Loading...
RC-0401-2022 _ Office Use Only ADDITION/ALTERATION PERMIT Permit#: Q-C — (Ki.OI ' 20VL APPLICATION Permit Fee:$ —' Town of cZeensbury 742 Bay Road,Queensbury,NY 12804 Invoice#: 5� P:518-761-8256 www.gueensbury.net �^ Flood Zone? Y Reviewed By:IL Project Location: 22 Wilson Street Tax Map ID M 302.8-2-53 Subdivision Name: PROJECT INFORMATION: TYPE: X Residential Commercial, Proposed Use: X Single-Family _Two-Family _Multi-Family(#of units ) Townhouse Business Office _Retail _Industrial/Warehouse _Garage (#of cars_) Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 264 1st floor: 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement(habitable space): Basement(habitable space): Total sq ft: 264 Total sq ft: Scope of work to be done: Project is to remove a portion of the existing open deck and construct a new, thermally isolated, sunroom addition to the existing single family residence. Sunroom will contain a natural gas fire place that is for ambiance only and is not considered a heat source. M E E 2 5 2022 QUEENSBURYG & CODES Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 100,000 2. Source of Heat(circle one):_Gas _Oil _Propane _Solar_Other thermally isolated sunroom Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES XNO Explain: 4. Are there any easements on the property? YES . X NO SITE INFORMATION: • Is this a corner lot? X YES NO • Will the grade be changed as a result of the construction? _YES X NO • What is the water source? X PUBLIC _PRIVATE WELL • What type of wastewater system is on the parcel? XSEWER _PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of 4ueensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are atrue and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ethan P. Hall -�(Arrchitect\Agent for the Applicant SIGNATURE: �� r DATE: 25 June 2022 Addition/Alteration Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Tim and Jane Badger Mailing Address, C/S/Z: 22 Wilson St, Queensbury NY 12804 Cell Phone: 518 )338-7593 Land Line: �) Email: gouldbadger@gmail.com Primary Owner(s): Name(s): Tim and Jane Badger Mailing Address, C/S/Z: 22 Wilson St, Queensbury NY 12804 Cell Phone: 518 )338-7593 Land Line: Email: gnuldf,adger_gmail cnm ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Alpha Construction Contractor Trade: General Contractor Mailing Address, C/S/Z: 72 E Farmwood Road, Fort Ann NY 12827 Cell Phone: ( 518 )260-3308 Land Line: � ) Email:_alpha@alpha-construction.biz **Workers' Comp documentation must be submitted with this application** • Arch itect(s)/Eneineer(s): Business Name: Rucinski Hall Architecture Contact Name(s): Ethan P. Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone: 518 )260-2888 Land Line: 518 )741-0268 Email:ephall@nycap.rr.com Contact Person for Compliance in regards to this project: Ethan P. Hall Cell Phone: 518 )260-2888 Land Line: 518 )741-0268 Email: ephallOnycap.rr.com Addition/Alteration Application Revised January 2021 Office Use Only ~ Permit#: !Tow,okecnbuy Permit Fee:$ 742 Bay Road, Queensbury, NY 12804 P:518-761-8256 www.gueensburv.net Invoice#: FUEL BURNING APPLIANCE & CHIMNEY APPLICATION **ONE APPLICATION PER APPLIANCE** Project Location: 22 Wilson St Tax Map ID#: 302.8-2-53 Room of Install: Sunroom Planned Install Date: Sept. 2022 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _ Fireplace Insert X Fireplace _Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) X Fireplace,factory built** (**Manufacturer's name: Mendota Model #: FV41 Arch ) SOURCE OF HEAT: Wood _Coal _ Pellet X Gas CHIMNEY INFORMATION: Masonry (require plans to be submitted): block brick stone _ Flue: _the _steel _size, in inches X Material*: X double-wall _triple-wall _insulated (*Manufacturer's name: Mendota Model#: FV41 ) Principle Structure Packet Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Installer/Builder: Workers' Comp documentation must be submitted with this application Contact Name(s): Alpha Construction Contractor Trade: General Construction Mailing Address, C/S/Z: 72 E Farmwood Road, Fort Ann NY 12827 Cell Phone:_(518 )260-3308 Land Line: _( ) Email:alpha@alpha-construction.biz Contact Person for any questions regarding this project: Ethan P. Hall Cell Phone: 518 )260-2888• Land Line: 518 )741-0268 Email: a hn�ll=nyrap rr rnm ADDITIONAL INFORMATION: 1. Two(2) inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces &chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. S. Workers' Comp insurance information is required with this application. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: Ethan P. Hall-Architect\Agent for the Applicant SIGNATURE: �� DATE: 25 June 2022 Principle Structure Packet Revised January 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) Two (2) full sets of plans -( Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 115,Wind Floor Loads 40 psf (North of Rte. 149 60) 50,Ground Snow Load Sleeping Areas &Attics 30 psf W31Calculations Decks 40 psf Wind design for lake front properties t/�J Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for I windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door Emergency Escape or Bedrooms & Habitable Space Above-grade: 5.7 sq. ft. Grade: 5.0 sq. ft. 24" (h) x 20" (w) minimum 44" maximum height above door Window control devices 24" or less 2"d story or 72" above grade Egress window from basement 5.0 sq. ft. i -ej Floor system sizing per table 502.3.1 Residential check ERI-or Prescriptive method Driveway length: 300' or more-12' width required/500' or more, turnaround required Foundation drainage on plans, if required 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10' where required/joist spans pg. 127 Ice & snow shield—24" from exterior wall Platforms at exterior doors Stairway headroom 6'8"; all stairs 36" width Stair run and rise Winder run and rise Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Bathroom fixtures—proper clearance Hall width-36" width Handrails more than four risers on open sides Railing &guards > 30"/basement stairs included/closed risers more than 4" in height Safety glazing notes for required areas Garage fire separation: %" gable end/5/8" under living space &%" on walls/20 min. door and closer A/ Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation Roof over 30"—22" x 30"/Crawl spaces 18" x 24" access Continued on back 4 4 Residential Plan Review Revised October 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) / Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected !✓ within 15' of sleeping area Soil test results, if required U Septic to well or water line separation All paperwork signed jA Note on plans energy saving light bulbs 90% Blower door test agency paperwork j Q Floodplain Permit required —check map: 2 feet above flood elevation Hurricane clips required Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel Manuals S &J required for heating system. Cold air return hard piped Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations Baffles at eaves for insulations and knee walls Makeup air for range hood >400 cfm Continuous header for garage doors to end wall Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised October 2021