Loading...
1.2 1.2 WASTEWATER-SEWERIAPPROVE\Wenner—Replacement-Absorption Field Effluent Lace to Lake and Lace-ETU-In APA-10-17-2022 RESOLUTION APPROVING CARL AND MICHELE WEINER'S APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES RESOLUTION NO.: 12022 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS, Carl and Michele Weiner (Applicants) filed an application for variances from provisions of the Town of Queensbury On-Site Sewage Disposal Ordinance, Chapter 136 to install a replacement septic system with the: 1. Absorption field to be located 63' from the shoreline in lieu of the required 100' setback; 2. Absorption field to be located 1' from the westerly property line in lieu of the required 10' setback; 3. Effluent Sewer Line to be located 4' from the westerly property line in lieu of the required 10' setback; and 4. House Sewer Line to be located 4' from the westerly property line in lieu of the required 10' setback; on property located at 114 Rockhurst Road in the Town of Queensbury, and WHEREAS, the Town Clerk's Office published the Notice of Public Hearing in the Town's official newspaper and the Local Board of Health duly conducted a public hearing concerning the variance requests on Monday, October 17t', 2022, and WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners within 500 feet of the subject property, NOW, THEREFORE, BE IT RESOLVED,that 1. due to the nature of the variances, the Local Board of Health determines that the variances would not be materially detrimental to the purposes and objectives of this Ordinance or other adjoining properties nor otherwise conflict with the purpose and objectives of any Town plan or policy; and 2. the Local Board of Health finds that the granting of the variances is necessary for the reasonable use of the land and are the minimum variances which would alleviate the specific unnecessary hardship found by the Local Board of Health to affect the Applicants; and BE IT FURTHER, RESOLVED, that the Local Board of Health hereby approves the application of Carl and Michele Weiner for variances from the Sewage Disposal Ordinance to install a replacement septic system with the: 1. Absorption field to be located 63' from the shoreline in lieu of the required 100' setback; 2. Absorption field to be located 1' from the westerly property line in lieu of the required 10' setback; 3. Effluent Sewer Line to be located 4' from the westerly property line in lieu of the required 10' setback; and 4. House Sewer Line to be located 4' from the westerly property line in lieu of the required 10' setback; on property located at 114 Rockhurst Road in the Town of Queensbury and bearing Tax Map No: 227.9-1-9, and BE IT FURTHER, RESOLVED, that the Enhanced Treatment Unit (ETU) shall be maintained by the property owner in accordance with the manufacturer's recommendations for the life of the system, and BE IT FURTHER, RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review, and BE IT FURTHER, RESOLVED, that this approval Resolution shall not be effective until 30 days after such notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park Agency during such period. Duly adopted this 17t'day of October, 2022,by the following vote: AYES NOES ABSENT: .169 Haviland Road Queensbury, NY 12804 Hutchins, Engineering Phone:(518)745-0307 Fax:(518)745-0308 September 16, 2022 r (960 Town of Queensbury, Local Board of Health C QU l�, ® 742 Bay Road I � �O Queensbury, NY 12804 ��� 'L 0 Re: Residence of Carl and Michele Weiner �� Z 114 Rockhurst Road, Queensbury Tax Map ID#: 227.9-1-9 Dear Supervisor Strough and Town Board Members: Attached please find a plan and application for septic variance to allow a replacement septic system to be installed for owners Carl and Michele Weiner at the above-referenced residence. We are seeking relief from property line setbacks as well as separation from the absorption field to the shoreline. The proposed treatment system will consist of a FujiClean CE-5 enhanced treatment unit and a 10'W x 301 crushed stone absorption bed with two rows of four 34" traffic rated Infiltrator H-20 chambers. Every effort has been made to provide a high-quality enhanced treatment system and minimize requested variances. We are seeking relief from the absorption field setback to shoreline (63' proposed instead of. required 100'), the absorption field setback to westerly property line (1' proposed instead of required 10'), the effluent sewer line to westerly property line (4' proposed instead of the required 10'), and the house sewer line to the westerly property line (4' proposed instead of the required 10'). We respectfully request to be placed on the board schedule for the upcoming September 26 meeting. Please contact me if you have any questions or if you require additional information. Best Regards, G. Thomas Hutchins, P.E. Cc: Carl and Michele Weiner G.Thomas Hutchins,P.E. thutchins@hutchinsengineering.com ` FT Office Use only SEPTIC VARIANCE &6�wb._,y PermitAPPLICATION permit Fee:.$.'&iz .o Invoice 742 Bay Road,.Queensbury,NY 12804 P:518-761-8256 vuvirinraiiee»'stiury;net' Approvals: T Submittal: 1 (one) original &8 copies of the completed application package PLEASE PRINT LEGIBLY ORTYPE, PLEASE INCLUDE AN EMAIL Section l• Contact Information: Property Owner's): C;arh%.Michele Weiner Owner's Agent: Hutchins Engineering PLLC Address P.O. BOX 2516 _ .. - Address:. 169 Haviland Road Briarcliff Manor, NY 10510 Queensbury, NY 12804 Phone#:, (914)_548-0197 Phone#: 518-745-0307 Email: Email:..thutchins@hutchinsenginepring.com Section 2• Site Information:. Site Address: .114 Rockhurst Road Tax ID#: 227.9-1-9 Directions to Site: from NY-91- N turn right onto Cleverdale Road for 0.8 miles; right onto Rockhurst Rd Section.3• for 0.7 miles; parcel on right side Lake Water Supply Distance froth'ew4gon property to septic system (if applicable) 63 feet Section 4• Is it passible to install a conforming septic system on this property? ❑Yes X'No If YES,please explain and attach a diagram:. .Section 5• Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? QYes ❑No If NO,please explain:_ No Neighboring Wells . Section_6: Is the proposed system to be installed under a parking area? *,Yes ❑No Section 7• Section of the Sanitary Sewage'Ordinance from which you are seeking the variance(i.e.leaching system will be 89 ft., from well in lieu of required 100 ft.): Absorption field to Shoreline:63'proposed Instead of required_100'.(37'of relief requested) Absorption.Field to Westerly Property Line:1'proposed instead of required 10'(9'of relief requested) Septic Variance Application Effluent Sewer Line to Westerly Property Line:4'proposed instead of 10'required(6'of relief requested) House Sewer Line to Westerly Property Line:4'proposed instead of 10'required(6'of relief requested) Section 8• List the names, parcel addresses,and tax map numbers of all adjoining property owners. You may obtain this information from the Town of Queensbury's Assessor's Office: North Name Lamberts Landing LLC Address 117 Rockhurst Road Tax Map ID 2217.9-1-8 South Name Eric Cottrell Address 112 Rockhurst Road Tax Map ID '227.9-1-10 East Name Lake George Address Tax Map ID West Name Lorraine Dickinson Address 11.3 Rockhurst Road Tax Map ID 227.9-1-7 Section 9• OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 114 Rockhurst Rd t/We realize that putting the well,septic tank-o eaciiing syste; Mess than the required 100 feet from the Lake Water Supply may increase the risk of pollution. Owner—Print Name: Carl Weiner iiJwner,=.Signature'.} ra6t)"44, Date: 09t15t22 Section 10: NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: I/We realize that putting the well,septic tank or leaching system less than the required feet from the may increase the risk of pollution. Neighbor/Tenant—Print Name: Neighbor/Tenant-Signature: Date: Septic variance Application Revised December 2021 Section 1l: AUTHORIZATION AND SIGNATURE PAGE. This page includes the Authorization to Act as Agent form, engineering fee disclosure,authorization for site Visits,other permit responsibilities and agreement to provide clocumentation'required. Complete the following if the OWNER is using an Agent: Owner's Name: Carl Weiner Hutchins Engineering PLLC: -Designates: as agent regarding-the Septic Variance for-- Site Address: 11.4 Rockhurst Road Tax Map#.,227.9-1-9 - Eni ineeririg;I.ee-Dlsclosure:>'AppI!cations may be referred to the Town consulting engineer for review of septic design,storm drainage,etc. as determined by the Town Board of Health. Fees for engineei ing review services will be charged directly to the applicant. " Auth6tiza€ion f6r;S4iteVisits By signing this page and submitting the application materials attached herein-,the Owner,'Applicant.and his/her/their agent hereby authorize.the.Town Board of'Health,building and code Enforcement Officers and Town Engineer to enterthe subject properties for the.purpose of reviewing the application submitted. Please Note:,Othier permits may be requiredfor construction or alteration activity subsequent-to approval-by the Town Board of Health. .It is the applicant's responsibility to obtain any additional permits. Off'cial:IVieetine,,Miriutes`Discliisure:.lt is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the-meetings resulting from the application,.and,that the minutes transcribed from those tapes constiteite the officialrecord of all proceedings. If there,is a discrepancy 'between.such.record and the handwritten minutes taken-by the designated stenographer,the handwritten minutes shall'be deemed the official.record. I,the undersigned, have thoroughly read and understand the instructions for'submission;agree to the submission requirements"and completed checklist: " OWNER—PRINT NAME: Carl Weiner, °OWNER SLGNATURE ( itP DATE: 09/15/22 Tl1LYYl 7 r AGENT—PRINT NAME,-. AGENT—SIGNATURE ` ~- DATE.:. - " Septic Variance Application Revised December 2021 Split Rail Fence Off PROP.10'W x3WLCRUSHED —� STONE ABSORPTION BED WITH t2) ROWS OF t6)- 34" WIDEMtAFFIC RATED OPEN -BOTTOM GRAVELLESS CHAMBERS / f One Story Wood Frame House A/C ! %. G q a Concrete Dnve J E M CESSPOOL 227.9 -1- 7 TO a "Ymoo 113 Rockhurst ftaV- Lands of Lorraine Dickinson B:1161 P:58 LAKE WATER SUPPLY PROP. 4" PVC SCH-40 — HOASE SEWER 2% MIN. SLOPE E m CESSPOOL — TO SE REMOVED �s t� 227.9-1-6 CIR5 111 Rockhurst Road Lands NIF of John & Carolyn Swan 8:5107 P:35 LAKE WATER SUPPLY v PVC SCH-40 CLEAN-00 To GRADE mp Lands NIF of Lambert's Landing LLC B:5023 P:173 227.9 -1- 8 LAKE WATER SUPP L r o � NM 17 O Cs CIRF �05 S 7�° 00 00" E —1 S�� CIRF y r �64.00' 1 61t +1 12 Spruce s ' SF 3F • �� SHE � � � i �— CONTROL FENCE 227.9-11 01 I 114 Rockhurst R*ad --10 PI 1 ' Lands of 28" hemlock peck � rl & Michele Weiner t t t VERTICAL DATUM i . rt r `V -1 sZ S� B:4226 P:265 s, , r ;mod `� NORTH AMERICAN VERTTCAL DATUM OF 1929 (NGVD29) Area 1415'8.2 Sq. Feet \ L 0.4 Acres I I o - LA WATER cm qT1 5 •• 9 F' M r i It ( j Fireplace Lake PROP. 4 PVC SCH-40 i EFfWan SEWER \ PROP. W, POLY BASIN l WjRISERFMUvANTI 1 [ ! Georoe Playhouse N PROP. FA3ICLEAN CE-5 - 1��, ENHANCEDTREATMENTANiT � � � � � � .j � PROP. W, P4cSCH-40 ; Sandy HORSE SEWER � � 1 � � I� � � � �0 s ` i Bay �t�A\ t=iti t t; =i=ttt' 1 =t t = Lt } . ltit A �� ' ett �• t t1.:. = t 1 �• � � ; �.� , t t � �� � i 1. � � � PROP. 4" PVC SCH-40 \ \ tt =1l i Sy HORSE SEWER tS.t1."isl i'lt`95t, tii tt t��t�l 1t .1145�i. ':�:.. :. .•:..•.. ••'. .••. -;......''::::.i, INV.13 �Z� Retainm 'wall l t f a :...•':.. .. Conoee Walk Covered +. t•;.. :.,,; :•.� `c t I S Dock I ..,..:: r� o \ Ramp — •� _ � f � Shed • SEWER PROP. AV PNCSCIi-40 � L� ^{ rHOUSE FF. r.!� � ItW, i 3315t 1 44" Zvi ,pl� WL WL W WI- WL WL WL x t 14" aple LMMWATERINTAKE • I # 1 APPROXIMATE LOCATION Concrete j #aft 24 Hemlfk , 30" Hemlock I a I d- PSETSAIac +1 '' f Propane Tanks 12" He � lock o � enerato ///j 1 1 O NM G v Stockade Fence1 Stockade Fence - t t t ti . t ss N 79 ° 00' 00" W 10' ± M Nail 5et in Root ttitj e f t iti}i tt• S ,.— c� O 227 9 -1-10 t z '.:� ; e't t _ ; , }• ; 112 Rockhurst Road M r S Ei�= tti =4t;'=�Z; �t`t�:i Lands NIF of Garage Eric K Cottrell LAKE WATER B:1441 P:102 SUPPLY WASTEWATER SYSTEM PLAN SCALE: 1"--10' GRAPHIC SCALE 5 0 2.5 5 10 20 ( IN FEET ) SEPTIC VARIANCE SUMMARY NYSDOH APPENDIX 75 A WASTEWATER TREATMENT STANDARDS TABLE 2 SEPARATION REQUIREMENTS 1. ABSORPTION REED TO SHORELINE 100' REQUIRED 63'PROPOSED 37 OF RELIEF REQUESTED Z ABSORPTION FIELD TO WESTERLY PROPERTY LINE 10' REQUIRED 1'PROPOSED 9' OF RELIEF REQUESTED 3. EFFLUENT SEWER LINE TO WESTERLY PROPERTY LINE 10' REQUIRED 4'PROPOSED 6' OF RELIEF REQUESTED 4. HOUSE SEWER LINE TO WESTERLY PROPERTY LINE 10' REQUIRED 4'PROPOSED 6' OF RELIEF REQUESTED SITE SOILS DATA TEST PIT TP-1 — 8110122 BY T. HUTCHINS, P.E. AREA OF PROP. ABSORPTION FIELD 0-4" TOPSOIL/GRASS 4-60" MIXED SAND & CONCRETE & BRICK DEBRIS FROM OLD HOTEL NO BOUNDARY CONDITION ENCOUNTERED PERCOLATION TEST PT-1 — 8110122 BY: T. HUTCHINS, P.E. STABILIZED PERCOLATION RAZE: 4 MIN/IN IN BLENDED NATIVE AND FILL MATERIAL SITE LOCATION LOCATION MAP WASTEWATER SYSTEM SETBACK SCHEDULE PROPERTY LINE WELL WATERLINE HOUSE LAKE GEORGE SEPTIC TANK, PUMP STATION, FORCE MAIN, EFFLUENT SEWER 10, 50' 10, 10, 50' ABSORPTION FIELD 10, 100, 10, 20' 100, Dig Safely. New York ■ CaN deton You Dig ■ waft The Rsquked Tune ■ Conflnu tNN ty Response ■ Respect M m woks ■ Dig tW11h Care www.d MAP REFERENCE: BASE MAP INFORMATION FROM "MAP OF A SURVEY MADE FOR CARL AND MICHELE WEINER," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED FEBRUARY 1, 2022. PREPARED BY an Du ,s e. 2 Steves Land Surveyors ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL 189 Haviland Road Queembary, New York 12804 ENGINEER IS A VIOLATION OF NYS (518) M-8494 New York Lie. No. 50135 EDUCATION LAW. TAX MAP # 22Z9-1-9 0 ISSUED FOR SEPTIC VARIANCES 911512022 No. Revisions Date WASTEWATER SYSTEM PLAN prepared for: Carl & Michele Weiner 114 Rockhurst Road Town of Queensbury, County of Warren, State of New York Drawn: JRS/LWD Checked: GTH Scale: NOTED Date: 8/4/2022 169 Haviland Road Queensbury, NY 12804 292001-01-S 1 Hutchins Engineering PLLC (518) 745-0307 Phone 9 9 (518) 745-0308 Fax WASTEWATER SYSTEM DESIGN 3-BEDROOM RESIDENCE WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 330 GPD PRETREATMENT TANK - FUJTCLEAN MODEL CE-5 E.T.U. DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON 6-7 MIN/IN PERCOLATION RATE (BLEND OF NATIVE & FILL SOILS) ABSORPTION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF) = 413 SF 33X ETU. REDUC77ON AREA REQ'D = 276 SF ABSORP77ON BED AREA PROVIDED - 10 x3O' - 300 SF WITH 2 LATERALS OF 4 H2O CHAMBERS WASTEWATER SYSTEM FILL MATERIAL NOTES AFTER REMOVING. ORGANICS TOPSOIL AND DEBRIS, PLACE SYSTEM FILL OVER THE ENTIRE AREA OF PROPOSED ABSORPTION BED AND TAPER AREA. "ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND OR SANDY LOAM NTH IN -PLACE PERCOLATION RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3" 1N SIZE LESS THAN 10% BY WEIGHT SHALL BE FINER THAN 0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE IN THE RANGE OF 0.50mm TO ZOmm. LESS THAN 15X OF THE MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE ABSORPTION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED TO PROVIDE MINIMUM OF 3-FEET BETWEEN BOUNDARY COND17ION AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL SHALL BE INSTALLED THROUGHOUT THE ABSORPTION BED AREA AND TAPER AREAS ABSORPTION AREA SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT PRIOR TO INSTALLA71ON OF ABSORPTION TRENCHES INSTALLER TO NOWFY ENGINEER OF PROPOSED SOURCE OF SYSTEM FILL MATERIAL PRIOR 7D TRANSPORTING TO SITE SYSTEM MATERIAL SPECIFICATIONS 34" WIDE OPEN-SOTTOM GRAVELLESS CHAMBER OPEN -BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH CAPACITY HOUSE SEWER PIPE PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE EFFLUENT SEWER PIPE PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE ABSORPTION BED AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON —WOVEN SEPARATION FABRIC, 7ENCA7F MIRAFI 140N OR EQUIVALENT. STABILIZATION FABRIC STABILIZA71ON FABRIC TO BE WOVEN GE07EX71LE WITH POLYPROPYLENE YARNS, THRACE LINO GIF--300 OR EQUIVALENT. FILL MATERIAL. FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED IN "FILL MATERIAL NOTES." TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORPTION FIELD AREA. SEED AND ESTABLISH TURF. SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS AFTER PLACEMENT OF SYSTEM FILL AND EXCAVATION OF 10' WIDE X 30' LONG ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY TOWN OF QUEENSBURY BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS 10'-0" 0. C. MAX 36" FENCE POST DRIVEN MINIMUM 16" INTO GROUND -SILT STOP EMBED IN GROUND 8" MIN. -....._......... ..:........... ....... - N 8" MIN. w PERSPECTM SOIL BACKF LL SEDIMENT CONTROL FENCE DETAIL NTS STANDARD SPECIFICATIONS FOR SILT FENCE DEFINITION A TEMPORARY BARRIER OF GE07EX77LE FABRIC INSTALLED ON THE CONTOUR ACROSS A SLOPE TO INTERCEPT SEDIMENT LADEN RUNOFF FROM SMALL DRAINAGE AREAS OF DISTURBED SOILS PURPOSE TO REDUCE RUNOFF VELOCITY & TO EFFECT DEPOSITION OF TRANSPORTED SEDIMENT LOAD. APPLICATION — MAXIMUM ALLOWABLE SLOPE LENGTHS CONTRIBUTING RUNOFF TO THE FENCE PLACED ON A SLOPE: 1:2 SLOPE (50%) 25 FT 1:3 SLOPE (33%) 50 FT 1:4 SLOPE (25%) 75 FT 1:5 SLOPE OR LESS 100 FT — MAXIMUM DRAINAGE AREA FOR OVERLAND FLOW SHALL NOT EXCEED 1/4 ACRE PER 100 FEET OF FENCE WITH MAXIMUM PONDING DEPTH OF 1.5 FEET. — EROSION WILL OCCUR AS SHEET EROSION. — CONCENTRATED WATER FLOW SHALL NOT BE DIRECTED TO FENCE. DESIGN CRITERIA ALL SILT FENCES SHALL BE PLACED AS CLOSE TO THE DISTURBED AREAS AS POSSIBLE, WITH A MINIMUM OF 10 FEET FROM THE TOE OF A SLOPE. THE AREA BEYOND THE FENCE MUST BE UNDISTURBED OR STABILIZED. ROADWAY 4" WOVEN STABILIZATION ABSORPTION BED ROAD FABRIC STONE AGGREGATE 36" FENCE POST SILT STOP EMBED IN GROUND 8" MIN. UNDISTURBED GROUND - SENSITIVE AREAS TO BE PROTECTED BY SILT FENCE MAYBE NEED TO BE REINFORCED BY USING HEAVY WIRE FENCING FOR ADDED SUPPORT. - WHERE THE ENDS OF THE SILT FENCE COME TOGETHER, THE TWO ENDS SHALL BE OVERLAPPED, ROLLED TOGETHER AND STAPLED TO PREVENT SEDIMENT BYPASS AT THESE CONNECTIONS FABRIC MATERIAL CRITERIA GRAB TENSILE STRENGTH : 90 LBS ASTM D1682 ELONGATION AT FAILURE. 50% ASTM D1682 CONSTRUCTION SPECIFICATIONS 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE 77ES OR STAPLES. POST SHALL BE STEEL EITHER "T" OR "U" TYPE OR HARDWOOD. Z FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH 77ES SPACED EVERY 24" AT TOP AND MID SECTION. FENCE SHALL BE WOVEN WIRE, 6" MAX. MESH OPENING. J. WHEN TWO SEC71ONS OF FILTER CLOTH ADJOIN EACH 07HER THEY SHALL BE OVER -LAPPED BY 6-INCHES AND FOLDED. FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI IOOX, STABILINKA T140N OR APPROVED EQUIVALENT. 4. PREFABRICATED UNITS SHALL BE GEOFAB, ENWROFENCE OR APPROVED EQUIVALENT. 5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE 4' CHAMBER SPACING INFILTRATOR H-20 CHAMBER PER PLAN ABSORPTION FIELD SECTION NTS Ak 34" CHAMBER WIDTH INFILTRATOR H-20 CHAMBER SECTION NTS NBER HT 4" MIN. TOPSOIL, SEED, MULCH & ESTABLISH TURF -8" MIN. 17EM-4 GRAVEL SUBBASE COURSE ww awiaw ww �iaw a�w �uw ww aw�� way �iaw ww � ww a�i� ww a�iaw ww awuw ww awis ww �uw ww ww awiaw ww awuw ww awuw wa>, awiaw ww awuw ww ww awi� ww ��� ww awuat ww ��� ww awiaw ww ww a�i� ww awuw ww awiw ww w�aw ww wow waw aww wuw aww aw�w ww wiw ww wuw ww wiw waw NTS INSTALL POLYETHYLENE EXTENSION TO GRADE NTH TAMPER RESISTANT ACCESS COVER (NON -TRAFFIC AREAS) 1/4" PER FOOT 2" MIN. SLOPE so 4" PVC SCH-40 HOUSE SEWER CHAMBER 1 ICHAMBER 2 SEDIMENTATION ORIC CONTACT 01AMBER TRATION CHAMBER 59" RURATIQN SALCOR UV DISINFECTION UNIT ELECTRICAL JUNC71ON BOX WITH INDICATORS AND ALARM CONTACTS GROUND LEVEL 4" PIPE TREATMENT PLANT EFFLUENT SECTION A —A INSTALL POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER (NON -TRAFFIC AREAS) INSTALL SALCOR ULTRAVIOLET TREATMENT UNIT 1/8" PER FOOT MIN. SLOPE 4" PVC SCH-40 EFFLUENT 28" DIA. POLY BASIN, 100 GAL 0 AVER & AND GASKET V DISINFECTION SUB — ASSEMBLY HANDLE FOR REMOV) SUPPORT FRAME & GASKET UV LAMP QUARTZ BE TEFLON COVER NOTE. NOT ALL DIMENSIONS TO SCALE SALCOR UV DISINFECTION UNIT NTS 31.5" 1/8" PER FOOT MIN. SLOPE ON 4" PVC SCH-40 EFFLUENT SEWER TO INFILTRATOR CHAMBERS FUJI CLEAN USA MODEL CE-5 ENHANCED TREATMENT UNIT MAINTENANCE CONTRACT NOTE FUJI CLEAN ENHANCED TREATMENT UNIT & UV VESSEL DETAIL A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM NTS OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED FOR SEMI-ANNUAL INSPEC77ON AND SERVICE OF THE FUJICLEAN CE-5 ENHANCED TREATMENT UNIT. TAX MAP # 227.9-1-9 WASTEWATER SYSTEM SETBACK SCHEDULE PROPERTY LINE WELL WATERLINE HOUSE LAKE GEORGE SEPTIC TAMS PUMP STATION, FORCE MAIN, EFFLUENT SEWER 10, 50' 10, 10' 50' ABSORP77ON FIELD 10, 100, 10, 20' 100, Dig Safely. Now York ■ Cail eefve You Dig ■ Walt The Ro*dmd Time ■ Cmff nm WN" Response ■ Respect The woks ■ Dig VRM Can 800-962-7962 www.digsefNTnevrirortoos�