1.1 1.1
WASTEWATER-SEWER\APPROVE\Barlow David-Holding Tank Replacement System and Time Extension-APA-2-13-2023
RESOLUTION APPROVING DAVID BARLOW'S APPLICATION FOR
SANITARY SEWAGE DISPOSAL VARIANCES
RESOLUTION NO.: 12023
INTRODUCED BY:
WHO MOVED ITS ADOPTION
SECONDED BY:
WHEREAS, David Barlow (Applicant) filed an application for a variance from provisions of
the Town of Queensbury On-Site Sewage Disposal Ordinance, Chapter 136, §136-11 which requires
applicants to obtain a variance for holding tanks as the Applicant wishes to replace a wastewater
system by installing a holding tank system consisting of two (2) holding tanks each with a capacity of
1,500 gallons for a total capacity of 3,000 gallons, thus meeting and exceeding the required total
capacity of 2,000 gallons on property located at 22 Ward Lane in the Town of Queensbury, and
WHEREAS, Town Code Chapter 137 requires inspection of Onsite Wastewater
Treatment Systems (OWTS) prior to the sale of certain real property and provides that a $2,000
escrow deposit will be forfeited to the Town in the event that completion of a wastewater
treatment system meeting all standards is not completed within the time provided, and
WHEREAS, a change of deed for the Applicant's property occurred on or about
September 1, 2022 and when the required property transfer septic inspection took place, it was
found that the existing wastewater system was deficient; however, the proposed new system is not
able to be completed within the required six (6) month time period due to the time of year and
timing of permitting, and
WHEREAS, the Applicant therefore applied for a timeline extension or until June 3rd, 2023
to install the system and to extend the date on which the $2,000 escrow deposit he previously
deposited with the Town shall be automatically forfeited to the Town, and
WHEREAS, the Town's Director of Building and Codes Enforcement has recommended
Town Board approval of this requested extension, and
WHEREAS, the Town Clerk's Office published the Notice of Public Hearing in the Town's
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
variance request on Monday, February 13t', 2023, and
WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners
within 500 feet of the subject property,
NOW, THEREFORE, BE IT
RESOLVED,that
1. due to the nature of the variance, the Local Board of Health determines that the
variance would not be materially detrimental to the purposes and objectives of this
Ordinance or other adjoining properties nor otherwise conflict with the purpose and
objectives of any Town plan or policy; and
2. the Local Board of Health finds that the granting of the variance is necessary for the
reasonable use of the land and is the minimum variance which would alleviate the
specific unnecessary hardship found by the Local Board of Health to affect the
Applicant; and
BE IT FURTHER,
RESOLVED, that the Local Board of Health hereby approves the application of the David
Barlow for a variance from the Sewage Disposal Ordinance to allow installation of a holding tank
system consisting of two (2) holding tanks each with a capacity of 1,500 gallons for a total capacity of
3,000 gallons, thus meeting and exceeding the required total capacity of 2,000 gallons on property
located at 22 Ward Lane in the Town of Queensbury and bearing Tax Map No: 240.6-1-6, and
BE IT FURTHER,
RESOLVED, that the Local Board of Health further authorizes and grants the Applicant
additional time to obtain a certificate of compliance from the Town's Building and Codes
Enforcement Office as set forth in Chapter 137 to install the holding tank system and extends the
date on which the $2,000 escrow deposit the Applicants previously deposited with the Town be
automatically forfeited to the Town until June 3a 2023 and authorizes and directs the Director
of Building and Codes Enforcement to take any and all actions necessary to effectuate the terms
of this Resolution, and
BE IT FURTHER,
RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by
certified mail a certified copy of this Resolution to the Adirondack Park Agency (APA) for its review,
and
BE IT FURTHER,
RESOLVED, that this approval Resolution shall not be effective until 30 days after such notice
to the APA and shall be subject to review by the APA during such period.
Duly adopted this 13t'day of February, 2023,by the following vote:
AYES
NOES
ABSENT:
169 Haviland Road
�■ ',. Queensbury, NY 12804
Hutchins Engineering PLLC Phone. (518) 745-0307
Fax: (518) 745-0308
December 22, 2022
Town of Queensbury Town Board
Board of Health r
742 Bay Road • G'% I nn
Queensbury NY 12804 U
DEC 2 7 2022
Re: Dave Barlow ` ` '%
22 Ward Lane r�
Tax Map ID: 240.6-1 -6 TOWN OF QUE-1= ASBURY
BUILDING & CODES
Dear Supervisor Strough & Town Board Councilmen:
This office represents Mr. Dave Barlow with respect to the pursuit of wastewater variances for a
holding tank system installation at his property located at 22 Ward Lane. Presently the home is
served by a unknown sized seepage pit which is far from adequate and they desire to bring the
parcel up to the town's current on-site wastewater system standards. Given the terrain and site
constraints, it is not feasible to install an absorption field system, therefore we are pursuing the
holding tank system. A change of Deed for the property occurred on September 1 , 2022_ The
required septic inspection found the existing wastewater system to be deficient.
Presently the house is served by a seepage pit, which is far from adequate and the applicants
desire to install (2) 1500-gallon tanks to support the existing 1 -bedroom cottage.
Relief is requested for the installation of the holding tank system which is detailed in the
application .
We are also requesting a 6 month extension from the property transfer law requirements for the
installation of the holding tank system and force main,
Enclosed please find ten submission packages for this project. We respectfully request, if
possible, that this item be placed upon the agenda of the next town board meeting. Please
contact me if you have any questions or if you require additional information .
Best Regards,
Thomas R. Center Jr. , P.E.
Associate - Design Engineer
Cc_ Dave Barlow
.r-
SEPTIC VARIANCE Office Use Only
Perrnit #:
APPLICATION Permit Fee: $
Town oar
742 say Road, Queensbury, IVY 128" Invoice #:
P: 518-761-8256 www aueensbury net Approvals:
Submittal: 1 (one) original & 8 copies of the completed application package
PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
Section 1:
Contact Information:
PropertyOwner(s): DAVID BARLOW Owner's Agent: HUTCHINS ENGINEERING, PLLC
Address: 162 HUDSON POINT Address: 169 HAVILAND ROAD
QUEENSBURY,NY 12804 QUEENSBURY,NY 12804
Phone #: 518-955-1 180 Phone #: 518-796-2515
Email: Email: TCENTER360YAHOO.COM
Section 2:
Site Information.
Site Address: 22 WARD LANE Tax ID#: 240.6-1 -6
Directions to Site: RIDGE ROAD TOWARD LAND.
Section 3•
Distance from well on property to septic system (if applicable) N/A feet
Section 4:
Is it possible to install a conforming septic system on this property? ❑ Yes Q No
If YES, please explain and attach a diagram:
Section S•
Does the proposed system meet setback requirements for distance from wells & septic systems on neighboring
properties? OYes ❑ No If NO, please explain:
Section 6•
Is the proposed system to be installed under a parking area? Q Yes fN�j No
Section 7•
Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. Teaching system will be 89 ft,
from well in lieu of required 100 ft.): VARIANCE REQUEST TO INSTALL HOLDING TANKS SEC. 136-11 .A)
Septic Variance Appl Kati an Revised December 2021
i
Section 8•
List the names, parcel addresses, and tax map numbers of all adjoining property owners . You may obtain this
information from the Town of Queensbury's Assessor's Office:
North Name DAVID BARLOW
Address 18 WARD LANE
Tax Map ID 240.E-1 -7
South Name DAVID DICKEY
Address 2445 RIDGE ROAD
Tax Map ID 240,6-1 -2
East Name SAME AS SOUTH
Address
Tax Map ED
West Name NONE
Address
Tax Map ID
Section 9•
OWNER STATEMENT
I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
. I/We realize that putting the well, septic tank or leaching system less than the required feet
from the may increase the risk of pollution.
Owner--•Print Name:
Owner—Signature: Crate:
Section 10•
NEIGHBOR OR TENANT RELEASE STATEMENT (if applicable)
VWe do hereby relieve the Town of Queensbury from any liabilities an the plumbing and septic system located at:
I/We realize that putting the well. septic tank or leaching system less than the required feet
from the may increase the risk of pollution.
Neighbor/Tenant—Print Name :
Neighbor/Tenant-Signature: Date:
Septic Variance Application Revised December 2021
` S
T
PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION.
1. A location map showing the site within the Town of Queensbury
2. A plot plan showing existing and proposed features of the property, including:
a. Lot dimensions
b. North arrow and scale: 1 inch=40 feet
c. Location & dimensions of existing and proposed buildings, showing setback distances and
lases
d . Parking layout to scale (if applicable)
e. Physical features (street, steep slopes, lakes, wetlands, etc.)
f. Location of all wells and septic systems on neighboring properties
g. Adjacent ownerships
h . All properties within 500 feet
A sample plot plan and location are shown below:
am hilit Leembn Map!!
rOWN
4 ,
J+ � LwAy • SMI�
t MfJLOC �_ 1
nax xw
Septic Variance Application Revised December 2021
' r
Section 11•
AUTHORIZATION AND SIGNATURE PAGE
This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site
visits, other permit responsibilities and agreement to provide documentation required.
Complete the following if the OWNER is using an Agent:
Owner's Name: DAVID BARLOW
Designates: HUTCHINS ENGINEERING as agent regardingthe Septic Variance for
Site Address: 22 WARD LANE
Tax Map #: 240v6- 1 W6
Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic
design, storm drainage, etc. as determined by the Town Board of Health . Fees for engineering review services
will be charged directly to the applicant.
Authorization for Site Visits: By signing this page and submitting the application materials attached herein, the
Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code
Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the
application submitted.
Please Note: Other permits may be required for construction or alteration activity subsequent to approval by
the -Town Board of Health . It is the applicant's responsibility to obtain any additional permits.
Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated
stenographer tape record the proceedings of the meetings resulting from the application, and that the
minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy
between such record and the handwritten minutes taken by the designated stenographer, the handwritten
minutes shall be deemed the official record.
I, the undersigned, have thoroughly read and understand the instructions for submission; agree to the
submission requirements and completed checklist:
OWNER—PRINT NAME: DAVID BARLOW
OWNER—SIGNATURE: S1,>a" DATE: 11 z z ZZ z-
AGENT- PRINT NAME : THOMAS CENTER, HUTCHINS ENGINEERING
AGENT—SIGNATURE: -' DATE : �Zz ?/Z �
Septic Variance Application Revised December 2021
IPF -
IPF
DISTURBS[
ti Land:
argare
k ,I
Tax M Parc
IPF C
illli'i I
HOIDINGETANKS PLAN
GRAPHIC SCALE
APPROXIMATE
FINISH GRADE
4" SDR-35 PVC 3"
INLET
MIN. SLOPE
1/4" PER FOOT 16"
6"+
POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
4" PVC SDR-35
CONNECTOR PIPE
INSTALLED LEVEL
SEALED WATERTIGHT
507CAPACITY
WATERTIGHT SLEEVE
(1500 GAL)
AND SEAL (TYP.)
WARNING LEVEL
ALARM LIGHT ON
1500 GALLON
INJECTION MOLDED
POLYMER SEPTIC TANK
INSTALLED AS HOLDING TANK
67f PEA GRAVEL
5 0 2.5 5 10 20
( IN FEET )
POLYETHYLENE EXTENSION CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
1500 GALLON
INJECTION MOLDED
6"+ POLYPROPYLENE SEPTIC TANK
_,I— — — — — INSTALLED AS HOLDING TANK
J LIQUID LEVEL
INSTALL FLOAT SWITCHES
TO OPERATE ALARM PANEL
AT INDICATED LEVELS 959 CAPACITY
(4275 GAL)
ALARM/SHUT DOWN
ALARM ON
HOLDING TANKS IN SERIES DETAIL
NTS
67± PEA GRAVEL
HOLDING TANK NOTES
WASTEWATER SYSTEM DESIGN
1—BEDROOM DESIGN
WATER SAVING FIXTURES — REPLACE EXIST. FIXTURES AS NEEDED
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW — 110 GPD/BEDROOM
SYSTEM DESIGN FLOW — 110 GPD
HOLDING TANK DESIGN
NYSDOH SIZING — 5—DAYS DESIGN FLOW — 550 GALS
TOWN OF QUEENSBURY HOLDING TANK VOLUME REQUIRED:
2000 GAL — §136-11 B.(2)
INSTALL (2) 1500 GAL POLYPROPYLENE TANKS IN SERIES
3000 GAL TOTAL TO BE PROVIDED
POTABLE WATER SUPPLY IS EXISTING LAKE WATER SUPPLY
— RELAY TO BE INSTALLED ON WATER PUMP CIRCUIT TO SHUT DOWN
WATER SUPPLY TO HOUSE WHEN ACTIVATED BY WARNING/SHUT
DOWN ALARM ON PANEL
HOLDING TANK ALARM NOTES
ALARM PANEL CONTROLS SHALL BE SJE RHOMBUS TANK ALERT DUO
ALARM SYSTEM OR EQUIVALENT, AND PROVIDE THE FOLLOWING
MONITORING AND CONTROL FUNCTIONS:
WHEN LEVEL OF TANK REACHES 501w. CAPACITY, ALARM WILL
INDICATE "TANK HIGH LEVEL" WITH A YELLOW LIGHT ON ALARM
PANEL.
WHEN LEVEL OF TANK REACHES 95% CAPACITY, AUDIBLE ALARM
WILL SOUND AND RED LIGHT WILL FLASH, INDICATING "TANK
SHUTOFF LEVEL".
ELECTRICAL INTERLOCK SHALL BE INSTALLED TO DISABLE WATER
SUPPLY UPON REACHING "TANK SHUTOFF LEVEL".
SYSTEM WILL RESET AFTER HOLDING TANKS ARE PUMPED DOWN
TO BELOW THE ACTUATION LEVEL OF "TANK HIGH LEVEL"
ALARM.
AN ELECTRICAL INSPECTION BY A CERTIFIED ELECTRICAL INSPECTION
AGENCY IS REQUIRED AFTER INSTALLATION. ELECTRICAL INSPECTION
SEAL IS TO BE AFFIXED TO ALARM CONTROL PANEL.
SYSTEM MATERIAL SPECIFICATIONS
HOUSE SEWER PIPE
PIPING TO BE 4" SDR-35 OR SCH-40 PVC. INSTALL WITH 1/4" PER FOOT
MINIMUM SLOPE.
HOLDING TANK CONNECTOR PIPE
PIPING TO BE 4" SDR-35 OR SCH-40 PVC. INSTALL LEVEL
BACKFILL MATERIAL
BACKFILL TO BE GRANULAR SAND BACKFILL MATERIAL WITH NO PARTICLES
GREATER THAN 1 ".
VARIANCE SUMMARY
THE FOLLOWING RELIEF IS REQUESTED FROM THE TOWN OF
QUEENSBURY CHAPTER 136 SEWERS AND SEWAGE DISPOSAL:
HOLDING TANK INSTALLATION — §136-11 A.
— INSTALL TWO 1500 GALLON WASTEWATER HOLDING TANKS
REQUEST A 6 MONTH EXTENSION FROM TOWN CODE CHAPTER 137
PROPERTY TRANSFER LAW FOR INSTALLATION OF THE NEW HOLDING
TANK SYSTEM.
W AST N ATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELLS
GLAKE
HOUSE
HOLDING TANK
IV
50'
SO'
lu
ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK
STATE DEPARTMENT OF HEALTH AND SHALL BE OF INJECTION MOLDED
POLYPROPYLENE AS MANUFACTURED BY NORWESCO LOW PROFILE 1500 GAL.
TANK OR EQUIVALENT.
ALL STRUCTURES SHALL BE PLACED ON 6" MIN. COURSE OF CRUSHED
STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE. TANK
SHALL BE SECURED TO BEDROCK WITH EPDXY GROUTED ANCHOR EYEBOLTS
AND THREADED ROD AS PER COUNTER BUOYANCY INSTRUCTIONS PROVIDED
BY TANK MANUFACTURER.
RUBBER GASKETS SHALL BE INSTALLED IN ALL INLETS AND OUTLETS
TANKS ARE NOT APPROPRIATE TO BE INSTALLED IN TRAFFIC AREAS.
TANKS TO BE BACKFILLED WITH CLEAN SAND FILL; NATIVE COBBLY,
BOULDERY SOILS ARE NOT ACCEPTABLE AS BACKFILL MATERIAL.
ALL SEAMS, PENETRATIONS, & ACCESS COVERS MUST BE MAINTAINED
WATERTIGHT BY INSTALLER. FIELD COAT ADDITIONAL PENETRATIONS AS
NECESSARY WITH WATERTIGHT SEALANT.
MAP REFERENCE
BASE MAP INFORMATION FROM "MAP OF SURVEY
OF LANDS OF DAVID BARLOW AND JAMES BARLOW
ON WARD LANE" IN THE TOWN OF QUEENSBURY,
WARREN COUNTY, NEW YORK. DATED NOVEMBER
16, 2022. PREPARED BY WILLIAM M. CURRAN
PROFESSIONAL LAND SURVEYOR.
SITE LOCATION —� LOCATION MAP
H091
DISCHARGE
COVER, HDPE 14" BALL VALVE, PVC
14 FPT CONNECTION
INI,ET GATE VALVE
4 SOCKET WELD,
PVC
BASIN, HDPE To/
O ALARM PANEL
14/6 CABLE
ANTI-SIPHON/CHECK VALVE
28 11 2 .210 n A�NSERYJ)MBL,
[708inml ALARM
IN-S AB
BUR AL ON 19.4 n
DEP H [4941nm
19 ir OFF 14.4 n 63 vol
[492 mm [3671 nrn
47 ial
11.9i
29 in [303mm
737 m 37 in 38 gal
940 rnrIn
SEMI -POSITIVE DISPLACEMENT TYPE PUMP
DIRECTLY DRIVEN BY A 1 HP MOTOR
SGS 4-26-07 - 1/16
DR BY CHK'D DATE ISSUE SCALE
SEWER SYSTEMS
IH091 STATION, DETAIL SHEET
BASIN CAPACITY = 91 GALLONS
NA0056P02
Dig ®safely.
New ®Rork
Call Before You Dig
Wait The Required Time
Confirm Utility Response
Respect The Marks
Dig With Care 800.962- /�J
962
www.digeafelynewyark.com
E-Q%E IH091 GRINDER PUMP DET AIL
SCALE: %IS
TAX MAP # 240.6-1-6
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED
PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.