Front Elevation PROPOSED SIGNAGE TABLE
❑AREA --- --- — — -- FEDERAL.
SIGN SCHEDULE
O USE VA► IIANCE NO SYM DESCRIPTION - _ ��SIGN AREA �OUAN TOTAL AREA HEATH
V 1�lr --r-
PROPOSED CHILI'S WALL SIGN 18.0 S F t 180 S.F.
—OS-- -- -- ----- i- - ------- ---..
❑ C" L' PROPOSED CHILI PEPPER 30.0 S F 1 { 30.0 S.F. SIGN COMPANY
( f PROPOSED TO GO SIGN 5.3 S.F. 1 5.3 S.F. www.FederaIHeatti.com
C> PROPOSED PEPPER S SIGN 1 38.1 S.F. 1 38.1 S.F. 2300 North Highway 121
PROPOSED TOTAL AREA: 91.4 S.F. Euless,Texas 76039
(8171 685-9077 (800)527-9495
5" DEEP BRINKER RED PRE-FINISHED ALUMINUM Fax(817)685-9103
CHANNELS ON LETTERS& PEPPER BOTTOM,WITH CLEAR otrerorficeLocatlons
ACRYLIC FACES 5 RED VINYL APPLIED TO SECOND SURFACE.
RED TRIM CAP RETAINERS. Oceanside-Las Vegas-Columbus
Willowbrook-Knoxville-Jacksonville
PEPPER STEM TO BE BRINKER GREEN PRE-FINISHED ALUMINUM Houston-San Antonio-Corpus Christi
CHANNEL,W/CLEAR ACRYLIC FACE& #76 GREEN VINYL Milwaukee-Indianapolis-Atlanta
APPLIED TO SECOND SURFACE. Tampa-Daytona Beach
GREEN TRIM CAP RETAINER. Building Quality signage For American Business
0? INTERNALLY ILLUMINATED WITH WHITE LED LIGHTING.
POWER SUPPLY/J-BOX BEHIND WALL, -
i Added ST to signs 9/11/08 RG
Fabricated 5., z New elevations proto 15 11/18/08 RG
C �1� Aluminum 115 VAC Power SuPPty
' Channel-----------
letter w/Trim Cap (7.5VOC DR 24VOC Depending on
Colors As Noted. ` LED Color-Mount in Dry Area Only)
Total: 2.0 Amps AWL Wire From Power Supply s
To LED Connector Inside -
LED Illuminated ------------------ Each letter. G
(18 AWL Wire For Leger Jumps)
(1) 120V 20A Circuit Required.
S/F CHANNEL LETTER SET ELEVATION ALL BRANCH CIRCUITS SHALL BE A Lount Re1D JOE DUNAVAN
Z111,1111, • Metal Pass-Thru In Wall For --- ---- --- - ---
,SIGN TypEfi!■ I t DEDICATED TO SIGNS(INCLUDING ACryliC FaCe------------••-- -- -•--•---- power Supply Leads
GROUND AND NEUTRAL)AND SHALL W/Vinyl -----Electrical To Power Supply In
SCALE: 1/2" = 1 NOT B
'-O" (1)REQ'D E SHARED WITH OTHER LOADS. Flexible Conduit. Project N'anagec PAUL/(ARL1N
< J-Box W/Approved Cut-Off Switch
Non-Corrosive--•---------------- - To Be Visible From LED Power Supply. Drawn By R. GONZALEZ
Electrical To Box And Final Hook-up
Installers:e-s:e o not take direction from Actual Square Footage (of shape): 18,0 S.F. Total Type Hardware Byc.C.Electrician.
Brinker on-site operations. Please call your '�
Contact at Federal Heath Sign Company ...........bracing Behind Wall As Required Proiecr i Location
(800-527-9495)with any questions on
signage placement or if you have been SECTION DETAIL- FACE LIT ILLUMINATED WALL LETTERS
asked to modify the signage installation in N.T.S.
any way that is different from what is shown SIGN TYPE C ' Is
on the approved Federal Heath drawing.
-- -- C-52.5-CLS-LED Illuminated SIGN T-PEO
PROT015 FLIP
-ICN'TYPE S/P FIBERGLASS PEPPER FIT 9&Quaker RD
C-11-R-TGP-N(TOP CHAIN MOUNT)
_z Queensbury, IVY 12801
` .--- Il Underwriters ELECTRICAL TO USE U-L.USTED
.L-Laboratories Inc.
COMPONENTS AND SfiALL MEET
--- ALL N.E.C.STANDARDS.
4. . - .1..._..� .�
`----- -'----' >1w----- This original drawing is provided as ,cart of a
i planned project and is not to be exhibited.copied or
€ reproduced without the written permission of
Federal Heath Sign Company LLC- or its
authorized agent. *2007
- Colors Depicted In This Rendering May Not Match l i i ' - v< = ----'- - ' Actual Material Finishes Refer To Product Samples
¢ f _
w- 1 For Exact Color Match.
s
Job Nulrber: 23-56959-00
f
E
File Name
}
,
Date: 8/227/08
z ' Sheet Number: a
FRONT ELEVATION
Scale: 1/8" = 1'4' Design Number, 23-56959132