CC-0358-2022 Office Use Only
a ADDITION/ALTERATION PERMIT Permit#: GG - OAS " 20 ZZ.
APT�TON
Permit Fee:$ 532�
Town of Queensbury 742 Bay Road,Queensbury,NY 12804 Invoice#:P:518-761-8256 www.gueensbury.net o ca co® Flood Zone? Y viewed By: i�LuO WProject Location: 578 Aviation Road
v = ILL
O
Tax Map ID #: 302.5-1-2.11 Subdivision Name:Aviation Mall
�O
m
PROJECT INFORMATION:
TYPE: ❑ Residential ❑X Commercial, Proposed Use:A-3(EXISTING)
❑ Single-Family ❑ Two-Family ❑ Multi-Family (#of units_) ❑ Townhouse
❑ Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars )
❑ Other(describe ASSEMBLY-FITNESS CENTER )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 1st floor: 15,200 SF(13,600�1�600-9F)
2nd floor: 2nd floor:
3rd floor: 3rd floor:
Basement (habitable space): Basement (habitable space):
Total sq ft: �b6�� Total sq ft:15,200 SF
Scope of work to be done: SCOPE OF WORK INVOLVES INTERIOR RENOVATION OF EXISTING PLANET FITNESS.
-WORK INCLUDES MINOR RECONFIGURATION OF WALLS TO INCREASE ACESSIBILITY.
SCOPE OF WORK ALSO INVOLVES EXPANSION OF TENANT INTO AN EXISTING VACANT
TENANT SPACE(13,600 SF EXISTING PF+ 1,600 SF EXPANSION). _
WORK INCLUDES REPLACEMENT OF LIGHTING FIXTURES TO LED FIXTURES, PAINTING
AND OTHER COSMETIC UPGRADES.
Addition/Alteration Application Revised March 2022
• J
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ 250,000.00
2. Source of Heat (circle one): X❑ Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other:
Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application
3. Are there any structures not shown on the plot plan? ❑ YES IN NO Explain:
4. Are there any easements on the property? ❑ YES ® NO
SITE INFORMATION:
• Is this a corner lot? ® YES ❑ NO
• Will the grade be changed as a result of the construction? ❑ YES ® NO
• What is the water source? X❑ PUBLIC ❑ PRIVATE WELL
• What type of wastewater system is on the parcel? RI SEWER ❑ PRIVATE SEPTIC
DECLARATION:
1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
z
2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description
of the work proposed,that all work will be performed in accordance.with the NYS Building Codes, local building laws
and ordinances, and in conformance with local zoning regulations.
5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: SHAUN N.ANDRIANO(AGENT)
SIGNATURE: �i(,�.�� (,t,,,�.""-�' DATE: 06/02/2022
Addition/Alteration Application Revised March 2022
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): PETER FANTASIA
Mailing Address, C/S/Z: 35 Old Tavern Road, Orange, CT 06477
Cell Phone: 203 ) 745-9050 Land Line: �)
Email: PETER.FANTASIA(oD-ECP-PF.COM
• Primary Owner(s):
Name(s): PYRAMID MANAGEMENT GROUP(JASON TYLER)
Mailing Address, C/S/Z:578 AVIATION ROAD, QUEENSBURY, NY 12804
Cell Phone: ( _) Land Line: 518 ) 793-8818 X 105
Email: JASONTYLERAPYRAMINDMG.COM
❑ Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contact Name(s): TBD-WORKERS COMP PROVIDED AT ONCE CONTRACTOR SELECTED
Contractor Trade:
Mailing Address, C/S/Z:
Cell Phone: Land Line: �)
Email:
"Workers' Comp documentation must be submitted with this application"
• Arch itect(s)/Engineer(s):
Business Name: C2 ARCHITECTURE
Contact Name(s): MICHAEL A. ROMAN
Mailing Address, C/S/Z: 24 AIRPORT ROAD, SCHENECTADY, NY 12302
Cell Phone: 518 ) 320-8250 Land Line: 518 ) 320-8250
Email: ROMAN(aC2-DESIGNGROUP.COM
Contact Person for Compliance in regards to this project:SHAUN ANDRIANO
Cell Phone: 518 ) 320-8250 Land Line: 518 ) 320-8250
Email: AND RIANOAC2-DESIGNGROUP.COM
Addition/Alteration Application Revised March 2022
COMcheck Software Version COMcheckWeb
Envelope Compliance Certificate
Project Information
Energy Code: 2018 IECC
Project Title:
Location: Glens Falls, New York
Climate Zone: 6a
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor: .
578 Aviation Mall Road Planet Fitness GPI
Queensbury, New York 12804 578 Aviation Mall Road
Queensbury, New York 12804
Building Area Floor Area
1-Exercise Center:Nonresidential 15200
Envelope Assemblies
Envelope TBD: No envelope assemblies specified
WE
ENEQ Fo
F3� !6
y Goy R
OWL
B f`o
Project Title: Report date: 06/23/22
Data filename: Page 1 of 8
COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Information
Energy Code: 2018 IECC
Project Title:
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
578 Aviation Mall Road Planet Fitness GPI
Queensbury, New York 12804 578 Aviation Mall Road
Queensbury, New York 12804
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts/ft2 Watts
1-Exercise Center 15200 0.65 9880
Total Allowed Watts = 9880
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp/Wattage Per Lamp/ Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Exercise Center(15200 sq.ft.)
LED:A: LED HIGHBAY: Other: 1 7 150 1050
LED: D: LED MIRROER LIGHT: Other: 1 6 32 192
LED: F: LED DOWN LIGHT:Other: 1 142 14 1988
LED:G: LED DOWN LIGHT: Other: 1 60 14 840
LED: H: LED DOWN LIGHT: Other: 1 8 14 112
LED:SM: LED WALL SCONCE: Other: 1 4 12 48
Total Proposed Watts= 4230
"Interior Lighting PASSES
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Franklin Rapp Elec. Designer gwnfilin&PP 06/23/2022
Name-Title Signature Date
Project Title: Report date: 06/23/22
Data filename: Page 2 of 8
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project Information
Energy Code: 2018 IECC
Project Title:
Project Type: Alteration
Exterior Lighting Zone 0 (Unspecified)
Construction Site: Owner/Agent: Designer/Contractor:
578 Aviation Mall Road Planet Fitness GPI
Queensbury, New York 12804 578 Aviation Mall Road
Queensbury, New York 12804
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts/ Wattage (B X C)
Total Tradable Watts(a) = 0
Total Allowed Watts= 0
Total Allowed Supplemental Watts(b) = 350
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 350 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
Exterior Lighting TBD: Exterior lighting zone not specified (see project screen)
Project Title: Report date: 06/23/22
Data filename: Page 3 of 8
COMcheck Software Version COMcheckWeb
Mechanical Compliance Certificate
Project Information
Energy Code: 2018 IECC
Project Title:
Location: Glens Falls, New York
Climate Zone: 6a
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
578 Aviation Mall Road Planet Fitness GPI
Queensbury, New York 12804 578 Aviation Mall Road
Queensbury, New York 12804
Mechanical Systems List
Quantity5ystem Type & Description
Mechanical Compliance Statement.
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building
plans,specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been
designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name-Title Signature Date
Project Title: Report date: 06/23/22
Data filename: Page 4 of 8
COMcheck Software Version COMcheckWeb
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 :Plans,specifications, and/or ;❑Complies
[PR4)1 calculations provide all information :❑Does Not
;with which compliance can be
:determined for the interior lighting :❑Not Observable
:and electrical systems and equipment ❑Not Applicable
and document where exceptions to
:the standard are claimed. Information
provided should include interior
;lighting power calculations,wattage of
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3)
Project Title: Report date: 06/23/22
Data filename: Page 5 of 8
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID
C405.2.2. ;Spaces required to have light- ;❑Complies
2 reduction controls have a manual ;❑Does Not
[EL22]1 ;control that allows the occupant to
reduce the connected lighting load in ![:]Not Observable
a reasonably uniform illumination ;❑Not Applicable ;
pattern >= 50 percent.
C405.2.1, ;Occupancy sensors installed in ;.[:]Complies
C405.2.1. classrooms/lecture/training rooms, :❑Does Not
1 ;conference/meeting/multipurpose
[EL1811 I rooms,copy/print rooms, ;❑Not Observable:
lounges/breakrooms,enclosed offices, ;❑Not Applicable ;
;open plan office areas, restrooms,
storage rooms, locker rooms,
warehouse storage areas, and other
;spaces<= 300 sgft that are enclosed
by floor-to-ceiling height partitions.
Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
;for open plan office spaces.
C405.2.1. ;Occupancy sensors control function in ;❑Complies
2 warehouses: In warehouses,the :❑Does Not
[EL19]1 ;lighting in aisleways and open areas is
;controlled with occupant sensors that ;❑Not Observable
,automatically reduce lighting power j❑Not Applicable
by 50%or more when the areas are
;unoccupied.The occupant sensors
control lighting in each aisleway
independently and do not control
lighting beyond the aisleway being
!controlled by the sensor.
C405.2.1. !Occupant sensor control function in ;❑Complies
3 open plan office areas: Occupant ;❑Does Not
[EL20]1 ;sensor controls in open office spaces ;❑Not Observable',
>= 300 sq.ft. have controls 1)
configured so that general lighting can j❑Not Applicable
be controlled separately in control
;zones with floor areas <= 600 sq.ft.
within the space,2)automatically turn
off general lighting in all control zones ;
;within 20 minutes after all occupants ;
have left the space, 3)are configured
so that general lighting power in each ;
;control zone is reduced by>= 80%of ;
;the full zone general lighting power
;within 20 minutes of all occupants
leaving that control zone, and 4)are
;configured such that any daylight
;responsive control will activate space ;
general lighting or control zone
;general lighting only when occupancy j
'for the same area is detected.
C405.2.2, ;Each area not served by occupancy ;❑Complies
C405.2.2. ')sensors(per C405.2.1) have time- ;❑Does Not
1, ;switch controls and functions detailed
C405.2.2. in sections C405.2.2.1 and C405.2.2.2.;❑Not Observable
2 ;❑Not Applicable
[EL21]z
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Report date: 06/23/22
Data filename: Page 6 of 8
i
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
&Req.ID
C405.2.3, ;Daylight zones provided with ;❑Complies
C405.2.3. individual controls that control the ;❑Does Not
1, lights independent of general area
C405.2.3. {lighting.See code section C405.2.3 �❑Not Observable
2 i Daylight-responsive controls for ;❑Not Applicable ;
[EL23]2 ;applicable spaces,C405.2.3.1 Daylight;
'!responsive control function and
section C405.2.3.2 Sidelit zone.
C405.2.4 ;Separate lighting control devices for ;❑Complies
[EL26]1 :specific uses installed per approved :❑Does Not
lighting plans.
:[]Not Observable;
❑Not Applicable
C405.2.4, ;Additional interior lighting power ;❑Complies
[EL27]1 ;allowed for special functions per the :❑Does Not
;approved lighting plans and is
;automatically controlled and ❑Not Observable;
separated from general lighting. ;❑Not Applicable ;
C405.3 I Exit signs do not exceed 5 watts per ;❑Complies
[EL6]1 face. :❑Does Not
![--]Not Observable
;❑Not Applicable
C405.6 Low-voltage dry-type distribution ;❑Complies
[EL26]2 lelectric transformers meet the :❑Does Not
minimum efficiency requirements of
;Table C405.6. ;❑Not Observable
;❑Not Applicable
C405.7 !Electric motors meet the minimum ;❑Complies
[EL27]2 efficiency requirements of Tables :❑Does Not
j C405.7(1)through C405.7(4).
{Efficiency verified through certification;❑Not Observable
lunder an approved certification ;❑Not Applicable ;
j program or the equipment efficiency
ratings shall be provided by motor
manufacturer(where certification
programs do not exist).
C405.8.2, Escalators and moving walks comply ;❑Complies
C405.8.2. !with ASME A17.1/CSA B44 and have :❑Does Not
1 automatic controls configured to
[EL28]2 ;reduce speed to the minimum :❑Not Observable
I permitted speed in accordance with ;❑Not Applicable
ASME A17.1/CSA B44 or applicable
local code when not conveying
;passengers.
C405.9 ;Total voltage drop across the ;❑Complies ;
[EL29]2 combination of feeders and branch :❑Does Not
circuits<= 5%. ;❑Not Observable;
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Report date: 06/23/22
Data filename: Page 7 of 8
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID
C303.3, Furnished 0&M instructions for ;❑Complies
C408.2.5. systems and equipment to the ;❑Does Not
2 building owner or designated
[FI17]3 representative. :❑Not Observable
❑Not Applicable ;
;
C405.4.1 ;Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values.
[FI18]1 lighting power is consistent with what ;❑Does Not
is shown on the approved lighting
:plans,demonstrating proposed watts ❑Not Observable
are less than or equal to allowed ;❑Not Applicable ;
;watts. ,
C408.1.1 ;Building operations and maintenance ;[]Complies ;
[FI57]1 1 documents will be provided to the ;❑Does Not
;owner. Documents will cover
;manufacturers'information, :❑Not Observable
:specifications,programming ;❑Not Applicable ;
procedures and means of illustrating
Ito owner how building,equipment and
systems are intended to be installed,
maintained,and operated.
C408.2.5. 1 Furnished as-built drawings for ;❑Complies
1 electric power systems within 90 days ;❑Does Not
[,FI16]3 of system acceptance.
❑Not Observable
;❑Not Applicable
C408.3 !Lighting systems have been tested to ;❑Complies
[FI33]1 ;ensure proper calibration,adjustment, T❑Does Not
programming, and operation.
;❑Not Observable;
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3)
Project Title: Report date: 06/23/22
Data filename: Page 8 of 8
FIRE MARSHAL'S OFFICE
TOU)n of Queensbunj
742 Bay Road, Queensbunj, NY 12804
"Hone of Natural Beauty ... A Good Place to Live "
PLAN REVIEW
Planet Fitness
578 Aviation Road
CC-0358-2022
6/10/2022
13,600 sf plus 1600sf
The following comments are based on a review of submittals:
• Verify fire extinguisher location and inspection
• Verify location of exit/ Emergency lighting. Function test will be required
• Lock/ latches shall comply with Chapter 10 of 2020 IFC. No key locks
• Verify paths of egress
• Verify storage
• Verify clearances to electrical service panels
• CO detection is required, if source is present
• Verify Knox Box key(s) are correct
• Verify exterior emergency lighting function
• NFPA 72 letter of compliance required if any changes or relocation of fire
alarm devices
• NFPA 13 letter of compliance required for any alterations to the sprinkler
system
• Contractor to exercise caution and provide protection for all fire alarm and
sprinkler devices, during construction as per Chapter 33 of IFC. Contractor
shall contact Fire marshal to discuss ri d o ition
Michael J Palmer
Fire Marshal
742 Bay Road
Queensbury NY 12804
firemarshal@queensbury.net
Fi r e M a r s h a 1 's Off i c e - P h o n e: 518-761-8206 - F a x: 518-745-4437