Loading...
2002-943 TOWN- OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: a2002O943 Application Number: a2002O943 Tax Map No: 523400-296-020-0001-040-000-0000 Permission is hereby granted to: CTFONECONSTRUCTION For property located at: 4 CRONIN Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: PIRLIP &LINDA HART Storage Building 10,000.00 53 VVINCREST Dr Total Value 10,000.00 QUEENSBURY,NY 12804 Contractor or Builder's Name Address Electrical Inspection Agency Plans&Specifications 2002-943 Construction of a storage building(walk-in cooler)per plot plan and specifications. $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow 0 en ;sb ,IV 4 e...for the Town of Queensbury. SIGNED BY : Director of Building&Code Enforcement Building. Permit Application Town ofQueensbury-•Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. .Permit File No t 0' ..S No inspection will be made until applicant has received a Fee Paid valid building permit. All-applicants' spaces on this Rec:Fee Paid $. application must be completed and must appear on the -Review �� application form. Applicant: t-O r e C."t c, mac. Owner: a�rve s�" �l e sto..,, o.r " NOV I ' 2002 :. Address: Po Address: 4 13NG UEErvsauRY Phone#(5�)`l`la - '►a A Phone# Property Location: Lot Number: ! House Number Subdivision Name: Tax Map Number:a49&, =/ ❑ New Building: residence /commercial Estimated Market Value of Construction:$ ar, Addition: residence I cominerc' If an Addition,what will use of new addition be? ❑ Alteration: residence t commercial ❑ No change.to exterior size: residence/com'l ❑• Other work(describe } Check OccupancyLiformation 1` Floor 2" Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet ❑- Single family dwelling ❑ Two family dwelling ❑ Townhouse p Multifamily dwelling #of units o Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage 0 2 car detached garage ❑ 3 car detached,garage v I car attached garage ❑ 2 car attached garage ❑ 3 car attached garage - .Storage building- commercial`W ❑ Storage building- - residential C3r, Other What is the proposed height of the structure l 3 feet inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric I oil / gas I wood /forced hot air/:baseboard/other: Number of Flrent wes to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone.Number Builder C , P Plumber Mason. Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge-the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning 'Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature: owner,owner's agent,arebitec contractor FIN26�L - COMMERCIAL INSPECTION REPORT Request received: &/4/0- 1/ 7 Office Use Town of Queensbury (518) 761-8256 ARRIVE am/pm: .DEPART All IPAR �39, 742 Bay Road Ready at time: Is Queensbw4y,,"AT &I-St Inspector's Init.als 12804 1-0 Meet: NAME ��Qa� PERMIT#* 3 At time: LOCATION_:�j TYPE OF STRUCTURE <-A)a 1A INSPECT ON rate): 3 Notes: N/A ChimneyP'B"Vent/Direct Vent location l YES NO I I Plumbing Vent —/ Roof Complete COMMENTS Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks Interior/exterior balusters 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Step risers 7%in. Main door 44 in. All others 36 in. COMMENTS Lever handles Exits at grade or platform Canopy to cover req, exit doors Gas valve shut-off exposed&regulator(18 in.)above grade Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour)__ >1,000,000 BTU's(2 hour)_ Gas furnace shut off within 30 ft. or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),%hour door -F- Storage/receiving/sliipping room(2 hour), 1 V7.doors 1 Y2hour doors and closers %hour corridor doors and closers Firewalls/fire separation,2 hour,3-hour complete Fire dampers,2-hour fire wall/separation or greater Fire door/shutters 1 V2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq. ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets < Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in._ Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required_ Okay to issue TEMPORARY C/O—Certificate of Occupancy yes_ no Okay to issue PERMANENT C/O—Certificate ofOccupancy yes_ no3z Okay to issue C/C—Certificate of Compliance yes_ no Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection reque ceiv e-d-,: Queensbury Building&Code Enforcement Arrive: a pm Dep rf,' a M6,4r�jj-,, 742 Bay Road, Queensbury, NY 12804 Inspector's Initiate NAME: Re-Sk:!% Lx LC,nA PERMIT#: q1 1 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS ?Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. - Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LAS ucHemingway\B u ilding.Codes.Inspection.FORM STrarning Firestopping Inspection Report.doc January 28,2003 A T ®frke Use .,GENERAL WSPEC TION UPOR.T Inspector: .Town of Queensbury Ready at time:: �. Dept. of Community Development bequest received: .� ,� Meet: Building& Code-Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE1-"T'; /�3 7', z"":Jam�pm - otes: (518) 761-8256 Inspector's Ini 'al NAME: f Jj PERMIT# D ­7 Ai z 4 LOCATION: CkE- INSPECT ON(date): TYPE OF STRUCTURE: ��--- RECHECK N/A YE 'i NO COMMENTS Footings/P' r Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Faundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- _ Walls R- Ceiling R Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers BracingBridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation t,2,3,hour Penetration Sealed Fire Wall 2,3,4-hour Firestopping _ L:\SueHemingway\Buiiding.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc TOWN OF QUEW NSEURY I E COPY BUILDING DE PT, P�C�l Q REVIEWED BY N Obi Flash to existing roof DATE TorccoJ 1/2"OSB roof shea M rafters @ 16"OC 3.9.1/2"ML header 2x6 subfascia 4"steel column alum,fascia 3.9.1/2"ML header j� TOWN i Qi,"4Ei cKUURY EUl1,L+INC,DEPARTMENT R aired on our limited examination, EXISTING COOLER NEW WALK IN COOLER compliance with our commend shall not be construed as indicating the plsns and specif cations are in bli compliance with the rode, 4"steel column 0. ,aa p• °, ° Q. W 41 Existing grade EXISTING FOUNDATION ,° oN - 4 �' 'Q g' 4"poured concret slab 4000PSI with WWF v. ° 1,0 4' 2"Foam insulation compact soil in 8"lifts Ga ° �, 8"poured concrete wall 3500 PSI . v v °Q d n < . °• 81146"poured concrete footing 3500 PSI a, ':9 da.o 244 rebar cont. l Existing cooler vCU ou . 2 2002 � pow of I $�� DINGND C BURy I I ooE S" poured concrete wall I I p I F xIV poured concrete f ootings i I w 4" concrete slab N I � I I I I I I I i IL _— _ _ _ - - - - - _ _ _ _ _ � _ _� I I.- _ _ - _ _- -_ -_ ^ _ - _ _ _ - _ __ _ _ 11' m