DEMO-0657-2022 Office Use Only
4
&- m-o
DEMOLITION APPLICATION Permit#:t;�C
Permit Fee:$ L�5
7'oivn ofQuccnsbury Invoice#:
742 Bay Road,Queensbury,NY 12804
P:518-761-8256 www.clueensbury.net Flood Zone? Y /pY ) Reviewed B -
10
Demolition Location.�\ T A IP $ Tax Map ID#:., 1/0
**AN ASBESTOS REPORT IS REQUIRED WITH ALL
DEMOLITION APPLICATION SUBMISSIONS**
DEMOLITION INFORMATION:
1. Where will demolition material be disposed? H I Q A hn MI6 LL6 w
2. Type of structure to be demolished: D E C [E 0 / IE
a. Residence DC d. Storage Building
b. Garage e. other: OCT 2 6 20�Z
c. Business
3. What type of utilities are connected to the structure: TO UILD G W N OF U& CODIeS�Y
a. Gas f. Well-Water Pump —
b. Fuel Oil g. Public Sewer�_ 1� ALL
( v 6
c. Propane h. Other V80i D1SG6NP6GTeb
d. Electric i. None
e. Public Water
4. Have ALL utilities (water,electric, etc.) been disconnected? Yes No
ADDITIONAL INFORMATION:
1. Two inspections are required: an inspection to determine that utilities are
disconnected, and a final inspection after the structure is removed and the site is
cleaned up and graded.
2. Twenty-four (24) hour notification is required for inspections.
3. Workers' Comp insurance information is required to be submitted with this application.
Declaration: I acknowledge that no structure(s)will be removed from the parcel until the demolition application has
been reviewed and approved by the Town of Queensbury Building&Code Enforcement and Zoning Departments and a
permit has been issued.
I have read and agree to the above:
PRINT NAME: 6SE H Kc.l
SIGNATURE: DATE: 16I L0 2-
Demolition Application Revised June 2022
CONTACT INFORMATION: PLEASE'PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): FooT N iLJ-S StXIL0601.S
Mailing Address, C/S/Z: 9 MbLkt-tAtMs t0Lr Lkeeps8Lk N`1 fZQ�Y
Cell Phone: Qs tF)Ii t-II15 Land Line:
Email: Foot U tins&L ►Ll5C&S W-(Q G4mNA t L, (A r1\
• Primary Owner(s):
Name(s): 5A MC AS A f P L-t cA+sT
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
Check if all work will be performed by property owner only
• Contractor: (List all additional contractors on the back of this form)
Contact Name(s): S A mer AS A P Pt,t �T
Contractor Trade:
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
**Workers' Comp documentation must be submitted with this application**
Contact Person for any questions regarding this project: 7�0 E LEA(.-d
Cell Phone: CS111011 1 -1133 Land Line:
Email: 50ol A ILLS bLtt L D 6!6 N`( G G-mA1 L, cA►,n
Demolition Application Revised June 2022
: 18 Blackberry Lane
k..., L.EARVU' Queensbury, NY 12804
S I �fSPEGTtC7 roan@clearvuinspections.com
t°w[
518.832.9213
FEDCOVE
M copy
6 2022
TOWN OF QUEENSBURY
BUILDING& CODES
Pre-Demolition. Asbestos . Survey
TOWN OF QUEENSBURY 0 o O O
BUILDING DEPARTMENT
BFSed on our limited examination,compliance 3 3 O 0
with our comments shall not be construed as
indicating the plans and specifications are in o = O
full compliance with the Building Codes of TOWN OF QUEENSBURY 0 r �`
New York State.
BUILDING & CO S PT. °
Reviewed B : � p0
c
Date: `� 2 p rn
a M
PROJECT NUMBER PREPARED FOR ! co Im
10141 Foothills Builders fD A V
9 mountainside Drive N
SITE LOCATION Queensbury, NY 12804
N
House&Garage N
80 Main street PREPARED BY
Queensnury, New York 12887 Ryan Wild
18 Blackberry Lane
Queensbury, New York 12804
'I 1
Foothills Builders,80 Main Street,Queensnury,New York,12887
Executive Summary
Asbestos-Containing Material Field Survey
House&Garage
80 Main Street
Queensnury, New York, 12887
I. SUMMARY OF FINDINGS
On August 29, 2022,an asbestos-containing material (ACM)field survey was conducted at 80 Main Street located in
Queensnury, New York(Site).The site was inspected to determine the presence of ACM in preparation for demolition;
the house was mostly gutted on arrival.The ACM survey was performed at the request of Foothills Builders.
A summary of asbestos-containing materials is provided in the following table. However,this report should be read in
its entirety, including detailed information that is contained in other sections and appendices.A total of 61 samples
were collected from 25 suspect homogenous materials.
Summary Table of Asbestos-Containing Materials
Sampie t#�,-„ S ace..Nairie Numerical itesuit Material-Gate o, ¢ :rFria#�ili.
NO ASBESTOS DETECTED
***Electrical was on during the survey and electrical insulation was not sampled***
Following the introduction, a table of ACM grouped by homogeneous areas is included in Appendix A of this report.A
table presenting those materials sampled which did not contain asbestos can be found in Appendix B of this report.A
complete listing of all suspect materials sampled is provided in Appendix C of this report.The original chain of custody
& laboratory analytical reports are located in Appendix D of this report.
Page 2 of 6
Foothills Builders,80 Main Street,Queensnury,New York,12887
INTRODUCTION GENERAL INFORMATION
ClearVU Inspections was retained by Foothills Builders to conduct a pre-demolition survey.All methods and
procedures employed in this survey were done in accordance with NYSDOL(New York State Department of Labor),
OSHA(Occupational Safety and Health Administration),and USEPA(United States Environmental Protection Agency)
regulations and protocol.
The information contained in this report has been collected in accordance with existing regulations. If this document
is to be utilized for bidding quotations, it cannot be held binding and must be field verified by those contractors
submitting bids.
PURPOSE
The purpose of this survey was to identify,document, and measure specified asbestos-containing materials in this
building,which may be disturbed during renovation/demolition/rehabilitation activities.Samples were collected of
suspect accessible asbestos-containing building materials.Should any materials be encountered that are not
identified in this report,they should be assumed asbestos containing until a representative number of samples are
collected to document these materials as non-asbestos containing.
LIMITATIONS&SCOPE OF SERVICES
Provide a visual inspection of all accessible building components to determine the presence of suspect materials.The
inspector physically assessed,quantified and conducted bulk sampling as required of suspect ACM (Asbestos
Containing Materials)which were accessible or exposed.This report represents the locations and quantities of ACM
(Asbestos Containing Materials) present as well as all sampled materials that tested negative for the presence of
asbestos and their locations. Bulk sample analysis was performed by a participating New York State Department of
Health Environmental Approval Program (NYSDOH-ELAP)certified laboratory. Buildings where power is connected,
electrical wire sheathing could not and was not sampled.
SAMPLING METHODOLOGY
During the visual inspection process, an inventory of suspect materials similar in appearance and composition was
created and grouped into homogeneous sampling areas.A homogeneous area is defined as a surfacing,thermal or
miscellaneous material that is uniform in texture, age,and appearance.A representative bulk sampling plan was
created in accordance with current USEPA(United States Environmental Protection Agency) requirements and
guidelines. Bulk samples were then collected of suspect ACM (Asbestos Containing Materials)to identify the presence
of asbestos.
There are a number of materials,which rarely contain asbestos and are not specifically addressed in this report.Such
materials include but are not limited to metal,glass, rubber,cinderblock and mortar.
LABORATORY METHODOLOGY
The friable bulk samples were analyzed by Polarized Light Microscopy(EPA Interim Method:Appendix A to Subpart F
40CFR Part 763) at magnifications ranging from 10x to 400x, and New York State Department of Health ELAP Item
Number 198.1(Polarized Light Microscopy Methods for Identifying and Quantitating Asbestos in Bulk Samples).The
estimated phase abundances are provided in weight percent and are accurate to within 10 to 15 percent of the
amount reported.These methods are sensitive to the detection of asbestos to less than one percent.
Page 3 of 6
Foothills Builders,80 Main Street,Queensnury,New York,12887
All non-friable organically bound (vinyl flooring,caulking,etc.) bulk samples were analyzed by New York State
Department of Health ELAP Item Number 198.4(Transmission Electron Microscopy Method for Identifying and
Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples). NOB samples were first reduced by the
Gravimetric Matrix Reduction Method to determine if greater than one percent of material remained. If greater than
one percent of the NOB material remained by weight,the sample was analyzed by Polarized Light Microscopy by New
York State Department of Health ELAP Item Number 198.6 to determine if it contained greater than one percent
asbestos.
In accordance with New York State Department of Health regulations, Polarized Light Microscopy is not consistently
reliable in detecting asbestos in non-friable organically bound materials, and in cases of a negative result TEM analysis
is performed.This method is sensitive to the detection of asbestos to less than one percent by weight.A material is
considered asbestos containing if it contains more than 1%asbestos.
NYSDOL and USEPA regulations define asbestos containing material as containing greater than one percent(1%).
Materials found to contain asbestos at concentrations of less than one percent(<1%) by weight are classified as
containing trace amounts of asbestos. It should be noted,OSHA's definition of"asbestos containing"does not have a
one percent(1%)cut-off,therefore,asbestos that is present in percentages less than one percent(<1%) continues to
be covered by OSHA Construction Standard 29 CFR 1926.1101.
Eurofins CEI-Lab ID#12048,completed the analysis.
WARRANTY
The field and laboratory results reported are considered sufficient in detail and scope to determine the presence of
accessible and/or exposed asbestos-containing building materials.The findings contained within this report have been
gathered in accordance with existing regulations and industry protocol.
This survey and analytical methods have been used to provide information regarding the presence of suspect interior
asbestos-containing building materials existing at the time of the inspection.This report is limited to the information
available from the client at the time it was prepared. It is possible that conditions may exist which could not be
identified within the scope of the survey or which were not apparent during the site visit.
Page 4 of 6
Foothills Builders,80 Main Street,Queensnury,New York,12887
Appendix A:
ACM Homogenous Area Table
(Material id,-:` ;;,1Vlater�al;::y. -S ace Naive;-,,, SeKtion'Nar�re---w�,,',Friabili' °�` ` '.current Giiridition ;.-.-Resuit:.- .;-:Quanti >:-
NO ASBESTOS DETECTED
Page 5 of 6
Foothills Builders,80 Main Street,Queensnury,New York,12887
Appendix B:.
Chain of Custody&Laboratory Report
Page 6 of 6
......................... .............. .................................................
-2
,�,Ll �� I 1111111 MEN 11 MORE 111.
IER
J4Y1 3Y
Chain of Custody
ClearVU Inspections
18 Blackberry Lane Project: 10141
.Site Location: House&Garage
Queensbury,New York 12804
80 Main Street
Queensnury,New York,12887
EUROFINS CE19 INC Sampled BY:I Ryan Wild(ryan@clear.vuinspecbons.com):
Relpprting-!By,�Ryan Wild,(ryan@clearvuinsr)ections.com)
MES ACCEPTED
�Purpose: Pre-Dern6lition
Laboratory Notes Turn-Ar.o.und rime. Request
Stop after first positive fbr.each.HM 2'Day
Samples.
_ZZ-17. 7
Sample ID Material 'Floor/Section Sp
ace Analysis
NY ELAP 198.1 &
001A 001. -Gray Stone.Foundation Mortar Garage Garage 198.4 RLM&TEM
where applicable
WELAP 198.1
001 B' 001 -Gray Stone Foundation Mortar Garage Garage 198A PLM&TEM
where applicable
NY ELAP 198.1 &
002A. 002,-Gray Masonry Brick Basement Exterior -198.4 PLM&TEM
where applica ble
NY ELAP 198.1 &
0026 002-Gray Masonry Brick Garage �Garage
g 198.4 PLM&TEM
where applicable
N Y-ELAP 198.1 &
003A 003-Gray Masonry Mortar Basement Exterior 198.4 PLM&TEM
where applicable
ClearVU Inspections-'Chain of Custody For Foothills builders
House&Garage-10141 1 of 3
Sample ID Material Floor/Section Space Analysis
NY ELAP 198.1 &
003B 003-Gray Masonry Mortar Basement Exterior 198.4 PLM&TEM
where applicable
NYELAP 198.1 &
004A 004-Gray Gypsum Wallboard Basement Exterior 198.4 PLM&TEM
where applicable
NY ELAP 198.1 &
004E 004-Gray Gypsum Wallboard Basement Exterior 198.4 PLM&TEM
where applicable
NYELAP 198.1 &
005A 005-Red Plaster Basement Exterior 198.4 PLM&TEM
J where applicable
NYELAP 198.1 &
005B 005-Red Plaster Second floor chimney 198.4 PLM&TEM
where applicable
NY ELAP 198.1 &
005C 005-Red Plaster Second floor chimney 198A PLM&TEM
where applicable
NYELAP 198.1 &
006A 006-Gray Woven Electrical Wiring Basement Exterior 198.4 PLM&TEM
where applicable
006E 006-Gray Woven Electrical Wiring First floor Kitchen NYELAP 198.1 &198.4 PLM&TEM
where applicable
NYELAP 198.1 &
007A 007-Brown Vinyl Cove Base&Mastic First floor Kitchen 198.4 PLM&TEM
r
where applicable
NYELAP 198.1 &
008A 008-Green Roofing,Composite Shingle Second floor Attic 198.4 PLM&TEM
where applicable
NY ELAP 198.1 &
008B 008-Green Roofing,Composite Shingle Second floor Attic 198.4 PLM&TEM
where applicable
NYELAP 198.1 &
010A 010-Sealant,Window Pane Glazing First floor Family Room 198A PLM&TEM
where applicable
C1earVU Inspections-Chain of Custody For Foothills Builders
House&Garage-10141 2 of 3
i
_.._..._..._..._........ ......._._.._..............._...__....................._......_.............._—.-----.._._..__...--------------...._._.—
I' Sample ID Material Floor/Section Space Analysis
l` WELAP 198.1.&
010E 010-Sealant,Window Pane.Glazing First floor- Living Room 198A PLM&TEM
where applicable.
10.14.2022 3PM
Sampled By Date Time
Received By Date 'Time Received By Date Time Received By Date 'Time
10.1.8.2022 4PM
Relinquished BY Date .Time Relinquished By Date Time Relinquished By Date Time
�Y
Analysis By Date Time
i�
1
I
ClearVU Inspections-Chain of Custody For Foothills Builders
House&Garage-10141 3 of 3
ti�� e u rof i n s
I
October 21, 2022
ClearVU Inspections
18 Blackberry Lane
Queensbury, NY 12804
CLIENT PROJECT: 10141
LAB CODE: N220302
Dear Customer:
Enclosed are asbestos analysis results for Asbestos Bulk samples received at our laboratory
on October 19, 2022. The samples were analyzed for asbestos using polarizing light
microscopy (PLM) and / or transmission electron microscopy (TEM) by New York State ELAP
approved methods.
Sample results containing >1% asbestos are considered asbestos-containing materials
(ACMs) per EPA regulatory requirements. The detection limit varies with the method chosen
for the analysis. Eurofins CEI is accredited by the New York State Department of Health
(NYSDOH) Environmental Laboratory Approval Program (ELAP), certificate#12048.
Kind Regards,
� vo
Tianbao Bai, Ph.D., CIH
Laboratory Director
r4vtA
TESTING
NVLAP LAB CODE 101768-0
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
eurofins
I
ASBESTOS ANALYTICAL REPORT
By: New York State ELAP Method
Prepared for
ClearVU Inspections
CLIENT PROJECT: 10141
LAB CODE: N220302
TEST METHOD: NYS ELAP METHODS 198.1, 198.4
REPORT DATE: 10/21/22
TOTAL LAYERS ANALYZED: 17
# LAYERS >1% ASBESTOS: 0
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary
®� le u rof i n s By: NEW YORK STATE METHOD
C !
PROJECT: 10141 LAB CODE: N220302
ASBESTOS BULK, NEW YORK STATE METHODS
Client ID`; Lab ID Color - Sample Description Total Asbestos%,
001A N4740 Gray Stone Foundation Mortar No Asbestos
Detected.0%
001 B N4741 Gray Stone Foundation Mortar No Asbestos
Detected.0%
002A N4742 Green, Gray Masonry Brick No Asbestos
Detected.0%
002B N4743 Green, Gray Masonry Brick No Asbestos
Detected.0%
003A N4744 Gray Masonry Mortar No Asbestos
Detected.0%
003B N4745 Gray Masonry Mortar No Asbestos
Detected.0%
004A N4746 White Gypsum Wallboard No Asbestos
Detected.0%
004B N4747 White Gypsum Wallboard No Asbestos
Detected.0%
005A N4748 Gray Plaster No Asbestos
Detected.0%
005E N4749 Gray Plaster No Asbestos
Detected.0%
005C N4750 Gray Plaster No Asbestos
Detected.0%
006A N4751A Gray Electrical Wiring No Asbestos
Detected by 198.4
---------------------------------- ----- ------ - ---- --------- ----
N4751 B White Electrical Wiring No Asbestos
Detected by 198.4
--------------------------------- - - ---- ----- - -- - --- - -----------
N4751 C Black Electrical Wiring No Asbestos
Detected by 198.4
006B N4752A Gray Electrical Wiring No Asbestos
Detected by 198.4
--------------------------------- ----------- -- - -------- --------
N4752B White Electrical Wiring No Asbestos
Detected by 198.4
---------------------------------------------------------------
N4752C Black Electrical Wiring No Asbestos
Detected by 198.4
Page 1 of 1
ASBESTOS BULK ANALYSIS
li e u rof i n s By: NEW YORK STATE METHOD
CI
Client: ClearVU Inspections Lab Code: N220302
18 Blackberry Lane Date Received: 10-19-22
Queensbury, NY 12804 Date Analyzed: 10-21-22
Date Reported: 10-21-22
Project: 10141
ASBESTOS BULK, NEW YORK STATE METHODS
Client ID Layer Number
Lab ID Lab Description Category Color
001A Stone Foundation Friable Gray Initial Observations:
N4740 Mortar Binder 35%
Silicates 65%
Method: Final Results:
198.1 No Asbestos Detectdabtal Asbestos: No Asbestos
Detected.0%
00113 Stone Foundation Friable Gray Initial Observations:
N4741 Mortar Binder 35%
Silicates 65%
Method: Final Results:
198.1 No Asbestos Detect6fttal Asbestos: No Asbestos
Detected.0%
002A Masonry Brick Friable Green, Initial Observations:
N4742 Gray Paint 5%
Binder 20%
Silicates 75%
Method: Final Results:
198.1 No Asbestos DetectETietal Asbestos: No Asbestos
Detected.0%
002B Masonry Brick Friable Green, Initial Observations:
N4743 Gray Paint 5%
Binder 20%
Silicates 75%
Method: Final Results:
198.1 No Asbestos Detectr.Tabtal Asbestos: No Asbestos
Detected.0%
Page 1 of 7
ASBESTOS BULK ANALYSIS
e u rof i n s By: NEW YORK STATE METHOD
Ca
Client: ClearVU Inspections Lab Code: N220302
18 Blackberry Lane Date Received: 10-19-22
Queensbury, NY 12804 Date Analyzed: 10-21-22
Date Reported: 10-21-22
Project: 10141
ASBESTOS BULK, NEW YORK STATE METHODS
Client ID Layer Number
Lab ID Lab Description. Category Color
003A Masonry Mortar Friable Gray Initial Observations:
N4744 Binder 40%
Silicates 60%
Method: Final Results:
198.1 No Asbestos DetectdTabtal Asbestos: No Asbestos
Detected.0%
003B Masonry Mortar Friable Gray Initial Observations:
N4745 Binder 40%
Silicates 60%
Method: Final Results:
198.1 No Asbestos Detectd'ibtal Asbestos: No Asbestos
Detected.0%
004A Gypsum Friable White Initial Observations:
N4746 Wallboard Cellulose 5% Gypsum 95%
Method: Final Results:
198.1 No Asbestos Detectelabtal Asbestos: No Asbestos
Detected.0%
004B Gypsum Friable White Initial Observations:
N4747 Wallboard Cellulose 10% Gypsum 90%
Method: Final Results:
198.1 No Asbestos Detect(Tabtal Asbestos: No Asbestos
Detected.0%
Page 2 of 7
ASBESTOS BULK ANALYSIS
e u r®fins By: NEW YORK STATE METHOD
I
Client: ClearVU Inspections Lab Code: N220302
18 Blackberry Lane Date Received: 10-19-22
Queensbury, NY 12804 Date Analyzed: 10-21-22
Date Reported: 10-21-22
Project: 10141
ASBESTOS BULK, NEW YORK STATE METHODS
Client ID Layer Number
Lab ID.. Lab Description Category Color
005A Plaster Friable Gray Initial Observations:
N4748 Cellulose 2% Silicates 10%
Binder 88%
Method: Final Results:
198.1 No Asbestos Detectd'cbtal Asbestos: No Asbestos
Detected.0%
005B Plaster Friable Gray Initial Observations:
N4749 Cellulose 2% Silicates 10%
Binder 88%
Method: Final Results:
198.1 No Asbestos Detect(Tabtal Asbestos: No Asbestos
Detected.0%
005C Plaster Friable Gray Initial Observations:
N4750 Hair <1% Binder 40%
Silicates 60%
Method: Final Results:
198.1 No Asbestos DetectETabtal Asbestos: No Asbestos
Detected.0%
006A 1 NOB Gray Initial Observations:
N4751A Electrical Wiring Matrix 100%
Method: Final Results:
Total Asbestos: No Asbestos Detected
by 198.4
198.4
None Detected
Page 3 of 7
ASBESTOS BULK ANALYSIS
e u rof I n s By: NEW YORK STATE METHOD
I
Client: ClearVU Inspections Lab Code: N220302
18 Blackberry Lane Date Received: 10-19-22
Queensbury, NY 12804 Date Analyzed: 10-21-22
Date Reported: 10-21-22
Project: 10141
ASBESTOS BULK, NEW YORK STATE METHODS
Client ID Layer Number
.Lab ID -Lab Description Category Color
--- -
-N4751 B 2 NOB White Initial Observations
Electrical Wiring Matrix 100%
Method: Final Results:
Total Asbestos: No Asbestos Detected
by 198.4
198.4
None Detected
--------- ----------- - ----------- - ------ ---------- - - - - -- -----------
N4751C 3 NOB Black Initial Observations:
Electrical Wiring Matrix 100%
Method: Final Results:
Total Asbestos: No Asbestos Detected
by 198.4
198.4
None Detected
006B 1 NOB Gray Initial Observations:
N4752A Electrical Wiring Matrix 100%
Method: Final Results:
Total Asbestos: No Asbestos Detected
by 198.4
198.4
None Detected
Page 4 of 7
1 I
ASBESTOS BULK ANALYSIS
4�% e u r®fins By: NEW YORK STATE METHOD
CEI
Client: ClearVU Inspections Lab Code: N220302
18 Blackberry Lane Date Received: 10-19-22
Queensbury, NY 12804 Date Analyzed: 10-21-22
Date Reported: 10-21-22
Project: 10141
ASBESTOS BULK, NEW YORK STATE METHODS
Client ID -. Layer;Number;
Lab Np>,. Lab Description Category Color
-N4752B--` 2 -_ -- --NOB - -White -- - - -Initial Observations
Electrical Wiring Matrix 100%
Method: Final Results:
Total Asbestos: No Asbestos Detected
by 198.4
198.4
None Detected
------------------------------------------- ----------------------•
N4752C 3 NOB Black Initial Observations:
Electrical Wiring Matrix 100%
Method: Final Results:
Total Asbestos: No Asbestos Detected
by 198.4
198.4
None Detected
Page 5 of 7
el s� eurofinS
CEI
LEGEND
Non-Anth = Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb = Calcium Carbonate
NOB = Non-Friable Organically Bound
SM-V = Surfacing Material Containing Vermiculite
GLOSSARY OF TERMS
Inconclusive- No Asbestos Detected
PLM is not consistently reliable in detecting asbestos in floor coverings and other NOB
materials. Currently, quantitative TEM must be used to determine if this material can be
considered or treated as non-asbestos containing.
Inconclusive- CR
Conflicting Results: Sample yielded 1% or less asbestos as determined by gravimetric
reduction and TEM analysis but had protruding fibers identified as asbestos during
preliminary examination -further sampling and analysis needed.
Inconclusive-Trace (type of asbestos) detected at 1% or less
Asbestos identified at 1% or less by the 198.6 method, and 0 asbestos points out of 400 (or
more) nonempty points were counted. Further testing by TEM using NYS 198.4 method is
required.
Trace asbestos detected at less than 1%
For methods 198.1 and 198.8, NYSDOH defines trace as samples where 0 asbestos points
out of 400 (or more) nonempty points were counted, but did contain asbestos positively
identified by PLM.
Trace asbestos detected at less than 1%
For method 198.4 NYSDOH defines trace as asbestos detected at 1% or less.
REGULATORY LIMIT; > 1% by weight
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 6 of 7
eurofins
CEI
DISCLAIMERS:
Reported asbestos content verifiable only as the percentage of asbestos in residue submitted to
laboratory. Samples with inconclusive results must not be interpreted as being non-ACM.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding
the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the customer. Samples were received
in acceptable condition unless otherwise noted. This report may not be used by the client to claim
product endorsement by NVLAP, NYSDOH or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID, location, volume and area as well as
date and time of sampling.
ANALYST(S):
reg uff- 19re.1
'ld4
Brunilda Gjoka -9198.4
APPROVED 13)
!tio
Tianbao Bai, Ph.D., CI
Laboratory Director
m V
TESTING
NVLAP LAB CODE 101768-0
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 Page 7 of 7
,. .: i
µ New,*jrk State L-Depgrtm6 t-o . abor
Division o '84gly and lealth
License and MtOlcao6nitt
State Cus,Building 12 /'a
I
Albany,,NY,.,_12240 ,. �•.
„ ASBESTOS HANDLING LICENSE - -
restive Spaces Il, dba ClearVU�lpSpection3s j` F�LE NUMBER:
LICENSE NUMBER:`,282890
180Blackberry Lae LICENSE CLASS: RES 1_"RI : •
� :a a
g� IIN DATE OF ISSUE: 01/28r2'Q22
' Q eC)`sbury, Y 12804 ,. �. �,
EXPIRATION DATE: 01/312023
JiNim-
o
',Iy Au ori7e °.Representativw,�4,Ryan'11V�d. �hr"!✓": ^, - _ ;_° ` > #"rj
,a Jj. , e' er ..�. .• '+5{iL;y��t 1 �� II .,.w
� "a '+ �. r,P I.•' ..i�'�cr4r..6 , � .S
.a
{ is`3tcen5 li been issued in ac 4 dat}cey ith hbAl rpxi'st*ifz'o ^ Q'bf the Laliar Law of New ,. r t a e rid o
7 � �� .f.
t ie New o.R Via Codes,Rules ' t i2egu�at 5 1 N @ 2RPart°5¢)r Itis tx ect to su$ e�►sion or revocat on�or a(1)
se io s vio•atio Astate federal�r t cal aWs ark� o.t e c uct`of d esto ro or 2 demo- irate
t1 ;s .: pg>�Ti�v jh, � nd ���. rk�54 �P � ( ) p ack
reo �ibitiy in thenduct of anya invalvi cos'o asb � rat.y E�,,,.,, "" �"g �s ..--.._...� .• �1 qx tE+1^�Ea isAi�. r•�_'���r�' -Al'Yf� 5k�
9,� ....,,,� t 6 5 f
Thi§ icerlse is valid on]),for tjie contraetor_r _`aTi and tisicense oo .p_y_mustepminently displayed at th,e
asbestos pro'e �xksite Thi l•cegse veri'ftes tha9I,lIpersons-empl �etiby ttie hcesee on an aslfess project in New Y
s��State ha .e een s d an tl.sbestos Certificate;appr,.opri�t�o�fhe�type o v`�axk-they perform,by the,New Yor .�Iat
Depart ntoibor. 4,R - __._ - --" t Nx
f4
m.f,q,
tin R ld° S' • «
Amy Phillips,Director
SH 432(8/12) For the Commissioner of Labor
✓YSTATE&Nb YORl 'DEPARTMENT OF l ARC}R w
ASBESTOS CERTIFICATE.
RYAN.:P-,WILD-
°CLASS(EXPERES)
CATEQ05/23),'D.INSP(05`/ j
1..'. ... .4.pgt��I�:tpp]�ip•Yjf� .j2�yE�"p"9�3aY 428 p�
✓ ..�`�.. :.., _. ... ..��+fYb Y-M. 1 t�J V�:,Y�3.,I.U,to•'•
r NIPSTSE CARRIED QN.ASBESTOS''PROJECTS:
._..;��..�.__.�,. ;' '. IIIIIItlll�l•IIt11RH1._..16f_%z
. �Illllllf LIIIII lII�lIIIlI I III
:I£+' FOUND RETUEM Td:
N ETES SRO VYSDOL - L&C UNIT
M�
° HAM BRO" ROOM 161A BLJI'LDINt3.12, .
e HGT "6:' 03":':-.:_ STATE OET. CAMPUS,
AIlZA]4Y- NY 12240:
P.�.� �,�,,.., --..�,..roc*.._ _....-P.,^=�r-�'"'"""'�m%-^�,.«s^,Y•+,.•.^.�°
RYANt. WILL)
o ¢ o
s• •doalg
6L ARwwwW s s s
N S R E C T t O N S
NEW YORK STATE DEPARTMENT OF.HEALTH
WADSWORTH CENTER
_ Expires 12:01 AM April 01, 2023
,. Issued April 01, 2022
CERTIFICATE OF APPROVAL FOR LABORATORY SERVICE
Issued in accordance with and pursuant to section 502 Public Health Law of New York State
DR. TIANBAO BAI NY Lab Id No: 12048 =
EUROFINS CEI, INC. --
730 SE MAYNARD ROAD
CARY, NC 27511
is hereby APPROVED as an-Environmental Laboratory in conformance with the
National Environmental Laboratory Accreditation Conference Standards(2016) for the category
ENVIRONMENTAL ANALYSES POTABLE WATER
- All approved analyfes are listed below:
Miscellaneous
Asbestos _ EPA 100.2
Serial No.: 64945 �fro
Property of-the New York State Department of Health. Certificates are valid only at the address shown,must be conspicuously posted,and are printed on secure paper. Continued accreditation depends
an successful ongoing participation in the Program. consumers are urged to call{518)485 5570-to
verify the'laboratoiy's accreditation status. "
- ottxno�'
Page 1 of 1
NEW YORK STATE DEPARTMENT OF.'HEALTH:
WADSWORTH CENTER
Ex keCl 2:01 U AMA ptil'61j��023z=_.
s .udd. Apdl 01, 2022
CERTIFICATE OFAPPROVAL FOR LABORATORY SERVICE
Issubd In accordince with and pursuant to section 502 Public Health Law of Now VbtkState:4-
DR.=TIANBAO BAF
NY Lab Id No: 12048 .
EUR OFINS CEJ-1 lk d!—,
730 SE MAYNARD ROAD
X, NC 27eff
an-Environmental 404or*ry for the caftory
ENVIRONMENTAL ANALYSES SOLID AND HAZARDOUS WASTE'
All s&rqvdd subcategor1e;_and1bC�_;ana1ytqs are listed below:
..-Miscellaneous
Asbestos In Ffi6ble Matedal.- Item 198.1 of Manual
Asbe6lds on.MIN Friable Mateifil-PEM -Atem imp of Manual(NOBby PLM)=.
Asbestos In Non-Friable Material-TEM Item 198.4 of Manual
AsbeiC6i-Vanniculite-Coniil�ntfig Material Item 198.8 of Manual
Serial No,-* 64946'
Pmpertyof-the New York State Departmera fieittth.-Cerdffcqtea 66 iralld only at the iddmss-
be.consplduously posted.-and are pdqW,.o shomi must n secure paper. Continued accreditation.depends
nsucqeqdq.c!*o1ng ftdpa n In ft Program:consumers are urged to c#11(51SY485-551n_p
e 16 ft
.-bors oys C6Q1taVorf_StE1tUS.
=6gq 11of 1_