SEP-0582-2022 Office Use Only;,.:
SEPTIC,;VARIANCE: p
- Permit#: c�C:-t ✓82-�Z2-
APPLICATION Permit Fee:
Town of Qgmcnsbury I
- Invoice#:
742 Bay Road,Queensbury,NY 12804
P:518-761-8256 www.gueensbury.net Approvals:
Submittal: 1 (one) original & 8 copies of the completed application package
PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
Section 1:
Contact Information:
Property Owner's): Lorraine W Dickinson Trust Owner's agent: Hutchins Engineering PLLC
Address: 239 Vaughn Road Address: 169 Haviland Road
Hudson Falls, NY 12839 Queensbury, NY 12804
Phone#: Phone#: 518-745-0307
Email: Email: thutchins@hutchinsengineering.com
Section 2:
Site Information:
Site Address: 113 Rockhurst Road Tax ID#: 227.9-1-7
Directions to site: from NY-91- N turn right onto Cleverdale Road for 0.8 miles right onto Rockhurs1M
for 0.7 miles; parcel on left side D E Ou" E 9 W
Section 3:
Lace water supply SEP 1 2022
Distance from Q on property to septic system (if applicable) 75 y
fe t
Section 4:
TOWN OF QUEENSBIIf1Y
Is it possible to install a conforming septic system on this property? ❑Yes o BUILDING&CODES
If YES, please explain and attach a diagram:
Section 5:
Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring
properties? *Yes ❑ No If NO, please explain: No Neighboring Wells
Section 6:
Is the proposed system to be installed under a parking area? ❑Yes No
Section 7•
Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system will be 89 ft.
from well in lieu of required 100 ft.): See Attached Variance Summary
Septic variance Application Revised December 2021
l
i
Section 8:
i
List the names, parcel addresses, and tax map numbers of all adjoining property owners, You may obtain this
information from the Town of Queensbury's Assessor's Office:
North Name Lamberts Landing LLC -
Address 117 Rockhurst Road
Tax Map ID 2217.9-1-8
South Name . John A. Swan
Address 111 Rockhurst Road
Tax Map ID 227.9-1-6
East Name Carl Weiner
Address 114 Rockhurst Road
Tax Map ID 227.9-1-9
West Name Lake George
Address
Tax Map ID
Section 9•
OWNER STATEMENT
Me,do,hereby;relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
113 Rockhurst Rd ` . I/We realize that putting the well, septic tank or leaching system less than the required feet
from the Lake Water Supply may increase the risk of pollution.
Owner—Print Name: Lorraine W Dickinson Trust
Owner—Signature: Date:
Section 10:
NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable)
I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
. I/We realize that putting the well, septic tank or leaching system less than the required feet
from the _may increase the risk of pollution.
Neighbor/Tenant—Print Name:
Neighbor/Tenant-Signature: Date:
Septic Variance Application Revised December 2021
,Y
Section 11:
AUTHORIZATION AND SIGNATURE PAGE
This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site
visits, other permit responsibilities and agreement to provide documentation required.
Complete the following if the OWNER is using an Agent:
Owner's Name: I orral.ne W Dickinson Trust
Hutchins Engineering PLLC
Designates: as agent regarding the Septic Variance for
Site Address: 1-1_3_Rockhurst_Road
Tax Map #: 227.9 1-7
Errgineerinp, Fee Disclosure:--Applications may be referred to the Town consulting engineer for review of septic
design, storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services
will be charged directly to the applicant.
Authorization-for-Site=Visits:-By signing this page and submitting the application materials attached herein,the
Owner,Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code
Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the
application submitted.
Please Note: Other permits may be required for construction or alteration activity subsequent to approval by
the Town Board of Health. It is the applicant's responsibility to obtain any additional permits.
OfficiahMeeting Minutes-Disclosure It is the practice of the Town Board of Health to have a designated
stenographer tape record the proceedings of the meetings resulting from the application, and that the
minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy
between such record and the handwritten minutes taken by the designated stenographer,the handwritten
minutes shall be deemed the official record.
I,the undersigned, have thoroughly read and understand the instructions for submission;agree to the
submission requirements and completed checklist:
OWNER—PRINT NAME: Lorraine W Dickinson Trust _
OWNER—SIGNATURE: DATE: a
AGENT—PRINT NAME :G homas Hutc 'ns, R—E
AGENT—SIGNATURE: - DATE:
'Septic Variance Application Revised December 2021
169 Haviland Road
Queensbury, NY 12804
Hutchins Engineering Phone: (518)745-0307
`_. Fax: (518)745-0308
September 16, 2022
DE � �K
Town of Queensbury, Local Board of Health
742 Bay Road SEP 1Queensbury, NY 12804TOWN OF QRe: Lorraine W. Dickinson Trust BUILDING
113 Rockhurst Road, Queensbury
Tax Map ID#: 227.9-1-7
Dear Supervisor Strough and Town Board Members:
Attached please find a plan and application for septic variance to allow a replacement septic
system to be installed for the Lorraine W. Dickinson Trust, John Dickson, trustee, at the above-
referenced residence.
The proposed treatment system will consist of a FujiClean CE-5 enhanced treatment unit, 100-
gallon polyethylene basin grinder pump, a 1,000 gallon precast concrete, heavy duty effluent
pump station, and a 13'W x 241 crushed stone absorption bed with three rows of three 34"traffic
rated Infiltrator H-20 chambers. Every effort has been made to provide a high-quality enhanced
treatment system and minimize requested variances.
We are seeking relief from the absorption field setback to shoreline (75' proposed instead of
required 100'), the absorption field setback to easterly property line (1' proposed instead of
required 10'), Fuji Clean ETU to house (4' proposed instead of the required 10'), Fuji Clean ETU
to property line (2.5' proposed instead of the required 10'), grinder pump to shoreline (33.5'
proposed instead of the required 50'), forcemain to shoreline (34' proposed instead of the required
50'), forcemain to house (1.5' proposed instead of the required 10'), the effluent sewer line to
house (6' proposed instead of the required 10'), the effluent sewer line to property line (5'
proposed instead of the required 10'), the effluent pump station to house (3' proposed instead of
the required 10'), and the effluent pump station to the property line (2' proposed instead of the
required 10').
We respectfully request to be placed on the board schedule for the upcoming September 26
meeting.
Please contact me if you have any questions or if you require additional information.
Best Regards,
G. Thomas Hutchins, P.E.
Cc: John Dickinson, Trustee of Lorraine W. Trust
G.Thomas Hutchins, P.E. thutchins@hutchinsengineering.com
eorge
LAKE W ATER INTAKE
APPROXIMATE LOCATION
FF 335.5±
PROP.1.5" HOPE
FORCEMAIN, PROVIDE
T BURIAL DEPTH
PROP. 40 GAL POLY
PACKAGED GRINDER
PUMP STATION
PROP. W, PVC SCH-40
HOUSE SEWER
LAKE WATER 227.9.1-8
SUPPLY Lands N/F of
Lambert's Landing LLC
8:5023 P:173
6. c. I . v - I - V
LAKE WATER 111 Rockhurst Road
SUPPLY Lands N/F of
John & Carolyn Swan
B:5107 P:35
WASTEWATER SYSTEM PLAN
SCALE: 1 "--10'
GRAPHIC SCALE
5 0 2.5 5 10 20
( IN FEET )
PROP. FWICLEAN CE-S
ENHANCED TREATMENT UNIT
PROP. low GAL HEAVY WIN
PRECAST CONCRETE EFFWENT
PUMP STATION WITH SALCOR
UV DISINFECTION
227.9-1-9
114 Rockhurst Road
Lands of
Carl & Michele Weiner
B:4226 P:265
LAKE WATER
SUPPLY
Stockade Fence
VERTICAL DATUM
NORTH AMERMAN VERTICAL DATUM! OF 1929 (NOVD29)
SEPTIC VARIANCE SUMMARY
1. ABSORPTION FIELD TO SHORELINE
I 00'REQUIRED
75' PROPOSED
25' OF RELIEF REQUESTED
2. ABSORPTION FIELD TO EASTERLY PROPERTY LINE
10' REQUIRED
i'PROPOSED
9' OF RELIEF REQUESTED
3. Fuff CLEAN ETU TO HOUSE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
4. Rar CLEAN ETU TO PROPERTY LINE
10' REQUIRED
2.5' PROPOSED
7.5' OF RELIEF REQUESTED
5. GRINDER PUMP TO SHORELINE
50' REQUIRED
33.5' PROPOSED
16.5' OF RELIEF REQUESTED
6. FORCEMAIN TO SHORELINE
50' REQUIRED
34'PROPOSED
16' OF RELIEF REQUESTED
7. FORCEMAIN TO HOUSE
10' REQUIRED
1.5' PROPOSED
8.5' OF RELIEF REQUESTED
& EFFLUENT SEWER TO HOUSE
10' REQUIRED
6'PROPOSED
4' OF RELIEF REQUESTED
9. EFFLUENT SEWER TO PROPERTY LINE
10' REQUIRED
5'PROPOSED
Y OF RELIEF REQUESTED
10. EFFLUENT PUMP STATION TO HOUSE
10' REQUIRED
3'PROPOSED
7 OF RELIEF REQUESTED
11. EFFLUENT PUMP STATION TO PROPERTY LINE
10' REQUIRED
2'PROPOSED
7 OF RELIEF REQUESTED
MAP REFERENCE:
227.9 -1-10 BASE MAP INFORMATION FROM "MAP OF A SURVEY
112 Rockhurst Road LAKE WATER MADE FOR JOHN AND DAWD DICKINSON," IN THE
Lands N/F of SUPPLY TOWN OF QUEENSBURY, WARREN COUNTY, NEW
Eric K Cottrell YORK. DATED FEBRUARY 2, 2022. PREPARED BY B:1441 P:102 an Du s e,#
Steves
Land Surveyors
169 Hadland Road Queemb=7, Now York 12804
(518) 792-8474 New York Lie. No. 50135
INS
SITE LOCATION LOCATION MAP
.SITE SOILS DATA
TEST PIT
TP-1 - 811012022 BY TOM HUTCHINS, P.E.
0-6" - TOPSOIL
6-48" FINE & MEDIUM SAND WITH
CONCRETE DEBRIS, BRICKS, ETC.
FROM PREVIOUS BUILDING.
DEBRIS TO BE REMOVED
NO BOUNDARY CONDITION TO 48"
SITE LOCA
NEIGHBORHOOD MAP
PRELIMINARY,
FOR REVIEW ONLY,
f
SE1, is
r0 OF
eu� NGUEENSEU
& Op0ESRY
NOT FOR CONSTRUCTION
FILE COPY
WASTEWATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELL
WATERLINE
HOUSE
LAKE
GEORGE
SEP77C TANK, PUMP
STATION, FORCE
10,
50'
10,
10,
50'
MAIN, EFFLUENT
SEWER
ABSORPTION FIELD
10,
100,
10,
20'
100,
Dig 'Safely.
NewPffork
E Call Before You Mg
® Wait The Required Time
® confirm Utility Response
N Respect The Marks
M Dig With Care
800-962-7962
www.digsafe"wyork.com
ALTERATION OF THIS DOCUMENT
EXCEPT BY A LICENSED
PROFESSIONAL ENGINEER IS A
VIOLATION OF NYS EDUCATION LAW.
TAX MAP # 22Z9-1-7
227.9-1-7 SEP-0582-2022
Lorraine Dickinson Trust
113 Rockhurst Rd
Septic Variance/Alteration
0 ISSUED FOR SEPTIC VARIANCES
No. Revisions
WASTEWATER SYSTEM PLAN
prepared for:
Lorraine W Dickinson Trust
113 Rockhurst Road
Town of Queensbury, County of Warren, State of New York
Drawn: JRS/LWD Checked: GTH Scale: NOTED Date:
169 Haviland Road
Date
Queensbury, NY 12804 29200o_O1_c�7l
Hutchins Engineering PLLC (51s) 745-0307 Phone
9 9 (518) 745-0308 Fax
WASTEWATER SYSTEM DESIGN
3-BEDROOM RESIDENCE DESIGN BASIS
WATER SAWNGI FIXTURES
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
PRETREATMENT TANK - FZUafAN MODEL CE-5 E.T.U.
GRINDER PUMP STATION - 100 GAL PACKAGED POLYETHYLENE BASIN
GRINDER PUMP TO BE LIBERTY PROVE PRG-100 SERIES,
22OV, 1 HP OR APPROVED EQUIVALENT, TO BE INSTALLED
AT LAKESIDE BUNKROOM
EFFLUENT PUMP STATION - 1000 GAL PRECAST CONCRETE, HEAVY DUTY
WIDUPLEX ALTERNATING PUMPS & DEMAND DOSING
DESIGN APPLICA71ON RATE: 0.8 GPD/SF, BASED ON
6-7 MIN/IN PERCOLATION RATE
(BLEND OF NA71VE & FILL SOILS)
ABSORPTION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF)
= 413 SF
33% E.T.U. REDUC71ON AREA REQ'D = 277 SF
ABSORPTION BED AREA PROVIDED = 13'x24' = 312 SF
WITH THREE ROWS OF (3) H-20 34-W INFILTRATOR CHAMBERS
WASTEWATER SYSTEM FILL
MATERIAL NOTES
AFTER REMOVING ORGANICS, TOPSOIL & DEBRIS, PLACE SYSTEM
FILL OVER THE EN77RE AREA OF PROPOSED ABSORP7ION BED AND
TAPER AREA.
"ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY
SELECTED SAND OR SANDY LOAM WITH IN -PLACE PERCOLATION
RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3-
IN SIZE LESS THAN 10% BY WEIGHT SHALL BE FINER THAN
0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE
1N THE RANGE OF 0.50mm TO 2.0mm. LESS THAN 15% OF THE
MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2- SIEVE.
ABSORP7ION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED
TO PROVIDE MINIMUM OF 3-FEET BETWEEN BOUNDARY CONDITION
AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL
SHALL BE INSTALLED THROUGHOUT THE ABSORP7ION BED AREA
AND TAPER AREAS
ABSORP7ION AREA SYSTEM FILL MATERIAL IS TO BE
MECHANICALLY STABILIZED IN 12" LIM NTH TRACKED EQUIPMENT
PRIOR TO INSTALLA71ON OF ABSORPTION TRENCHES
INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF
SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING 70 SITE
INSTALL POLYETHYLENE EXTENSION
TO GRADE 107H TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
1/4- PER FOOT
MIN. SLOPE
4" PVC SCH-40 HOUSE SEWER
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE
WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND
ASTM F481 INSTALLATION OF 7HERMOPLAS71C PIPE AND CORRUGATED TUBING IN
SEPTIC TANK LEACH FIELDS.
AFTER PLACEMENT OF SYSTEM FILL AND EXCAVATION OF 13' WIDE X 30' LONG
ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE
CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL
BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE
GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT
CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS OR OTHER
UNSUITABLE CONDITIONS PIPE SHALL BE LAID NTH HOLES DOWN IN ALL CASES.
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT
SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN 774E ABSORP7ION AREA AFTER PIPING
HAS BEEN INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON
THE INSTALLA77ON OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110
GPO PER BEDROOM. 774E SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME
WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT. 774E INSTALLATION OF NON -CONSERVING WATER FIXTURES OR
EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS
WASTEWATER TREATMENT SYSTEM.
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE
EXCLUDED FROM THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT
SURFACE RUNOFF AROUND ABSORP7ION FIELD.
SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY TOWN
OF QUEENSBURY BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO
BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF 774E CONTRACTOR
TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS.
SYSTEM MATERIAL SPECIFICATIONS
34" WIDE OPEN -BOTTOM GRAVRLESS CHAMBER
OPEN —BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH CAPACITY.
HOUSE SEWER PIPE
PIPING TO BE 4' SCH-40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL W17H 1/8- PER FOOT MINIMUM SLOPE
FORCBWN
PIPING TO BE 2" SDR-26 PVC. MAINTAIN 3' MINIMUM COVER AND POSITIVE
DRAINBACK TO PUMP STATION.
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4- TO 1-1/2- WASHED CRUSHED STONE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARA77ON FABRIC, TENCATE
MIRAFI 140N OR EQUIVALENT.
FILL MATERIAL
FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED IN "FILL
MATERIAL NOTES -
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORP71ON FIELD AREA. SEED AND
ESTABLISH TURF.
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL SALCOR ULTRAVIOLET
TREATMENT UNIT
2" 1/8" PER FOOT
MIN. SLOPE
4' PVC SCH-40 EFFLUENT
CHAMBER 1 CHAMBER 2
DIMENTA77ON A VAEROBIC CONTACT CHAM 3
CHAMBER TRATION CHAMBER AEROBIC ACT
rRAnoN cH BER
ALARM 3" ABOVE 'PUMP ON'
& LAG PUMP ON
59" FLOAT SWITCHES — PUMP ON
INSTALL INSIDE PUMP PIT
IN LOCATION ACCESSIBLE
WITHOUT PIT ENTRY PUMP OFF
FUJI CLEAN USA MODEL CE-5
ENHANCED TREATMENT UNIT
MAINTENANCE CONTRACT NOTE
A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM
OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED
FOR SEMI—ANNUAL INSPECTION AND SERVICE OF THE
FUJICLEAN CE-5 ENHANCED TREATMENT UNIT.
VOLUME OF DOSE TO
BE 80± GALLONS
°
e
POLYETHYLENE EXTENSION &
TAMPER RESISTANT COVER
TRANSITION TO 4" PVC
1/4" PER FOOT
MIN. SLOPE
BALL CHECK VALVE
28" DIA.
40 GALLON
POLYETHYLENE
PUMP STATION
EXTERIOR WEATHERPROOF CONTROL PANEL, ALARM &
WATER SHUT -DOWN RELAY, MOUNTED ON SIDE OF
HOUSE, IN COORDINATION WITH OWNER. SEAL CONDUIT
WEATHER7IGHT ALL ELECTRICAL WORK TO BE INSPECTED
BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR
TO START-UP OF PUMP STATION.
2" HDPE
FORCEMAIN
2" SCH-40 PVC PIPING INSIDE
WET WELL THROUGH BASIN WALL
REDUCING TEE POINTED DOWNWARD
WITH 1- BALL VALVE THROTTLED TO
ALLOW TRICKLE DRAIN BACK INTO
WETWELL
BALL VALVE
UNION - LOCATE SUCH THAT
UNION CAN BE DISCONNECTED AND
PUMP REMOVED WITHOUT TANK
ENTRY
NORMAL LIQUID LEVEL±
SIMPLEX GRINDER PUMP
GRINDER PUMP STATION DETAIL
N7S
4" MIN. TOPSOIL,
SEED, MULCH &
ESTABLISH TURF
8" MIN. GRANULAR BACKFILL-
PUMP STATION NOTES
SEAL ALL TANK OPENINGS WATERTIGHT.
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP
CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM.
INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL ON THE
SIDE OF HOUSE IN COORDINATION WITH OWNER.
PROVIDE HIGH —ALARM FLOAT WITH LOCAL AUDIO/VISUAL
ALARM..
INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH
ALARM IN HOUSE 1N ACCORDANCE K17H MANUFACTURER'S
INSTRUC71ONS AND NATIONAL ELECTRIC CODE (N.E.C.)
REQUIREMENTS
PUMP CONTROL AND FLOAT LEVEL TO BE INSTALLED TO
PROVIDE A 15 GALLON DOSE.
GRINDER PUMP PACKAGE TO BE LIBERTY PROVOKE 380
SERIES, 115V, I HP OR APPROVED EQUIVALENT.
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO
PURCHASING PUMP.
ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED
ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF
PUMP STATION.
1 W ROADWAY
z
13' BED WIDTH
IW
4' CHAMBER SPACING I o
r4" RE
SYSTEM SAND FILL, J FILTER FABRIC J 4" PVC INTO END J INFILTRATOR H-20 —I
STABILIZED IN 1-FT LIFTS, CAP OF CHAMBER CHAMBER PER PLAN
PRIOR TO INSTALLING FIELD
ABSORPTION FIELD SECTION
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL FLOAT
SWITCHES TO OPERATE
PUMP AND MAINTAIN
LEVELS AS INDICATED
BALL VAL VE
INSTALL VALVES AND
UNIONS SUCH THAT EITHER
PUMP CAN BE ISOLATED
AND REMOVED WITHOUT
REQUIRING PIT ENTRY
.O BALL CHECK VALVE
-O FLOAT SWITCHES -
INSTALL INSIDE PUMP PIT
IN LOCA71ON ACCESSIBLE
WITHOUT PIT ENTRY
16" MIN.
d
1,000 GALLON PRECAST CONCRETE PUMP STA77ON
FUJI CLEAN ENHANCED TREATMENT UNIT & PUMP STATION DETAIL
NTS
NIS
ASSORP71ON BED
STONE AGGREGATE
SAL COR UV DISINFECTION UNIT
ELECTRICAL JUNCTION
BOX WITH INDICATORS -
AND ALARM CONTACTS
4' PIPE--_,,�
p�T WENT
EFFLUENT
CA
SECTION A -A III
� &
Eli
DISINFEC77ON
SUB — ASSEMBLY
HANDLE
FOR
REMOV4
SUPPORT
FRAME &
GASKET
UV LAMP
QUARTZ YUBE
TEFLON COVER
NOTE. • NOT ALL DIMENSIONS TO SCALE
SALCOR UV DISINFECTION UNIT
NTS
MBER
4T
134" CHAMBER WIDTH
INFILTRATOR H-20
CHAMBER SECTION
NTS
75" EFFECTIVE LENGTH L
INFILTRATOR H-20 CHAMBER PROFILE
EXTERIOR WEATHERPROOF JUNCTION BOX NTS
(IF NECESSARY). SEAL CONDUIT GAS
77GHT. INSTALL CONTROL PANEL IN
HOUSE ALL ELECTRICAL WORK TO BE
INSPECTED BY A CERTIFIED ELECTRICAL
INSPEC71ON AGENCY PRIOR TO START-UP
OF PUMP STATION.
2" MIN. DROP
DISTRIBUTION BOX F BETWEEN INVERTS
a°
7,00, v
TRANSITION TO 4"--/,0,
°
OUTSIDE OF D-BOX
CONCRETE BAFFLE 20 MIN.
USE SPEED LEVELERS TO ASSURE
°
ALL OUTLETS ARE AT
TAX MAP # 22Z9-1-7
EXACTLY THE SAME ELEVATION
a
4" PVC SDR-35 SOLID
HEADER TO MANIFOLD PIPING
Dig
1/8- PER FOOT MIN SLOPE
NeWISafelys
murk
1-1/2- HDPE
PUMP STATION NOTES
E Call Before You Dig
SDR-11 FORCEMAIN
0 Wait The Required Time
°
SEAL ALL TANK OPENINGS WATERTIGHT.
N Confirm fJBifty Response
°
2" SCH-40 PVC PIPING
The
N D g VAth CareMMarks
INSIDE WET WELL THROUGH WALL PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL
800-962-7962
PANEL W17H VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX,
0
ISSUED FOR SEPTIC VARIANCES
UNION - LOCATE SUCH THAT ALTERNATING, DEMAND DOSE CONTROL PANEL INSIDE HOUSE
www.mgssfeiynewyork.com
No.
Revisions
UNION CAN BE DISCONNECTED AND IN ACCESSIBLE LOCATION, SJE RHOMBUS IFS SINGLE PHASE
PUMP REMOVED WITHOUT TANK DUPLEX DEMAND DOSE CONTROLLER.
ENTRY
WASTEWATER DETAIL
REDUCING TEE POINTED DOWNWARD INSTALL POWER & CONTROL WIRING TO CONTROLLER 1417H
prepared for
WITH 1" BALL VALVE THROTTLED TO ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S
ALLOW TRICKLE DRAIN BACK INTO INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.E.C.)
Lorraine W Dickinson Ti
WETWELL REQUIREMENTS
113 ROCkilurst Road
GOULDS WE05H EFFLUENT PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO
Town of Queensbury, County of Warren, S1
PUMPS (DUPLEX) ALTERNATE PUMP DOSING AND TO PROVIDE AN 80 GAL DOSE
Drawn: JRS/LWD
Checked: GTH
Scale: NOTED
PUMPS TO BE GOULDS MODEL 3885, WE05H 230V, SINGLE PHASE;
35 GPM PUMP AT 30 FT TDH.
ALTERATION OF THIS DOCUMENT
169 Havlland Roo
EXCEPT BY A LICENSED
abbhk., Queensbury, NY 12
VERIFY ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP.
PROFESSIONAL ENGINEER IS A
... _._-_ .-__ _ _w. . w (518) 745-0307 Ph
16" CHAMBER
HEIGHT
s
RESOLUTION APPROVING LORRAINE W. DICKINSON TRUST'S
APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES
RESOLUTION NO.: BOH 81,2022
INTRODUCED BY: Mr.Anthony Metivier 227.9-1-7 SEP-0582-2022
WHO MOVED ITS ADOPTION Lorraine Dickinson Trust
SECONDED BY: Mr. George Ferone 113 Rockhurst Rd
Septic Variance/Alteration
WHEREAS, the Lorraine W. Dickinson Trust(Applicant) filed an application for variances
from provisions of the Town of Queensbury On-Site Sewage Disposal Ordinance, Chapter 136 to
install a replacement septic system with the:
1. Absorption field to be located 75' from the shoreline in lieu of the required 100'
setback;
2. Absorption field to be located P from the easterly property line in lieu of the
required 10' setback;
3. Fuji Clean ETU to be located 4' from the house in lieu of the required 10' setback;
4. Fuji Clean ETU to be located 2.5' from the property line in lieu of the required 10'
setback;
5. Grinder Pump to be located 33.5' from the shoreline in lieu of the required 50'
setback;
6. Force Main to be located 34' from the shoreline in lieu of the required 50' setback;
7. Force Main to be located 1.5' from the house in lieu of the required 10' setback;
8. Effluent Sewer to be located 6' from the house in lieu of the required 10' setback;
9. Effluent Sewer to be located 5' from the property line in lieu of the required 10'
setback;
10. Effluent Pump Station to be located 3' from the house in lieu of the required 10'
setback; and
11. Effluent Pump Station to be located 2' from the property line in lieu of the required
A
10' setback;
on property located at 113 Rockhurst Road in the Town of Queensbury, and
WHEREAS,the Town Clerk's Office published the Notice of Public Hearing in the Town's
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
variance requests on Monday, October 17t', 2022, and
WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners
within 500 feet of the subject property,
NOW,THEREFORE,BE IT
RESOLVED,that
1. due to the nature of the variances, the Local Board of Health determines that the
variances would not be materially detrimental to the purposes and objectives of this
Ordinance or other adjoining properties nor otherwise conflict with the purpose and
objectives of any Town plan or policy; and
2. the Local Board of Health finds that the granting of the variances is necessary for the
reasonable use of the land and are the minimum variances which would alleviate the
specific unnecessary hardship found by the Local Board of Health to affect the
Applicant; and
BE IT FURTHER,
RESOLVED, that the Local Board of Health hereby approves the application of the
Lorraine W. Dickinson Trust for variances from the Sewage Disposal Ordinance to install a
replacement septic system with the:
1. Absorption field to be located 75' from the shoreline in lieu of the required 100'
f,
setback;
2. Absorption field to be located 1' from the easterly property line in lieu of the
required 10' setback;
3. Fuji Clean ETU to be located 4' from the house in lieu of the required 10' setback;
4. Fuji Clean ETU to be located 2.5' from the property line in lieu of the required 10'
setback;
5. Grinder Pump to be located 33.5' from the shoreline in lieu of the required 50'
setback;
6. Force Main to be located 34' from the shoreline in lieu of the required 50' setback;
7. Force Main to be located 1.5' from the house in lieu of the required 10' setback;
8. Effluent Sewer to be located 6' from the house in lieu of the required 10' setback;
9. Effluent Sewer to be located 5' from the property line in lieu of the required 10'
setback;
10. Effluent Pump Station to be located 3' from the house in lieu of the required 10'
setback; and
11. Effluent Pump Station to be located 2' from the property line in lieu of the required
10' setback;
on property located at 113 Rockhurst Road in the Town of Queensbury and bearing Tax Map No:
227.9-1-7, and
BE IT FURTHER,
RESOLVED, that the Enhanced Treatment Unit (ETU) shall be maintained by the property
owner in accordance with the manufacturer's recommendations for the life of the system, and
BE IT FURTHER,
RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by
certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review,and
Y
r+r
BE IT FURTHER,
RESOLVED, that this approval Resolution shall not be effective until 30 days after such
notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park
Agency during such period.
Duly adopted this 17`h day of October,2022,by the following vote:
AYES : Mr. Metivier,Mr. Ferone,Mr. McNulty,Mr. Strough
NOES : None
ABSENT: Mr.Freer
SEPTIC DISPOSAL PERMIT Office Use Only
APPLICATION Permit#:, �GP— e5t2_-Z0 2Z
Town 0r(L1x6)'xh(!ry -Permit Fee:$
E Eril 1
pnp�oide#: D
r
742 Bay Road,Queensbury,NY 12804 -2
P:518-761-8256 www.gueensbury' .net OCT 21 2 Septi Varl nce \(DON .2—
022 1 JU
� ) 1. -
t— Flood zone? No t—
TOVVN77;:� I
OF OL'EEM3BLIF!lWet ands? No Reviewed By:
BUILMNIG & ( nn;p= _J
Project Location: 113 ROCKHURST
Tax Map#: 2-27.9-1-7
RESIDENCE INFORMATION:
Year Built Gallons #of bedrooms: X gallons per =total daily flow
I per day bedroom Garbage Grinder Yes No
1980 or older 150 Installed? (choose one) F1 Fx_1
1981-1991 130 Spa or Hot Tub Yes No
1992-Present' 110 3 110 330 Installed? (choose one)
PARCEL INFORMATION:
Topography ,Flat Rolling E] Steep Slope % Slope
Soil Nature X Sand El Loam E] Clay E] Other, explain:
Groundwater At what depth? >4811
Bedrock/Impervious material At what depth? >481.1
Domestic Water Supply 7 Municipal F-1 Well *Lake
(if well or lake, water supply from any septic system absorption is
ft.)
Percolation Test Rate: 6-7 per minute per inch (test to be completed by a
licensed engineer/architect)
PROPOSED SYSTEM INFORMATION:
Tank size E.T.U. gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or
spa/hot tub -
System Absorption field w/#2 stone Total length ft.; Each Trench
Seepage Pit w/#3 stone How many: Size:
Alternative System Bed or other type: 13X24 WITH CHAMBERS.
Holding Tank System Total required capacity? tank size
# of tanks
Septic Application Revised July 2022
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
Applicant:
Name(s): LORRAINE W,DICKINSON TRUST iJOHN DICKINSON)
Mailing Address, C/S/Z: 239 VAUGHN ROAD,HUDSON FALLS,NY 12839
Cell Phone: 518-858-6017 Land Line:
Email: johndickinson76@gmail.com
• Primary Owner(s):
Name(s): SAME AS APPLICANT
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
❑ Check if all work will be performed by property owner only
• Contractor:
Contact Name(s): ELLWORTH&SON EXCAVATING INC,
Contractor Trade: EXCAVATION&INSTALLATION
Mailing Address, C/S/Z: 78 ELLSWORTH LN EXT„LAKE GEORGE,NY 12845
Cell Phone: Land Line: 518-792-9246
Email:
"Workers' Comp documentation must be submitted with this-application"
• Eneineer(s):
Name(s): HUTCHINS ENGINEERING PLLC
Mailing Address, C/S/Z: 169 HAVILAND ROAD
Cell Phone: Land Line: 518-745-0307
Email: thutchins@hutchinsengineedng.com
Contact Person for Compliance in regards to this project: CONTRACTOR AND/OR ENGINEER
Cell Phone: Land Line:
Email:
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon
any material representation or failure to make a material fact or circumstance known by or on
behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all
requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
PRINT NAME: / 1 1cF- fiV
SIGNATURE: DATE: 1/22—
Septic Application Revised July 2022
TOWN OF QUEENSBURY
742 Bay Road, Queensbuq, NY. 12804-5902
Septic System Checklist
Plan to scale
Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and
Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects)
kt)All wells on property and adjacent properties shown-
Water line shown Municipal or well 10'separation to any part of system
Setback to property lines show 10'or more for any part of system r-2-�,t-AC VAC Z-- �
1\t Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10' from any waterline,,
ANeptic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank
for 0,Separation required(field verification required)
Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each
Leech Field 20'from foundation 100'.from any well 10'from water line-
ii�i- 1
�l4eepage pit 150'from well 50'from septic tank
144-Seepage Pits 3-times diameter apart
Septic tank and pump stations over 30 gallons 50'from watercourse or wetland4. -
distance from bottom of trench or system 2r to bedrock or mot in 1000'of Lake George
1 j Leech field 100'from watercourse or wetland
)s Oe of mound or bottom of retaining wall 10'from property line 100'from well 20'from
Foundation
Provide Engineer/Architect stamp for bed or design systems
�MDepartment of Health Approval for all mobile home park new systems Flood Plain requirements
k-02'above established flood elevation to bottom of system
Lall tanks anchored or 2'above flood elevation
Ao.AoaA eit s�n�t
SERVICE CONTRACT
FORTHE
FUJI CLEAN TREATMENT TECHNOLOGY
Ellsworth & Son Excavating, Inc. has been contracted by Fuji Clean USA and their Authorized Distributor to provide
you with the first two years of service,maintenance,and operation as well as any warranty service should it be required.
This contract has been paid in full on your behalf. This contract is provided in accordance vAth applicable state and
local regulations.
This contract,entered into between,Ellsworth &Son Excavating, Inc. and shall be binding upon both
parties in accordance with the conditions and terms set forth below:
Contract Date: ili f
Term of Contract: 2 years
Location of Technology: property address: 113 Rockhurst Road, Queensbury,NY 12804
Model: Funclean CC5
MaIrAenance and Other Services shall consist of:
a. Inspection,Maintenance, and Operation: Service Provider agrees to inspect, maintain and operate the Fuji
Clean treatment system per,the TN DEC and manufacturer's requirements.This includes but is not limited
to the following:
two service visits per year (6-month intervals), Service visits will include performance of
operation and maintenance activities detailed in the Operation and Maintenance manual"
- check the sludge depth to determine the need for I)Urnping;
- inspection of the final effluent to determine proper operational performance;and
- test the process parameters including but not limited to DO,pH,and turbidity to maintain proper
operation,
b. Service Calls" Service Provider will provide services calls within two business days, Service Provider will
apply a charge for labor,travel time and shipping for any necessary replacement pails unless covered by
the manufacturers warranty,
c� Completed inspection form will be submitted to local and state authorities as required.
d. Contract is transferable in the event of sale of the home.
The owner of the system agrees to use the system as outlined in the owner's manual.The owner also understands that
any abuse of the system may void the manufacturer's walTanty.
Owner acknowledges that the following items can overtax the biological process of the system and shall avoid
introducing dental floss, disposable diapers, kitty litter,sanitary napkins,tampons, cigarette butts, condoms and other
items of similar nature. Owner acknowledges that the following can destroy the biological process and agrees to not
introduce chemicals such as paints, varnishes,thinners, waste oils, photographic solutions, pesticides and excessive
amounts of household chemicals into the system. The owner acknowledges that violation of these terms will void the
manufacturer' wartgnty an be in v' I t' f state law.
Homeowner: Date
Service Provider,,,, Date
{Authorized Agent)
Please sign and return to the Service Provider whose name and address appear below:
Ellsworth & Son Excavating, Inc
10302 State Route 149
Fort Ann, NY 12827
masnNG PUMP STATION
LAKE WATER 227.9 -1- 8 TO BE REMOVED
L SUPPLY Lands N/F of EXISTING ANTIQUATED
Lambert's Landing LLC SEPTICTANKTO SE "MOVED
8:5023 P:173
PROP. 4" PVC SCH-40
Lake _ HouSESEWER
O N -► IA
cNc� 5 ± CIRF ° ' " E So PallFe ce ell
r- 66.27' CIRF
Geo e
g LAKE WATERINTAKE / � p
APPROlill LOCATION % 0 O
28" mlk f
Sand 1 , 1W P.L SEM#%CK �►
J' ! t Patio
Bay l jJj 32" He ock
WL
WL
- WL W
4L WL '
l _ ..... ..._uL WL I
V I Z
1 2 "fie ock
I v ° /
LL
Con rete C
FF=3 .02'
e
/ l ;v o
hoUlse
Y E
/ (.0
L
1 (�!
��
c ` LL
�, v -Z e ! J`
h OI
v *+ I
A/C
OV
ck .
84-
/q)
I j
__f I
\ � FF=32�73'
227.9-1-7 a
\ CD 113 Rockhurst Road I =
crj f Lands of C �•
! n4c to vi
cD Lorraine Dickinson , N I
I
QD
8:1161 P:58 C !
1 Lr) �.
�, LAKE TER I c
/ t\ I h
SUPPOLY - . a_....
1 f o •2: a �• q
p
Ov
hss.
Dock ty s �° ro sNo
I� n RE,
Area V� ° .t
114601 Sq. Feet _ /
I�
0. 3 Acres ju
I
PROP. F1131CLEA1111, CE-S
ENHANCED TREATMENT UNIT
PROP. 4" PVC SCH-40
EFFLUENT SEWER
f
Jjj jJJ [t It1t I / ,4' ti0 • � i a t � i`} l � } �,� } i
i'a
Illjjj Con ete
Q S
PROP.1.5"HDPE t } ;i1';=i
FORCEMAIN, PROVIDE ! 33•5- S 1 '' i } t 1 } } '} `} • s ; " }t .
T BURIAL DEPTH D hed . " { 1 1 ; ; } ! 2 {
11j�t �",1is'
PROP. 406ALPOLYj i"�4t}k='t}}fit}22}} y `{
2'• i1}•i {}s`�111 �1 t 2 it { y}{{ii•y 4i}'
PACKAGED GRINDER ! I i}{? j ' }i{,' `' i `} �i•}}t{1 t;4fki` t'-2}
PUMP STATION FF= 0.44' I i ; 4 #} t Lt'•., 1 1 • { }.it 4 { t i't } i
V�\�}}', i� }}'
,. #}2..-}E
PROP.4 PVC SCH-40 {�t}-{f }}!" �'{} °} i •1�}.ii}� S 41z; }2}.52 i,S
Pu H use p ► {•� i�1 4� } { •�} 1. }�
HOUSE SEWER BUNK
}f 1l{t � �`tt�l � �.• t s{
# i i } � � j} }
\} � it, }. �}�� � � . � ' �SS j • } t.t �j •11., i y a s . :: I' i
ei 2..{f.g t } } i.X} {}-i2E f}j
}�LI)•1.�{}}�� }�}'� 1 i {� }t 21
!t0�,,V
ch }• }'. }.��} tFt� ���"1 �kz i,- t. �l i 21� � ,2,� t s 1,'}t�}. { �t {• 1
91.95
' Split it Fe e I } , i � ,.�, i � ` { ..;'� v }���� 1A'`, i } OO
----c- AL}
91± IPF m T N 79°00'00" W CIRS .t�'i�#':��.iis-�. {
° 227.9-1-6 '`{,',�t4=` `'F' ,;';i
LAKE WATER 111 Rockhurst Road
SUPPLY Lands N/F of
John & Carolyn Swan
B:5107 P:35
WASTEWATER SYSTEM PLAN
SCALE: 1 "=10'
GRAPHIC SCALE
5 0 2.5 5 10 20
( IN FEET )
CIRF NM 1 7
Shed
1 2" Spruce
PROP. IWO GAL HEAVY DUTY
PRECAST CONCRETE EFFLUENT
PUMP STATION WITH SALCOR
UV DISINFECTION
227.9-1-9
114 Rockhurst Road
Lands of
Carl & Michele Weiner
B:4226 P:265
LAKE WATER
SUPPLY
227.9-1-10
112 Rockhurst Road
Lands N/F of
Eric K Cottrell
8:1441 P:102
A/C
Fireplace
PROP.13'W x 2WL CRUSHED
STONE ABSORPTION BED WITH
(3) ROWS OF (3)- 34" WIDETRAFFIC RATED
OPEN -BOTTOM GRAVELLESS CHAMBERS
One 5tory Wood
Frame House
Propane Tanks
00
a v
Concrete
a�
11 V C
Stockade Fence
Garage
LAKE WATER
SUPPLY
1�
VERTICAL DATUM
NORTH ANERICAN VERITCAL DATUM OF 1929 (NGVD29)
SEPTIC VARIANCE SUMMARY
1. ABSORPTION FIELD TO SHORELINE
100' REQUIRED
75'PROPOSED
25' OF RELIEF REQUESTED
2. ABSORPTION FIELD TO EASTERLY PROPERTY LINE
10' REQUIRED
P PROPOSED
9' OF RELIEF REQUESTED
3. FUJI CLEAN ETU TO HOUSE
10' REQUIRED
:Playhouse',
4' PROPOSED
6OF RELIEF REQUESTED
4. FUJI CLEAN ETU TO PROPERTY LINE
10' REQUIRED
Z.5' PROPOSED
7.5' OF RELIEF REQUESTED
5. GRINDER PUMP TO SHORELINE
50' REQUIRED
33.5' PROPOSED
16.5' OF RELIEF REQUESTED
6. FORC U44IN TO SHORELINE
50' REQUIRED
34'PROP06ED
16' OF RELIEF REQUESTED
7. FORCEMAM TO HOUSE
-
10' REQUIRED
1.5' PROPOSED
8.5' OF RELIEF REQUESTED
& EFFLUENT SEWER TO HOUSE
10' REQUIRED
6'PROPOSED
4' OF RELIEF REQUESTED
9. EFFLUENT SEWER TO PROPERTY LINE
10' REQUIRED
5'PROPOSED
5' OF RELIEF REQUESTED
10. EFFLUENT PUMP STATION TO HOUSE
10' REQUIRED
3'PROPOSED
`
7 OF RELIEF REQUESTED
11. EFFLUENT PUMP STATION TO PROPERTY LINE
10' REQUIRED
2'PROPOSED
7 OF RELIEF REQUESTED
�I
T+.
k
NO
• & •
19
} M
M
4
Ate!
'N
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
Based on our limited examination, compliance
with our comments shall not be construed as
indicating the plans and specifications are in
New i with the Building Codes of j
SITE LOCATION) NEIGHBORHOOD MAP
FILE COPY
227.9-1-7 SEP-0582-2022
Lorraine Dickinson Trust
113 Rockhurst Rd
Septic Variance/Alteration
WASTEWATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELL
WATERLINE
HOUSE
LAKE
GEORGE
SEPTIC TANK, PUMP
STATION, FORCE
10,
50'
10,
10,
50'
MAIN, EFFLUENT
SEWER
ABSORP77ON FIELD
10,
100'
10,
20'
100,
Dig Safely.
New York
■ Cali Before You Dig
■ Walt The Required Time
■ Confirm Utility Response
TAX MAP # 227.9-1-7
■ Respect The Marks
■ Dig VIM Caro
800.962■7962
1
ADDED APPROVAL RESOLUTION (SHEET S3) - ISSUED FOR PERMIT
1012012022
0
ISSUED FOR SEPTIC VARIANCES
911612022
www.digeafelymwyark.com
No.
Revisions
Dote
WASTEWATER SYSTEM PLAN
prepared for.
Lorraine W Dickinson Trust
113 Rockhurst Road
Town of Queensbury, County of Warren, State of New York
MAP REFERENCE:
BASE MAP INFORMATION FROM "MAP OF A SURVEY
MADE FOR JOHN AND DAWD DICKINSON," IN THE
TOWN OF QUEENSBURY, WARREN COUNTY, NEW
YORK, DATED FEBRUARY 2, 2022. PREPARED BY.
an Du s e
&
Stever
Land Surveyors
189 Havlland Road Queenabury, New York la"
(518) 792-8474 New York Lie. No. 50135
�4F VV
S E
`_
�� N `_
�� ,Ig ,
s�o o a b
AL•TER0 A E T EXCEPT
BY A LICENSED FESSIONAL ENGINEER
IS A VIOLATION OF NYS EDUCATION LAW.
Drawn: JRS/LWD
Checked: GTH
Scale: NOTED
Date: 81412022
169 HaWland Road
Queensbury, NY 12804
(518) 745-0307 Phone
Hutchins Engineering PLLC (518) 745-0308 Fax
�"2000-0 � -�
Y
WASTEWATER SYSTEM DESIGN
3-BEDROOM RaIDENCE DESIGN BASIS
WATER SAVING FIXTURES
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
PRETREATMENT TANK - FUJICLEAN MODEL CE-5 E.T.U.
GRINDER PUMP STATION - 100 GAL PACKAGED POLYETHYLENE BASIN
GRINDER PUMP TO BE LIBERTY PROVORE PRG-100 SERIES,
22OV, 1 HP OR APPROVED EQUIVALENT, TO BE INSTALLED
AT LAKESIDE BUNKROOM
EFFLUENT PUMP STATION - 1000 GAL PRECAST CONCRETE, HEAVY DUTY
W/bUPLEX ALTERNATING PUMPS & DEMAND DOSING
DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON
6-7 MIN/IN PERCOLATION RATE
(BLEND OF NA71VE & FILL SOILS)
ABSORP7ION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF)
= 413 SF
33% E T. U. REDUCTION AREA REQ'D = 277 SF
ABSORP71ON Bm AREA PROVIDED = 13 z24' = 312 SF
W17H THREE ROWS OF (3) H-20 34-W INFILTRATOR CHAMBERS
WASTEWATER SYSTEM FILL
MATERIAL NOTES
AFTER REMOVING ORGANICS, TOPSOIL & DEBRIS, PLACE SYSTEM
FILL OVER THE ENTIRE AREA OF PROPOSED ABSORP7ION BED AND
TAPER AREA.
"ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY
SELECTED SAND OR SANDY LOAM WITH IN -PLACE PERCOLA71ON
RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3"
IN SIZE. LESS THAN 10% BY WEIGHT SHALL BE FINER THAN
0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE
IN THE RANGE OF 0.50mm TO 2.0mm. LESS THAN 15% OF THE
MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE.
ABSORPTION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED
TO PROVIDE MINIMUM OF 3-FEET BETWEEN BOUNDARY CONDITION
AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL
SHALL BE INSTALLED THROUG
HOUT THE ABSORP77ON BED AREA
AND TAPER AREAS.
ABSORPTION AREA SYSTEM FILL MATERIAL IS TO BE
MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT
PRIOR TO INSTALLA71ON OF ABSORPTION TRENCHES.
INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF
SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
1/4- PER FOOT 2-
MIN. SLOPE _
4" PVC SCH-40 HOUSE SEWER
59-
CHAMBER
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE
WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND
ASTM F481 INSTALLATION OF THERMOPLAS71C PIPE AND CORRUGATED TUBING IN
SEP77C TANK LEACH FIELDS
AFTER PLACEMENT OF SYSTEM FILL AND EXCAVATION OF 13' MDEj X 30' LONG
ABSORP7ION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE
CLEANED AND RAKED W ORDER TO LOOSEN SMEARED AREAS OF SOIL.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL
BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE
GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT
CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR 07HER
UNSUITABLE CONDITIONS. PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES.
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT
SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING
HAS BEEN INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON
THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110
GPD PER BEDROOM. THE SYSTEM 1S NOT DESIGNED TO ACCOMMODATE EXTREME
WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIX77JRES OR
EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS
WASTEWATER TREATMENT SYSTEM.
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE
EXCLUDED FROM THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT
SURFACE RUNOFF AROUND ABSORP7ION FIELD.
SEPTIC TANK, PUMP STA71ON & ABSORP71ON BED MUST BE INSPECTED BY TOWN
OF QUEENSBURY BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO
BACKFILL AND FINAL GRADING. IT 1S THE RESPONSIBILITY OF THE ;CONTRACTOR
TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS.
SYSTEM MATERIAL SPECIFICATIONS
34" WIDE OPEN -807 TOM GRAVELLFZ CHAMBER
OPEN -BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH CAPACITY.
HOUSE SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE.
FORCEMAIN
PIPING TO BE 2" SDR-26 PVC. MAINTAIN 3' MINIMUM COVER AND POSITIVE
DRAINBACK TO PUMP STATION.
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4- TO 1-1/2- WASHED CRUSHED STONE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATF
MIRAFI 140N OR EQU
IVALENT E FILL MATERIAL
FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED IN "FILL
MATERIAL NOTES."
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER EN71RE ABSORPTION FIELD AREA. SEED AND
ESTABLISH TURF.
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL SALCOR ULTRAVIOLET
TREATMENT UNIT
1/8- PER FOOT
MIN. SLOPE
4" PVC SCH-40 EFFLUENT SEWER
TER 2
CONTACT CIiAMB 3
CHAMBER AEROBIC CO TACT < -
LTRATION BER
FUJI CLEAN USA MODEL CE-5
ENHANCED TREATMENT UNIT
MAINTENANCE CONTRACT NOTE
A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM
OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED
FOR SEMI—ANNUAL INSPECTION AND SERVICE OF THE
FUJICLEAN CE-5 ENHANCED TREATMENT UNIT.
ALARM 3" ABOVE ''PUMP ON'
& LAG PUMP ON
°
FLOAT SWTCHES - PUMP ON
INSTALL INSIDE PUMP PIT
IN LOCA77ON ACCESSIBLE
107HOUT PIT ENTRY PUMP OFF
VOLUME OF DOSE TO
BE 80± GALLONS
POLYETHYLENE EXTENSION &
TAMPER RESISTANT COVER
7RANS177ON TO 4" PVC
1/4" PER FOOT
MIN. SLOPE
16" MIN.
BALL CHECK VALVE
28" DIA.
40 GALLON
POLYETHYLENE
PUMP STATION
EXTERIOR WEATHERPROOF CONTROL PANEL, ALARM &
WATER SHUT -DOWN RELAY, MOUNTED ON SIDE OF
HOUSE, IN COORDINATION WITH OWNER. SEAL CONDUIT
WEATHER77GHT. ALL ELECTRICAL WORK TO BE INSPECTED
BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR
TO START-UP OF PUMP STATION.
2" HDPE
FORCEMAIN
2" SCH-40 PVC PIPING INSIDE
WET WELL THROUGH BASIN WALL
REDUCING TEE POINTED DOWNWARD
WITH 1" BALL VALVE THROTTLED TO
ALLOW TRICKLE DRAIN BACK INTO
WETWELL
UNION - LOCATE SUCH THAT
UNION CAN BE DISCONNECTED AND
PUMP REMOVED WITHOUT TANK
ENTRY
NORMAL LIQUID LEVEL±
SIMPLEX GRINDER PUMP
GRINDER PUMP STATION DETAIL
NTS
PUMP STATION NOTES
SEAL ALL TANK OPENINGS WATERTIGHT.
PROVIDE AND INSTALL UL LISTED PACKAGED PUMP
CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM.
INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL ON THE
SIDE OF HOUSE IN COORDINA71ON WITH OWNER.
PROVIDE HIGH -ALARM FLOAT WITH LOCAL AUDIOVISUAL
ALARM..
INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH
ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.E.C.)
REQUIREMENTS.
PUMP CONTROL AND FLOAT LEVEL TO BE INSTALLED TO
PROVIDE A 15 GALLON DOSE.
GRINDER PUMP PACKAGE TO BE LIBERTY PROVOKE 380
SERIES, 115V, 1 HP OR APPROVED EQUIVALENT.
VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO
PURCHASING PUMP.
ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED
ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF
PUMP STA770N.
4" MIN. TOPSOIL, ( 4, ROADWAY
SEED, MULCH & Z
ESTABLISH TURF 13' BED WIDTH I �-
8- MIN. GRANULAR BACKFILL W
4' CHAMBER SPACINGT_ r 4" a -
.. . . . . .. . . . . . . . . . . . . . . . . . . . . . . ..... . . . . . . . .
N
_ _
.._.... ;'• ,'•'. ...
t�3
L
. • .•�j��v��,--n n T-���,-. >�+-��>�-�,� .12 TIT ' :••;24 . .
_ _ _.
5` -
:
r �:
:•
IN
: •:' _ -'- _, _
;••EXCAVATE NATIVE SOILS TO' . -
6-'
5 TO THE WEST OF -'. f
. '.
ABSORPTION FIELD
.. - -
r
.. ...•..: ' .
.
. ' . . • . .
' � ' • ' • '' : �• �..•3B MIN : •
_......; - ::._........__... 1. .. ..' ..' .;' .; .. EXCAVATE NATIVE SOILS AND DEBRIS:iO. ••: ,•:;': • : •: ,•: •: • : ,'' . ,'•: •'•'. ;• . ,•'. •'•`. ;•: ,'•'. •'• .. : •'•'.;' . •'.;''::':;'' .;'•: , .:•:SEPARATION : ;•
_.._. 3' BELOW A T) FIELD '•': '• . '•': •': '' : '' . '• . '' : '• . '• : '': '•': '• : '•': '''.TO BOUNDARY '.'•....._:: -
BSORP ON
REPLACE.WLTN SYSTEM FILL . •. . •.• . .,•.• ., ., . •. •., •. •. . •. . •. •.••.;•.••..•.••. •. . •.;•..•.;•..•..•. •. •.. CONDI7TON:.•'''
....
1
.
SYSTEM SAND FILL, FILTER FABRIC 4" PVC INTO END INFILTRATOR H-20 ABSORP71ON BED
STABILIZED IN 1-FT LIFTS, CAP OF CHAMBER CHAMBER PER PLAN STONE AGGREGATE
PRIOR TO INSTALLING FIELD
ABSORPTION FIELD SECTION
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL FLOAT
SWITCHES TO OPERATE
PUMP AND MAINTAIN
LEVELS AS INDICATED
4.
BALL VALVE --
INSTALL VALVES AND
UNIONS SUCH THAT EITHER
PUMP CAN BE ISOLATED
AND REMOVED WITHOUT
REQUIRING PIT ENTRY
BALL CHECK VALVE - ,
FLOAT SWITCHES -
INSTALL INSIDE PUMP PIT
IN LOCA71ON ACCESSIBLE
WITHOUT PIT ENTRY
1,000 GALLON PRECAST CONCRETE PUMP STATION
FUJI CLEAN ENHANCED TREATMENT UNIT & PUMP STATION DETAIL
NTS
NTS
EXTERIOR WEATHERPROOF JUNCTION BOX
(IF NECESSARY). SEAL CONDUIT GAS
77GHT. INSTALL CONTROL PANEL IN
HOUSE ALL ELECTRICAL WORK TO BE
INSPECTED BY A CERTIFIED ELECTRICAL
INSPECTION AGENCY PRIOR TO START-UP
OF PUMP STATION.
2" MIN. DROP
DISTRIBUTION BOX F BETWEEN INVERTS
SALCOR UV DISINFECTION UNIT
ELECTRICAL JUNC71ON
BOX NTH INDICATORS—.,
AND ALARM CONTACTS
GROUND LEVEL
DISINFECTION
SUB - ASSEMBLY
SALCOR UV DISINFECTION UNIT
NTS
1— 34" CHAMBER QUID TH
INFILTRATOR H-20
CHAMBER SECTION
NTS
iMBER
HT
750 EFFECTIVE LENGTH I
INFILTRATOR H-20 CHAMBER PROFILE
NTS
°
TRANSITION TO 4"
OUTSIDE OF D-BOX
CONCRETE BAFFLE 2" MIN.
USE SPEED LEVELERS TO ASSU7AT
ALL OUTLETS ARE TAX MAP # 22Z 9-1-7
EXACTLY THE SAME ELEVA71
SOLID
HEADER"TOVMANIFOLD5PIPING Dig INSafely.
1/8- PER FOOT MIN SLOPE New/,York
1-1/2- HDPE PUMP STATION NOTES ■ Call Before You Dig
SDR-11 FORCEMAIN ■ Wait The Required Time
SEAL ALL TANK OPENINGS WATERTIGHT. ■ Confirm Utility Response
2" SCH-40 PVC PIPING 0 Respect The Marks 1 ADDED APPROVAL RESOLU77ON (SHEET S3) - ISSL
INSIDE WET WELL THROUGH WALL PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL ■Dig with Caro
PANEL WITH VISUAL AND AUDIBLE ALARM. INSTALL DUPLEX, 800 962 7962 0 ISSUED FOR SEPTIC VARIANCES
—
UNION - LOCATE SUCH THAT ALTERNATING, DEMAND DOSE CONTROL PANEL INSIDE HOUSE aigsafelyrwwyork.com
N o. Revisions
UNION CAN BE DISCONNECTED AND IN ACCESSIBLE LOCATION, SJE RHOMBUS IFS SINGLE PHASE
PUMP REMOVED WITHOUT TANK DUPLEX DEMAND DOSE CONTROLLER. N E I
ENTRY �Ps WASTEWATER DETAIL
REDUCING TEE POINTED DOWNWARD INSTALL POKER & CONTROL WIRING TO CONTROLLER WITH �Q` p� T for.,
WITH 1- BALL VALVE THROTTLED TO ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURERS �'� �� .� prepared
ALLOW TRICKLE DRAIN BACK INTO INSTRUCTIONS AND NATIONAL ELECTRIC CODE (N.E.C) r CD � a � Lorraine W Dickinson T
REQUIREMENTS. ! - �'
WETWELL m z 113 Rockhurst Road
GOODS WE05H EFFLUENT PUMP CONTROL AND FLOAT LEVELS TO BE. INSTALLED TO Town of Queensbury, County of Warren, S
PUMPS (DUPLEX) ALTERNATE PUMP DOSING AND TO PROVIDE AN 80 GAL DOSE p 0678?9
i°RpF Drown: JRS/LWD Checked: GTH ScoJe: MOTEL
PUMPS TO BE GOULDS MODEL 3885, WE05H 23OV, SINGLE PHASE,
35 GPM PUMP AT 30 FT TDH. een Havi, N Roc
ALTERATION OF THIS DOCUMENT EXCEPT Quensbury, NY 1:
VERIFY ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. BY A LICENSED PROFESSIONAL ENGINEER (518) 745-0307 Ph
16- CHAMBER
HEIGHT
TOWN OF OUEENSBURY LOCAL BOARD OF HEALTH APPROVAL RESOLUTION - BOH 81, 2022
10' setback;
setback;
BE TT FURTHER,
2. Absorption field to be located 1' from the easterly properly Line in lieu of the
RESOLUTION APPROVING LORRAINE W. DICKINSON TRUST'S
APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES
on properly located at 113 Rockhurst Road in the Town of Queensbury, and
required 10' setback;
RESOLVED, that this approval Resolution shall not be effective until 30 days after such
3. Fuji Clean ETU to be located 4' from the house in lieu of the rewired 10' setback;
notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park
WHEREAS, the Town Clerk's Office published the Notice of Public Hearing in the Towns
4. Fuji Clean ETU to be located 2.5' from the property fine in lieu of the required 10'
Agency during such perm.
RESOLUTION NO.: BOH 8!, 2t12Z
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
setback;
INTRODUCED BY: Mr. Anthony Meiivier
WHO MOVED ITS ADOPTION
variance requests on Monday, October 170, 2022, and
5. Grinder Pump to be local 33.5' from the shoreline in lieu of the required 50'
Duly adopted this 17` day of October, 2022, by the following vote:
setback;
SECONDED BY: Mr. George Ferone
WHEREAS, the. Town Clerk's Office has advised that it duly notified all property owners
6. Force Main to be located 34, from the shoreline in lieu of the required 50' setback;
AYES : W Metivier, Mr. Ferone, Mr. McNulty, Mr. Strough
within 500 feet of the subject property,
7. Force Main to be located 1.5' from the house in lieu of the required 10' setback;
NOES :None
`
WHEREAS, the Lorraine W. Dickinson Trost (Applicant) filed an application for variances
8. Effluent Sewer to be located 6' from the house in lieu of the required 10' setback;
ABSENT: Mr. Freer
from provisions of the Town of Queensbury On -Site Sewage Disposal Ordinance, Chapter 136 to
NOW, TEIEREFORE, BE IT
9. Effluent Sewer to be located 5' from the property line in lieu of the required 10'
setback,
install a replacement septic system with the:
RESOLVED, that
10. Effluent Pump Station to be located 3' from the house in lieu. of the required 10'
1. Absorption field to be located 75, from the shoreline in lieu of the requires 100'
1. due to the nature of the variances, the Local Board of Health determines that the
setback' and
11. Effluent Pump Station to be located 2' from the property line in lieu of the required
_
l' 6* 00ft D VM Oak of the Tom of Oovdft qbt m wit
setback;
NewYotk do heft wftftihave comparedNfM tab IN
variances would not be materially detrimental to the purposes and objectives of this
10' setback;
odgitrdf rtotitates 9skd �0 al
AladataS,(, !!•Y' moo
2. Absorption field to be looted F from die easterly property line in lieu of the
Ordinance or other adjoining nor otherwise conflict with t and
of a Town Board of the Toth � Ythe t"p't''" daf►a
�tY
properties purpose
�, 0twhkb�aW=W8$ Ittatd&9iho
required 10' setback;
objectives of any Town plan or policy; and
on property located at 113 Rockhurst Road in the Town of Queensbury and bearing Tax Map No:
sane b a CWW i ptli rom xW of tle M" tdrW
to ddk
3. Fuji Clean ETU to be located 4' fromthehouse in lieu of the required 14' setback;
2. the Local Board of Health fads that the granting of the variances is necessary for the
227.9-1-7, and
W S' 1 htllre1 0 hand ate At. of ttetd?t�rt1
4. Fuji Clean ETU to be located 2.5' from the property line in lieu of the required 10'
l�* dIVof . 22
reasonable use of the land and are the minimum variances which would alleviate the
Wyk'
specific unnecessary hardship found by the Local Board of Health to affect the
BE TT FURTHER,
$ r
5. Grinder Pump to be located 33.5' from the shoreline in lieu of the required 50'
_ -i Y tPh!►
Applicant; and
6. Force Main to be located 34' from the shoreline in lieu of the required 50' setback;
RESOLVED, titer the Enhanced Treatment Unit shall be maintained b theproperty-
(�T� Y
- -
Tartar of Mum"
BE IT FtJR,THER,
owner in accordance with -the manufacturer's recommendations for the life of the system, and
7. Force Main to be located 1.5' from the house in lieu of the required 10' setback;
8. Effluent Sewer to be located 6' from the house in lieu of the required 10' setback;
RESOLVED, that the Local Board of Health hereby approves the application of the
BE IT FURTHER,
9. Effluent Sewer to be located 5' from the property line in lieu of the required 10'
Lorraine W Dickinson Trust for variances from the Sewage Disposal Ordinance to install a
setback;
replacement septic system with the:
RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by
10. Effluent Pump Station to be located 3' from the house in lieu of the required 10'
certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review, and
setback;and
1. Absorption field to be located 75' from the shoreline in lieu of the required 100'
11. Effluent Pump Station to be located 2' from the property line in lieu of the required
TAX MAP # 22Z9-1-7
Dig ISafely,
NewYork
N Cali Before You Dag
® Wait The Required Time
® Confirm Utility Response
M Respect The Marks
N Dig With Caw
800-962■7962
1
ADDED APPROVAL RESOLUTION (SHEET S3) - ISSUED FOR PERMIT
1012012022
www.diguafe"wyork.com
No.
Revisions
Date
of NEW r
APPROVAL RESOLUTIONS
piWared for:
�o
co
Lorraine W Dickinson Trust
ul
z
113 Rockhurst Road
Town of Queensbury, County of Warren, State of New York
os7a1
Ado
Drawn: JRS/LWD
Checked. CTH
Scale: NOTED
Dote: 8/4/2022
169 Haviland Road
ALTERATION OF I DOCUMENT EXCEPT
Queensbury, NY 12804
292000-0 —53
IS'A VIOLATION OA LICENSED FONYSSEDUCATIONENGINEER LAW.
Hutchins Engineering PLLC ((51 745-0300 Phone
g g (518) 745-0308 Fox
FF 335.5±
II
C
O r
c
NEW IS!, HOPE
FORCERAIN
;
NEW GRINDER
PUMP STATION
NEW 4" PVC
! Pu PH
use
HOUSE SEWER
I
1
L'
m ° g�± IPF m
=o
N
LAKE WATER 227.9-1.8
SUPPLY Lands N/F of
La►abert's Landing LLC
8:5023 P:173
NEW 4" PVC SCHAG
HOUSE SEWER
�--
0
227.9-1-6
LAKE WATER 111 Rockhurst Road
SUPPLY Lands N/F of
John & Carolyn.Swan
B:5107 P:35
WASTEWATER SYSTEM PLAN
SCALE: 1 "-10'
GRAPHIC SCALE
5 0 2.5 5 10 20
( IN FEET )
NEW FU31CLVAN CEN-S
ENHANCED TREATNENT UNIT
CIRF NM 1 7
f W 11C, u 5' OF RELIEF REQUE51 EU
Frame House
10. EFFLUENT PUMP STATION TO HOUSE
10' REQUIRED
3'PROPOSED
T OF RELIEF REQUESTED
11. EFFLUENT PUMP STATION TO PROPERTY LINE
10' REQUIRED
2'PROPOSED
IT OF RELIEF REQUESTED
SEPTIC VARIANCE APPROVALS
SEPTIC VARIANCES APPROVED BY THE TOWN OF QUEENSBURY
LOCAL BOARD OF HEALTH ON OCTOBER 17, 2022 UNDER
RESOLUTION BOH 81, 2022
RECORD DRAWING
INSTALLATION DATE:11/8-15/2022
INSTALLED BY - ELLSWORTH AND SON EXCAVATING INC.
TAX MAP # 227.9-1-7
Dig PSafely.
n Tan NeW�Y01'1(
} Propane ks ®��� You Db 3 RECORD DRAWING 11 18 2022
O� ■ Wan The R@*dre4 nme ' NM 6 a� �� 2 ADDED EXISTING ABSORPTION AREA PER APA REQUEST 0 1 20 2
�.. o Stockade fence °^ee
' � ' 0 Respect The Marks 1 ADDED APPROVAL RESOLUTION SHEET S3 - ISSUED FOR PERMIT 1012012022
■ DIg With Can ( )
CIRS 8�'�2'7�2 0 ISSUED FOR SEP11C VARIANCES 9/16/2022
1
Revisions Date
I.
X. of N WASTEWATER SYSTEM PLAN
. Gara6je MAP REFERENCE: �p
227.9 -1 10 BASE MAP INFORMATION FROM "MAP OF A SURVEY prepared for:
112 Rockhurst Road LAKE WATER MADE FOR JOHN AND DAWD DICKINSON," IN THE Lorraine W Dickinson Trust
Lands N/F of TOWN OF QUEENSBURY, WARREN COUNTY, NEW + J
SUPPL Y YORK. DATED FEBRUARY 2, 2022. PREPARED BY ,� 113 Rockhurst Road
Eric K Cottrell w
Town of Queensbury, County of Warren, State of New York
B:1441 P:102 Yl Du S ��ES(a
�` & OAg04 C. Np�-� Drawn: JRSI'LWD Checked: GTH Scale: 1 "--10' Date: 81412022
Steves
169 Haviland Road
Land Surveyors ALTERATION OF THIS DOCUM C Queensbury, NY 12804
189 Havilmd Road Qaesnsb,", New York 1MM BY A LICENSED PROFESSIONAL GINEER (518) 745-0307 Phone 292000-01 -S 1
(818) 792-8474 New York Lie. No. 50,35 IS A VIOLATION OF NYS EDUCATION LAW. Hutchins Engineering PLLC (518) 745-0308 Fax