2002-880 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20020880 Application Number: A20020880
Tax Map No: 523400-309-007-0002-025-000-0000
Permission is hereby granted to: RFBECCA POVVFRS LINEHAN
For property located at: 48 Mallory Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: REBECCA POWERS LINEHAN Demolition
48 MALLORY Ave Total Value
QUEENSBURY,NY, 12804
Contractor or Builder's Name/Address, Electrical Inspection Agency
Plans&Specifications
2002-880
DEMOLITION of a 480 sq ft porch per plot plan and specifications.
$20.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,October 24,2,00,31T1
'A(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To Queens Thursday,October 24,2002 F
SIGNED BY
for the Town of Queensbury.
Director of Building WoNdenforcement
TOWN OF QUEENSBURY
742 Bay Road
Queensbury, N.Y. 12804-9725
Application for DEMOLITION PERMIT
Permit No. .
Instructions for completing the application Date: 19(1&1671
Fee Paid:
1. All applicable spaces are to be completed.
2. Two plot plans are to be submitted, drawn to scale, showing.
a. lot boundaries, with dimensions and adjacent roads and streets.
b. all existing structures, indicating which are to be removed. 0 C T G 20 02.
c. location of all utilities.
3. Fee submitted per current fee schedule. (
Owner of property: `�'�E l J 0 W,�-e-SProperty Location: e r f a Ycq 4-V EKU�:-
Mailing Address: 4� Wt � ( Jt w Tax Map No. section*3 d 9.Block 7"A ,Lot o?,
Person responsible for work: t l Telephone No. q 3` 'f 6
1 O-2
Mailing Address: ''` "310
Where will demolition material be disposed of? U
Is there any asbestos within building to be demolished? Yes / No_
1el 1
If YES, name of firm removing asbestos from structure, license number, and where asbestos will be disposed of-
NAME OF FIRM LICENSE NUMBER
LOCATION WHERE ASBESTOS WILL BE DISPOSED
A COPY OF ASBESTOS REMOVAL REPORT MUST BE FILED WITH THIS DEPARTMENT BEFORE DEMOLITION BEGINS.
The following building(s) located on property described above are to be removed:
Previous use of building (circle one): residence garage storage business other Of
Have all utilities been disconnected? gas , electric koE , propane , water
Size of building(s):1. ft. by ft. Location on property k R-ac O C— O US L
2. ft. by ft. Location on property
3. Number of stories:
4. Foundation type(circle one): QI cell wl s ace slab
Foundation will REMAIN BE MOVED
5. Another structure WILL WILL NOT ie— , replace this building.
NOTES:Signature of Applicant: 1 (w.QCt -5
owner,owner's agent,architect, contractor
�'�`� Queensbury Building & Code Enforcement - Residential Final Inspection
6:ffice No.(518)761-8256 Arrive: am/pm Depart: am/pm
Date Inspection request received: Inspector's Initials:
NAME: C` PERMIT#:LOCATION: DATE: q1V
TYPE OF STRUCTURE: comment
Yes Na N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails P,stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, I s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110 _
Enclosed Stairs Sheetrock Underside minimum%z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched.
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood PIain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent
L:Viuilding&Codes Forms\Building&CodesUnspection Forms\Residential Final Inspection Form_revised_100405.doc