2002-999 TOWN of QUEENSBURY
742 Bay Road,Queensbury,NY 12804.5902 (518)761-8201
Community Development-Building&Codes (518) 761.8256
nrDT " ITE " OCCUPANCY
utal IFI%.Jal VJU
Permit Number. P20020999 Date Issued: Tuesday,June 27,2006
This is to certif that work requested to be done as shown by Permit Number P20020999
has been completed.
Tax Map Number. 523400.308-012-0002-072-000-0000
Location: 35 STEPHANIE Ln
Owner: JOHN&NANCY CORDIALE
s ` Applicant JOHN&NANCY CORDIALE
This structure may be occupied as a:
Residential Addition By order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
(97
Variance,or other issues and conditions as a result of approvals by the Director of Binding&Code Enforcement
:Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20020999 Application Number: A20020999
Tax Map No: 523400-308-012-0002-072-000-0000
Permission is hereby granted to: PROFESSIONALBUILDINCT SYSTEMS
For property located at: 3 5 STEPHANIE Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tne of Construction Value
Owner Address: JOHN &NANCY CORDIALS Residential Addition 25,000.00
35 STEPHANIE Ln Total Value 25,000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
PROFESSTONAT, BTJTT,DTNG SYSTEMS
663 STATE RTE 149
LAKE CIFORCIR NY 12945-0000
Plans&Specifications
2002-999
Construction of a 325 sq ft residential addition per plot plan and specifications.
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,December 13,2003
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the own Que bu 1F ida December 13,2002
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No.-.2,6h2-' G
No inspection will be made until applicant has received a Fee Paid $72
valid building permit. All applicants' spaces on this Rc a Fee Paid $
application must be completed and must appear on the Reviewed By
application form. [; : 2002
T*OVVN or-
Applicant:. t S BUILOidt %U v t.�. c
Address: 4- Q�� rim
t.-1k•irc � �- 1.>'� i ,�4 45 ci �ih2`T' i\r''� tZ�4
Phone#(5&)-7 t'2- Phone#(`2
Property Location: Lot Number: / House Number w7IE3- (-
Subdivision Name: Tax Map Number: : r-2 •- 2
❑ New Building: residence /commercial Estimated Market Value of Construction: $ 5�
16. Addition: residence commercial If an Addition,what will use of new addition be?
❑ Alteration: ence/ commercial
❑ No change to exterior size: residence/com'1 T ?tom
II Other work(describe )
Check OeeupancyTnformation I"t Floor 2' Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
❑ Single family dwelling l
❑ Two family dwelling /
❑ Townhouse /
❑ Multifamily dwelling
#of units \
❑ Office
❑ Mercantile
❑ Manufacturing
❑ 1 car detached garage /
❑ 2 car detached garage
❑ 3 car detached garage
❑ 1 car attached garage
❑ 2 car attached garage
❑ 3 car attached garage
❑ Storage building-
commercial
b Storage building-
residential
Other 125-<-8) —
N"at-is the proposed height of the structure feet _inches
Will any second-hand or ungraded lumber be used? If so,for what? `-IQ
Type of Heating System: electric of / gas/wood /forced hot air baseboard other:
Number of Ri (aces to be installed Number of Woodstoves to be installed /
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address Phone Number
Builder } cs) 8ujo i - S - 5i
Plumber -(}i t 1,
Mason i t
Electrician
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Itwe shall ,
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual
location of all new Jconstruction.
Signature(./_ £ t� _� owner,owner's agent,arehitec contractor
i Q
Fetion
ber
MECCkeek Compliance ReportateProposed New York State.Energy Conservation Conste
MECcheck Software Version 3.3 Release 1 b
Data filename:Untitled
TITLE: Cordiale Residence
COUNTY:Warren
STATE:New York
HDD:7635 {`
CONSTRUCTION TYPE:Detached I or 2 Family
HEATING TYPE:Non-Electric
DATE: 12/03/02
DATE OF PLANS: 11/29/2002'
PROJECT INFORMATION:
13'x 25' Addition
COMPANY INFORMATION:
Professional Building Systems
NOTES:
Energy Audit
COMPLIANCE:Passes
Maximum UA=97
Your Hoene=77
20.6%Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R Value U Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 350 30.0 0.0 12
Skylight 1:
Metal Frame with Thermal Break,Double Pane with Low E 3 OA80 . 1,
Wall 1:Log:8"Diameter Logs 104 11.0 5
Wall 2:Log:8"Diameter Logs 200 11,0 7
Window 1:Metal Frame,Double Pane with Low E 27 0.330 9
Door 1:Glass 20. 0.230 5
Wall 3:Log:8"Diameter Logs 117 11.0 5
Wall 4:Log:8"Diameter Logs 200 11.0 8
Door 2:Glass :..__._. .. .... 40 0.260 10
Floor 1:All-Wood Joist/Truss-,Over Unconditioned Space 325 . 19.0 ' 0.0 15
Boiler I:,80 AFUE
COMPLIANCE STATEMENT: The proposed.building represented in this document is consistent with the building
plans,specifications,and other calculations submitted with this permit application. The proposed systems have been
designed to meet the Proliosed New Yoik State nergy Conservation Construction Code requirements.
Builder/Designer Date r- 0
4
Q4pF�SSIdNq�F
T6���'c��
G
si 037 g
lyOf THE SZA���F
f
s t
i
[ ] I Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non IC
J rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
J materials and 3"clearance from insulation.
Vapor Retarder:
[ ] I Required on the warm-in-winter side of all non-vented firamed ceilings,walls,and floors.
I .Materials Identification:
[ ] J Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
{ ] I Materials and equipment must be identified so that compliance can be determined.
{ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
I equipment must be provided.
{ ] J Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
J
Duct.Insulation:
[ ] I Supply ducts in unconditioned attics,or outside the building must be insulated to R 11.
[ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] I Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R 2.
. I
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted-
Exception. Continuously welded and locking-type longitudinal joints and seams on ducts
J operating at less than 2 in.w.g.(500 Pa).
[ ] J Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ j I Cooling ducts with exterior insulation.must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I -
Temperature Controls:
[ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
I temperature set point of the largest zone.
J Electric Systems:
[ ] J Separate electric meters are required for each dwelling unit.
I "
I Fireplaces:
[,}.aj. I Fireplaces must be installed with tight fitting,non-combustible fireplace doors.
] J Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code of New York State or
I the New York City Building Code,as applicable.
J Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
J waterheater has an integral heat trap or is_part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
• I .
Circulating Hot Water Systems:
[ 3 I Insulate .circulating hot water pipes to the levels in.Table 1.
I -
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch'and require a cover unless over 20%
I of the heating energy is from non-depletabrle sources. Pool pumps require a time clock-
Heating and Cooling Piping Insulation:
{ ] I HVAC piping conveying fluids above 105°F or chilled fluids below 55 iDF must be insulated to the
levels in Table 2. .
Table 1:-M ithimm Insulation Tkickness for Circulating Hot Water Pipes:
Insulation Thickness in'Inches by Pipe Sizes
Heated Water Non-Circulatink Runouts ;. Circulating Maims and Runouts
Temperature{P). Up to l' Up to t.25" 1.5"to 2.0 0ver2"
170480 0.5 1.0'. 1.5 2.0 -
140-150, 0.5 t 0.5, 1.0 1 5
100-130 0.5 '0.5- 0.5 1.0
Table 2_ Minimum Insuladon-Tlikkness for HVACPipeL
Fluid;Temp. Insulation Thiclaie'ss`in Inches by,Pipe Sizes
Piping System Types Ran e F 2'Rumouts I°and Less i.25"to 2"'26"to-0 .
Heaoi►g systems
Low Pressure/Temperature 201 250 1A 1.5 1.5 " 2 0
Low Temperature' 120 200 0.5 1.0. ".1.0 1.5
Steam Condensate(for feed water) . . .Any,t 1.0 1.0 .
Cooling Systems
Chilled Water,Refrigerant, 40=55t 0.5 0.5 0.75 _ ' 1.0 ;
and Brine Below 40 1'.0 1.0 1.5 1.5
f
NOTES TO FIELD(Building Department Use Only)
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart: am/pm
Date Inspection request received: Inspector's Initials:;4 IA
NAME: PERMIT#:
LOCATION: 1-;-,5C DATE:
TYPE OF STRUCTURE: j2tjE�;�
V— Comments
Yes No N/A
Building Number/Address visible from road
Chimney Hei&/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Coalplete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: "-- Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, I sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping.finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum Y2"Gypsum
Basement stairs closed rise>4 inches
GaraLe Floor Pitched
Garage fireproofing/1/4hour fire door/door closer
Duct work Scaled properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan L
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent KZr
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised—100405.doe
COMMONWEALTH ELECTRICAL INSPECTION SERVICE, INC.
Main Office 176 Doe Run Road - Manheim, PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
NO 9 3 5 6 6 Pelt i '�/!t#il.left.#flffiNfitfifi}}ii##1##flr.fi•# Cut-i Card NVf.11#i!#11#ifliilNillli##itlf##/i!!f
Owner,,MMMMM z6a,n. .(.# f.1.4igiii• i. ize # # 6111t.l lflfffl..fff../ifffff1l.ilf!!I##1poll 111f##1#oll 1•f/#i##1f#I..i 1.#lie..#f.ti
jo�'
Location [ �� �'+�),AfIlf! /17{1 I1�( (!_
N##I.J.l e!#itoo*M' i#r+`#itftl�l.M/I i!#i.'/t li�R1.1##l.fN li !owteo......tt#t.ot14#H#1l4N#t.t.ttu###...f.1#itsetoffMeetnilltlituf#i#li/toot
InstaHation Consistin f ellltitif ttifi. f. .iiwJ7 t}i 1 17 ! �4 " Clog
frf liilfWiMft #1#4af i*tfrHi t.tffff.tff.#• . l..a of.n .g telM f.u.tff..f.
•face. ff.11N 8 1#To I is e fflf /ffff1.1f11 #11Nf, fit.fH.fff.tff.f.1......ffNlllliti W##to.f...i*##0#1f.1i##N#lit.f.fffrft...fiffiff.e fif 1/109 fHfNtffi.t..i..fff tff.ftfff
i too Hlf.eef..f#efleefile11i.1.effete Steel ifi11/111Ntif@.Igloo l toggle 1.flf smut feiltlloll litt#fififtlf I fie#Hilt#11##t.11#if.ttl.1tiltte feet life I moo 10116164 flit e f Nut t. WO
InsdedBylooloof# I MillillI feet Itolelffteifl..ii11 sell 1111tlt##lot offi11fH1.1iiLie. No.
f.lapNwHott ileilo##Met fuflli#ttifito#iit#r
The conditions following governed the issuance of this certificate, and any certificate previously issued is
cancelled: -
This certificate only covers'the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations, application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules are violated, the Company shall have the right to revoke this certificate,
Date lfeRpli uffel �eui INSPECT
# i toilolo##loiiH i1 t f.1.t.4.. ♦# . o . . . .ei1 iiio111#itHFMN1et11eeeteUrfuunii.fl
Vomhnr N T+P A TAP.i
Queensbury.Building & Code Enforcement- Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart: ( am/ m
p
Date Inspection request received: Inspector's Initials: � Q
NAME: PERMIT#: � /
LOCATION: DATE: /041
TYPE OF STRUCTURE:
CC�rraa�aetuts
Yes No N/A is
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location j
Fresh Air Intake ( v
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails R,stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safe llaazin /Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft. W`�' I C )
egress below grade Gas
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Terap 110
Enclosed Stairs Sheetrock Underside minimum%z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/a hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass'Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/D[Temporary/Permanent]
L:\Building&Codes FormslBuilding&Codes\Iiispection Forms\R.esidential Final Inspection Form—revised 100405.doc
RESIDENTIAL FINAL INSPECTION REPORT
Office No.(518)761-8256 Date inspection request received:
Building&Code Enforcement
Dept.of Community Development Arrive am/pm Depart � _
Town of Queensbury Inspector's Initi s.
742 Bay Road
Queensbury,New York'12804
LO�ON DATE T#
TYPE OF STRUCTURE
N/A YES NO COMMENTS
Chimney HeightPT"Vent/Direct Vent Location
Fresh Air Intake
Plumb Vent through roof
Roof Complete
Exterior Finish Complete ��
hiterior/Exterior Railings 30"to 36"
Exterior Handrails,balconies,landing 18 in.or more
Interior Handrails stairs both sides 3 or more ' ers f
Grade 2%away from foundation
8"clearance to sill plate
Gas Valve shut-off exposedlregulator 18"above grade l �l
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Relief Valve(s)installed
Headroom,6 ft.6 in.on stairs
Basement stairs,6 ft.4 in.
Handrail exterior stairs both sides more than 3 risers
Interior privacy/trim/doors/main entrance 36"
Floor Finish
Bathroom/ e watertight
Interior H drails Balcomes/Landing 18 in.or more
Railing across window in stairwells
Smoke Detectors:
every level
every bedroom
outside every bedroom
inter connected
Bathroom fans
Plumbing fixtures
Foundation insulation
3/4 hour fire door/door closer
Garage fireproofing
Garage penetrations sealed
Furnace in separate room protected(in garage)
Light ventilation per room
Safety glazing 18"or less from floor
Final Electrical
Site Plan/Variance required
Final Survey Plot Plan
As Built Septic System layout required
Okay to issue C/C(Certif.of Compliance)
Okay to issue temp.C/O(Certif of Occupancy)
Okay to issue permanent C/O(Certif.of Occupancy)
Rough Plumbing 1 Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request 8 receive . 410
j
Queensbury Building&Code Enforcement Arrive: amlp D Pa .
742.Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: 4I� ► PERMIT
LOCATION: .35 ice.� INSPECT ON: "j
TYPE OF STRUCTURE: LL�d:t,.
Y N N/A
V R-1,R-2,R-3,R-4 i en
ast Iron,Copper Drain Went/Comm. ��(- t �
Plumbing Vent/Vents in Place LDc7R-'
au h Piumbin ail Plates C�
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes '�b�cl/
Water Supply Piping,
PP Y P g,
Copper Commercial '
&Two Family
atmn< esidential Check`/Commercial Check
CIO
Proper Vent,Attic Vent k,0 kA, � t x
Duet/Hot Water Piping Insulation.
If required unheated spaces
Combustion Air Supply for Furnace .�
Duct Work Sealed Properly
COMMENTS: �i)LA vc>�s t'
L:1Fa'nmWhitinSUtough Plurnbin
g h.
tepport.doc
Framing/ Firestopping Inspection Report i
Office No. (518)761-8256 Date Inspection request received:—) 7-1-e
Queensbury Building&Code Enforcement Arrive: am/pm?D p"a,
742 Bay Road, Queensbury,NY 12804 Inspector's hiitials1./,-".'_
NAME: C-Y- PERMIT#: coo
9
LOCATION: '�,q S 'j-e-. t_,-j AfC- INSPECT ON:
TYPE OF STRUCTURE
Y N N/A COMMENTS
raming . .............
J Stu�s
Jack Studs Headers
Bracing Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. Allf"
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.-
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft.floor trusses
Anchor Bolts 6 ft.,or less on center
Ice and snow shield 24 inches from wall
Fire separation 1,2,3 hour
Fire wa11-2, 3,4 hour
Firestopping,
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2inch or 5/8 inch Type X
Garage'side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)'
20 in. (W)
5.7 sf above below grade
5.0 sf grade
Office Use
GENERAL INSPECTION REPORT Inspector:
Town of Queensbury Ready at time
Dept. of Community Development Request received: Meet:
Building& Code Enforcement At time:
742 Bay Road
Notes:
Queensbury, AT 12804 ARRIV a EP In
(518) 761-8256 Inspector's Initia
Cnq M vn
IT T 4 ii _
NAME: ri Q.2 PERMIT FIR
LOCATION: P, INSPECT ON(date):
TYPE OF STRUCTURE:
RECHECK
N/A YES NO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is responsibl or
'ons
f r
providing protection from fr zing
for 48 hours following the pl cement
of the concrete.
n s*.
Materials for this purpose oT_
Foundation/Wallpour
Reinforcement in Place:
Fo ation/Dampproof4ie I
-, ckf 11 Approval " I
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing_
Heating Rough-In--
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-1
Floors R---)
Walls R-
Ceiling R-
Duct work or piping mi
unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bracing/Bridging-
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping
L:\SueHemingway\Building.Codes.Inspcction.FORMS\GF.NERAT,INSPECTION REPORT.doe
fENERAL REPORT
( 518 ) 761--8256
Town of Queensbury
Dept.of Community Development Date inspection request received:
Building&Code Enforcement
742 Bay Road
Queensbury,NY 12804 Arrive am/pm Depart W
Inspector's Init'
NAME: 6-,E> PERMIT# 7 �
LOCATION: DATE: —�
TYPE OF STRUCATRE: 1NKL-7->
RECHECK.
NIA YESXO COMMENTS
Footings/Piers
Monolithic Pour Form
Reinforcement in Place
The contractor is respo ib for
providing protection fr,,m fr zing
for 48 hours following a pl cement
of the concrete.
Materials for this purpose o s to
Foundation/Wallpour
Reinforcement in Place
FoundationMampproolm
Backfill Approval
Plumbing Untier-SI96
Plumbing VentlVents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing
Jack Studs/Headers
Bra
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2, 3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestopping
Office Use
GENERAL INSPECTION REPORT Inspector:
.Town of Queensbury Readyattime: (?X-,
Dept. of Community Development Request received: Meet:
Building& Code Enforcement At time:
742 Bay Road
Queensbury, NY 12804 ARRIVE am/pm: DEPAR Io6R Notes:
(518) 761-8256 Inspector's Initials
NAME: PERMIT#
LOCATION: INSPECT ON(date):
TYPE OF STRUCTURE:
RECHECK
N/A YES NO LEN
Footings/Piers
Monolithic Pour Form
Reinforcement in Place V3
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Is_
lateria, _for this purpose-on-site
%N Youndation/Wallpour
7A RI inforcernent in Place
Foundatiori/Darnpproofing_
Backfill Approval
Plumbing Under Slab
Plumbing VendVents in Place
Rough Plumbing_
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent,Attic Vent
Framing_
Jack Studs/Headers
Bracing/Bridging_
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2, 3,hour
Penetration Sealed
Fire Wall 2,3,4 hour
Firestoppmg_
L:\SueHemingway\Building.Codes.Inspcction.FORrvlS\GENERAI,INSPECTION REPORT.doc
�t INSPECTION
4ffi'ee Use
.GENERAL. INSPECTIO REPORT Inspector:
Town of Queensbury Ready at time:: ::
Dept. of Community Development ,Request received:. l t t �- Meet:
Building c& Code Enforcement At time:
742 Bay road
Queensbur}; AT 12804 ARRIVE 4-ramli�D PART am/ Notes:
7 —
(518) 761-8256 .Inspector's.Initials f ' �r
NAME: r �(iL� PERMIT#
LOCATION:--- � /u�t-�, lrtvtr� INSPECT ON(date): _ �.. i PLVI Atj '�
TYPE OF STRUCTURE: �. 1 4—i62�n
RECHECK
_ _ N/A YES NO COMMENTS
�( ootingslPiers
Monolithic POUT Form.
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
'Foundation/Wallpour
Reinforcement in Place
Foundation/Dampproofing /
Backfill Approval_
Plumbing Under Slab
Plumbing Vent/Vents in Place
Rough Plumbing
Keating Rough-In
Insulation
Foundation Walls Interior R-^�
Foundation Walls Exterior R-
Floors R-
Walls It-
Ceiling R-
Duct work or piping in
unheated spaces R- ti
Proper Vent,Attic Vent
Framing _
Jack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier
Fire Separation 1,2,3,hour
Penetration Sealed
Fire Wall 2,3,4 hour —
Firestopping _
L:1SueHemingway`Building.Codes.Inspection.FORMS\GENERAL INSPECTION RF.PORT.doc
En ink eering Evaluation of Residential Building Plans Sob d
Professional Building Systems (Robert Aspholm) (3 sheets) DEC 0 9 2002
for: Cordiale Residence, Queensbury, New York 12804 TOWN OF
OWING AND CO��
1. This is a single-story one-room log addition to an existing residence.
2. Floor joists 2"x10", 16" O.C. with clear span of approximately 12f1. will provide for a
satisfactory total dead and live load of 50 PSF.
3. Roof support Js by pre-engineered trusses 24" Q.C. with a pitch of 5" in 12" on the
exterior roof surface. The truss manufacturer shall be responsible for the design and
construction of all trusses to support a live load of 48 PSF normal to the roof surface plus
all dead loads of roofing, lumber, insulation and ceiling finish. The contractor shall be
responsible for the installation and bracing of all trusses per instructions from the truss
manufacturer.
4. There is no basement---only crawl space with sand floor. Foundation walls are 8" wide
concrete blocks on' 16"x8" reinforced concrete footings at least 48" below grade. The
new 8" concrete block foundation walls shall be securely anchored (vertically) to the
existing concrete wall with a minimum of three (3) %" rebar dowels per vertical 8" wall,
each 4"into new 8"block and 4"into existing concrete wall(epoxyed in place). The new
8"block is to have cores filled with concrete from footing to top of wall at joints with the
existing concrete wall. The new 8" concrete block walls to have two (2) vertical#4 rebars
61-7ft. O.C. from footing to top of waif-;(under cap) and in the two block wall corners.
The block cores, at rebar-locations, are to be filled completely with concrete from footing
to top of wall(under cap). All new block mortar is to be Type M or S and new walls are
to be keyed or doweled to the footings.
5. Ceiling height and insulation are acceptable as noted on plans.
6. All design and construction shall comply with the latest edition of the New York State
Uniform Fire Prevention and Construction Code and The National Electric Code and with
any applicable local building codes and/or regulations.
��OF�SS10ryq
illiam E.Montgom Jr.PE
Dated: December 9, 2002
— - �- Work No.02-12-A49
'
o
fly 037419 �
�FrHE SThAt