Sign PackageWellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Queensbury, NY
Page 1 of 14
Sign B
Awnings B
Sign E Sign C
Sign A
Sign D
Sweet Rd
Lake George RdAwnings A
Awnings C
Awnings D
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Type:
Illumination:
Square Footage:
To Grade:
Sign A
Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings A
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign B
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings B
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign C
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Viewable Size:
Square Footage:
3/16” White Polycarbonate Panel w/ First
TBD
wellNOW Urgent Care
TBD
TBD
Type:
Actual Size:
Sign E
Surface Applied Vinyl Graphics
Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings D
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellNOW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign D
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings C
*Note: The site plan may change subject to the approval process
Actual Square Footage this Elevation:68.18
Allowable Square Footage:
Formula: 20% of wall area NTE 30sf
30.00
Elevation (North)Front
Scale: 3/16” = 1’-0"
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Type:
Illumination:
Square Footage:
To Grade:
Sign A
Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings A
Page 2 of 14
A1A122'-11 1/4"94"34'-0 3/4"
43'-4"53"EQEQ15'-5 1/4"EQEQ
Elevation ()Right West
Scale: 1/8” = 1’-0"
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Actual Square Footage this Elevation:68.18
Allowable Square Footage:
Formula: 20% of wall area NTE 30sf
30.00
Page 3 of 1422'-11 1/4"83'-0"94"26'-8"53"EQEQ15'-5 1/4"EQ EQ
B1 B3 B4B2
Standing Seam Metal Awning
Non-Illuminated
wellN OW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings B
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign B
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Elevation ()Left East
Scale: 1/8” = 1’-0"
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Actual Square Footage this Elevation:68.18
Allowable Square Footage:
Formula: 20% of wall area NTE 30sf
30.00
Page 4 of 14
Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings C
22'-11 1/4"94"83'-0"
26'-8"53"EQEQ15'-5 1/4"EQEQ
C2C3 C1
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign C
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Elevation ()Rear South
Scale: 1/8” = 1’-0"
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Actual Square Footage this Elevation:68.18
Allowable Square Footage:
Formula: 20% of wall area NTE 30sf
30.00
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign D
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Standing Seam Metal Awning
Non-Illuminated
wellNO W Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings D
Page 5 of 1422'-11 1/4"43'-4"94"34'-0 3/4"
15'-5 1/4"53"EQEQEQ EQ
D1
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
5”
S ec t i o n @ L E D C han n el L ett er
Scale: N.T.S.
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Type:
Illumination:
Square Footage:
To Grade:
Sign A
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per N EC 600.7/N EC 250
2) Existing branch circuit in compliance with
NE C 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NE C 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
Electrical Detail:
White L EDs
(3) 60w Transformer @ 1.1 amps
Total Amps: 3.3
(1) 20 amp 120V Circuit Req.
¼” Drain holes at
bottom of letter
cans (2) per letter
9
8
10
7
1
2
4
5
6
3
Sign Layout Detail
Scale: 3/8" = 1'-0"
Specifications:
1. Existing Facade: EIFS | Plywood | Wood Stud
2. .040” Pre-finished black aluminum returns
3. 1”Jewelite trimcap (Black) bonded to face, #8 pan head screws to returns
4. 3mm Signabond Lite composite backs fastened to returns w/ 1/2” 18 gauge staples. Seal w/ VO C compliant 360
white latex caulk to prevent moisture penetration. (Interior of sign can painted white for maximum illumination)
5. White LE Ds
6. 3/16” 2447 White Acrylic faces w/ first surface applied vinyl to match:
3M 3630-87 Royal Blue - wellNO W
3M 3630-33 Red - right arm of cross | U RG ENT CA RE
3M 3630-118 Intense Magenta - up arm of cross
Digitally printed 3M IJ3630-20 to match PM S 7446 C Lilac - left arm of cross
3M 3630-75 Marigold - down arm of cross
7. Disconnect switch U L Outdoor rated toggle type w/ neoprene boot per N EC 600-6
8. Primary electrical feed in UL conduit / customer supplied U L junction box
9. Transformers within U L enclosure (removable lid), 1/4” x 1” min screws
10. Mounting hardware:#12 Sheet Metal Screws28"9 3/4"53"15'-5 1/4" [185 1/4"]
7'-11 1/4" [95 1/4"]
17 3/4"
8 3/4"
Page 6 of 14
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per N EC 600.7/N EC 250
2) Existing branch circuit in compliance with
NE C 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NE C 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
Electrical Detail:
White L EDs
(3) 60w Transformer @ 1.1 amps
Total Amps: 3.3
(1) 20 amp 120V Circuit Req.
Sign Layout Detail
Scale: 3/8" = 1'-0"28"9 3/4"53"15'-5 1/4" [185 1/4"]
7'-11 1/4" [95 1/4"]
17 3/4"
8 3/4"
Specifications:
1. Existing Facade: EIFS | Plywood | Wood Stud
2. .040” Pre-finished black aluminum returns
3. 1”Jewelite trimcap (Black) bonded to face, #8 pan head screws to returns
4. 3mm Signabond Lite composite backs fastened to returns w/ 1/2” 18 gauge staples. Seal w/ VO C compliant 360
white latex caulk to prevent moisture penetration. (Interior of sign can painted white for maximum illumination)
5. White LE Ds
6. 3/16” 2447 White Acrylic faces w/ first surface applied vinyl to match:
3M 3630-87 Royal Blue - wellNO W
3M 3630-33 Red - right arm of cross | U RG ENT CA RE
3M 3630-118 Intense Magenta - up arm of cross
Digitally printed 3M IJ3630-20 to match PM S 7446 C Lilac - left arm of cross
3M 3630-75 Marigold - down arm of cross
7. Disconnect switch U L Outdoor rated toggle type w/ neoprene boot per N EC 600-6
8. Primary electrical feed in UL conduit / customer supplied U L junction box
9. Transformers within U L enclosure (removable lid), 1/4” x 1” min screws
10. Mounting hardware:#12 Sheet Metal Screws
5”
S ec t i o n @ L E D C han n el L ett er
Scale: N.T.S.
¼” Drain holes at
bottom of letter
cans (2) per letter
9
8
10
7
1
2
4
5
6
3
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign B
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Page 7 of 14
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per N EC 600.7/N EC 250
2) Existing branch circuit in compliance with
NE C 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NE C 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
Electrical Detail:
White L EDs
(3) 60w Transformer @ 1.1 amps
Total Amps: 3.3
(1) 20 amp 120V Circuit Req.
Sign Layout Detail
Scale: 3/8" = 1'-0"28"9 3/4"53"15'-5 1/4" [185 1/4"]
7'-11 1/4" [95 1/4"]
17 3/4"
8 3/4"
Specifications:
1. Existing Facade: EIFS | Plywood | Wood Stud
2. .040” Pre-finished black aluminum returns
3. 1”Jewelite trimcap (Black) bonded to face, #8 pan head screws to returns
4. 3mm Signabond Lite composite backs fastened to returns w/ 1/2” 18 gauge staples. Seal w/ VO C compliant 360
white latex caulk to prevent moisture penetration. (Interior of sign can painted white for maximum illumination)
5. White LE Ds
6. 3/16” 2447 White Acrylic faces w/ first surface applied vinyl to match:
3M 3630-87 Royal Blue - wellNO W
3M 3630-33 Red - right arm of cross | U RG ENT CA RE
3M 3630-118 Intense Magenta - up arm of cross
Digitally printed 3M IJ3630-20 to match PM S 7446 C Lilac - left arm of cross
3M 3630-75 Marigold - down arm of cross
7. Disconnect switch U L Outdoor rated toggle type w/ neoprene boot per N EC 600-6
8. Primary electrical feed in UL conduit / customer supplied U L junction box
9. Transformers within U L enclosure (removable lid), 1/4” x 1” min screws
10. Mounting hardware:#12 Sheet Metal Screws
5”
S ec t i o n @ L E D C han n el L ett er
Scale: N.T.S.
¼” Drain holes at
bottom of letter
cans (2) per letter
9
8
10
7
1
2
4
5
6
3
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign C
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Page 8 of 14
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per N EC 600.7/N EC 250
2) Existing branch circuit in compliance with
NE C 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NE C 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
Electrical Detail:
White L EDs
(3) 60w Transformer @ 1.1 amps
Total Amps: 3.3
(1) 20 amp 120V Circuit Req.
Sign Layout Detail
Scale: 3/8" = 1'-0"28"9 3/4"53"15'-5 1/4" [185 1/4"]
7'-11 1/4" [95 1/4"]
17 3/4"
8 3/4"
Specifications:
1. Existing Facade: EIFS | Plywood | Wood Stud
2. .040” Pre-finished black aluminum returns
3. 1”Jewelite trimcap (Black) bonded to face, #8 pan head screws to returns
4. 3mm Signabond Lite composite backs fastened to returns w/ 1/2” 18 gauge staples. Seal w/ VO C compliant 360
white latex caulk to prevent moisture penetration. (Interior of sign can painted white for maximum illumination)
5. White LE Ds
6. 3/16” 2447 White Acrylic faces w/ first surface applied vinyl to match:
3M 3630-87 Royal Blue - wellNO W
3M 3630-33 Red - right arm of cross | U RG ENT CA RE
3M 3630-118 Intense Magenta - up arm of cross
Digitally printed 3M IJ3630-20 to match PM S 7446 C Lilac - left arm of cross
3M 3630-75 Marigold - down arm of cross
7. Disconnect switch U L Outdoor rated toggle type w/ neoprene boot per N EC 600-6
8. Primary electrical feed in UL conduit / customer supplied U L junction box
9. Transformers within U L enclosure (removable lid), 1/4” x 1” min screws
10. Mounting hardware:#12 Sheet Metal Screws
5”
S ec t i o n @ L E D C han n el L ett er
Scale: N.T.S.
¼” Drain holes at
bottom of letter
cans (2) per letter
9
8
10
7
1
2
4
5
6
3
Individual Channel Letters
Internally Illuminated w/ LEDs
28” wellN OW Urgent Care [Stacked]
68.18
Type:
Illumination:
Square Footage:
To Grade:
Sign D
Top of Sign to Grade = 19'-1 1/2"
Bottom of Sign to Grade = 14'-8 1/2"
Page 9 of 14
Typical Support Detail:
Rustproof self tapping
#12 x ¾” TEC screws
1” x 1” x 1/8” aluminum tubing
( awning frame )
Hot-dipped galvanized 12 ga.
sheet metal mounting clip
1 1/2"2 "Mounting hardware to suit
1. Existing Facade: TBD
2. Awning Material: .063” Aluminum Standing Seam surface w/ batten covers
at seam risers painted to match PMS 1805 C Regal Red
3. 1” x 1” x .125” Aluminum square tubing frame (wire brush all welds)
4. Open Sides & Bottom
5. Mounting hardware to suit
Specifications:
4
Section- Metal Awning
Scale : N.T.S.
24”
52
1
1”
342”Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings A
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Page 10 of 14
A142"425”
Awning Layout Details
Scale: 3/8” = 1’-0”
Typical Support Detail:
Rustproof self tapping
#12 x ¾” TEC screws
1” x 1” x 1/8” aluminum tubing
( awning frame )
Hot-dipped galvanized 12 ga.
sheet metal mounting clip
1 1/2"2 "Mounting hardware to suit
1. Existing Facade: TBD
2. Awning Material: .063” Aluminum Standing Seam surface w/ batten covers
at seam risers painted to match PMS 1805 C Regal Red
3. 1” x 1” x .125” Aluminum square tubing frame (wire brush all welds)
4. Open Sides & Bottom
5. Mounting hardware to suit
Specifications:
4
Section- Metal Awning
Scale : N.T.S.
24”
52
1
1”
342”Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings B
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Page 11 of 14
B142"336”
B2, B3, B4
Awning Layout Details
Scale: 3/8” = 1’-0”42"96"
Typical Support Detail:
Rustproof self tapping
#12 x ¾” TEC screws
1” x 1” x 1/8” aluminum tubing
( awning frame )
Hot-dipped galvanized 12 ga.
sheet metal mounting clip
1 1/2"2 "Mounting hardware to suit
1. Existing Facade: TBD
2. Awning Material: .063” Aluminum Standing Seam surface w/ batten covers
at seam risers painted to match PMS 1805 C Regal Red
3. 1” x 1” x .125” Aluminum square tubing frame (wire brush all welds)
4. Open Sides & Bottom
5. Mounting hardware to suit
Specifications:
4
Section- Metal Awning
Scale : N.T.S.
24”
52
1
1”
342”Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings C
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Page 12 of 14
C142"336”
C2, C3
Awning Layout Details
Scale: 3/8” = 1’-0”42"96"
Typical Support Detail:
Rustproof self tapping
#12 x ¾” TEC screws
1” x 1” x 1/8” aluminum tubing
( awning frame )
Hot-dipped galvanized 12 ga.
sheet metal mounting clip
1 1/2"2 "Mounting hardware to suit
1. Existing Facade: TBD
2. Awning Material: .063” Aluminum Standing Seam surface w/ batten covers
at seam risers painted to match PMS 1805 C Regal Red
3. 1” x 1” x .125” Aluminum square tubing frame (wire brush all welds)
4. Open Sides & Bottom
5. Mounting hardware to suit
Specifications:
4
Section- Metal Awning
Scale : N.T.S.
24”
52
1
1”
342”Standing Seam Metal Awning
Non-Illuminated
wellNOW Urgent Care
Bottom of Sign to Grade = 8'-5 3/4"
Type:
Illumination:
To Grade:
Awnings D
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
Page 13 of 14
D142"425”
Awning Layout Details
Scale: 3/8” = 1’-0”
WellNow Urgent Care
WN-A27863
920 Lake George Road
Queensbury, NY 12804
08/05/2022
08/10/2022
Original Renderings
Updated Elevation Renderings
AN
AN
This rendering is the property of Anchor
Sign, Inc. It is for the exclusive use of
Anchor Sign, Inc. and the party which
reque ste d the r en derin g. It is an
unpublished original drawing not to be
distributed, reproduced or exhibited
without the consent of Anchor Sign, Inc.
Please contact your account manager
with questions regarding this statement.
Client:
Site #:
Address:
New Replacement Vinyl -Existing D/F Pylon
Scale: 1/2” = 1’-0”
1. Existing 3/16” White Polycarbonate
2. New applied vinyl digitally printed to match:
3M 3630-87 Royal Blue - wellNO W
3M 3630-33 Red - right arm of cross | URGE NT CARE
3M 3630-118 Intense Magenta - up arm of cross
Digitally printed 3M IJ3630-20 to match PMS 7446 C Lilac - left arm of cross
3M 3630-75 Marigold - down arm of cross
3. Existing retainers [Visual Opening]
Specifications:
Existing
QTY: 2 [1 SET]
Proposed
Viewable Size:
Square Footage:
3/16” White Polycarbonate Panel w/ First
TBD
wellNOW Urgent Care
TBD
TBD
Type:
Actual Size:
Sign E
Surface Applied Vinyl Graphics
Page 14 of 14
1
2
3