Loading...
2001-796 TOWN OF QUEENSBURY 742 Ba Road eensb NY 12804-5902 518 761-8201 a Y ,.Qu �Y� � ) Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20010796 Date Issued: Monday, February 02, 2009 This is to certify that work requested to be done as shown by Permit Number P20010796 has been completed. Tax Map Number: 523400-309-017-0001-006-000-0000 Location: 50 EAGAN Rd Owner: JOSHUA & THERESA FISH Applicant: THOMAS LINEHAN This structure may be occupied as a: Shed/ Storage Sheds By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, i Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. � TOWN OF QUEENSBURY . 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20010796 Application Number: A20010796 Tax Map No: 523400-309-017-0001-006-000-0000 Permission is hereby granted to: THOMAS LINEHAN For property located at: 50 EAGAN Rd in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: THOMAS LINEHAN Shed/Storage Sheds 1,200.00 50 EAGAN Rd Total Value 1,200.00 QUEENSBURY,NY 12804 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2001-796 164 SQ FT STORAGE SHED AS PER PLOT PLAN SPECIFICATIONS $40.00 PERMIT FEE PAID - THIS PERMIT EXPIRES: Thursday, October 31,2002 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at, e To of eeDsbu , ednesday, October 31,2001 SIGNED BY car ' 1 V J-:-., �' for the Town of Queensbury. Director of Building :Code Enforcement ��` TOWN OF QUEENSBURY s F.T. 4,7 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDI, . PERMIT Permit Number: P20010796 A .plication Number. A20010796 Tax Map No: 523400-309-017-0001-006-000 11100 Permission is hereby granted to: THOMAS LINEHAN For property located at: 50 EAG Al r t in the Town of eensb ,to construct or place Qu �' at the above location in accordance with applicatio ogether with plot . and other information hereto filed and approved and in compliance with the NYS Ur, orm Building Co., and the Queensbury Zoning Ordinance. ype of Construction Value Owner Address: THOMAS LINEHA 50 EAGAN Rd Shed/Storage Sheds $1,200.00 QUEENSBURY,NY - :14 Total Value $1,200.00 NI Contracto r B •der's Name/Addres• Electrical Inspection Agency --••:.--- \ Plans &Specifications 2001-796 164 SQ FT STORAGE S` ` D AS PER PLOT PLAN SPECIFICATIONS $25 PAID ON 4/3/07 $40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday, October 31, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date. Dated at the To„ of Sa, nsb4 esday, October 31, 2001 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement ;' t TOWN OF QUEENSBURY Fee Paid AO. ` ir - BUILDING & CODES DEPARTMENT � , '' Permit #APPLICATION FOR: PORCHES-DECKS- 47675/-97i DOCKS & BOATHOUSES Est. Cost! . DO • A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. PLEASE ANSWER ALL OF THE FOLLOWING: The undersigned hereby applies for a Building Permit to do the following work which will be done in accordance with the description , plans and Specifications suhmitled,:lind such special conditions as may be indicated on the permit. ,�J:Wf) SETS O1 Siiitit-UiAL ,PL%J"NS;"StuttL III SUIIMiiiI WITH THIS APPLICATION. L-_ ------ Owner of Property: iaW,, LC--,ti l 14 fl-n0 P.O. Address 5O E',g-Gy-,J Pc .. Phone # 7y3 -b6g1 Property Location \` \\ -\\ • Tax Map # /137 Z— jo; Subdivision Name (If applicable) A,I,, PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: 793--1o0 1 Name: Tbm T Lr►ei/laJ Address Q Viz%,' IV AD, Phone/ BUILDING SPECIFICATIONS: Type of work to be done: Porch Deck Dock ( Boathouse (Circle ne) S C 1 Size of Structure to be built (square footage) : /2- X16, /Cg 5Q.pi Foundation Material : Width AM Thickness S f-Floor a" Depth of FoOting, below grade: , mono 1— True. p$)4h Size of Posts or Studs: 2-rr x 4-fr x Long Size of Floor Joists: N i9- x x Span Decking or Flooring Material : Cot) a€T-e RECEIVED How will Porch or Deck be fastened to building? CO Nd4/t JOCT 2 4 2001 ihuiodPr -CIUDuN TOWN OF QUEENSBURY If Roof Will Be Installed, Answer Following Questions BUILDING AND CODE Size of Posts or Studs: Li:'x �' .x ri Roof Rafters: '� �. / Long / a x �, Spacing /(2 Vi , Span 1a Roof Trusses (pre-engineered spacing) : /I/(} Span- Type of Roof: Sloped Flat 1e Other (Circle one) r Material of Roof: A oC. 3OLi3�r; E/ ,qS yr, Ffir-L S/ii e/ ZONING INFORMATION: TIWOMPLIWPLANS 'MUST t3E PREPARED ANb ,SUBMITTC , drawn reasonably to scale and attached hereto;'-sTiONi rIg Clearly and ciistinCTiy a=1T—irriffit►i!is, whether existing or proposed and indicate all set back dimensions from property lines. Show location of water supply and location and configuration of septic disposal area. SSUi`�C ill* Size of Property: / ft. x QPD -"P� ft. • Existing building(s) : Size 2.b ft. x N, ft. Size ( ft. x B_O ft.---;;,v;jo/Qfdy, Use of Existing building(s) : (-(o ' e— Proposed structure, distance from property line: Front yard , gc) ft. Rearyard Jr ft.yards ft. and ,p ft. If on corner, setback from side street: ft. DECLARATION To the best of my knowledge and belief the statements contained in this application, together with the plans and specifications submitted, area true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or not, and that such work is autho z d by the owner. DATE: IC)/qi.r /o P SIGNATURE ,o,, O, If Owner, Ow►Yer' s Agency i , Eontractor REVIEWED' BY CODE ENFORCEMENT OFFICER, DATE tildoll SIGNATURE 2 Queensbury wilding & Code Enforcement - Resid tiel F al I section Office No. (518) 761-8256 Arrive: 2 • I D a ID- T•2)) � Date Inspection request received: Inspector's Initials: ` NAME: � P -M #: ['1'1 ?/ ' LOCATION: �T-- ( D T : TYPE OF STRUCTURE: fl 7-2 7 -) ACot ICommei Yes No NIA 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet C 6 inch clearance to sill plate 1U U Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches A -c-)V Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing V Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: • Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/o hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C/O[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised 100405.doc;Revised January 7,2008; Revised 6/26/08 \ Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arri Op /, ": : am/ m . ► Date Inspection request received: Inspector's Initi. / NAME: EN IT#: ¢ LOCATION: S� 1�-- ` D E: TYPE OF STRUCTURE: 3 . �- C=_ 7-) Comments Yes No N/A j Building Number/Address visible from road � 5 / fie`'~ 3� Chimney Height/"B"Vent/Direct Vent Location / Fresh Air Intake tA.. ///Z/O- �C) 3 inch Plumbing Vent through roof minimum 6 inches l 'JIi /` / Roof Complete/Exterior Finish Complete Co plAio L pie C/Pt; Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fuinace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan PL c\p\`!E12 As Built Septic System/Sewer Dept.Inspection Sticker \! Site Plan /Variance required [011 lJ EE- 70 ` ��� f1E Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] KYAk EUE--C- 1Z t L L:\BuiIding&Codes Forms'Building&Codes\Inspection Forms\Residential Final Inspection Form revised 10040 .doc T_ 1-1�FT MGibRL-E \z-%z-Cb �('-3C OA Queensbury Building & Code Enforcement - Residential File-Inspection Of e No.(518) • Arrive: — 'a � 6art(7-2-1.6-7.1 Date Inspection request received: Inspectors Initials: 7,37 G NAME: U (!l-W AA' lti /P IT#: C� "77tc� LOCATION: 5 0 S. n L'DATE: �'—'`1�-- � TYPE OF STRUCTURE: _IJ Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safetyglazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches_x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq. ft.vents Bathroom Fans,if no window Plumbing.fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''Y2"Gypsum �' \ Basement stairs closed rise>4 inches i> t— ' Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer _ �— Duct work Sealed properly �t� Zk. Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan ( :ice As Built Septic System/Sewer Dept.Inspection Sticker �� �, �\�k Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: �4)m/pm Date Inspection request received: Inspector's Initials: QJ1 NAME: Nn4-011/4'45371114744* PERMIT#: �1LOCATION . P l) DATE: TYPE OF STRUCctella C p n � O l� Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs, decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches } Bathroom/Kitchen watertight �`� C�-v Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: V-e1)_-1\/\-1.7Every lev el: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement Dept.of Community Development Arrive am/pm Depart am/pm Town of Queensbury Inspector's Initials 742 Bay Road Queensbury,New York 12804 NAME � 1Z-V•C\r,\S � Pk1•11 PERMIT DATE # (� / 7 LOCATION Sc-7(JRE TYPE OF STRUC N/A YES NO COMMENTS Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake Plumb Vent through roof Roof Complete Exterior Finish Complete Interior/Exterior Railings 30" o 36" Exterior Handrails,balconie.,I. .' g 18 in.or more Interior Handrails stairs bo sides or more risers Grade 2%away from fours..tion 8"clearance to sill plate Gas Valve shut-off expose. egulat• 18"above grade Gas Furnace shut-off within 0 feet r within line of site Oil Furnace shut-off at entran e to • .ce area Furnace/Hot Water Heater op, a Relief Valve(s)installed Headroom,6 ft.6 in.on stairs Basement stairs,6 ft.4 in. Handrail exterior st. b. . si.-s more than 3 risers Interior privacy/trim/doors/main entrance 36" Floor Finish Bathroom/Kitchen watertight Interior Handrails Balconies/Lan•'•g 18 in.or more Railing across window in stairwe s Smoke Detectors: every level • every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire door/door closer Garage fireproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical Site Plan/Variance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy)_ Okay to issue permanent C/O(Certif.of Occupancy) ,-- ' ----------;%i---- - ,.. i ---*.-.77s•-:-.:- .-: - aryl; fibre. , 3Ain.34 - ." 1*----------- --- --- • ''‘,... i ---.. - 1--1_,.. +.4 -, 103 1 i -------4,__ ----'------ -W ''' •‘*". , .30 M. I 1 PI ‘ voiyi. • sofffr • --....._______ ---------"----z------ IL' Fen- --_::::::,_ I 1 sub-trat Aic9 kfier ....„ ....._ ..... _ --___ ....._, ........... ._ , • 1 (iiicfrai -FAci:4 /4 . 7------:::::: if • gi• '/... . fb 0.c , ...„, ------- .. mT.-. • i___: • <----, .A›, , . "i ' • . •e,) tp-tycif,- 1 (ii.2 fiAttl. . ..1111110=-_, ii . ---,------:--'__ -- r 1 1 Da9,100'067.72-s 1.1 I ., . 7.-`9. . - • • I 1 ilh P.513 1 i i 1 z , i • 1 i I ft RECEIVED 1 i , . i f i 1 OCT 2 4 2001 Pe . TOWN OF QUEENSBURY I . I i i 1 BUILDING AND CODE rfm •mr•m/O 1 ' I 1 • 1 1 . I 1 P4 • / , - • , . G 0 / NifiLep . P.r,. ?-1(4- • i , i. . -1- Tkienkev. _cr-u-1—)d- A 1"Ch` rl) Ni • I . - ___---•: i • <,. • . * • • ''—'' i . - IT---_________ • 4 ' i • _ U • Itgf 64! VA • \ . ... HEAVY mesh -: • t . , 7 .1,,, • • 7'i°. • 1(95.7 t • . ‘',''''' . • . i • .1 • • 2 14 . . y • • • .1 . - . • • LOT 1C .1 • - o . 31,344 sq.ft. ‘tre az- 14 0.72 acres N 14) cv in , , • . ._ . . T ... 4 A Box . . • 20.0a. i ?It?' 'S 4 • ititiv.A. . , • ,,,...cb•,c9 12 - • . - . — COpy rttvir ri? WO I tic OD • . USZ i P.0404 1 att.notv , , •ftiiiiiii-4,,/ ., f / I • 1 ,-„oc (506 • e I . '8 / a- .V1:111/4::c........... ..)coDE:B:L6C11‘1\75:: Y:Ar'C‘' , ,r nuitV3's.. elsf"\\'g\ka sr 1/./4,77, i •et . 05,1\10,: - A/7,,. • v . \,?Ac...,.. , oc\,-,K up/ 0"......... w .= .. . . • H • i.,, ,....._, • 1 htf • Tr RP HCE • . ,• FOF . BM TOVAN OF 'QUF.F...:t1- .1'1-- 1/ AND GER fN51 • a__ '1,' DING & .eicros' ' 0E12 , ,, • _ /rit,a_, a; • VIEW. D BY , If\ "5/ s )/1 m. ........... : . DA . • 17 0 V t _ .____ DAT] e . GER' , . . • . „ i