2002-962 `'
} 'TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256'
CERTIFICATE OF 'OCCUPANCY
Permit Number: P20020962, Date Issued: Thursday,May 29,2003
This is to certify that work requested to be done as shown by Permit Number P20020962
has been completed.
Tax Map Number: 523400-296-008-0001.015-002-0000
Location: 39 WAVERLY Pt
Owner: MICHAELS GROUP LLC THE
Applicant: MICHAELS GROUP LLC THE
This structure may be occupied as a:
By Order of Town Board
Fireplace TOWN OF QUEENSBURY
Garage-2 Cars Attached
Townhouse
Director of Building&Code Enforcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development=Building&Codes (818) 761-8256 '
BUILDING PERMIT
Permit Number: P20020962 Application Number: A20020962
Tax Map No: 523400-296-008-0001-015-002-0000 .
Permission is hereby granted to:` MICHAELS GRCI JP LLC THE
For property located at: 39 WAVERLY PI
in the Town of Queensbury,to construct or place,
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner.Address: MICHAELS GROUP-LLC THE
10 BLACKSMITH Dr, GaraFireplace
MALTA,NY 12020-0000 Townhouse
-2 Cars Attached
. Townhouse 182;900.00
Total Value 182,900.00
Contractor or Builder's Name/Address Electrical Inspection Agency
MICHAELS GROUP
SUITE 1
10 BLACKSMITH Dr
MALTA.NY 12020
Plans&Specifications
2002-962
Construction of a 1,932 sq ft townhouse with a 483 sq ft attached two car garage and one woodstove per plot
plan and specifications.
A
$318.78 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday;November 20,2003
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.) }
Dated at the To of Q en sb d ,November.20,2002
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury—Dept of Community Development, 742 Bay Road,Queensbuty,NY
(518)761.-8256
A permit must be obtained before beginning construction: Permit File No.
No inspection will be made until applicant has received a Pee Paid $
valid building permit. All.applicants' spaces oil this Rcc, Fcc Paid $ D
application must be completed and iriust appear on the Reviewed By: No / 1 82002
application form.
Q(!E
Applicant:ITME. ""yiAS - Owner: ��� !U1
"LIVGAtVpCO
Address: - tSTYZ_�43
EF
Address: —$:a
1lC I-\ tA of. k2ciZt
Phone# (5._e) q.- _� Phone#( ) -
Property Location: ` Lot Number: House Number
Subdivision Name: -,1 C 1u Tax Map Number: —�
New Building: residence !commercial Estimated Market Value of Construction:$
❑ Addition: residence/ conu-nercial' If an Addition, what will use of new addition be?
❑ Alteration: residence/ commercial
❑ No change to exterior size: residence/coni'l
❑ Other work(describe )
Check OCcttpancylnforination 1"Floor 2'" Floor Other noor Total
13ciow sq.ft. sq.ft. sq. ft. Square Feet
❑ Single family dwelling
❑ Two family dwelling l
;W Townhouse
❑ Multifamily dwelling
#of units
❑ Office
❑ Mercantile
❑ Manufacturing
❑ I car detached garage
❑ 2 car detached garage
❑ 3 car detached garage
❑ 1 car attached garage
X2 car attached garage ���
❑ 3 car attached garage
❑ Storage building-
commercial
❑ Storage building-
residential.
❑ Other
Will any second-hand or ungraded lumber be used? 'If so, for what?
Type of-I:Ieating System: electric/ oil -/ gas wood /.forced hot air/ baseboard/other:
Number ofTirentrtces to be installed (=, Number of Jt`oodstrznes to be installed .} .
hcrson(s) jeesponsible for sul2er_vision of work as regards to building codes:
Narne Address Phone Number
' i.�ldcr �►chze'.5- `� �tSFa�.�c4��l�tt�-t�,.1�r�.a ��� c ``micas-_fc�11._.—'
Plumber { �4�1�j1d l� _ C `l�_�\ 2A-�
Mason �?t j, r�-*{ 3 C�cl�sQ �e �k-21— J93
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work sliali be complied
with, whether specified or noted,and that.such work is authorized by the owner. Further, it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate or Compliance being issued,as requested by the Zoning
Administrator or Director of Building and 'o es n As Bit ilt Survey by a licensed surveyor;drawn to scale,showing actual
location orall new c u radio -
Signature: owner,owner's agent,architect,contractor
TOWN QF`.
ENSBU
BUILDING 4&GCODESRpEPARTMENT ��1 V Fee Paid
APPLICATION FOR:. -PORCHES-DECKS- �nermit #
DOCKS & BOATHOUSES'V 7 8200,2 Est. Cost .
Tpw�OF
A PERMIT MUST BE OBTAINED BEFORE,'BEGINNING CONSTRU /NCfi' WER ALL, OF. THE FOLLOWING:-, ,
ODE.
The undersigned-- hereby applies for a :Building Permit to do the -following wor -whi'ch will be
done in accordance with the description, plans and specifications submitted, and such special-,
conditions as may be-Andicated _on the permit. TWO SETS OF STRUCTURAL PLANS SHALL BE SUBMITTED.
WITH THIS APPLICATION.
Owner. of Property:. v AtC.1r;t� -t�Y2'?.Sty
P.O.- Address- _ �O .�lzGsrRc� v�u � .l2UZS5 Phone #
Property Location . - - - "�!-� Tax Map .# :2Q
Subdivision Name (If applicable) jr-���
PERSON RESPONSIBLE-.FOR SUPERVISION OF WORK AS ,REGARDS TO.BUILDING CODES:
Name-: lY ll Address Phone#
BUILDING SPECIFICATIONS:
Type of work to .be' ,done:, Porch. Deck Dock Boathouse (Circle one)
Size of Structure 'to be built- (square. footage) gas F.
Foundation Material Width - Thickness
Depth of .Pooting,_,below grade;: .
Size of Posts or Studs: x x Long
Size of Floor Joists x x Span
Decking or Flooring Material :
How will Porch or Deck be fastened to' building?
If Roof Will Be Insta-11ed, Answer Fol'lowing.Questions:
Size of Posts orStuds: x x Long
Roof Rafters: x Spacing. 'Span
Roof Trusses (ore-engineered spacing): Span
Type of. Roof:,.- Sloped Flat Shed Other - (Circle one)
Material of Roof;:.,,
ZONING INFORMATION:
TWO PLOT PLANS MUST .BE PREPARED AND- SUBMITTED, drawn reasonably to scat-e and attached
hereto, showing clearly and• distinctly all buildings, whether existing or proposed and
indicate all setback dimensions from property lines. Show location- of water supply and
location and configuration of septic disposal area.
Size of Property: ft.. x, ft.
Existing bu-ilding(s): Size ft. x_ ft.
Size- ft. 'x ft.
Use of Existing building(s):'
oiii—jai"vpE1 o;Jr i n"G:
-Front yard ft. Rear yard. ft:
Side'yards ft: and ft.
If''on corner, setback from side street:.. ft.'
DECLARATION
To the best of my knowledge and' belief the.statements' contained in this application;
together with the plans and specifications 'submitted_, are a -true and .complete' statement
of all proposed work to be done on the described premises and that all provisions of the
Building Code, the Zoning :Ordinance, and all other law's pertaining to the proposed work
shall be complied with; whether specified or not, and that such work is authorized by the
owner.
DATE: SIGNATURE
�— Ow er, Owners Agency, Architect, Contractor
REVIEWED BY CODE ENFORCEMENT OFFICER-', DATE SIGNATURE
Fire Marshal's.ofiice Town of Queensbury,742 Bay Road, nsbury,NY
(518)761-8205 t
Application for Burning Appliances & Chimneys k1
pp V�o
applicable to solid fuel & vented gas .appliances NOV 18 2002
Date 24 t�, C Z J�t No, 8-U N 14��KSNS D -1wy ? �.._.._ I gND Cope
Application is hereby made to the Building&Codes Office for the issuance of a Building and Use
Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner
agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of
these requirements and also will allow all inspectors to enter premises to perform required inspections.
NUTS' to applicant: Rough-in and Final Inspections are required.
Applicant Information Fuel Burning Appliance Information
(circle appropriate words)
Name: MiCQS Stove: wood coal pellet gas
Fireplace insert
Address: Q l S Fireplace, factory-built: wood gas
Fireplace,.masonry: wood gas
Furnace: wood gas oil
Phone: G
If non-masonary applicance,please provide
Owner, Manufacturer Name:
-Address: .Model Number:
Chimney Information
Phone: (circle appropriate words)
Masonry block k stone
Flue tile steel ize: inches
Exact Address: 30N 1L OnGg
of construction or ins t tion Factory-Built
Manufacturer name:
Model Number:
Note: Listed By: Number:
Construction IInstallation must
con. orin to NYS Fire Prevention &Building Indicate(circle) chimney material:
Code. Consult available Town of Queensbury
Handouts regarding required inspections. Double wall / Triple wall / Insulated / Direct venting
Chimney Liner
TC0WV:1 x of Q�acie+e� sz:x-y:1V'�e�sr Y�'or,�
i
1-ire Marshal Code 9 $Collected $Ref usded Receiv c fi vm (r nded to).�
address: ^�_
A 173 3389 (190) Public Saf¢ty
A 233 2655 (230)Minor Sales
DATE:
/Y _� U V
White(Applicant) / Green(Fire Marshal) ! Yellow(Bldg.Dept.) / Pit*&Goldenrod(Cashier's Dept.)
00 ,
Mare
H IG- H W* AY
Highway Superintendent
DiapA,RT- MEN
T Home(518)798-5127
�
742 Bay Road • Queensbury,NY 12804 NOV 16IicJtael F. Travis
+Q�ce Phone: (518) 761-8211 $ zD� Deputy'HighwaySuperintendent
Pax. (518) 745-4466 TOWAI OF '(518)798-0413
BulLDI1VG AND Co p RY
DRIVEWAY PERMIT
DATE: —AC`J.1-OJ++1 �' ,
APPLICANT NAME: F..���'' I�� k� a
TELEPHONE NCI.:
ADDRESS TO BE INSPECTED:"
('��, � 2.�[6,OF-I— 5"1Z
RETURN ADDRESS:
.Applicant must show exact location and width of driveway(s)to be connected to the highwayby
placing stakes at the specified location.
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The
fcillowing action has been taken:
STEP 1: ( }Preliminary Approval
NEED: { )Slight swale
( } Level with the road
{ }Deep swale
Size pipe to be used(if necessary)
{ }12" ( )15" ( )18" { )24" ( }36"
Preliminary inspection completed by DATE
Approval by Highway Supt" Deputy Supt
Upon completion,please resubmit this approved permit for a final approval.
STEP 2: ( }Final Approval
( )Rejected
DATE:
Richard A. Missita,Highway Superintendent
Project Name: BP#
Address:
�T
Building.Permit Submission
Mult4&Dzeelling -C wr7d d Pi4ez
:Checklist
- All items below must be checked either yes,no or not applicable prior to submission'of any building
permit to the Town of QueensburyBuilding Department. If any of the below items are lacking,the permit
will not be accepted until such time as the application is deemed complete for submission._
1. Building Permit Application Completed............ ......... ... ...... ... ... .. yes Qno ❑n/a
2. Energy Form or CheckMate Energy Code Compliance Forms.Complete... Ono ❑n/a
3. Energy Code Inspector's Report from Checkmate.Program...... ... ... ... Ono EJn/a
4. Septic application completely filled out(if applicable)....... ... ....:. ... ... ❑yes Ono
5. Electrical Inspection Form... ...... ... .... ...... ... ......... ... ..:...... .: ❑yes Qno ❑n/a
6. Two(2)sets of plans showing the following: .::... ❑ ❑
6a. Floor plan(s)... ...... ....... ... ... :.................... ... ..:....... ... ... ❑yes Qno ❑n/a
6b. Foundation plan... ...... ... ... ... ...... :.. ... ...... ...... ......... ........❑yes [:]no Qn/a
6c. Cross section(s)... ... ...... ............ ... ......... ... ......... ... ..... ❑yes ❑no ❑n/a.
6d, Elevations ...... ... ............ ... ......... ... ...... ... ... :..... ... . Qyes no ❑n/a
. ❑
6e. Design loads including floor,snow load,and wind load.;.,... Oyes Qno Qn/a-
6f. Seismic design(required after Jan. 1.2003)............ ...... ... ... ... ❑yes Qno ❑n/a
6g. Plans signed by registered'architect or engineer,signed... ... .... ❑yes [:In(? ❑n/a
and sealed by a registered architect or engineer
6h. Window and door schedule... ...... ...... ... ......... ......... ... ... ❑yes ❑no ❑n/a
7. Two(2)site plans showing location of the structure to be built,... ...... Qno Qn/a
location of well or water lines,location of septic system or sewer line with
all setbacks and separation distances shown,and all improvements to
the property.
�,C��
8. Solid Fuel Burning or Gas Appliance Form(if applicable)... . ,.. ... . yes [:]no ❑n/a
9. Driveway Permit... ...... ... ... ...... ... ... ......... ......... ...... ...... ... ... . s ❑no ❑n/a
Date:
Staff Initial:
L:\SueHemingway\Bl"1�.Pernut.FORMS\Generic Check6t.doc
Permit Numbertri CEF/
1 8
MECcheck Compliance Report Checked By/Qate A10 V 200
Proposed New York State Energy Conservation Construction Code 'OW/OFMECcheck Software Version 3.3 Release lb UIIIV��VEEAISBQR
Data filename: C:\Program,Files\Check\MECcheck\completed works\39,Waverly.cck
TITLE:WP 323 Rosemary
COUNTY:Warren
STATE:New York
HDD:7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE: 11/11/02
DATE OF PLANS:November 7,2002
PROJECT INFORMATION:
WP 323 Rosemary
COMPANY INFORMATION:
The Michaels Grop
10 Blacksmith Dr.
Malta,NY 12020
COMPLIANCE:Passes
Maximum UA=444
.Your Home=415
6.5%Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Raised or Energy Truss 1672 30.0 0.0 54
1st fl walls @ 8':Wood Frame, 16"o.c. 468 19.0 0.0 23
lx Master Bath-F:Vinyl Frame,Double Pane with Low-E 6 0.380 2
Ix opt. Study-D:Vinyl Frame,Double Pane with Low-E 14 0.380 5
lx Study-P:Vinyl Frame,Double Pane with Low-E 17 0.380 6
Entry door-#lB:,Glass 37 0.660 24
Garage door-#20: Solid 19 0.350 7
1st fl.walls @>8':Wood Frame, 16"o.c. 1022 19.0 0.0 51
Breakfst Door-#7:Glass 40 0.660 26
2x Family-D:Vinyl Frame,Double Pane with Low-E 27 0.380 10
lx Family-E:Vinyl Frame,Double Pane with Low-E 25 0.380 10
lx Master Bed-A:Vinyl Frame,Double Pane with Low-E 34 0.380 13
2x opt.Master Bed-K:Vinyl Frame,Double Pane with Low-E 20 0.380 8
Ix Dining-L:Vinyl Frame,Double Pane with Low-E 30 0.380 11
Master bed bay opt.:Wood Frame, 16"o.c. 138 19.01 0.0 8
Master bed cath.opt.:Wood Frame, 16"o.c. 21 19.0 0.0 1
.2nd fl.walls:Wood Frame, 16"o.c. 929 19.0 0.0 53
Ix Foyer-U:Vinyl Frame,Double Pane with Low-E 14 0.380 5
Ix Bath-H:Vinyl Frame,Double Pane with Low-E .7 0.380 3
lx Bonus-P:Vinyl Frame,Double Pane with Low-E 17 0.380 6
Floor over garage:
All-Wood Joist/Truss,Over Unconditioned Space ill 19.0 0.0 5
Basement Wall 1:
Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insu1 1273 0.0 11.0 82
3x Basement windows:Wood Frame,Double Pane with Low-E 4 0.560 2
Furnace 1:Forced Hot Air,80 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building
plans,specifications,and other calculations submitted with this permit application. The proposed systems have
been designed to meet the Proposed New York State Energy Conservation Construction Code requirements.,
Builder/Designer Date
MECcheck Inspection Checklist
Proposed New York State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lb
DATE: 11/11/02
TITLE:WP 323 Rosemary
Bldg. j
Dept. j
Use
I
Ceilings:
[ ] ( 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
j Above-Grade Walls:
[ ] j 1. lst fl walls @ 8':Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ ] j 2. 1st fl.walls @>8':Wood Frame, 16"o.c.,R-19.0 cavity insulation
j Comments:
[ ] ( 3. Master bed bay opt.:Wood Frame, 16"o.c.,R-19.0 cavity insulation
j Comments:
[ ] j 4. Master bed cath.opt.:Wood Frame, 16"o.c.,R-19.0 cavity insulation
j Comments:
[ ] ( 5. 2nd fl.walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
j Comments:
Basement Walls:
[ ] j 1. Basement Wall 1: Solid Concrete or Masonry,7.6'ht16.6'bg/6.0'insul,
j R-11.0 continuous insulation
j Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in.below grade.
I
j Windows:
[ ] ( 1. lx Master Bath-F:Vinyl Frame,Double Pane with Law-E,U-factor:0.380
j For windows without labeled U-factors,describe features:
#Panes. Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] j 2. lx opt.Study-D:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
j Comments:
[ ] ( 3. lx Study-P:Vinyl Frame,Double Pane with Law-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes j ]No
j Comments:
[ ] 4. 2x Family-D:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
j For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] j 5. lx Family-E:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
j For windows without labeled U-factors,describe features:
f #Panes Frame Type Thermal Break?[ ]Yes [ ]No
j Comments:
[ ] j 6. lx Master Bed-A:Vinyl Frame,Double Pane with Low-E,U-factor:0.380
j For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
j Comments:
[ ] ( 7. 2x opt.Master Bed-K:Vinyl Frame,Double Pane with Low-E,U-factor:0.380
j For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
8. lx Dining-L:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
9. 1 x Foyer-U:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
10. lx Bath-H:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
11. lx Bonus-P:Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
12. 3x Basement windows:Wood Frame,Double Pane with Low-E,U-factor: 0.560
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
1. Entry door-#lB: Glass,U-factor: 0.660
#Panes . Frame Type Thermal Break? Yes No
Comments:
2. Garage door-#20: Solid,U-factor: 0.350
Comments:
3. Breakfst Door-#7: Glass,U-factor: 0.660
#Panes Frame Type Thermal Break? Yes No
Comments:
Floors:
1. Floor over garage:All-Wood Joist/Truss,Over Unconditioned Space,
R-19.0 cavity insulation
Comments:
Heating and Cooling Equipment:
1. Furnace 1:Forced Hot Air,80 AFUE or higher
Make and Model Number
Air Leakage:
Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC
rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials and 3"clearance from insulation.
Vapor Retarder:
Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
Return ducts in unconditioned attics or outside the building must be insulated to R-6.
Supply ducts in unconditioned spaces must be insulated to R-1 1.
Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] ( All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] ( Air filters are required in the return air system.
[ ] ( The HVAC system must provide a means for balancing air and water systems.
( Temperature Controls:
[ ] i Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] ( Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] ( Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code of New York,State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate,circulating hot water pipes to the levels in Table 1.
� v
Circulating Hot Water Systems:
[ ] ( Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] ( HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the
levels in Table 2.
1
r
Table]: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation.Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Coaling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
• / 1f
RESIDENTIAL FINAL INSPECTION REPORT
Office Na.(518)751-8256 • Date inspection request received:
Building&Code Enforcement
Dept.of Community Development Arrive am/pm Depart arn/pm
Town of Queensbury Inspector's Initials
742 Bay Road
Queensbury,.New York 12804
NAMEmlc'uh,c-o 6'` PERMIT#
LOCATIONw2 CYL DATE_ Z
TYPE OF STRUCTURE
N/A YES NO COMMENTS
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
Plumb Vent through roof
Roof Complete
Exterior Finish Complete
Interior/Exterior Railings 30"to 36"
Exterior Handrails,balconies,Ianding 18 in.or more
Interior Handrails stairs both sides 3 or more risers
Grade 2%away from foundation
8"clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Relief Valve(s)installed
Headroom,6 ft.6 in.on stairs
Basement stairs,6 ft.4 in.
Handrail exterior stairs both sides more than 3 risers.
Interior privacy/trim/doors/main entrance 36"
Floor Finish
Bathroom/Kitchen watertight
Interior Handrails Balconies/Landing 18 in.or more
Railing across window in stairwells
Smoke Detectors:
every level
every bedroom
outside every bedroom
inter connected
Bathroom fans
Plumbing fixtures
Foundation insulation
3/4 hour fire door/door closer
Garage fireproofing
Garage penetrations sealed
Furnace in separate room protected(in garage)
Light ventilation per room
Safety glazing 18"or less from floor
t
lectricPlan/Variance requiredl Survey Plot Plan
As Built Septic System layout required
Okay to issue C/C(Certif.of Compliance)
Okay to issue temp.C/O(Certif.of Occupancy)_
Okay to issue permanent C/O(Certif.of Occupancy)
MAP
REFERENCE:
WAVERLY
PLACE SUBDIVISION
DATED
AUGUST 24, 2000
LAST REVISED
JANUARY 19, 2001
BY VAN
DUSEN & STEVES
LAND
SURVEYORS, LLC
I HEREBY CERTIFY THAT THIS MAP WAS PREPARED
FROM AN ACTUAL FIELD SURVEY.
THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS
FOR WHOM THE SURVEY WAS PREPARED. AND ON TtiL9R
BEHALF TO THE TITLE COMPANY. GOVM*IeNTAL AGENCY
AND LENDNG NSTITUTION LISTED HEREON.
CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL
INSTITUTIONS OR 5U5SEQUENT OWNERS.
CERTMD TO, CYNTHIA A. DAVIS
CITNORTGAGE. NC.. IT'S SUCCESSORS AND/OR ASSIGNS
CHIGAGO TITLE INSURANCE COMPANY
CERTFFED BYl�
MATTHEW C. STEVES. LL5 NYS 50M
DATED MAY G. 2003
E R L
0 1�/ Z,---
P L A
D
^ -�
/`�`J/ /,_'/
Steves
Land Surveyors
Haviland Road Queensb ury, New York 12804
(518) 792-8474 New York IAc. No. 50135
•`w"AMO A LICENSED ""L" OR Vt%%'Y N'° A'
MAP TION OF A 72 LAID I-WASIOM 7EM. q A
Na.Ana� a tccnaM �xo�, aiwa�a a, a THE
NEW YOM STATE WUCATION LAW
•ONLY CO►IOt FROM THE ORIORUL Of TIIIS SUMEY
MAA = " AM OMOINAL OF THE LAID SURVEYORS
1'
THIS SURVEY WAS FWNI E w ACCORDANCE wT THE
EwsIR+D CODE OF PRACTICE FOR LAID wRYEYORs ADOPTED
SY THETHE NEW YORK STATE ASSOCIATION Of PROFEMONAL
IJOD SIRrEYORB. SAD CERIMICATIONB SWl RUN ONLY
ON INS SDIAV rME Ti1lE COMPANY. SOOYERD�IRAL�
% THE ""° `°Dw° w"I"NWIN `�'E° IWK, AND
AQDXY169
� TME As>MaNEEs � �,alowo �++N�•
Map of a Survey made for
CYNTHIA A. DAVIS
Town of Queensbu y
ry, Warren County, York
a eL A
Scale 1'=30'
S -1
/�
SHEET OF 1
DAMS
DWG. NO. 9q312-21
NO.
DATE
DESCRIPTION
MA
Lib-� 0
Residential Final Inspection
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/: ��art: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials
NAME: -N PERMIT
LOCATION: DATE: 7�-,
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in. or more @ stairs,decks,patios
Guard at stairwell at 34 in.or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post.or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
-Low water shut-off boiler
Relief Valves installed
Interior Erivacy/ft-fin/doors/main entrance 36 in.
B#throom/Kitchen waterti&
(Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: t Batter y backup:
Bathroom Fans,if no window
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
3/4hour fire door/door closer
Garage fireproofing
Duct work Scaled properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I sq,ft.-150 sq. ft.vents
Building No./Address visible from road
Final Electrical
Site Plan Wariance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C(Cert. Of Compliance)
Okay to issue Te!p2orary C 0(Cert. Of Occiipancy)
Okay to issue Permanent C 0(Cert. Of Occupancy)
L:\SueHeniffig%vay\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003
Residential Final Inspection
-V% DC)
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm epart: LA' -C.7)am/pm
742 Bay Rd.,Queehsbury,NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments
Y N NIA
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in. or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in.or more
Exterior Finish CoMplete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
-Low water shut-off boiler
Relief Valves)installed
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors: C,0 A41&e-T-
Every level: / Every Bedroom:
Outside every bedroom are : � I V/ rr—
Inter Connected: / Battery backup:
Bathroom Fans,if no window 04*f 490. Av. 16
Carbon Monoxide detector
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf ou7—
Emergency egress below grade
Basement stairs closed rise>4 inches
1/4hour fire door/door closer
Garage fireproofing
Duct work Sealed properly
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I sq, ft.-150 sq. ft.vents
Building No./AddEpIs-visfille from
Final Electrical
Site Plan /-VariiaLn4 req4ire& Od
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification,if required
Okay to issue C/C(Cert. Of Compliance)
Okay to issue Te!pporary C/0(Cert. Of Occupancy) V/
Okay to issue Permanent C/0(Cert, Of Occupancy)
L:\SueHeming�vay\BLiilding.Codes.Inspection.FORMS\Res.Final Insp.form 2,doe edited January 28,2003
- Town of Queensbury
Fire Marshal's Office
742 Bay Road
Queensbury, NY 12804
Phone(518)761-8205 Fax(518) 745-4437
Fire Marshal's Inspection Report
Request SCHEDULE
Received: Permit# - INSPECTION ON;
Name; �� �� � �(? l�N� d U d`1 PM ANYTIME
Location: av
APPROVED
N/A YES NO COMMENTS
EXITS
AISLE WIDTHS
EXIT SIGNS-NORMAL
- BATTERY
EMERGENCY LIGHTING
FIRE EXTINGUISHERS
FIRE ALARM SYSTEM
FIRE SPRINKLER SYSTEM
FIRE SUPPRESSION SYSTEM
HOOD INSTALLATION
INTERIOR FINISHES
STORAGE
COMPRESSED GAS
CLEARANCE TO SPRINKLERS
CLEARANCE TO HEATING
UNITS
CLEARANCE TO ELECTRICAL
REQUIRED SIGNAGE
EMERGENCY PLAN
MAXIMUM OCCUPANCY SIGN
CHIMNEY
MAS NRY ROUGH IN
FINAL
CHIMNEY
FACTORY BUILT ROU IN
FINAL .
WOOD
STOVE . ROUGHIN
FINAL
VENTED GAS
APPLIANCE ROUGH IN
FINAL _
FIREPLACE
MAs NRY ROUGH IN OK THIS DATE OKFORCO OT OK
FINAL -
FIREPLACE
FACTORY BUILT ROUGH INSPECTED BY
FINAL
COMDEV/CHRISJ/WORD/LETTERS2Q01/FIREMARSHALINSPECTIONREPORT11022001
WHITE-BUILDING DEPARTMENT COPY YELLOW-.00CUPANT COPY
Rough Plumbing /_Insulation Inspection e'ort
No. (518)7b 1-8256 Date Inspection request receive � 3
sury Building&Code Enforcement Arrive.. aznJ D �? a
ad,Queensbury,NY 12804 Inspcctor's.Initial
5
`G �='l S PERMIT#:
NAME:. .
LOCATION: INSPECT ON: " 3
TYPE OF STRUCTURE:
Y N- N/A � E
PVC: R-1,R-2,R-3,R-4 Drain l Vents � �
Cast Iron,Copper Drain/Vent/Comm.
��aW��-`-6
Plumbing Vent 1 Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents 1
5 PSI or 10 ft.above highest "
Connection for 15 minutes
Water Supply Piping
Copper Commercial
r, C,Pex One&Two Family
sulatlan Idential Check/Commercial Check
Proper Vent,Attic Vent
Duct[Hot Water Piping Insulation
Ifrequired unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS: i �c �v'aflc`�. tP
t-\P� CC' 3GO 3,
-L:\SucHemirigway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January N,2003.
Foundation Inspection Report
Office No. (51'8)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ ep am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: C_; PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUMIZE: I V
Comment7
Y /Ni N/A
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this pyTose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil of for wet areas Linder slab
Backfill Approval 4P
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Suelien ingway\Buildi.ng,Codes.Inspection.FORMS\Foundatiun Inspection Report,doc January 28;2003
Rough Plumbing/ Insulation Inspection Report
Office No. (518)761-8256 Date Inspection reques cei
a In. e t:
Arrive: a h
Queensbury Building&Code Enforcement m
742 Bay Road,Queensbury,NY 12804 Inspector's Initia
NAME: PERMIT#:
LOCATION: INSPECT ON: 63
TYPE OF STRUCTURE:
N/A.
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper Drain/Vent Comm.
PlumbinE Vent/Vents in Place
Q�ough Pl�umVing�/ ail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
er PVC,Pex One&Two Family
IMsdrat—ion/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping insulation
If required unheated sTaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
-L:\SueHemiiigway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection req eceix,9
Queensbury Building& Code Enforcement Arrive: pm art: a
742 Bay Road, Queensbury, NY 12804 Inspector's In Is:
NAME: S PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
fy Y N N/A
Framing COMMENTS
C�l X M11 V'2—
J—a-=t—uds/Headers
Bracing/Bridging
Joist hangers FAQ
Jack Posts Main Beams COMMENTS
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\BLlilding.Codes.Inspection.FORMS\Framitig Firestopping Inspection Report.doc January 28,2003
Rough Plumbing/ Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: -=, � f
Queensbury Building&Code Enforcement Arrive:-am/pm Q Depart:' M/pm
742 Bay Road,Queensbury,,NY 12804 Inspector's Initials:
NAME: G PERMIT#:
LOCATION: i INSPECT ON: Zk-
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain Vents � �,,,,. ��1���, ; 1�
Cast Iron,Copper Drain/Vent Comm'
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper,CPVC,Pex One&Two Family
Insulation/Residential Check/Commercial 1 fleck
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
L:\PamW\Whiting\Rough Plumbing Insulation Report.doc
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection r q rece ed:
Inspection
Queensbury Building&Code Enforcement Arrive: a p Depart:
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi
NAME: M-CN1'n2..0Q-1) G-/��o ERMIT#: Lo
LOCATION: 2,c� a- I INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
oundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
�Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
-15-mil poly for wet areas under slab
ackfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
Office Use
.GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time.,
Dept. of Community Development Request received: —1?4Z Meet:
Building& Code Enforcement At time:
742 Bay Road
ARRIVE am/pm: DEPAR Notes:
Queensbury, AT 12804 amlpm
(518) 761-8256 Inspector's Initials
NAME: Ike 41.1-� PERMIT
--Z11 "I C
LOCATION: INSPECT ON(date):
TYPE OF.STRUCTURE:
RECHECK
N/A YESXO COMMENTS
QF:o:o3 gs/Pi
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
"Foundation/Wallpour
Reinforcement in Place
Foundation/Danipproofing_
Backfill Approval
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing__
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air Infiltration.Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping_
L,\SueHemiiigway\Building.Codes.Iiispection.FORMS\GF,NERAL INSPECTION REPORTA00
2,002,- 'N RECEIVEJ)
N0 V 8 2002
Bu1LD1 aG,��U SBU Y
_ r
ek-
f r3?�
^I
N N
—_
( c0 N
2�.6-6.
L A �