Signed Inspection Report (Wed Jan 11, 2023 at 155 PM)INSPECTION WORKSHEET (RESFINAL-023110-2023)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:P20140055-40679 Case Module:Permit
Inspection Date:Wed Jan 11, 2023 Inspection Status:Failed
Inspector:Dyer, Charles Inspection Type:Residential Final Inspection
Job Address:Parcel Number:252 AVIATION RD
QUEENSBURY, NY, 12804
301.7-2-26
Contact Type Company Name Name
Primary Owner Mitchell, Jon
Applicant Mitchell, Jon
Granted Permission Mitchell, Jon
Agent David F & Pamela Bruno LLC
Checklist Item Status
General Comments Failed
Jon, please make contact with building department as to close this permit out, will need to verify for a final
electrical inspection with this project.
518-761-8207 1/11/23
CO in bedrooms w/gas appliances Failed
4 inch Building Number Address visible from road Failed
Chimney Height / B Vent / Direct Vent Location Failed
Chimney Rain Cap Installed Failed
Jan 11, 2023 Page (1)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Fresh Air Intake Failed
Fresh air supply 3' from grade Failed
3" Plumbing Vent through roof minimum 18 inch Failed
Outside Spigots have Air Gap Failed
Roof Complete / Exterior Finish Complete Failed
Platform at all exterior doors Failed
Handrail 4 or more risers Failed
Guards at stairs,decks,patios 30" + above grade Failed
Guard at stairwell at 34" or more Failed
Window guards req:<2' above floor/6' above grade - quick release installed Failed
Guard at deck, porches 36" or more Failed
Handrail Termination at Newell Post or Wall Failed
Jan 11, 2023 Page (2)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Interior/Exterior Railings 34 to 38 Failed
Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Failed
4+ Deck Joist Ledger Connections-24" From Ends Failed
Deck Ledger-Bolted per Code Failed
Grade away from foundation: 6" down, 10' out Failed
6" clearance to sill plate Failed
Gas Shut-off Exposed & Regulator 12" min abv grd Failed
HVAC Vent Terminal 10' from Lot Line & Openings Failed
Dryer Duct Max Length 35', Labeled Over 35'Failed
Interior privacy/trim/doors/main entrance 36 Failed
Bathroom / Kitchen Watertight Failed
Jan 11, 2023 Page (3)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Failed
Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs Failed
Smoke Detectors:Failed
3' from Kitchens & Baths R314 Failed
Every level, Every bedroom Failed
Outside every bedroom area Failed
Battery backup: _____Failed
Inter Connected Failed
Carbon Monoxide Detectors:Failed
within 10' of all sleeping areas Failed
bedroom(s) with gas appliances Failed
on all levels w/gas appliances (i.e. furnace)Failed
Jan 11, 2023 Page (4)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Attic Access 22 x 30 minimum Failed
Attic Access Insulation = Attic R- Value Failed
Attic Access Gasketed Failed
Foam in basement/attics covered w/thermal barrier Failed
Knee wall/Crawl space 18" x 24"Failed
Pull down stairs boxed out and insulated Failed
Crawl space/knee wall access insulated & gasketed Failed
Bathroom Fans, if no window Failed
Plumbing fixtures Failed
Backflow Preventors where required Failed
Foundation insulation to floor Failed
Jan 11, 2023 Page (5)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Energy Sticker on Elec. Panel:R-Val. & Heating Sys Failed
All Hot Water Systems: 3/4" or larger piping R-3 Failed
Duct work sealed properly Failed
Intake Openings Failed
Range Hood 400+ cfm-Fresh Air REQUIRED Failed
Blower Door Test Certification Failed
HRV or ERV Installed per Bedroom Requirements Failed
Floor truss, draft stop- fin base 1,000 sq. ft.Failed
Emergency egress below grade Failed
Furnace shut-off w/in 30 ft. or w/in line of site Failed
Oil Furnace Shut-Off at Entrance to Furnace Area Failed
Propane Tank: Proper Setback from Prop Line/Struct Failed
Jan 11, 2023 Page (6)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Furnace/Hot Water Heater operating Failed
Low water shut-off boiler Failed
Relief Valve ,Heat Trap/Water Temp 110 deg or less Failed
Hot water drain pan to indirect waste - receptor or exterior Failed
Encl. Stairs Sheetrock Underside minimum ½ Gypsum Failed
1/2" Gypsum or House Wall and Gable Failed
5/8" Type X with Living Space Above Failed
20 Minute Fire Door/Self-Closing Hardware Failed
Seals on Garage Doors, esp. Wood Failed
Basement stairs closed rise greater than 4 inches Failed
Basement wall insulation R- value verified Failed
Jan 11, 2023 Page (7)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
Basement Egress: 5s.f. window w/sill or Bilco door Failed
Basement ceiling covered 2x8 fl joist or less Failed
Jack posts in basement lagged at top and bottom Failed
Fireblocking at fl joist 80 s.f. or less Failed
Garage Floor Pitched Failed
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss Failed
Gas Log In Sealed or Glass Enclosure Failed
Fin Elect; Energy Saving Light Bulbs 50 Percent Failed
CSST/other piping in conduit if buried,if required Failed
Final Survey Plot Plan Failed
Arc Fault Breaker Habitable Spaces Failed
Flex Gas Pipe Bonding Failed
Jan 11, 2023 Page (8)
INSPECTION WORKSHEET (RESFINAL-023110-2023)
Checklist Item Status
As Built Septic System Failed
Sewer Dept. Inspection Sticker Failed
Site Plan / Variance required Failed
Flood Plain Certification, if required Failed
Fuel Tanks above flood plain elevation Failed
Buried Fuel Tanks anchored in flood zone Failed
Truss ID Signage Installed at Electrical Meter Failed
Electronic as-builts Failed
OK to Issue Temporary C/O Failed
OK to Issue C/O Failed
Jan 11, 2023 Page (9)
Dyer, Charles