )12" )15" ( )18" ( )24" ( )36" Preliminary inspection completed by DATE Approval by Highway Supt. Deputy Supt Upon completion,please resubmit this approved permit for a final approval. STEP 2: )Final Approval Rejected DATE: Richard A. Missita,Highway Superintendent Fire Marshal's Office Town of Queensbury,742 Buy Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas'.appliances Date466r AG , 20 0_L- Permit No.Z00 4S Application is,hereby made to the Building& Codes Office for the issuance of Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances,s, regulations, and all conditions that are part of these requireihents and also will allow all inspectors to enter premises to 1jeiforin required inspections. NOTE to applicant.: .Rough-in and Final Inspections are required. -Applicant Information Fuel Burning Appliance I'nformation (circle appropriate words) Stove: wood coal pellet gas Name: a�c_� Fireplace insert,' -built: wood gasFireplace, factory Address: Fireplace, masonry: wood gas Furnace: wood gas oil, Phone: If non-masonary applicance, please provide Owner.- Manufacturer Name: Address: Model Number: Chimney Information Phone: (circle appropriate words) Masonry block brick stone Flue tile steel size: inches Exact Address: of construction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction I Installation must earn f arm to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbu' ry Handouts",regarding required inspections. Double wall Triple wall Insulated Direct venting Chimney Liner Wit-_Vw-xnm_z-th: Fire Marshal Code# Collected S Refunded Receivedfi-onz (itfairded-m):- ck(I tj 61", address: A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales DATE: White(Applicant) Green(Fire Marshal) t Yellow, (Bldg.Dept.) I Pink&Goldenrod(Cashier's Dept,) RECEIVEP OCT 2002 Permit Number TOWN OF QUEENSBURY BUILDING AND CODE MECcheck Compliance Report Checked By/Date Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lb Data filename: C:\Program Files\Check\MECcheck\88MastersN.cck TITLE:Hastings Model(std.-revised family room) COUNTY: Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE:Detached I or 2 Family HEATING TYPE:Non-Electric DATE: 10/17/02 DATE OF PLANS:October 16,2002 PROJECT INFORMATION: 88 Masters Common North COMPANY INFORMATION: The Michaels Grop 10 Blacksmith Dr. Malta,NY 12020 COMPLIANCE:Passes Maximum UA=612 Your Home=594 2.9%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 1874 30.0 0.0 60 2nd fir walls:Wood Frame, 16" o.c. 1636 19.0 0.0 85 MBath-u:Wood Frame,Double Pane with Low-E 48 0.340 16 MBed-t:Wood Frame,Double Pane with Low-E 21 0.340 7 MBed-u:Wood Frame,Double Pane with Low-E 24 0.340 8 MBed-c:Wood Frame,Double Pane with Low-E 17 0.340 6 Bed#4-c:Wood Frame,Double Pane with Low-E 17 0.340 6 Loft-s:Wood Frame,Double Pane with Low-E 17 0.340 6 Foyer-q:Wood Frame,Double Pane with Low-E 12 0.340 4 Bed#2-p:Wood Frame,Double Pane with Low-E 25 0.340 9 Bed#3-f.- Wood Frame,Double Pane with Low-E 31 0.340 11 Ist fir walls: Wood Frame, 16"o.c. 2106 19.0 0.0 98 Family-k:Wood Frame,Double Pane with Low-E 28 0.340 10 Family-1:Wood Frame,Double Pane with Low-E 8 0.340 3 Family-h:Wood Frame,Double Pane with Low-E 24 0.340 8 Family-j: Wood Frame,Double Pane with Low-E 6 0.340 2 w ^ t Family-m: Wood Frame,Double Pane with Low-E 14 0.340 5 Brkfst-b:Wood Frame,Double Pane with Low-E 22 0.340 7 Brkfst-e:Wood Frame,Double Pane with Low-E 33 0.340 11 Brkfst-d:Wood Frame,Double Pane with Low-E 17 0.340 6 Kitchen-g: Wood Frame,Double Pane with Low-E 22 0.340 7 Dining-f Wood Frame,Double Pane with Low-E 31 0.340 11 Dining-c:Wood Frame,Double Pane with Low-E 31 0.340 11 Living-c:Wood Frame,Double Pane with Low-E 62 0.340 21 Study-a:Wood Frame,Double Pane with Low-E 24 0.340 8 Study-c:Wood Frame,Double Pane with Law-E 15 0.340 5 Door-Foyer-1: Solid 20 0.230 5 Dr-Foyer-Sidelight: Glass 16 0.350 6 Dr-Family:Glass 64 0.350 22 Dr-Mud: Solid 20 0.230 5 Dr-Nook:Glass 20 0.350 7 Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul 1566 0.0 11.0 101 Window 27:Vinyl Frame,Double Pane 11. 0.560 6 Floor over Garage: All-Wood Joist/Truss,Over Unconditioned Space 240 19.0 0.0 11 Furnace 1:Forced Hot Air,80 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the Proposed New York State Energy Conservation Construction Code requirements. Builder/Designer Date 1 MECcheck Inspection Checklist Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release I DATE: 10/17/02 TITLE:Hastings Model(std.-revised family room) Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. I Above-Grade Walls: [ ] I 1. 2nd flr walls: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] I 2. lst fir walls: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] I 1. Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. I Windows: [ ] I 1. MBath-u:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] I 2. MBed-t:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] I 3. MBed-u:Wood Frame,Double Pane with Law-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] I 4.. MBed-c:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] I 5. Bed#4-c:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] I 6. Loft-s:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] I 7. Foyer-q:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: fi #Panes Frame Type Thermal Break?[ ] Yes[ ]No Comments: [ ] ( 8. Bed#2-p: Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] ( 9. Bed#3-f Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes{ ]No Comments: [ ] 10. Family-k: Wood Frame,Double Pane with Law-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 11. Family-1:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?{ ]Yes[ ]No Comments: [ ] 12. Family-h:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 13. Family j:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?{ ]Yes[ ]No Comments: [ ] 14. Family-m:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?{ ]Yes [ ]No Comments: [ ] j 15. Brkfst-b:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without Iabeled U-factors,describe features: j #Panes Frame Type Thermal Break?{ ]Yes[ ]No Comments: { ] ( 16. Brkfst-e:Wood Frame,Double Pane with Law-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: { ] { 17. Brkfst-d:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: 1 #Panes Frame Type Thermal Break?[ ]Yes{ ]No 1 Comments: [ ] 18. Kitchen-g:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: E #Panes Frame Type Thermal Break?{ ]Yes[ ]No Comments: [ ] 19. Dining-f:Wood Frame,Double Pane with Low-E,U-factor:0.340 ( For windows without Iabeled U-factors,describe features: #Panes Frame Type Thermal Break?{ ]Yes[ ]No Comments: [ ] ( 20. Dining-c:Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 21. Living-c:Wood Frame,Double Pane with Low-E,U-factor:0.340 # For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: 22. Study-a:'Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: A Panes Frame Type Thermal Break? Yes No Comments: 1 23. Study-c:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows.without labeled U-factors,describe features: #Panes . Frame Type— Thermal Break? Yes No Comments: 24. Window 27:Vinyl Frame,Double Pane,U-factor: 0.560 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments- Doors: 1. Door-Foyer-1: Solid,U-factor:0.230 Comments: 2. Dr-Foyer-Sidelight: Glass,U-factor:0.350 4 Panes Frame Type Thermal Break? Yes No Comments: 3. Dr-Family:Glass,U-factor: 0.350 #Panes Frame Type Thermal Break? Yes No Comments: 4. Dr-Mud: Solid,U-factor: 0.230 Comments: 5. Dr-Nook:Glass,U-factor: 0.350 #Panes Frame Type Thermal Break? Yes No Comments: Floors: 1. Floor over Garage:All-Wood JoisttTruss,Over Unconditioned Space, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: 1. Furnace 1:Forced Hot Air, 80 AFUE or higher Make and Model Number Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-11. Return ducts in unconditioned attics or outside the building must be insulated to R-6. i [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] ( Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] ( All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] ( Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. 3 Temperature Controls: [ ] Each dwelling unit has at Iesat one thermostat capable of automatically adjusting the space .temperature set point of the largest zone. E Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] j Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or [ the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the Ievels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. # Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the levels in Table 2. M � fi Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(Q Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100430 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACP1pes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Tvves Range F 2"Runouts 1"and Less 1.25 to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) Y RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement ! Dept,of Community Development Arrive• am/pm Depart at rn Town of Queensbury Inspector's Initial _ 742 Bay Road Queensbury,New York,12804 / NAME 04 1}'C-GS 6W, PERMIT 4 LOCATION wmn C DATE 2r 6-!> TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney Heightl"B"Vent/Direct Vent Location Fresh Air Intake Plumb Vent through roof Roof Complete Exterior Finish Complete laterior/Exterior Railings 30"to 36" Exterior Handrails,balconies,landing 18 in.or more Interior Handrails stairs both sides 3 or more risers Grade 21D/o away from foundation 8"clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Furnace shut-off within 30 feet or within line of site shut-off at entrance to furnace area 2Ic: nace/Hot Water Heater operating Relief Valve(s)installed Headroom,6 ft.6 in.on stairs Basement stairs,6 ft.4 in. Handrail exterior stairs both sides more than 3 risers. Interior privacy/ttun/doors/main entrance 36" Floor Finish Bathroom/Kitchen watertight Interior Handrails Balconies/Landing 18 in.or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans lumbing fixtures Foundation insulation 3/4 hour fire door/door closer Garage fueproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical Site PlanNariance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif,of Compliance) Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certf:of Occupancy) RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building& Code Enforcement Dept.of Community Development Arrive am/pm Depart am/pm Town of Queensbury Inspector's Initials 742 Bay Road Queensbury,New York,12804 7Qf NAME PERMIT# LOCATION DATE TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney HeightPT"Vent/Direct Vent Location Fresh Air Intake < ( e< Plumb Vent through roof Roof Complete Exterior Finish Complete Interior/Exterior Railings 30"to 36" Exterior Handrails,balconies,landing 18 in.or more Interior Handrails stairs both sides 3 or more risers Grade 2%away from foundation 8"clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operatin Relief Valve(s)installed Headroom,6 ft.6 in.on stairs Basement stairs,6 ft.4 in. Handrail exterior stairs both sides more than 3 risers. Interior privacy/trim/doors/main entrance 36" Floor Finish Bathroom/Kitclien watertight Interior Handrails Balconies/Landing 18 in.or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire door/door closer Garage fireproofing ng Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room- / glazing 18"or less from floor Electrical 1anJVanance required Sun re Plat Plan As Built Septic System layout required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) MAP REFERENCE: MASTER'S COMMON NORTH DATED: AUGUST 26, 1987 BY: VAN DUSEN & STEVES FILED: MARCH 10, 1988 DRAWER 17 FOLDER 1 LOT 23 LOT 24 MASTERS COMMON NORTH 41 .0 APR 8TOWN Na ov Q EENSBVRY Duse.Z2w• StevesbKr Land Surveyors 169 Haviland Road Queensbury, New York 12804 (518) 792-8474 New York Lie. No. 50135 �L" �8` NR/Ie01 W RMN 7= SUN-MM 1% W Mt r W VM omit mua" LW asrs afar 9E W ML tr e$ super 111� ■111 AN 014ML CF M IAIO I!/tYEIl01!! M�.E�mW,`�. * =='M NACIIIED M a.wr 1l.,T Ml !/REY l PANED N Awo ISURx MiM '�[ 0 n n`IMWPW � wo NW&I M a" con"Mi as sru " afr r of M 0~ 10 ft mu: Im MI " �„� as � ""° Map of a Survey made for MICHAEL & KELLI LEE Town of Queensbury, Warren County, New York llate= APRiL z9, 2003 Scale 1'=31Y S-1 LEE wrc. No. MCN-34 NO. DATE DESCR/P710N Residential Final Inspection Office No. (518)761-8256 Date Inspection request received. I Queensbury Building&Code Enforcement Arrive: am/pmo Opart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: k3lp NAME: V(), 0 LCs-Y7,A-x,,D PERMIT LOCATION: G DATE: TYPE OF STRUCTURR Comments Y "N N/A ChimneyHt./"B"Vent/DirectVent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Intedof/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut'-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stainvells safety glazing Interior Smoke Detectors: Every level: - / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window V/ Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches cot %hour fire door/door closer Garage fireproofing Duct work Scaled properly Attic access 30 in.x 24 in.x 30 in.(ht)In accessible area Crawl Spaces 18"x 24"apces.s, I sq. ft,-150 sq.ft.vents Building No./Ad(klss visible from road Final Electrical .WL&J 0,3 Site Plan [Variance required g— Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker ll I°7 Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupanc� Okay to issue Permanent C/0(Cert, Of Occupancy� L:\SueHeming%vay\BLtilding.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 29,2003 Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518)745-4437 Fire Marshal's Inspection Report Request &F Z — SCHEDULE 'T-// 103 Received: Permit# INSPECTION ON: Name: Ne�'-'5 Como AM PM ANYTIME Location: ccft . APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING , UNITS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGH IN FINAL,*, CHIMNEY FACTORY BUILT. RO KIN .,/FINAL WOOD STOVE ROUGH IN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN n NOT OK FINAL OK THIS ATE OK FOR C FIREPLACE FACTORY BUILT ROUGH IN INSPECTED BY FINAL COMDEV/CHPJSJIWORD/LETTERS200I/FIREMARSHALINSPECTION'q EP IRTI 1022001 YELLOW-OCCUPANT COPY WHITE-BUILDING DEPARTMENT COPY Foundation Inspection Report Office No. (5 18)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: o, PERMIT#: (n--2—r�T LOCATION:L' SPECT ON: 2, 12,0 o IN TYPE OF STRU4C : Comments y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. A Foundation/Wallpour Reinforcement in Place PAUndation Dampproofing VFoundation/Waterproofing j CAK- Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC-/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. GENERAL INSPECTION REPORT (-518 )761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: -C.rad Building&Code Enforcement \1147 742 Bay Road ? 56 Queensbury,NY 12804 Arrive am/pm Dep, Initials Inspector's I&41� NAME: l cu C, PERMIT# 02-1-90/0. _7- LOCATION: DATE: TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placemen( of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing VentfVents in Place Plumbing gh P1 bi g XeaL�ngRough-In------------I V Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- sI Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent Attic Vent Framin Jack Studs/Headers Bracing/Bridging Joist HangersL_ Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppiniz Rough Plumbing/Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pr�i� Depart:'-'-,--- am/p 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: �i � 4 d LOCATION: INSPECT ON: 3 TYPE OF STRUCTURE: Y N N/A !. PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Train and Vents 5 PSI or 10 ft. above highest -10 Connection for 15 minutes Water Supply Piping VIVA_ j c - -1 Copper Commercial 01 �l VC,Pex One&Two Family Insulatio /R idential Check/Commercial CheckT1� Proper Vent,Attic Vent ' ` Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace r Duct Work Sealed Properly COMMENTS: S,. _ �, -RAJ �-� -r-�->6-K f JAJ L:IPamW\Whiting\Rough Plumbing Insulation Report.doc Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ )epart: 6L&dmdprri 742 Bay Road, Queensbury,NY 12804 Inspector's Initials• No NAME: k!.Nk "0 PERMIT#: LOCATION: INSPECT ON: ( �* TYPE OF STRUCTURE: Y N N1A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour , ire wall 2, 3,4 hour irestoppin __-- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing/Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: At _ Queensbury Building&Code Enforcement Arrive: am/ D rt: /pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: �Ata - .. NAME: llr�1 t =� S (CIRIP, PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: _awe rr Y N /A COMMENTS FjF x - ack ds/Headers racing/Bridging yroist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center `Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fie wal 2;3;4 our �F`ir e Penetration sealed i 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / FirestoPP ing Inspection Report P P Office No. (518) 761-8256 Date Inspection request received: 1 Queensbury Building&Code Enforcement Arrive: am/pm epart:, m/ in .r 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: + � , NAME: t S PERMIT#: LOCATION: MA,6V 0 ►" INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS - sJack Studs l Headers I 115 1 � 1� �F..`C S i� %d'L"55 Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properlyIrJ 12"O.C. Headroom 6 ft. 8 in. _ Stairwells 36 in. or more -1��ZpG i'� U g S f`'� 1t C.? Headroom 6 ft. 8 in. Notches!Holes I Bearing.Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses T%L U,:;.s "C Anchor Bolts 6 $. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour l 'tW Penetration sealed i �� �ra 16 inch insulation in cavity min. Garage Fire Separation House side jl2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L;\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 / I Rough Plumbing / Insulation Inspection Report S Office No. (518)761-8256 Date Inspection request received: �, 11 1,0 3 Queensbury Building&Code Enforcement Arrive: am/pm Depart: 1 an4m 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: Gt INSPECT ON: 8 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. E14uLing entsin Place Rough Plumbi it Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft.above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Vex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: LAPamMWhiting\Rough Plumbing Insulation Report.doc Town of dueensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(5 18) 745-4437 Fire Marshal's Inspection Report Request rr,, SCHEDULE 3 Received: Permit# 101/2 INSPECTION ON: 31 lc�46 �i �vName: A ANYTIME U Location: 16- APPROVED N/A I YES NO ENTS EXITSC�-�%"� AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY M ONRY ROUGH IN z .,FINAL / CHIMNEY ROUGH IN FACTORY BUILT V� FINAL WOOD -STOVE ROUGHIN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN OK THIS A OK FOR CO NOT OK / FINAL FIREPLACE L:? - FACTORY BUILT \/ROUGH IN INSPECTED BY FINAL COMDEV/CHRISJAfVORD/LETTERS20OI/F IRE MARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE am/pm: DEPAR18 am/pm Notes: (518) 761-8256 Inspector's lnitials4k"-� NAME: CrNZ1 PERMIT# LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place oundation/Dampproofing_ ckfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing____ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppin L:\Suel4emingway\Building.Codes.Inspection.FORMS\GENERAI,INSPECTION REPORT.doc Office Use .GENERAL INSPECTION REPORT Inspector: Town of Queensbuq Ready at Dept, of Community Development Request received, Meet: Building& Code Enforcement At time: 742 Bay Road Notes: Queensbui3; NY 12804 ARRIVE am/pm: DEPARTmlpm (518) 761-8256 Inspector's Initial�a%� NAME- PERMIT# ST4 LOCATION: w1 � ca)-vi INSPECT ON(date): ///70 16 2- t TYPE OF STRUCTURE: C T > RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site -Foundation/Wallpour�_ I Reinforcement in Place Foundation/Dampproo -Ugackfill Approval 0S _7 "jPlumbing Under Slab Y Plumbing VentlVents in Place/ \ - Rough Plumbing Heating Rough-In Insulation Foundation Walls Interiol R- Foundation Walls Exterior R- Floors R- Walls It- Ceiling R- Duct work or piping in . unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping_ L.-\SueHemiiigwayTuilding.Codes.Inspecflon.FORMS\GENE-RAL INSPECTION REPORT.doc Office Use .GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time:.*., Dept. of Community Development Request received: C Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE am/pm: DEP,4R7Z am/pm Notes: (518) 761-8256 Inspector's Initials NAME: 14 PERMIT#2,b 2, (0 F ,LU LOCATION: INSPECT ON(date): M102Z- TYPE OF STRUCTURE: RECHECK N/A i YESe,1�0 COMMENTS Footings/Piers XY Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site "FoimdationfWallpour Reinforcement in Place Foundation/Darnpproofing­ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Beating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- C-eiling R- Duct work or piping in . unheated spaces R- Proper Vent,Attic Vent Framing__ Jack Studs/Headers Bracing/Bridging_ Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping_ L:\SueHemiiigway'Buildiiig.Codes-Inspection.FORMS\GENERAL INSPECTION REPORTAM Rough Plumbing l Insulation Inspection Report Office No. (518)761-8256 Date Ins.nec on request received: b" — _am/pm Queensbury Building&Code Enforcement Arrive: 18Z_ra;�P'm Depart: 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:. NAME: PERMIT ff: k LOCATION: rl INSPECT ON: Nn', TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/.Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Dfain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial �bpper,6PVC,Pex One&Two Family Xsulation/ esid tial Check/Commercial Check .0-1 -Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: �L-.\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 lwl- ��� .RECEIVED OCT 1A 2002