Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2000-620
TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (519) 7614256 C JLV 'L ICATE F OCCUPANCY Permit Number. P20000620 Date Issued. Thursday, December 07, 2000 This is to certify that work requested to be done as shown by Permit Number P20000620 has been completed. Tax Map Number, 523400-i48-OOO-O003-079-OOOm0000 Location, HUDSON POINTE Blvd Lot 79 , House No . 196 Hudson Pointe Blvd . Owner. HUDSON POINTE, INC. Thus structure may be occupied as a: Fireplace Garage - 2 Cars Attached By thderof Town Board Single Family Dwelling TOWN OF QUEENSBURY Director o Building & Code nforc ent TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 (518) 7614201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20000620 Application Number: A20000620 Tax Map No: 523400-148-000-0003-079-000-0000 Permission is hereby granted to: MICHAELS GROUP Owner of property located at: HUDSON POINTE Blvd in the Town of Qupensbury, to construct or place a Single Family Dwelling at the above location in accordance with application together with plot plans and other information 'hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Owner Address: HUDSON POINTE, INC. 300 ERIE BLVD. W. SYRACUSE, NY 13202 Contractor or Builder's Name / Address Electrical Inspection Agency MICHAELS GROUP NEW PORK .BOARD OF FIRE UNDER 10 BLACKSMITH Dr STE 1 MALTA, NY 12020 Type of Construction: Single Family Dwelling. 'Value : S 161,900*00 Plans & Specifications 2000-620 2321 SO FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS *. $298000 PERMIT FEE PAID - THIS PERMIT EXPIRES: Wednesday, September 18, 2002 (If a longer period is required, an application for an extension must be made to the code Enforcement (Amcer of the Town or Queensbury before the expiration date.) Dated at the Town of Queensbury; Monday, September 18, 2000 SIGNED BY for the Town of Queensbury. Dire for of Building od forcement Buzzaing Permit Application TOw11 O,f Quee 8'Sbury - Dc w of Courrt►urilty Dcvrinpr►rrttt, 742 I3a Rorrrl, [NICE'''' U I L IJ 11V G dr . C O D E ,E IV F O R C E 1N E Qrrr ruxllur;v, NY /2804 /761 32SG/ Requirements prior to issuance A permit must be obtained before of this permit: PEItrY1l7 FIGC TIO,�t �u beginning construction. No inspections will ba made anti! applicant has rexeived ZOn6tg Board Actlart Pi RMf r FCC PA ID $ a VAI.I17 T3UTLL7INC3 PBRhtIT. All Arras / Use applicants' $Pace$ an this application RECRLOAT1ON PEE- I' U S MUJST be t ampleted at5d• tha signature of the applicant- must appear on the © PIMIning Board Action R , VICWLE) BY.• n plicabon form, r� SPR f Subdivision / other Dr�rG1Fn, fr r _ r Recra�stion Fee Payment Applicant: �L LS Owner: 4�- VIA& " Address: _ - - Address: Phone ## Z` _) Phone # Property Locution : Subdivision N.tntc: Map Nut I cr —� Section 111ock t nt NATURE OF PROPO5Eb WORK : _ New Building : ESTIMATED M�:lRl{ET VAL residence / commercial CONSTRUCTION : $ -- Ita2k Addition to Building : residence / commercial OCCUPANCY INFORMATION Alteration to Building = Primary Building - reaidence / commercial _ Single Fami1 Dwelling Residence / Commercial Two Family Dwellin no change to exterior size Family Dwe3ng5 ,.- , ~ Other Work ( describe below Office } Mercantile AUG 1 B 2D0'� Manufacturing Other GROSS AREA. OF .PROPOSED STRUCTURE : 1st Floor . . . . . . . • _ � sq * fta if ADDITION , what: will use 2nd -Floor , . . 1004 , iZ4Lo sq . ft , of new, addition be ? : Other Floors . . . . . sq . ft . - 'n" ( not unfinished cellar or basement ) AccEssaRx suxx,DrrrGs . 7 Detached Garage 11 2 c TOTAL FLOOR AREA : ." � SQ . FT . �� Attached Garage 1 2 car SIZE OF NEW STRUCTURE : Private Storage Buil I Commercial Storage Building FEET X FEET Other Foundation Type : ii , Will any second - hand or ungraded Number of Stories : �2. �' Lumber be used ? if so , for what ? ( habitable space only ) Height ( grade to ridge ) , /� ] feet TYPE OF HEATING SYSTEM : Number of fireplaces and/ or woo stove ( circle all which .,, �aplies ) to be installed : _� Electric / Oil / as / Woad Forced Hot Air / Baseboard / Other Person r taponsible for s'upery on of work as regards to building . codes i s : r, k l,..co V>� Na'- e A dre s Phone Builder : Plumber : O l � VNj '2 Mason * I Tk I j III �t"X 'r_��.1 �•�l$C=1 ( �-_ Electrician • r--- 2� DEC'I-4 A770 ,# Please sign beltnv after' you have carefully read the statement. To the best of my knowledge the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be clone on the described premises and that all provisions of the Building Code, the Zoning. Ordinance and all other laws pertaining to the proposed work shall be complied with , whether specified or noted , and that such work is authorized by the owner. Further, it is understood that I/we shall submit Prior to a Certificate of Occupancy'or Certificate of Compliance facing issues] , an AS BUJILT PLOT PLAN by a licensed suaveypI drawn to scale, showing actual loca 'on of project on premises. Signature: VIII r) I (owner, owner's agent, architect, contras or) Application for Permit — Septic Disposal System T Mvrs 01 Q1rYa1,;.vbi";y 742 13ay 1{lJtrli Jrrt errslrIIry, IJ1 I71y0 f (518) ?G I- Y� sG 1 . OWNER INFORMATION: �........... ........... ..... ... ..._.. ............. Location of installation: 01,11ce Use j � i F� 52t4S�r"` . Tax Map No. / / File Permit No, j Owner's Name: 'T"E �� ti ( Fee Paid Address e 2, INSTALLER'S NAME �1+ ] �,�ls PHONE NO, 3 . RESIDENCE INFORMATION: {circle year of dwelling, in dlca(e # bedrraorrirsJ and nlultilaly 11 nJ bedrooms with applicable gallons per bedroom to equal total dailvflu;v) Year of House: of Bedroo is x om utatioxl Tvtal Dail Flow 1980 or older x 150 gallbdrm = 1980 — 1991 x 130 };a [/bdrna = 199 ! — present ! x [ ! 0 ballbdritl Garbage Grinder Installed yes I no Spa or Whirlpool Installed yes 1 no 4 , PARCEL INFORMATION: (circle applicable information & indicate measurements) TQ o 'ra 11 SQil ?Vattira rouaad Water ,[3ecfrQck r impervious Material Domestic Water Stoppj l�lal scrrrd Mallirrg tree at sl�v (v^al d plh al what depth rrngm.c'i al, ! Sleep s top C' Clay � � �GGrf �Crl{f � �_• �'r .slope other if +vcrll; Iveller supply dept&* fi•onr al: v seplic-sy.sleni CfIJ.Soey)ir(.7rr is Jr, Percolation Test: {�1 fJ IJG Cll rrrlalC tGCI 1)y lJ l:C r7,SLd lar'IJJe,1',5'ifJrrLr! GrTiE;ir'feCr rJJ' aYr.'Jrlll.'C'r� Rate: � � ��„ nrirrrrlc perr Nrc'!r 5 , PROPOSED SYSTEM: For New Cunstructi n: All individual sewage disposal systems must be designed by a licensed professional etsgitlecr or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to late sire Of (he septic tank and leach licid for each Garbage Grinder, Spa or Whirlpool Tub, Septic Tank; 1 COO gallon ('ruin, size 1, 000 gal.) Tile Field; each trerrela 7/ Jl. Total System Length : 2: 1 Seepage Pit(s): number of..size of'eacla: Size of Stone to be used: 11 / cleplh or Bed System Size: x Altertlativo System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: ( •j" I Size of each : gallons I TOTAL Capacity: gallons N,we: Alarm System and associated electrical work must be inspected by a Town Ipproved electrical inspection agency, T SIGNATURE & INFORMATION FOR RESPONSIBLE PERSON (please read) For your protection, please note that pursuant to Section 136-29 oftlie Code of die Town of Queensbury, any permit or approval ,granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or oil behalf ofan applicalrt, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance 4Sigture of responsible person pate }:ir't ,l }:it'tilr:tl Office A*Ct trt cif QUee13tilrr r.N 742 B aY R(.Po 1 , Quecct,,I)cir-ti , is S i1i1 :r i -820 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances i C3.1cc — , 20 #rl4- Permit No. + =fpplicatiur7 i.ti he eby antic !re the 131ri1t1ir7g & C'rx<1G•; !)1l"ir c jrxr the i 1.srrcrrrc't uJ a the ldi,t(; rear! (:'.VCP l'e1arrit pw-Siealrt to the Now )'nrlc Srwe fire Preverltirm a1rr113rrilrlill,� C."c�rlr- 77ic 4;1a1'(ic'ur1t oo1 ot�vlcr 1 L'Igives to c.'orrrply as itlr all u1plic'ahle lrawS, nrrlirlarrc e'5 1-%L,7111(11101IS. t11!tl rill c oIIdiItoIis• that el<' l)ctr'! r?f i t these rleyttireeuerrts crlirl also twill allow cal irrstlr cYcar .s to catrr 1 r rrri.tic ., cry per/error, r c rlrtia cc1 iar.ti(7ce.virarls. f I ll CTE to applicant : Rough - in and Final hispectioris are requ _ tred . k l � Applicant Information Pa., ef 13urniiig ,4japiiattce Ctfforrt', aEio « ( ckicle appropriate \vords) \ante: ' M' lm ��` Sfc>t e 1t r>r t� coif! tJc>lfet }as i ^4 £�il�Cpl�lcc: it�scrt I Address ; _ Firepi .ace, factory-built : I oor tares — - � Firepiaec, 111asonry: 1-1100 gets' y Fua nace ' 1t acrd 2� }7^s oil f i Phone : lfnon -tnasonary applicance, please provide Owner: Narne: ' Address: Model Number: Chimnev Infoi-rniation Phone: � fcll-c ',e rf)propriate curds) Masonry ltlock bt-ick stone ePTIl the errjV7*'\ sire: ittclres C Exact Address: � 9 .Y4 � - ' nfcorrsrr•rrrf!oil or irrsrrr lrrti i1CLOr -Blkilt Manufacturer name: Model NUrriber: ;'rote: Listed Bv: Number! construetiola 1171stallation nttast f eon Qrm to NYS Fire Prerentiotr & Builaing Indicate (circle) chininey material : ' Code. Coiisirlt ovailable Town of Queensbza-v HaliClows regarding regWr'ed inspections. Doieb!e ir(ill .` Triple „ all / Irrsidevecl i Direct velitln Chinrrrea' Liner Gs+�a.if�.af�.x.�'rB .�►r��a.tx.=•t-"="= �x'aR t -- 'T"'Ci�r'_7a. v.P Q tx��n �b u-='.ma's .i,►T�]r�r `JE''ior.�r � � I Fire ,ltal-s rtrl Code n C011etered Rc=lirnrlod RvCvivL'tl %r-1-YM 0t'j1rrlrlCrl lr)): 4 1 73 .3389 (1 J()) Public Snfcra - - .4 233 2 65 S (230) 11llrr01 Srrle,l —`_ __._--_----- .JI White (Appiicaw) 1'Cij(11k4' { I3i(l4q. Dg3t. I pink GSA GaSjCfl[ )-od ICashicr's Dtcpd . ) s i 1 TOWN OF QURENSBURY BUILDING & CODE ENFORCEMENT 742 BAY ROAD QUEENSSORY NY 12804 (518) 761-8256 -- - ARRIVE : DEPART : rINAL INSPECTION REPORT — RESIDENTIAL DATE INSPECTION REQU �QC VED : NAME MICA LOCATION �L: f` X> C VA0 / DATE �Z- � P E MZ T # TYPE OF S'T'RU0 URE FOOTINGS FOUND ION BACKPI FRAMING ROUGH PLUMBING SEPTIC INSrLATION FINAL ELECTRICAL WOODSTOVLn ORIFtEPIs.RCE R YES I NO CHIMNEY F[EtGHT/B VdHT/HEIGHT PLUMBING VENT —S ROOFING X ERI R FINISH1 DECKZPORCH /STEPS/RAII,�' ,.NGS RELIEF VALVES td CE HO TI INTERIOR TRIMZPRIVACY S FINISH Y FLOORS ; BATH/KITCHEN WATE TI OTHER FLOORS 'SW P B E _ OTRER F,j.AORS CARPET ID 1{ STAIR CLEARANCE /RAIIINOS _. SMOKE D TEC O S BATHROOM FANS PLUMRNG FIXTURE FOUNDATION INSU ATION G PING DOOR CLOSERS f L CT CAL E P V RIANCE REQ FINAL SURVjY PLOT PLAN _ N 'y OK TO $ {9 C O OR Qlc NAP REFERENCE: HUDSON POINTE P.U.D. PHASE U BY VAN DUSEN & STEVES DATED MAY 1994 LAST REVISED MARCH 7, 1996 FILED IN THE IYARREN COUNTY CLERK'S OFFICE ON APRIL 16, IS AS INSTRUMENT NO. 44 PLAT CABINET B SLIDE 64 HUDSON p01NVrA " N.aia s Q ez •UNAUTHOW ED ALTERATION OR ADDITION TO A SURVEY MAP ILF.ANNO A LICENSED LAND SURVEY= SEAL 13 A Map of a Survey made for A VIOLATION OF SECTION 7109, SO -DIVISION$ OF THE NLV YORK STATE EDUCATION LAW `�.\�/ / t e v e S 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARS X& % NTH AN MoEREOINAL OF THE LAND SLRVEYORS sEu SHAu SE wNSIDERED TO IN: VALID TRUE CONEA' WT,M'" WAS PREPARED � SgNICE TIiAT THIS SURVEY WAS PREPARED w ACCORDANCE TURN THE David W. & Ellen P. Eberle FxIrnNO CODE OF PRACTICE MR LAND SURVEYORS AOOP7Eb Land Surveyors, LL C BY D S NEWRVE ORS !RATE A9BOpMION OF LL RUN ONAL LAND SURVEYORS SAID CER1iIP.AIIONs SHALL RUN ONLY TO THE PERSON FOR YNOM TTE SURVEY IS PREPARED. AND ON HIS BEHALF TO THE TITLE COMPANY. ODM0004TAL AGENCY AND LENDING NrnTUITION LISTED HEREON, AND Town of Queenebury, Warren County, New York 169 Haviland Road Queenab ury, New York 12804 TO THE ASSNEES OF THE UMM NSMIUUOI.• '518) 792-8474 New York Lic. No. 50135 I HEREBY CERTIFY THAT THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS O V ED FOR OM THE SURVEY WAS AND ON THEIR RC BEHALF TO THE TITLE COMPANY, GOVERNMENTAL GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. DFc 0 7 2000 71IFIC TO ADDITIONAL ARE NOT TRANSFERAENT ICE 0NONS SLE OF QUEENSBURY TOWN F+�C CODE CERTIFIED TO: David W. do Ellen P. Eberle BUI gns Fleet Mortgage Corp., I'ts Successors and/or Assigns Chicago Title Insurance Company NO. I DATE CERTIFIED BY. MATTHEW C. STEVES, LLS NYS 50135 DATED: November 29, 2000 DESCRIPTION Scale 1"=30' S-1 %M1OPI Eberle DWG. NO. Hp-79 RESEDRNTIAL FIRM INSPECT>lUN gRppRT Date inapecstion request received: � Clfl`ice No. (518} 76i-825d - Building & Code Rnforeement art Dept. of Community Development Arrive am/pm Depart Irrspertor's Initials Town of Queensbury 742 Bay Road Queensbury, New York 12804 If y. rJvP NAME ATE [ LOCATION CATION TYPE of ST—TR I X t E. `NIA YES NO CQTvQrSEN`i'S Chimney Helghtr'W Vent/1%rect Vent Location Fresh Airintake Plumb Vent through roof Roof CComplete Exterior Finish Complete lnteri 30» to 36" } � /l c+rlEssterioar Railings l8 • or more ✓ �T ! Exterior handrails, balconies, landing Interior I- ails stairs both'*des 3 or in risers Crrade 2°/u away from foundati t $" clearance to sill plate 1$„ alwve grade G as Valve shut-off exposedlregula Gas Furnace shut-off within 30 withist line of site oil furnace shut-off at entrance t area Fur aceMot Water' beater o Relief Valve(s) installed lleadtrooml, 6 ft. 6 in. on Is ' 413a t stairs, 6 ft. 4 in. hi Handrail exterior' stair's sides more than 3 Interior privacy/trrm/d main entrance 36" Floor Finish Dathroonvywehen wa Interior handrails enn Inc ins 1& in. or mare Railing across wind in stairwells _ — Smoke DetectOM every level every outside ev inter conrr ed Bathroom fan Plumbing fi Foundation sulation 3/4 hour fire oor/door c1o5eG- -Garage �t m Garage penatra seated Furnace in separate room protected (mi garage) Light ventilation per rocntr Safety glazing I v or less from Hor F' al Electrical Ire P1anlVariance required Final Survey Plot Plan As Built Septic System layout regnired -- Okay to issue C/C (Certi r of Compliance) okay to issue temp. C/o (Certif. of occupancy)-- okay to issue permanent c/o (Certif. of occ upaucy) RESIDENTIAL FINAL INSPECTION REPORT � � ' (Do ► � Office Nu Date nspxtion TeMICstrreceived:$uiiding & Code Enforcement Dept. of Community Development A amfpm at pm Town of Queeusbury lc F� lax gay Road ..�,`" QQueensbury, New York 12804 NAME PERMIT �/ � G �- I OGATiOI�I ` .DATE TXPIE OF S'jRUCTrjjR> N/A S / NO COMMENTS x Chimney Hei$lit/ B" VaVA3irect Vent Location Fresh Air Intake Plumb Vent through roo Roof Complete Exterior Finish Complete: litt('r7oVE)rterr.or Railings IN W, to 36" Exterior Handrails, balconies, landing IS in. or more Interior Handrails stairs both 'des 3 or more risers Grade 2% away fbwu fornrdati 8" clearance to sill plate Gas Valve shut-off exposed/regulat 18" above Gas Furnace shut-oft'within 30 feet or i in 1' f site Oil Furnace shut-off at entrance to farna Furnace.'I-lot Water Beater opera Relief Valve(s) installed Headroom, 6 ft. 6 in. on stairs Basement stairs, 6 ft. 4 in. Handrail exterior stairs both sides more 3 risers � !� lei C Cf> = AH1E 1'`r A a-K 'hock-ik'5 Interior privacy/tr ffnfdoorshna n entran 6" Floor Finish BathroonvRitchen watertight Interior Handrails Balc0niC9 1ndin -- �, in, or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire door/door closer- Garage freproofiin t /1 Garage penetrations sealed I� ,�L Furnace in �7arale room Prot ted (in garage) Light ventilation per qom Safety glazing l $" QpQr Final Electrical Z/ Site Plan/Variance i Final Survey drat Ilan. ,.✓ s tl' �—As Built Septic System layout required Okay to issue C/C (Certif. of Compliance) Okay to issue temp. CIO (Certif. of Occupancy) Okay to issue permanent CIO (Certif, of Ocx rrpancy) J:�� A jlra � FIRE MARSHAL TOWN OF QUEENSBURY QUEENSBURY> NY 12804 (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED PERMIT #, -, NAME LOCATION SCHEDULE INS C N ON 1�?vn • I� "�`�'� 'o ,Z� AM M ANYTIME APPROVED ^ lee � NIA ' YES NO EXITS (((fff I — AiSLE WIDTH EXIT SIGNS EMERGENCY HTING _ FIRE EXTINGUIS RS FIRE ALARM SYST FIRE SPRINKLER SY M FIRE SUPPRESSION S TEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: -- CLEARANC To SPRIN RS _ CLEARAN TO HEATING ITS REOU€RED SIGNA _ CHIMNEY WOOD STOVE F PLACE - MA NRY ^ P€ACE - FACIPRY BUILT REMARKS: 0 OK TO IS DATE x, 't i m3PSLOP.PUB � INSPECTOR THE NEW YORK BOARD OF FIRE UNDERWRI S 4? 1 ,. 8 tP'•`:* BUREAU OF ELECTRICITY 40 FULTON STREET, NEW XQR L7ote 611';# 'E+;11Fi1;3i !> r , ?i1!)t] Application_Nor'da" E3Eil' 114 file f'7 `.* : {r iS#J I ?i1 F # ' r Li >iI THIS CERTIFIES THAT F' v NO . 2# iiJ0 4I 3s ' O only the electrical equipment as described below and introdtLe th�gyswwetF on$the above application number is in the premises of `€`! ii'; to-'(Pik . I %f(, 1400810N L'ij114TE< EIl ,Vl + , {i!lE1E;LV 's15'•. It,< 4' _ Ni in the following location; El Basement El lst Fl. E:1 2nd FL U'Ail Section dock Lot a •, was examined on l D I ;i:i l l#31 ;L; #. ; :'i ii i[ 3 and found to be in compliance with the National Elecn-tcal Code, , FDCTURE RECEPTACLES SWITCt1ES FIXTURESqFEEDEIRtS RANGES COKYKIPIG DECKS OVENS DISH WASHERS EXHAUST FANS OUTLETS M. K.W. AMr. K.W. AMT. K.W. AMT. X.W. DRYERS FURNACE MOTORS FUTURE APPLIASPECIAL REC'FI. TIME CLACKS BELL UNITHEATERS MLUUFT DIMMERS Alan. K.W. OIL X.P, eA3 N.P. Ma, NOAMT. AMP_ AM - ARIP3. TRAN . AMr. N.P. NO. OF FEET . WATTS I SERVICE DISCONNECT I=-T60rr-j S E R V I c E /1MT. hMr_ TYPE EaulP. 1 i RW T e 3W 3 • 3W 3 0 4W NO. OF cC:: D_ A. W. c. NO. OF NI-ucv A. W. G. Np, OF NEUTlCALS A. W. C. PER a OF cc. ccmv, OF NI-LE& OF NEVIRAI OTHER APPARATUS: C= . E` . C` . -G S 1.1fH1'I'F7C`LYiR . r i t;u I•,'u �; l,E�� � ! t3! �Exl � F;i ,e��' . ` �dw..r�..�. � +.-c. GENERAL MANAGER i Per This Cortlflcate trust not bo altered In any manner, return to the office of the Board it Incorrect. InspectOFS may be Identified by their credentials. COPY FOR BUILDING DEPARTMENT, THIS COPY OF CERTIFICATE MUST NOT BE ALTERED IN ANY MANNER. err.. F►RE MARSH,q� QOF U ENSBURY EMISBLIRY (518) 761-205 ?2804 FIRE MARSHAL INSPECTION REQUEST RECEIVED REPORT NAME i NTO c CFIDURMIr # INSPEcDON ON -- - __ A p EXITS _ APPROVED AISLE WIDTHS NIA YES ND EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE. _ CL6ARANC O SPRINKLERS ct REQUIRED SIG E TO HEATING UNITS AGE YCHIMNEY ,WOOD STO Wr FIREPLACE MASON Y _ `--- OUGH-IN io FAC-roRY BL,. C1 FINAL REMARKS: OK TO THIS DA TE INSPECTOR GAN ERAL INSPECTIC7IV REPORT ( 518 ) 7 +61 - 8256 Town of Queensbury Dept. of Community Development hate inspection request received: Building & Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive am/pm Depart Inspector's Initials NAME: L PERMIT # � LOCATION- k)2 f T DATE TYPE OF STRUCTURE: RECHECK NIA YES NO COMMENTS Faotings/Piers �. Monolithic Pour Form Reinforcement in Place The contractor is usible for providing protection rn freezing; for 48 hours foliowin the placem nt or the concrete. Materials for this purpo on si Foundation/WalIpo Reinforcement in Foundation/Dampproof - Backfxll Approval Plumbing Linder Slab Plumbing Vent/Vents in lace Rough Plumbing Hea ' Rough I ation Foundation Walls In 'or R- Foundation Walls Ext 'or R- Floors R- Walls R.- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studsffleaders BracingMrldgin Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppin GENERAL INSPECTION REPORT ( 518 ) 761 - 8256 Town of Queensbury ,f Dept. of Community Development .Date inspection request received: fro Building &z Cade Enforcement / 742 Bay Road Queensbury, NY 12804 Arrive am/pm Depart Inspector's Initials ] IL NAME: `- �� PERMIT 4 _ � �lv LOCATION• _ -- DATE : Z � TYPE OF STRUCTURE: RECHECK NIA 'YES NO CON04ENTS Footings/Piers Monolithic Pour U7respo Reinforcement in The contractorble forproviding protfreeing for 48 hours fo placexneof the conMaterials for site FoundationfWall Reinforcement in PlacrJ FoundationlDampproo Back ill Approval Plumbing Cinder Slab Plum ent/Vents Place Rnitiwh Plumrlin --�-7` A ��. c] u 1 iJl7 I. Fr � 7 --�1 ✓ 1 L"f C�' {c' uJab oundation Walls terior R- Foundation Walls xterior R- -- - — Floors R- Wall,s R- Ceiling R- Duet work or piping in T' -4 . ;' �CE -4 +- CC �f f< unheated spades R- Proper Vent, Attic Vent Framin Jack StudsMeaders BracinwBridgi Joist I-laugers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Perietration Sealed Fire Wall 2, 3, 4 hour Firestopping 'TOXIN OF QUEEN§BURY U BUILDING &_ CODE ENFORCEMENT 742 Bay (load Queen_ sbury NY 22804 (5t8) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION (dame Location Date / k: %?U G)N�) PenMi t # �`U `f ' .Z- ' SOIL TYPE: �SanC Loam Cl ay- Resul is of Fier l ati n Test- ( if applicable ) ate- inute,/Inch TYPE OF SYSTEM: ABSORPTION FIELD : Tot 1 Len the 2-2-0 Length of each tre h + { Depth of trenches Size of stone SEEPAGE PITS : Number Size - ft . x ft . Stone size PIPING : Size Type Bldg . to Tank ?c 6 Wank to Dist . Box + > Dist . Box to Field/ c+ ak Openings Sealed ? es No Partial LOCATION/SEPARATION Foundation to Tank ) feet Foundation to Abso tion feet Separation of Pits Feet Conforms as per PI t fl an � Yes o LOCATION F SYSTEM ON PROPERT ( ci rcl a ne Front Rear - Le Side - {Right) icfe Middle - M ' ddl a Rear COMMENTS : i SYSTEM USE APPROVED : YE NO Arrived : Depp a rted : G_C. Building Inspector DSON POMTE �`�, .+�.r it�l �. Ells..► t,-'. '�-b��a . GREEN SPACE a G F©�© AL L" •r` cc 1} r sII M .z � 2— lean or . or believ evedence of. '�;or4s S',1C� s, trees, fences, etc., ems document l also represent that 1 have measured the distances set forth on the diagram. i L' V 1�.� SIGNATURE 4DA •' �•. s—s TOWN OF QUEENSBURY BUILDING d,_-_CODE ENFORCEMENT 742 Say Road Queensbury IVY_ L284D4 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name Location Date {} Permit , Zo SOIL TYPE: S nd- Loam- CT ay. Results of Percolation Test- ( if applicable } Rate-Minute/Inch TYPE OF SYSTEM: ABSORPTION FIELD: Total Length Length of each trench Depth of trenches Size of stone SEEPAGE PITS: Number �- ---� Size - � Stone size� fto x ft . PIPING : Bldg . to Tank S � z ype Tank to Dist . Sox Dist . Box to Field/P ~�~ Openings Sealed? Ye a art al LOCATTON/SEPARATIONs : Foundation to Tank Foundation to Absorpti n feet Separation of Pits feet Conforms as per Plot Ian feet LOCATION OF SYSTEM ON PROPERTY: s No (circle one) Front - Rear - Left ide Middle Front - Middl Rear Right Side COMMENTS : : SYSTEM USE APPROVED: YES NO Arrived Departed: �Bui ding nspect G`ENER9.L INSPECTION REPORT ( 518 ) 761 - 8256 Town of Queensbory Dept, of Community Development Date inspection request received: .Building & Code Enforcement 742 Bay Road y Queensbury. NY I2804 Arrive amfpnx Depart ) ' in Inspector' als s initi NAME: � G l �S _ PERMIT # 02> W I,CjCATI©N: tp DATE : 2 7 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS FootingvViers Monolithic Four Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placetne t of the concrete. Materials for this purpose on Site Fou ndation/Wallpour Reinforcement in Place Foundation/Dampproofin Backfill Approval Plumbing Under Slab Plumbing VentJ�+'ents in Place Rough Plumbin Heating Rough-ln Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- �oppe�r pent, Attic Vent /3a - SUWs/Head rs Bracfni;Mridging Joist Hangers lack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppin 1 GENERAL INSPECTION REFL7RT ( 518 ) 761 - 8256 Town of Queensbury Dept, of Community Development Date inspection request received: .Building & Cade Enforcement 742 .Bay Road Queensbury, NY 12804 Arrive am/ } _ � pm Depart pM Inspector's Initia J '� G 'r ls r-0 l / P PERMIT # Z© LOCA9 ON: � i'". �7ry,",. �1 V C( , DATE STRUC —4 F qFFES N/A YES NO COMMENTS Footings/Piers _ Monolithic Four Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the t of the concrete. Materials for this purpose on 'te Foundation/Wallpvur Reinforcement in Place Fvuttdativn/Dampproafin Bacldiil Approval PI mbtng Linder Slab umkring Vcnt/Vents in j Rough Pllumbin Heating Rough-In Insulation Foundation Walls Interi R- Foundation Walls Exteri r R- Floors _v Walls _ Ceiling Duct work or piping in Unheated spaces Proper Vent, Attic Vent �CFrami Jack Studs/Headers Bracing/Bridging, Joist I1sxngers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour )C'Firestopping f r FIRE MARSHAL TOWN OF QUEENSBURY QUEENSBURY, NY 12804 (518) 761-8205 f� FIRE MARSHAL INSPECTION REPORT + REQUEST E EIVED NAME LOCATION PE IT • ` SCHEDULE INSPECTION ON z ' --�- M PM�^ APPROVED I EXITS NIA YES NO t AISLE WIDTHS EXIT SIGNS f EMERGENCY LIGHTING i FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM.o I FIRE SUPPRESSION SYSTEM I MOOD INSTALLATION t INTERIOR FINISHES STORAGE CLEARANCE TO SPRINKL CLEARANCE TO HEATING -[ jIVS REQUIRED SIGNAGE ITS C NEY OOD STO FIREPLA [] MASONRY FACTORY $Lr, f ROUGH-IN EJ FINAL REMARKS: r CI OK TO THIS DATE J I 1 I L77� rI INSPECTOR GENERAL INSPECTION REPORT ( 518 ) 761 - 8256 (30 Town of Queensbury Dept, of Community Development Date inspection request received: �G') Building & Code Enforcement 742 Bay Road Queenshury, NY 12804 Arrive am/pm Depart antlpin inspector's Initials ,r I� �':L NAME: PERMIT # LOCATL N: DATE : TYPE OF STRUCT[.TR : RECHECK NIA YES NO COMMENTS Footings/Piers f Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from ng for 48 hours following the p ent of the concrete. Materials for this purpose on s' Foundation/W'allpour Reinforcement in Place Foundation/Daxnpproobng Backtiill Approval Plumbing Under Slab �iumtring Ventli7ent ' i J A j ROTn Plumbin {rV `r i�/ r.. G - / vet ; r_ t h �= J S�C - r" J=} vieating Rough-In Insulation Foundation Walls In rior R- Foundation Walls E or R- Floors R- Walls R- Ceiling R- Duct work or piping unheated spaces R- r Vent, ,Attu Vent ranting, Jack Studv`H- aders Bracing/Bridging, > Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed W 4 ho Firestppping k E,V / v - u v floq 7 TOWN OF [ WEEKSWRY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbu+ry_ NY JZB04 (5I8) 761-9256 SEPTIC DISPOSAL SYSTEM INSPECTION Name is>tlf S t rJ7n �r 10 ,,,z Ka " Location 3 Date ` .� Permit #_ SOIL TYPE: an oam-Clad_ Results of Percol a ion Tes ( i f applicable ) fiat -Minute nch_ �, x TYPE OF SYSTEM: z.250- ABSORPTION FIELD : To 7 L n tt Length of each trench Depth of trenche 3 Size of stone c SEEPAGE PITS : umber- t , Size - .. ft . x � Stone size PIPING: o1►z Ype3 Bldg . to Tank Tank. to 'Dist . Box i6 � Dist . Sox to Field/Pit Openings Sealed? Yes u a LOCATION/SEPARATIONS : feet'''-. Foundation to Tank Foundation to Absorption _2-C' feet Separation of Pi is -""fifes No Conforms as per Plot Plan LOCATION OF SYSTEM ON PROPERTY : ones front Rear - ide - Right Side I l e Front -- Middle Rear GENTS ; SYSTEM USE APPROVED : YES ND Arrived: Departed= Building Inspector GENERAL INSPECTI©N REPQRT { 518 } 761 - 8256 Town of Queensbury DePL of Community Development Date inspection request received: '1jQ — .Building & Code Enfareement 742 Bay Road Queensbury, NY 12804 Arrive am/pm Depart�' _ Inspector's Initials �NAME: ( 4t c `�_L�J i 1 PERMIT # LA3CATION• PdXk4 9 4 _ DATE : S TYPE OF STRUCTURE: —' RECHECK N/A YES NO COMMENTS Footinggs/Mers Monolithic Pour Form Reinforcement in Place The contractor is respousitble or ng protection from ing for 48 following the a nt of the con Materials for this site Foundation/Wallpanr Reinforcement in Place •--�F undation/Uamppaoofi aclr�t3l Appravat Plumbing Under Slab Plumbing Vent/Vent in Place ]tough Plumbing Beating Rough.ln Insulation Foundation Wifils Interior R- Foundation Exterior R- Floors R- walls R- Ceiling R- Duct work or piping, in unheated. spaces R- Proper Vent, Attic Vent Franu Tack Studs/Headers Bracing/Bridgin Joist Hangers lack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppi GENERAL . J-V51- ECnaJVREPO T ( 518 ) 761 -8256 Tawas of Qiueensbucy Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive am/pin Depart Inspector's Initials NAME: .� G J4�+L- �.� ikhn PERmrr # O LOCATION: DATE fl TYPE OF STRUC T"UIM.- RECHECK N/A YES NO COMMENTS Footit;<gsJPiers —�j Monolithic Pour Form. Reinforcement in Place The contractor is responsible for providing protection from fr+wzing for 48 hours following the pIacern t of the concrete. Materials for this purpose on site Foundation/Wallpour Rei5forcement in Place ndatianfDampproaftn. U Backfill Approval Plumbing Under Slab &b Plumbing Vent/Vents in Placd Rough Plumbing Heating Rough-In Insulation Foundation Walls Irate r R- Foundation Walls Exl 'or R- Floors R- Walls R- Ceiling R- Duct work or piping n unheated spaces R- Proper vent, Attic Ven Framing Jack Stoxis/Headerd Sracinr,M idgi Joist llangers Jack Posts/Main Beata Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761 - 8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road ?� Queensbury, NY 12804 Arrive am/pra Depart `.-.,�. anvlxn Inspector's lniitttli�ais `+.J NAME: PERMIT 4 CfCJ LOCATION: BATE TYPE OF STRUCTURE: RECHECK NIA YE O CONIMENTS ^r'FootingslPlers I Monolithic Pour Form �- ReiMorcement in Place The contractor is respo for providing protection from ing for 48 hours fallowing the ment of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Danipproofin BackFdl Approval Plumbing Under slab Plumbing VentlVents in Place Rough Plumbing, Heating Rough-In Insulation Foundation Walls Interior R.- Foundation Was Exterior R- Floors R- Walls R- Ceiling R- Lkwt work or piping in unheated spaces R- Proper Vent, Attie Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack PostslMain Benin Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall. 2, 3, 4 hour Firestoppin GENERAL MaPECTION REPORT ( 518 ) 761 - 8256 Town of Queensbury Dept. of Community Development Date inspection request received: p l'S Building & Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive am/pm Depart Inspector's Initials rm NA AE: * S PERMIT 41 I.00ATIQN. DATE : r TYPE OF STRUCTURE: f RECHECK � L7 , N/A YES NCI CC73�NTS ttgs/Piers Monolithic four Form ` Reinforcement in Place The contractor is responsible for providing protection from fteezing �---- for 48 hours following the placement of the concrete. Materia s for this purpose on site Foundation/Wallpour p } Reinforcententin Place OC l V Foundatiosu�Dampp Back#"ili Approval Plumbing Under Stab Plumbing Vent/Vents in Place 11 Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic rent Framin Jack Studs/Headers Bracing/Bridging, Joist Hangers Jack Poosts^Wn Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 27 37 4 hour Firestoppi TObW OF QUEENSBURY BUILDIRs CODE ENFORCEMENT 742 Bay Road 4ueensb+ury -NY _-12_ 804 `(518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name Location +Lo � 7 9 ) �F p & ...vo Date F Bt? Permit # 67D SOIL TYPE, Sand- Loam-Clay- Results of Percolation Test- ( if applicable ) Rate- Minute/ finch TYPE OF SYSTEM: ABSORPTION FIELD: Total Length Length of each trench Depth of trenches Size of stone SEEPAGE PITS : Nufnbe r- Size - ft . x ft , Stone size _` PIPING : Size ype Bldg . to Tank Tank to Dist . Box Dist . Box to Field/Pi t~'�" Openings Sealed ? Yes'��Vo` Pa rta a L OCATI OI�E/sEP'ARATIONS Foundation to Tank Foundation to Absorption 'Feet 'Feet Separation of Pits feet Conforms as LOCATION OF SYSTEMoONPPaROPERTY, No ( circle one) Front - Rear - Left Side - Right Side Middle Front - Middle Rear 711 SYSTEM USE APPROVED.: YES NO Arrived : Departed: B{Ji I dt ng Insp ctor 169 Haviland Road, Queensbury, NY 12804 Phone - 5l 8-745-4400 Fax - 518-792-851 1 �' ` j 31�L� September 13 , 2000 Mr. Paul Lambert The Michaels Group 10 Blacksmith Drive Suite 1 Malta, NY 12020 $ Ep 93 2000 RE: Hudson Pointe PUD , , Construction Services File #46109 Dear Paul, Today I performed a percolation tests on lots #80 & 81 in the Hudson Pointe PUD. These tests were performed in the approximate location of the proposed septic systems, at a depth of 24 to 30" below existing grade. The soils in the location of the septic system are fine to medium sand with cobbles and a trace of silt on lot #81 . On lot #80 the soils are medium to coarse, relatively compact sand with a trace of silt. The stabilized percolation rates (after adequate presoaking) were one minute and five seconds an lot #81 and one minute on lot #80. I will perform the percolation test on lot 479 after the area in the vicinity of the leach field has been brought up to finish grade. Since the fill being used here is relatively loamy, please be sure that the contractor does not compact the material with a rubber tire vehicle. The material should be lightly compacted with a track vehicle only. Please call me if you have any questions. Sincerely, Thomas W. Nace, P.E.