CC-0005-2022 Office Use Only
ADDITION/ALTERATION PERMIT Permit#: c C- OG D`15-'z0zz
to APPLICATION Permit Fee:$ Zl•��
Town ofQueensbury
742 Bay Road,Queensbury,NY 12804 oice#:
P:518-761-8256 www. ue ensbury.nel
E a V
DI od Zone? Y N . Reviewed
Project Location: 63 Quaker Road JAN 0 5 2022
Tax Map ID#: 296.18-1-5 TOWN OF QUEEN
IRY. .
BUILDING& - _ ivisi n Name:
PROJECT INFORMATION:
TYPE: Residential X Commercial, Proposed Use:Dog Grooming
_Single-Family —Two-Family _Multi-Family(#of units ) _Townhouse
Business Office _Retail _Industrial/Warehouse _Garage (#of cars_)
Other(describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 1st floor: 2632
2nd floor: 2nd floor:
3rd floor: 3rd floor:
Basement(habitable space): Basement(habitable space):
Total sq ft: Total sq ft:V, 3 v
Scope of work to be done:
Removing existing dog daycare areas and creating individual dog grooming workspaces/suites.
Addition/Alteration Application Revised January 2021
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): Matthew Wing
Mailing Address, C/S/Z: 22 Fox Hollow Lane, Queensbury/NY/12804
Cell Phone: 607 ) 437-1896 Land Line: � )
Email: gbmelectticalco@outlook.com
• Primary Owner(s):
Name(s): Angie Sherman
Mailing Address, C/S/Z: 63 Quaker Road, Queensbury/NY/12804
Cell Phone: 518 ) 932-5538 Land Line: �)
Email: angierobinsherman@gmail.com
r-1 Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contact Name(s): Matthew Wing
Contractor Trade: Electrician
Mailing Address, C/S/Z: 22 Fox Hollow Lane, Queensbury/NY/12804
Cell Phone: 518 ) 615-4931 Land Line: � )
Email:
"Workers' Comp documentation must be submitted with this application"
• Arch itect(s)/Engi nee r(s):
Business Name: Concepts &Designs
Contact Name(s): Mike Marley
Mailing Address, C/S/Z: Queensbury, NY 12804 — I b 1 ei1k-,,1 b\(,
Cell Phone: 518 ) 744-8245 Land Line: � )
Email: maneymi _gmail.com
Contact Person for Compliance in regards to this project: Matthew Wing
Cell Phone: 518 ) 615-4931 Land Line: � )
Email: gbmelectricalco@outlook.com
1
Addition/Alteration Application Revised January 2021
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ $90,000
2. Source of Heat(circle one):_Gas _Oil _Propane _Solar X Other (Existing RTU)
Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application
3. Are there any structures not shown on the plot plan? YES X NO Explain:
4. Are there any easements on the property? YES X NO
SITE INFORMATION:
• Is this a corner lot? _YES X NO
• Will the grade be changed as a result of the construction? _YES X NO
• What is the water source? X PUBLIC _PRIVATE WELL
• What type of wastewater system is on the parcel? X SEWER _PRIVATE SEPTIC
DECLARATION:
1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. 1 certify that the application, plans and supporting materials are atrue and a complete statement and/or description
of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws
and ordinances, and in conformance with local zoning regulations.
5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: Matthew Wing
SIGNATURE: 4A A Q,,k I A DATE: 01/05/2022
Addition/Alteration Application Revised January 2021
FIRE MARSHAL'S OFFICE
Tozun of Queensbunj
742 Bay Road, Queensbunj,NY 12804
"Home of Natural Beauty... A Good Place to Live "
Classy Clips _
63 Quaker Road FILE COPY'
CC-0005-2022
1/5/2022
2632 sf
The following comments are based on a review of-submittals:
• Verify fire extinguisher location to be-discussed with.contractor
Location of exit/Emergency lighting appear adequate. Function test will be
required
• Lock/ latches shall comply with Chapter 10 of 2020 IFC.
• Verify paths of egress
• Verify storage
• Verify clearances.to electrical service panels
• CO detection is identified on drawings
e Knox Box is required, Model 3200, along with an.entry key to the store,
• Verify Truss ID
Michael J Palmer
Fire Marshal
742 Bay Road
Queensbury NY 12804
flremarshal@queensbury.net
Fire M a r.s h a l 's Office Phone: 518-761-8206 - F a z: 518-745-4437
firemarshal@gueensbuW.net zmmo.queensbiny.net
{ 7
l
COMcheck Software Version COMcheckWeb
Envelope Compliance Certificate
Project Information �/J
Energy Code: 2020 New York State Energy Conservation Const n 1E 0 v 15
Project Title: Classy Clip Remodel
Location: Glens Falls, New York JAN 0 5 2022
Climate Zone: 6a
Project Type: Alteration TOWN OF QUEENSBURy
BUILDING& CODES
Construction Site: Owner/Agent: Designer/Contractor:
Mark Plaza,63 Quaker Road Angie Sherman Matthew Wing
Queensbury, New York 12804 Classy Clip GBM Electric LLC
63 Quaker Road 22 Fox Hollow Lane
Queensbury, New York 12804 QUEENSBURY, New York 12804
5189325538 5186154931
angierobinsherman@gmail.com gbmelectricalco@outlook.com
Building Area Floor Area
1-Dog grooming(Office):Nonresidential 2632
Envelope Assemblies
Envelope : r . .- assemblies specified
296.18-1-5 CC-0005-2022
Classy Clips
63 Quaker Rd
Interior Alterations 2632 s.f.
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 1 of 9
1 1
1
COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Information
Energy Code: 2020 New York.State Energy Conservation Construction Code
Project Title: Classy Clip Remodel
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Mark Plaza,63 Quaker Road Angie Sherman Matthew Wing
Queensbury, New York 12804 Classy Clip GBM Electric LLC
63 Quaker Road 22 Fox Hollow Lane
Queensbury, New York 12804 QUEENSBURY, New York 12804
5189325538 5186154931
angierobinsherman@gmail.com gbmelectricalco@outlook.com
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts/ft2 Watts
1-Common Space Types:Lobby-General 382 1.00 382
2-Common Space Types:Office-Enclosed 1749 0.93 1627
3-Common Space Types:Corridor/Transition <8 ft wide 344 0.66 227
4-Common Space Types:Restrooms 50 -'0.85 42
5-Common Space Types:Laundry/Washing Area 107 0.43 46
Total Allowed Watts= 2324
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description /Lamp/Wattage Per Lamp/Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Common Space Types: Lobby-General (382 sq ft.)
LED:6"Recessed Cans: LED Other Fixture Unit 13W: 1 8 12 97
Common Space Types: Office- Enclosed (1749 sa.ft.)
LED:2x2 LED Flat Panel: LED Panel 33W: 1 38 38 1444
Common Space Types: Corridor/Transition <8 ft wide (344 sq ft)
LED: 6"Recessed Cans: LED Other Fixture Unit 13W: 1 9 12 109,
LED: Hallway Pendants: LED A Lamp 9W: 4 2 36 72
Common Space Types: Restrooms (50 sa.ft.)
LED:Fan/Light Combo: LED Other Fixture Unit 40W: 1 1 40 40
Common Space Types: LaundryMlashing Area (107 sq.ft.)
LED:2x2 LED Flat Panel: LED Panel 19W: 1 2 23 46
Total Proposed Watts= 1808
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 2 of 9
t
Interior Lighting PASSES
Interior Lighting Compliance
Statement
Compliance Statement. The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2020 New York State Energy Conserva ion Construction Code requirements in
COMcheck rVe��rsion COMcheckWeb and to comply with a y a licab ma da o requirements listed in the Inspection Checklist.
,44Name-Title f SlIgnMare Date
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 3 of 9
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2020 New York State Energy Conservation Construction Code
Project Title: Classy Clip Remodel
Project Type: Alteration
Exterior Lighting Zone 2 (Neighborhood business district(LZ2))
Construction Site: Owner/Agent: Designer/Contractor:
Mark Plaza,63 Quaker Road Angie Sherman Matthew Wing
Queensbury, New York 12804 Classy Clip GBM Electric LLC
63 Quaker Road 22 Fox Hollow Lane
_ Queensbury, New York 12804 QUEENSBURY, New York 12804
5189325538 5186154931
angierobinsherman@gmail.com gbmelectricalco@outlook.com
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/ Wattage (B X C)
Back Entrance(Plaza area) 360 ft2 0.1 Yes 36
Total Tradable Watts(a) = 36
Total Allowed Watts= 36
Total Allowed Supplemental Watts(b)= 400
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID_: Description/Lamp/Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Back Entrance (Plaza area 360 ft2)•Tradable Wattage
LED:LED Wall Pack: LED Other Fixture Unit 36W: 1 1 35 35
Main Entrance (Entry canopy. 120 ft2)• Exempt; Non-tradable Wattage
Total Tradable Proposed Watts= 35
Exterior Lighting PASSES
Exterior Lighting Compliance
Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans,specifications, and other calculations submitted with this permit application.The proposed exterior lighting
systems have been designed to meet the 2020 New York State Energy Conservation Construction Code requirements in
COMcheck Version CORM,che/ckWeb and to comply with any p'cab] mandate requirements listed in the Inspection Checklist.
Name-Title Sig Nature v VDat
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 4 of 9
COMcheck Software Version COMcheckWeb
Mechanical Compliance Certificate
Project Information
Energy Code: 2020 New York State Energy Conservation Construction Code
Project Title: Classy Clip Remodel
Location: Glens Falls, New York
Climate Zone: 6a
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
Mark Plaza,63 Quaker Road Angie Sherman Matthew Wing
Queensbury,New York 12804 Classy Clip GBM Electric LLC
63 Quaker Road 22 Fox Hollow Lane
Queensbury, New York 12804 QUEENSBURY, New York 12804
5189325538 5186154931
angierobinsherman@gmail.com gbmelectricalco@outlook.com
Mechanical Systems List
QuantitySystem Type & Description
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building
plans,specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been
designed to meet the 2020 New York State Energy Conservation Construction Code requirements in COMcheck Version
COMcheckWeb and to comply with any applicable manda r uire ents listed i the Inspection Checklist.
Name-Title Signature Date
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 5 of 9
C
COMcheck Software Version COMcheckWeb
Inspection Checklist
Energy Code: 2020 New York State Energy Conservation Construction Code
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
.Section �:
# -Plan Review Comphes? ` Comments/Assumptions
C103.2. ;Plans,specifications,and/or " .❑Complies ;Requirement will be met. `
[PR4]1 !calculations provide all information ;❑Does Not
iwith which compliance can be ;❑Not Observable;
:determined for the interior lighting
:and electrical systems and equipment :❑Not Applicable ;
and document where exceptions to
.the standard are claimed. Information
provided should include interior
;lighting power calculations,wattage of;
•bulbs and ballasts,transformers and
control devices.
C103.2 ;Plans,specifications,and/or !❑Complies ;Requirement will be met.
[PR8]1 :calculations provide all information ;❑Does Not i
;with which compliance can be
!determined for the exterior lighting ;❑Not Observable
and electrical systems and equipment :❑Not Applicable
;and document where exceptions to ;
.the standard are claimed. Information 1
provided should include exterior
;lighting power calculations,wattage of
bulbs and ballasts,transformers and
;control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 1,21IMedium Impact(Tier 2) 31 Low Impact(Tier 3)
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 6 of 9
' .
`
ile
C405.2.2. :Spaces required to have light- ElComplies ;,Requirement will be met.
2 reduction controls have a manual �E]Does Not
[EL22]1 control that allows the occupant to I I
;E]Not Observable
;reduce the connected lighting load in
;a reasonably uniform illumination
C405.2.1, !Occupancy sensors installed in ZComplies ;Requirement will be met.
C405.2.1. :classrooms/lecture/training rooms, UDoes Not
I :,conference/meeting/multipurpose
[EL1811 I rooms, copy/print rooms, �E]Not Observable:
tlNot Applicable
�Iounges/breakrooms,enclosed offices,
open plan office areas, restrooms,
storage rooms,locker rooms,
:warehouse storage areas,and other
ispace
by floor-to-ceiling height partitions.
FReference section language
1 C405.2.1.2 for control function in
:warehouses and section C405.2.1.3
,for open plan office spaces.
C405.2.1. .;Occupancy sensors control function in Dcomplies Exception: Requirement does not apply.
2 ;warehouses: In warehouses,the 1EIDoes Not
[EL19JI ;lighting in aisleways and open areas is;
1controlled with occupant sensors that �[]Not Observable:
:E]Not Applicable
iautomatically reduce lighting power
:)by 50%or more when the areas are
Wrioccupied.The occupant sensors
�control lighting in each aisleway
:independently and do not control
ilighting beyond the aisleway being
I controlled by the sensor.
C405.2.1. I Occupant sensor control function in !,[]Complies i Exception: Requirement does not apply.
3 !open plan office areas: Occupant PDoes Not
[EL2011 ,sensor controls in open office spaces :.[]Not Observable:,
:F—]Not Applicable
configured so that general lighting can I
ibe controlled separately in control
!zones with floor areas<=600 sq.ft.
:within the space,2)automatically turn
,,off general lighting in all control zones
iwithin 20 minutes after all occupants
;have left the space,3)are configured
so that general lighting power in each
:control zone is reduced by>=80%of
�the full zone general lighting power
:within 20 minutes of all occupants
leaving that control zone,and 4)are
1,configured such that any daylight
:responsive control will activate space
:general lighting or control zone
:general lighting only when occupancy
�for the same area is detected.
C405.2.2,7 JEach area not served by occupancy ElComplies ;Requirement will be met.
!switch controls and functions detailed
:.ElNot Applicable
'
1 High Impact(Tier 1) 1-2.1 Medium Impact(Tier 2) Low impact ffier�3)
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: page 7nr 9
. .
Section,
C
Ii - Cornmentg/Assurnp lqns-
kegID',
C465.2.3,:1 Daylight zones provided with ',L]Complies Exception: Requirement does not apply.
t405.2.3. I individual controls that control the CIDoes Not
11"_ ilights independent of general area
:DNot Observable:
C405.2-3.. lighting.See code section C405.2.3
2,,'�_,' Daylight-responsive controls for :,E]Not Applicable
,[EL23]2 ,applicable spaces,C405.2.3.1 Daylight:
I responsive control function and
,section C405.2.3.2 Sidelit zone.
C405.2.4 ;Separate lighting control devices for Zkomplies Requirement will be met.
[EL26]1 :specific uses installed per approved ;E]Does Not
lighting plans.
�MNot Observable:
:E]Not Applicable
---!
C405.2.4 !,Additional interior lighting power IE]Complies Requirement will be met.
[EL27]1 'allowed for special functions per the :EJDoes Not
;approved lighting plans and is
;automatically controlled and !E]Not Observable;
:separated from general lighting. �E]Not Applicable
C405.2.5 i Manual controls required by the bComplies Requirement will be met.
[EL28]1 ;energy code are in a location with ;E]Does Not
!ready access to occupants and
i;located where the controlled lights are,:E]Not Observable;
;visible, or identify the area served and;,E]Not Applicable
;their status.
C405.2.6 ;,Automatic lighting controls for exterior;[]Complies ;Requirement will be met.
[EL30]1 :lighting installed.Controls will be :,E]Does Not
:daylight controlled,set based on I
:business operation time-of-day, or :E]Not Observable:
reduce connected lighting >30%. :E]Not Applicable
C405.3 ',Exit signs do not exceed 5 watts per QComplies :Requirement will be met.
[EL6]1 :face. PDoes Not
:E]Not Observable:
1EINot Applicable
Additional Comments/Assumptions:
I I High Impact(Tier 1) 1:'2 1 Medium Impact(Tier 2) 3:1 Low Impact(Tier 3)
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 8 Of 9
t 1'56ctlofi
Flnallnspection Complies? Comments/Assumptions
ell
C303.3; Furnished O&M instructions for IlComplies ;Requirement will be met.
C408.2.5. systems and equipment to the IlDoes Not
2 building owner or designated
F117]3 representative. UNot Observable:
:[]Not Applicable
C405.4.1 Interior installed lamp and fixture ',-EIComplies ;See the Interior Lighting fixture schedule for vat.ues.
[FI18]1 Ilighting power is consistent with what :,E]Does Not
�,is shown on the approved lighting I I
:plans,demonstrating proposed.watts T]Not Observable;
are less than or equal to allowed :E]Not Applicable
watts.
;See the Exterior Lighting fixture schedule for values.
C405.5.1 Exterior lighting power is consistent ,;E]Complies
[FI19]1. "with what is shown on the approved UDoes Not
,lighting plans,demonstrating
proposed watts are less than or equal UNot Observable;
t1Not Applicable
to allowed watts.
C408.'2.5. Furnished as-built drawings for Tkomplies ;Requirement will be met.
1,: _' electric power systems within 90 days TIDoes Not
ftl16j3 Of system acceptance. I
:E]Not Observable 1
[]Not Applicable
C408.3 ;Lighting systems have been tested to !E]Complies 'Requirement will be met.
[F13313 ensure proper calibration, adjustment, UDoes Not
programming,and operation.
:[]Not Observable:
iElNot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) J'-2 Medium Impact(Tier 2) 1 3 ILow impact(Tier3)
Project Title: Classy Clip Remodel Report date: 01/05/22
Data filename: Page 9 of 9
RX Date/Time 05126/2022 09:32 15182731202 P.002
May, 26, 2022 9;03A "MDIA- No, 9373 P. 2
MIDDLE DERARTM-ENT INSPECTION AGENCY� M.
4i5�W�&that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being In accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner_ Classy Clips Dog GroomingDate:
05l10/2022
Occupant: 1 st Floor Fit-Up Location
63 Quaker Rd.
Occupancy Queensbury,Warren Co.NY
�on-Residential
Applicant:
GBM Electrical .. .
Aftn:Matthew Wing
22 Fox Hollow Ln, W
Queensbury NY 12804Joseph A.Holmes
No.
Equipment:
1 -100 Amp Sub Panel; 12-Switches;'74 Receptacles; 64-Fixtures; 2-30 Amp Receptacles;2-Vent Fans; 13-
Emergency Lights;4-ExitlEmergency Combos.
This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and
Wove and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership
inspection, No warranty Is expressed or implied as to the mechanical safety,ern- of the property indicated above,this certificate shall be immediately null and void.
oency or fitness of the equipment for any perttcular purpose. This certifioste shalt In the event that this certificate becomes invalid based upon the above conditions,
be valid for a period of one year from the above noted date, Should the electrical this certificate may be revalldated upon relnspeetion by Middle Department
system to which this certificate applies be altered in any way.including but not limit- Inspection Agency,Inc. An application for Inspection must be submitted to Middle
ed to,the Introduction of additional electrical equipment and(oe the replacement of Department Inspection Agency, Inc,to initiate the inspection and revalidation
any of the components installzd as o}the above noietl date,this ceRNigts shJl he process. A fee Will be charged for this service.