TAB Report 12-21-22 22-723FIRM: MTI - Mechanical Testing, Inc. 4 Chelsea Place, Suite 102 Clifton Park NY 12065 PHONE: (518) 450-7292 FAX: (518) 450-7295 CUSTOMER: Eastern Heating & Cooling PROJECT #: 22-723 PROJECT ADDRESS: 578 Aviation Mall Road Queensbury NY DATE: 2022-12-21 CONTACT: Kevin Greenwood Planet Fitness Queensbury: Functional Training Room 4 Chelsea Pl, Suite 102 Clifton Park, NY 12065 Phone: 518-450-7292 Fax: 518-450-7295 Design Review - Commissioning - Fire Life Safety - Test And Balance - ASHRAE 110 -Drone Sales/Inspections Terms and Abbreviations     ACH​- Air Changes per Hour   AHU​- Air Handling Unit  AK​- Free Area of Duct   AVG​- Average   BHP​- Brake Horsepower   BV​- Ball Valve (Shut Off Valve)   CB​- Circuit Breaker   CBV​- Calibrated Balance Valve   CD​-Ceiling Diffuser   CFM​- Cubic Feet per Minute   CHWS​- Chilled Water System   CRAC​- Computer Room Air Conditioner   CS​- Circuit Setter   CUH​- Cabinet Unit Heater   DAT​- Discharge Air Temperature   DD​- Direct Drive (motor)  Des.​- Design   Disch​.- Discharge   DNE​- Does Not Exist   DP​- Discharge Pressure of Pump/Pressure Drop   EA​- Exhaust Air   EAV​- Exhaust Air Valve   EAT​- Entering Air Temperature   EF​- Exhaust Fan   EG​- Exhaust Grille   ERU​- Energy Recovery Unit   E.S.P​.- External Static Pressure   EWT​- Entering Water Temperature   FCU​- Fan Coil Unit   FD​- Fire Damper   FLA​- Full Load Amperage   Flow Coeff.​ –Correction Factor for Flow to VAV   Flow Hood​- Instrument that measures airflow   FPM​- Feet per Minute GPM- Gallons Per Minute   HEPA​- High Efficiency Particulate Arrestance   HP​- Horsepower   HVAC​- Heating Ventilation and Air Conditioning   HWS​- Hot Water System   HX​- Heat Exchanger   Hz​- Hertz   In.​- Inches   In. w.g.​- Inches of Water Gauge   ISDFT​- Insufficient Straight Duct for Traverse   Kfactor​- Correction factor to the free area   needed to calculate CFM.   LAT​- leaving Air Temperature   LWT​- Leaving Water Temperature   MAU​- Make Up Air Handling Unit   MAX​- Maximum set point/flow   MIN​- Minimum set point/flow   NI​-Not Installed   NIS​-Not in Scope   O/A​- Outside Air   OBD​- Opposed Blade Damper   OD​- Outside Diameter Measurement of Sheave   PH​- Phase   PSI​- Pounds per Square Inch   RA​- Return Air   RAT​- Return Air Temperature   RF​- Return Fan   RHC​- Reheat Coil   RPM​- Revolutions per Minute   RTU​- Roof Top Unit   SA​- Supply Air   SAV​- Supply Air Valve   SAT​- Supply Air Temperature   S.F.​- Service Factor  SF​- Supply Fan   SP​- Suction Pressure of Pump/ Static Pressure   Sq. ft​.- Square Feet   TAB​- Test, Adjust and Balance   TDV​- Triple Duty Valve   TP​- Thermally Protected   TSP​- Total Static Pressure   UH​- Unit Heater   V​- Volts   VAV​- Variable Air Volume Box   VD​- Volume Damper   VFD​- Variable Frequency Drive   VVT​- Variable Volume Terminal   WC​- Water Column   3 3 4 4 Table of Contents Instruments Used* Instruments Used RTU-4 RTU-4* PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY Page 2 of 8 2022-12-21 Instruments Used Instruments Used* Instruments Used INSTRUMENTS USED Name Instrument Manufacturer Model #Serial #Calibration Date Measures Tech Name Instruments Used Air Data Evergreen Telemetry S-PVF-1 2100097 9/8/22 Airflow Kevin Greenwood IMAGES: PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY Instruments Used Page 3 of 8 2022-12-21 Design Actual %Design Actual % RTU-4 RTU-4* UNIT DATA Equipment Location Roof Filter Type Throwaway Area Served Functional Training Filter Quantity 2 Unit Manufacturer Bryant Filter Size (inches)16x24x2 Unit Model No.582KE05A110A2A0AAA Performed By KG Unit Serial No.2622C06915 Pass/Fail Pass RTU-4* / Test Data* TEST DATA Total Unit CFM 1600 CFM 1626 CFM 102 O/A Damper Position 20 % Outlet CFM 1600 CFM 1609 CFM 101 R/A Damper Position 80 % Outside Air CFM 400 CFM 422 CFM 106 Discharge Air temp 134.2 deg F Return Air CFM 1200 CFM 1204 CFM 100 Hertz at Design CFM High 7.0 volts Hz Fan RPM Not Listed RPM Direct Drive RPM Test Date 12/20/22 RTU-4* / Motor Data* MOTOR DATA Motor Manufacturer See note Volts T1 460 Volts Motor Frame See note Volts T2 460 Volts Motor RPM See note RPM Volts T3 460 Volts Motor Horsepower 2.0 HP Plate Amps 1.5 Amps Motor Phase 3 Amps T1 0.90 Amps Motor Hertz 60 Hz Amps T2 0.90 Amps PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY RTU-4*Page 4 of 8 2022-12-21 Design Actual %Design Actual % Service Factor 1.0 Amps T3 0.90 Amps Efficiency 0.850 Starter Heater Electronically Protected Power Factor 0.850 Brake Horsepower 0.694 Plate Volts 460 Volts MOTOR DATA NOTES: Motor Data Motor Manufacturer There is no motor tag located on motor. Efficiency The Efficiency and Power Factor are not listed on the motor tag. MTI used the industry standard of 0.85 for each to determine an ESTIMATED BHP. RTU-4* / Drive Data* DRIVE DATA Motor Sheave/OD Size Direct Drive Fan Bore Direct Drive in Motor Bore Direct Drive in No. of Belts Direct Drive Motor Sheave % Closed Direct Drive %Belt Size Direct Drive Fan Sheave/OD Size Direct Drive Center Distance Direct Drive in RTU-4* / Test Pressures* TEST PRESSURES Total Static Pressure Not Listed in. H2O 1.02 in. H2O Pre-Filter DP Not Listed in. H2O 0.17 in. H2O External Static Pressure 0.75 in. H2O 0.85 in. H2O 113 Pre-Heat DP Not Applicable in. H2O Not Applicable in. H2O Discharge Static 0.43 in. H2O Cooling Coil DP Not Listed in. H2O 0.17 in. H2O Suction Static -0.59 in. H2O Static at Furthest VAV Not Applicable in. H2O Mix Box/Pre-Filter SP Not Listed in. H2O -0.42 in. H2O Sys. Operational Static Not Applicable in. H2O PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY RTU-4*Page 5 of 8 2022-12-21 Photo's RTU-4* / Photos PHOTO'S Unit Photo IMAGES: RTU-4* / Static Profile STATIC PROFILE Static Profile IMAGES: PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY RTU-4*Page 6 of 8 2022-12-21 PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY RTU-4*Page 7 of 8 2022-12-21 RTU-4* / Traverse Summary TRAVERSE SUMMARY Name System Location Size Area Design FPM Design CFM Average FPM Actual CFM Static Pressure Return Air RTU-4 Main RA 17x17 2.000 600 1200 602 1204 -0.030 Outside Air RTU-4 Intake 24x23 3.840 104 400 110 422 Not Applicable Totals 1600 1626 RTU-4* / Supply Outlet Summary SUPPLY OUTLET SUMMARY Name Room No.Type Size AK Factor Design FPM Design CFM Reading 1 Reading 2 Final CFM % of Design SO-1 Functional Training S-2 18x10 1.000 400 400 451 388 388 97 SO-2 Functional Training S-2 18x10 1.000 400 400 522 412 412 103 SO-3 Functional Training S-2 18x10 1.000 400 400 499 407 407 102 SO-4 Functional Training S-2 18x10 1.000 400 400 590 402 402 101 Totals 1600 1609 PROJECT NUMBER: 22-723 CONTACT: Kevin Greenwood LOCATION: Planet Fitness Queensbury: Functional Training Room 578 Aviation Mall Road Queensbury NY RTU-4*Page 8 of 8 2022-12-21