Loading...
2002-1037 r +� t TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12845902 (518)761-8201 A Community Development-Building.&Codes (518)CER"I"IFICATE a F O'CrIT Y Permit Number: P20021037 Date lssued: Thursday,February 20,2003 This is to certify that work requested to be done as shown by Permit Number P20021037 has been completed. Tax Map Number: 523400-288-012-0001-017-000-0000 Location: 1476 STATE ROUTE 9 Owner: GPG FINANCE II,L.L.C. Applicant: CARTERS FACTORY OUTLET This structure may be occupied as a: By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20021037 Application Number: A20021037 Tax Map No: 523400-288-012-0001-017-000-0000 Permission is hereby granted to: CARTF,R`S FACTORY OIITI,F,T For property located at: 1476 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GPG FINANCE II,L.L.C. 103 EISENHOWER Ave Commercial Alteration 50,000.00 Total Value 50,006.00 ROSELAND,NJ 07006-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2002-1037 CARTERS 4100 SQ FT COMMERCIAL INTERIOR ALTERATION(797 SQ FT OF IT WILL BE STRUCTUAL ALTERATION)AS PER APPLICATION $95.64 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,January 14,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Tuesday,January 14,2003 SIGNED B for the Town of Queensbury. Director of uilJ' e Enforcement Building Permit Application Town of Queensbury-Dept of Community Development, 742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. —103-7 No inspection will be made until applicant has received a Fee Paid $M5_614 valid building permit. All applicants' spaces on this Rec.Fee Paid application must be completed and. must appear on the Reviewed By: application form. Applicant._Ukes C/,o 't�,�U Owner: o Address: L--2>--X7 -(>C>S-+ f 4 9�C, Addressc -T-C)"6X_)CQ- Phone#(5XO)l 5_ -0D Phone# (ajD 44, Email Address: Email Address: Property Location: Lot Number: I House Number Subdivision Nanie:1-bla6 ck-N4 Czx-r%_�Tax Map Nurnber: E3 New Building: residence /commercial Estimated Market Value of Construction: $ u Addition: residence/_Qornmercial If an Addition,what will use of new addition be? Alteration: residen com=mer la '013 No change to exterior size: residenct,t com'l L3 Other work(describe Check OccupancyInformaiion I`Floor 2d Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet 0 Single family dwelling cl Two family dwelling c3 Townhouse U Multifamily dwelling #of units U Office 0 Mercantile a -Manufacturing u 1 car detached garage C3 2 car detached garage 0 —car detached garage 13 1 car attached-garage 13 2 car attached garage U 3 car attached garage 0 Storage building commercial C3 Storage building- residential C3 Other What is the proposed height of the structure W inches Will any second-hand or ungraded lumber be used? If so, for what? Type of Heating System: electric/ oil / gas/wood /forced hot air baseboard othet: Number of Btrenlaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for super-vision of work as regards to building codes: Name Address Phone Number Builder Plumber --Mason Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall' submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;idrawn to scale,showing actual location oPla-A new construction. -!�CXAU"j, Signatur( 'qu <_ ,e 014_filbQvner, o er's age , chitect,contractor i. COAMERCIAL FINIAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive am/pm Depart pm 742 Bay Road Inspector's Initial Queensbury,NY 12804 NAME '� PERMIT# QJ.-I 0 3� LOCATION c L DATE, -, (5_Q TYPE OF STRUCTURE I / N/A YES NO COMMENTS - Chimneyl"B"Vent/Dired Vent location Plumbing Vent Roof Complete Exterior finish grade complete Laterior/exterior guardrails 42 in.platform/decks Interior/exterior ballasters 4 in.spacing platfonm/decks Stair handrail 34 in.-38 in. Step risers 7 a/.in. Main door 44 in. All others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit.doors Gas valve shut-off exposed&regulator(18 in.)above gra Floor bathroom watertight Other floors okay Hat water relief valve Boilertfumace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 '/z doors 1 ''i hour doors and closers '.hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour c oMlcte Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/z hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinkshoilets Handicapped bath/parking lot sighage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures .As-buik septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) Town of Queensbury Fire'Marshalls Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4]437 Fire Marshal's Inspection Report Request it# 10 37 SCHEDULE Received: Perm INSPECTION ON, Name: OLIOLOld ?, A%fPM NYTIME Location: APPR6VED N/A YES NO COMMENTS EXITS AISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION I INTERIOR FINISHES a C7,-- STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS , CLEARANCE TO HEATING UNITS CLEARANCE TO ELEC-TKCAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGH IN FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGHIN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN OK THIS THIS:DATE OK F70 CO IN 0—T. 0 K FINAL FIREPLACE FACTORY BUILT ROUGH IN INSPECT" FINAL COMDE11ICHPJSJIWORD/LETTERS20011FIREMARSHALINSPECTIONREPORT11022001 WHITE--BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY 'FINAL - COMMERCIAL INSPECTION ZTR T Request received: 65 Office Use Town of Queensbury (518) 761-8256 ARRIVF.�-�-f` am/pm: DEPART am/pm 742 Bay Road Ready at time:RK4 QueensburyyT 12804 Inspector's Initials w- 4 (_5e�r- Meet: NAME i /n PERMIT At time: LOCATION TYPE OF STRUCTURE 3CT ON(date): 1/03 Notes: N/A YES NO Chimney/"B"Vent/Direct Vent location Plumbing Vent Roof Complete COMMENTS Exterior finish grade complete 1�.— 61f:7, I I Interior/exterior guardrails 42 in.platform/decks 4- 4q /1. 9 )-�m�— Interior/exterior balusters 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Step risers 7 3/4 in. 44,-4 Main door 44 in. All others 36 in. Lover handles L -A--r Exits at grade or platform Canopy to cover req. exit doors Gas valve shut-off exposed&regulator(18 in.)above grade_ Floor bathroom watertight_ Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 Gas furnace shut off within 30 ft. or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door Storage/receiving/shipping room(2 hour), 1 V2 doors I V2 hour doors and closers y %hour corridor doors and closers Firewalls/fire separation,2 hour,3-hour complete Fire dampers,2-hour fire wall/separation or greater Fire door/shutters I V2, hour,3 hour Ceiling fire stopping 3,000/5,000 sq. ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in, Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required Okay to issue TEMPORARY C/O—Certificate of Occupancy yes_ no Okay to issue PERMANENT C/O—Certificate of Occupancy yes_ no Okay to issue C/C—Certificate of Compliance yes_ no COAUKERCL4,L FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: ll t13 Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive�,1 W am/pm Depart am/pm 742 Bay Road Inspector's Initials'_! Queensbury,NY 128 2 } NAME � � PERM lTr# 6 3 7 LOCATION 1 i TE 3 TYPE OF STRUCTURE ►+.� '� N/A YES NO CON MIM A& ChimneyP'B"VaWDired vent-location Plumbing Vent Roof Complete Exterior finish grade complete Dior/exterior guardrails 42 in.platform/decks Interior/exterior ballasteas 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Sup risers 7 3/4 in. Main door 44 in, All othes 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18 in.)above gra Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,000.000 BTU's(I hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 301 or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/2 hour door Storage/receiving/shipping room(2 hour), I z/z doors // / / 1 14 hour doors and closers r a -4 r v/ c��'' t' -- '.hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators !��r�aM Elevator signage Handicapped bathroom grab bars/sinkshoilets j Handicapped bath/parking Id.signage �d J��/ ft� (3' J!(�✓ Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous,/12 in.beyond Active listening system and signage assembly space Final Electrical Site PlanNariance required Final Survey,new structures As-buih septic system layout required Okay to issue temp.C/O(Certif of Occupancy) Okay to issue permanent C/O(Certif.of Oocupancy) Okay to issue C/C(Certif.of Compliance) i Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: - .... am/Dm oDepart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials kp— NAME: PERMIT#: PSI LOCATION: a INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS -v"Framing Jack Studs/Headers Bracing/Bridging Joist hangers_ Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in.- Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above 1 below grade 5.0 sf grade Robert F. Vanney Architect MEMORANDUM David Hahn,Director TO: Town of Queensbury,NY;Building and Code Enforcement FROM: Kent Roemhildt DATE: 6 January,2003 PROJECT: Carter's,Factory Stores of America,Lake George,NY COMM.NO. 16-0062 SUBJECT: Response Letter Comment response list follows(all comments referring to drawings,have been bubbled with revision#1): Plan Check Correction List 1) Sheet A4:Elevations show stockroom wall going to structure above to create a one-hour rated wall. 2) Sheet A3 and El:Reflected ceiling plan shows three emergency lights added to plans. One light fixture added in the stockroom and two light fixtures added in the sales area. 3) Sheet A!:Handicap grab bars were added to the h.c. changing room. 4) Sheet Al:There is a note,in a box near the cashwrap,calling out the height of the cashwrap to be at 34"a.f f. Thank You, Kent Roemhildt //9/63 Ned 5 V 4tl c,,//J A,/ 441 COPIES TO: 360 North Robert Street,Suite 201 Saint Paul,Minnesota (651)222-4642 FAX(651)222-3034 55101 ClInbam Associates Consulting Engineers Project Memorandum Bate: January 6,2003 To: David Halib,Building and Code enforcement,Towtr of Queensbury From: Patrick Davin,Electrical Designer PROJECT: Cadet's-Factory Stores of America,Lake George,NY Comm.No.: 040*5-:52 Re: Drawing corrections The following changes have been made to the drawings to comply with the corrections required Per your comments;hated December 30,2002. Sheet El -Three(3)emergency light fixtures,type`EM'were added to the plan. One(1)fixture located in the stockroom,and two(2)fixtures Iocated on the sales floor. Please see revised drawing for exact location. P'��5utf2 torte.,..NYDoerip�EM9 da9�Stt10na.doe 8200 Nommdate 81W„Suite 500 Minneapotts.MN 55437.1075 Tel.:932-820•1400 FAX;952-820-2760 DohamAssociates.com * TOTAL PRGE.02 TOWN. OF QUEENSBURY 742 Bay Road,'Queensbury, NY 12804-5902' -518-761-8201 December,30,2002 Express Permits 1327 Post Avenue Suite H Torrance,EA 90501 To Whom It May Concern: The-following is a list of items which need to,be corrected-on the Carter plans submitted to this office for review. 1. The stockroom shows a one hour enclosure wall and a three-gizarier'hour fire do.or. .However,it does itot show in.the wall going tight.to the roof'deck or'the,to the,ceiling•above,which creates.a one hour enclosure around the'stockroom. Please make'necessary.changes:to the plans in order to meet.the Building Code requirement of one•ho ur enclosure for the stockroom. 2. Additional.emergency:lights need to_be added to the plans to make sure:-that-all aisles are illuminated as such. It appears:that one.will be added.to the stockroom and one or-two in.the sales floor area where they are lacking. 3.- The handicapped dressing room,must be provided with grab bars that meet the requirements'of the i handicapped Bathroom. This means.a 42 inch grab bar must be provided on.the side and a.36 inch grab-bar on the rear of the walls for the dressing room. 4. There are no.notes on the plans-not drawings that show"a.handicapped accessible.service counter at the cash refs. Please provide,necessary drawings or notes on the plans accordingly. 'Once the'above items have. been-revised on the drawings and resubmitted, this office will review them for comphance.and issue a'building-permifif appropriate:; _ Thank you for your-attention in this matter. Sincerely, TOWN OF QUEENSBURY . . David Hatin,Director - Building and Code Enforcement DH f mg "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO LIVE" SETTLED 1763