Loading...
CC-0358-2022 Office Use Only a ADDITION/ALTERATION PERMIT Permit#: GG - OAS " 20 ZZ. APT�TON Permit Fee:$ 532� Town of Queensbury 742 Bay Road,Queensbury,NY 12804 Invoice#:P:518-761-8256 www.gueensbury.net o ca co® Flood Zone? Y viewed By: i�LuO WProject Location: 578 Aviation Road v = ILL O Tax Map ID #: 302.5-1-2.11 Subdivision Name:Aviation Mall �O m PROJECT INFORMATION: TYPE: ❑ Residential ❑X Commercial, Proposed Use:A-3(EXISTING) ❑ Single-Family ❑ Two-Family ❑ Multi-Family (#of units_) ❑ Townhouse ❑ Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ) ❑ Other(describe ASSEMBLY-FITNESS CENTER ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 15,200 SF(13,600�1�600-9F) 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total sq ft: �b6�� Total sq ft:15,200 SF Scope of work to be done: SCOPE OF WORK INVOLVES INTERIOR RENOVATION OF EXISTING PLANET FITNESS. -WORK INCLUDES MINOR RECONFIGURATION OF WALLS TO INCREASE ACESSIBILITY. SCOPE OF WORK ALSO INVOLVES EXPANSION OF TENANT INTO AN EXISTING VACANT TENANT SPACE(13,600 SF EXISTING PF+ 1,600 SF EXPANSION). _ WORK INCLUDES REPLACEMENT OF LIGHTING FIXTURES TO LED FIXTURES, PAINTING AND OTHER COSMETIC UPGRADES. Addition/Alteration Application Revised March 2022 • J ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 250,000.00 2. Source of Heat (circle one): X❑ Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other: Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES IN NO Explain: 4. Are there any easements on the property? ❑ YES ® NO SITE INFORMATION: • Is this a corner lot? ® YES ❑ NO • Will the grade be changed as a result of the construction? ❑ YES ® NO • What is the water source? X❑ PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? RI SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. z 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance.with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: SHAUN N.ANDRIANO(AGENT) SIGNATURE: �i(,�.�� (,t,,,�.""-�' DATE: 06/02/2022 Addition/Alteration Application Revised March 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): PETER FANTASIA Mailing Address, C/S/Z: 35 Old Tavern Road, Orange, CT 06477 Cell Phone: 203 ) 745-9050 Land Line: �) Email: PETER.FANTASIA(oD-ECP-PF.COM • Primary Owner(s): Name(s): PYRAMID MANAGEMENT GROUP(JASON TYLER) Mailing Address, C/S/Z:578 AVIATION ROAD, QUEENSBURY, NY 12804 Cell Phone: ( _) Land Line: 518 ) 793-8818 X 105 Email: JASONTYLERAPYRAMINDMG.COM ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): TBD-WORKERS COMP PROVIDED AT ONCE CONTRACTOR SELECTED Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: �) Email: "Workers' Comp documentation must be submitted with this application" • Arch itect(s)/Engineer(s): Business Name: C2 ARCHITECTURE Contact Name(s): MICHAEL A. ROMAN Mailing Address, C/S/Z: 24 AIRPORT ROAD, SCHENECTADY, NY 12302 Cell Phone: 518 ) 320-8250 Land Line: 518 ) 320-8250 Email: ROMAN(aC2-DESIGNGROUP.COM Contact Person for Compliance in regards to this project:SHAUN ANDRIANO Cell Phone: 518 ) 320-8250 Land Line: 518 ) 320-8250 Email: AND RIANOAC2-DESIGNGROUP.COM Addition/Alteration Application Revised March 2022 COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Location: Glens Falls, New York Climate Zone: 6a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: . 578 Aviation Mall Road Planet Fitness GPI Queensbury, New York 12804 578 Aviation Mall Road Queensbury, New York 12804 Building Area Floor Area 1-Exercise Center:Nonresidential 15200 Envelope Assemblies Envelope TBD: No envelope assemblies specified WE ENEQ Fo F3� !6 y Goy R OWL B f`o Project Title: Report date: 06/23/22 Data filename: Page 1 of 8 COMcheck Software Version COMcheckWeb Interior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 578 Aviation Mall Road Planet Fitness GPI Queensbury, New York 12804 578 Aviation Mall Road Queensbury, New York 12804 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts/ft2 Watts 1-Exercise Center 15200 0.65 9880 Total Allowed Watts = 9880 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp/Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Exercise Center(15200 sq.ft.) LED:A: LED HIGHBAY: Other: 1 7 150 1050 LED: D: LED MIRROER LIGHT: Other: 1 6 32 192 LED: F: LED DOWN LIGHT:Other: 1 142 14 1988 LED:G: LED DOWN LIGHT: Other: 1 60 14 840 LED: H: LED DOWN LIGHT: Other: 1 8 14 112 LED:SM: LED WALL SCONCE: Other: 1 4 12 48 Total Proposed Watts= 4230 "Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Franklin Rapp Elec. Designer gwnfilin&PP 06/23/2022 Name-Title Signature Date Project Title: Report date: 06/23/22 Data filename: Page 2 of 8 COMcheck Software Version COMcheckWeb Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Project Type: Alteration Exterior Lighting Zone 0 (Unspecified) Construction Site: Owner/Agent: Designer/Contractor: 578 Aviation Mall Road Planet Fitness GPI Queensbury, New York 12804 578 Aviation Mall Road Queensbury, New York 12804 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/ Wattage (B X C) Total Tradable Watts(a) = 0 Total Allowed Watts= 0 Total Allowed Supplemental Watts(b) = 350 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power Exterior Lighting TBD: Exterior lighting zone not specified (see project screen) Project Title: Report date: 06/23/22 Data filename: Page 3 of 8 COMcheck Software Version COMcheckWeb Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Location: Glens Falls, New York Climate Zone: 6a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 578 Aviation Mall Road Planet Fitness GPI Queensbury, New York 12804 578 Aviation Mall Road Queensbury, New York 12804 Mechanical Systems List Quantity5ystem Type & Description Mechanical Compliance Statement. Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Report date: 06/23/22 Data filename: Page 4 of 8 COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 :Plans,specifications, and/or ;❑Complies [PR4)1 calculations provide all information :❑Does Not ;with which compliance can be :determined for the interior lighting :❑Not Observable :and electrical systems and equipment ❑Not Applicable and document where exceptions to :the standard are claimed. Information provided should include interior ;lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: Report date: 06/23/22 Data filename: Page 5 of 8 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. ;Spaces required to have light- ;❑Complies 2 reduction controls have a manual ;❑Does Not [EL22]1 ;control that allows the occupant to reduce the connected lighting load in ![:]Not Observable a reasonably uniform illumination ;❑Not Applicable ; pattern >= 50 percent. C405.2.1, ;Occupancy sensors installed in ;.[:]Complies C405.2.1. classrooms/lecture/training rooms, :❑Does Not 1 ;conference/meeting/multipurpose [EL1811 I rooms,copy/print rooms, ;❑Not Observable: lounges/breakrooms,enclosed offices, ;❑Not Applicable ; ;open plan office areas, restrooms, storage rooms, locker rooms, warehouse storage areas, and other ;spaces<= 300 sgft that are enclosed by floor-to-ceiling height partitions. Reference section language C405.2.1.2 for control function in warehouses and section C405.2.1.3 ;for open plan office spaces. C405.2.1. ;Occupancy sensors control function in ;❑Complies 2 warehouses: In warehouses,the :❑Does Not [EL19]1 ;lighting in aisleways and open areas is ;controlled with occupant sensors that ;❑Not Observable ,automatically reduce lighting power j❑Not Applicable by 50%or more when the areas are ;unoccupied.The occupant sensors control lighting in each aisleway independently and do not control lighting beyond the aisleway being !controlled by the sensor. C405.2.1. !Occupant sensor control function in ;❑Complies 3 open plan office areas: Occupant ;❑Does Not [EL20]1 ;sensor controls in open office spaces ;❑Not Observable', >= 300 sq.ft. have controls 1) configured so that general lighting can j❑Not Applicable be controlled separately in control ;zones with floor areas <= 600 sq.ft. within the space,2)automatically turn off general lighting in all control zones ; ;within 20 minutes after all occupants ; have left the space, 3)are configured so that general lighting power in each ; ;control zone is reduced by>= 80%of ; ;the full zone general lighting power ;within 20 minutes of all occupants leaving that control zone, and 4)are ;configured such that any daylight ;responsive control will activate space ; general lighting or control zone ;general lighting only when occupancy j 'for the same area is detected. C405.2.2, ;Each area not served by occupancy ;❑Complies C405.2.2. ')sensors(per C405.2.1) have time- ;❑Does Not 1, ;switch controls and functions detailed C405.2.2. in sections C405.2.2.1 and C405.2.2.2.;❑Not Observable 2 ;❑Not Applicable [EL21]z 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/23/22 Data filename: Page 6 of 8 i Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Req.ID C405.2.3, ;Daylight zones provided with ;❑Complies C405.2.3. individual controls that control the ;❑Does Not 1, lights independent of general area C405.2.3. {lighting.See code section C405.2.3 �❑Not Observable 2 i Daylight-responsive controls for ;❑Not Applicable ; [EL23]2 ;applicable spaces,C405.2.3.1 Daylight; '!responsive control function and section C405.2.3.2 Sidelit zone. C405.2.4 ;Separate lighting control devices for ;❑Complies [EL26]1 :specific uses installed per approved :❑Does Not lighting plans. :[]Not Observable; ❑Not Applicable C405.2.4, ;Additional interior lighting power ;❑Complies [EL27]1 ;allowed for special functions per the :❑Does Not ;approved lighting plans and is ;automatically controlled and ❑Not Observable; separated from general lighting. ;❑Not Applicable ; C405.3 I Exit signs do not exceed 5 watts per ;❑Complies [EL6]1 face. :❑Does Not ![--]Not Observable ;❑Not Applicable C405.6 Low-voltage dry-type distribution ;❑Complies [EL26]2 lelectric transformers meet the :❑Does Not minimum efficiency requirements of ;Table C405.6. ;❑Not Observable ;❑Not Applicable C405.7 !Electric motors meet the minimum ;❑Complies [EL27]2 efficiency requirements of Tables :❑Does Not j C405.7(1)through C405.7(4). {Efficiency verified through certification;❑Not Observable lunder an approved certification ;❑Not Applicable ; j program or the equipment efficiency ratings shall be provided by motor manufacturer(where certification programs do not exist). C405.8.2, Escalators and moving walks comply ;❑Complies C405.8.2. !with ASME A17.1/CSA B44 and have :❑Does Not 1 automatic controls configured to [EL28]2 ;reduce speed to the minimum :❑Not Observable I permitted speed in accordance with ;❑Not Applicable ASME A17.1/CSA B44 or applicable local code when not conveying ;passengers. C405.9 ;Total voltage drop across the ;❑Complies ; [EL29]2 combination of feeders and branch :❑Does Not circuits<= 5%. ;❑Not Observable; ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 06/23/22 Data filename: Page 7 of 8 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished 0&M instructions for ;❑Complies C408.2.5. systems and equipment to the ;❑Does Not 2 building owner or designated [FI17]3 representative. :❑Not Observable ❑Not Applicable ; ; C405.4.1 ;Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ;❑Does Not is shown on the approved lighting :plans,demonstrating proposed watts ❑Not Observable are less than or equal to allowed ;❑Not Applicable ; ;watts. , C408.1.1 ;Building operations and maintenance ;[]Complies ; [FI57]1 1 documents will be provided to the ;❑Does Not ;owner. Documents will cover ;manufacturers'information, :❑Not Observable :specifications,programming ;❑Not Applicable ; procedures and means of illustrating Ito owner how building,equipment and systems are intended to be installed, maintained,and operated. C408.2.5. 1 Furnished as-built drawings for ;❑Complies 1 electric power systems within 90 days ;❑Does Not [,FI16]3 of system acceptance. ❑Not Observable ;❑Not Applicable C408.3 !Lighting systems have been tested to ;❑Complies [FI33]1 ;ensure proper calibration,adjustment, T❑Does Not programming, and operation. ;❑Not Observable; ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Report date: 06/23/22 Data filename: Page 8 of 8 FIRE MARSHAL'S OFFICE TOU)n of Queensbunj 742 Bay Road, Queensbunj, NY 12804 "Hone of Natural Beauty ... A Good Place to Live " PLAN REVIEW Planet Fitness 578 Aviation Road CC-0358-2022 6/10/2022 13,600 sf plus 1600sf The following comments are based on a review of submittals: • Verify fire extinguisher location and inspection • Verify location of exit/ Emergency lighting. Function test will be required • Lock/ latches shall comply with Chapter 10 of 2020 IFC. No key locks • Verify paths of egress • Verify storage • Verify clearances to electrical service panels • CO detection is required, if source is present • Verify Knox Box key(s) are correct • Verify exterior emergency lighting function • NFPA 72 letter of compliance required if any changes or relocation of fire alarm devices • NFPA 13 letter of compliance required for any alterations to the sprinkler system • Contractor to exercise caution and provide protection for all fire alarm and sprinkler devices, during construction as per Chapter 33 of IFC. Contractor shall contact Fire marshal to discuss ri d o ition Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fi r e M a r s h a 1 's Off i c e - P h o n e: 518-761-8206 - F a x: 518-745-4437