WASTEWATER-SEWER\SetPUNTackey Replacement System With Ejector Bashi to Home and Ghm Lake-3-20-2023
RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL
VARIANCE APPLICATION OF STEVE MACKEY
RESOLUTION NO.: ,2023
INTRODUCED BY:
WHO MOVED ITS ADOPTION
SECONDED BY:
WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is
authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal
Ordinance, and
WHEREAS, Steve Mackey has applied to the Local Board of Health for variances from
Chapter 136 to install an onsite wastewater treatment system with the:
1. Pumping Station/Ejector Basin to be located 3' from the house in lieu of the required
10' setback; and
2. Pumping Station/Ejector Basin to be located 42' from Glen Lake in lieu of the required
50' setback;
on property located at 14 Genista Lane in the Town of Queensbury,
NOW, THEREFORE, BE IT
RESOLVED, that the Town of Queensbury Local Board of Health will hold a public hearing
on Monday, April 3rd, 2023 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road,
Queensbury, to consider Steve Mackey's sewage disposal variance application concerning property
located at 14 Genista Lane in the Town of Queensbury (Tax Map No.: 289.10-1-37) and at that time
all interested persons will be heard, and
BE IT FURTHER,
RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town
Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice
to neighbors located within 500 feet of the property as required by law.
Duly adopted this 20t'day of March, 2023,by the following vote:
AYES
NOES
ABSENT:
1
r
ENGINEERING , PLLC
March 9, 2023
Town of Queensbury
Attn: Mr. John O'Brien, Director of Building & Code Enforcement
742 Bay Road
Queensbury, New York 12804
RE: OWTS Design, Application & Variance Request
Mackey Cottage
14 Genista Lane
Queensbury, New York 12804
Dear Mr. O'Brien:
Attached please find nine copies of a completed Septic Variance Application, Authorization Forrn, and
the Onsite Wastewater Treatment System (OWTS) design for 14 Genista Lane, Queensbury, New York
12804. These drawings specify replacement of a cesspool located approximately 42' from Glen Lake
with the installation of a Clarus Fusion and new dispersal field.. This proposal will require the following
variances:
(1 ) Pumping station is 3-feet from the dwelling ( 10-feet is required); and
(2) Pumping station is 42-feet from Glen Lake (50-feet is required).
The proposed septic system provides pre-treatment and the dispersal location meets required separation
distances. I have enclosed a check far $ 165 to cover the application fee. Please call if you have any
questions.
Sincerely;
.140
Eric E. Murdock, P-E.
cc: Mr. Steve Mackey, Owner
r
SEPTIC VARIANCE ffice Use only
Received:
APPLICATION Permit *
Tswrn er!L. Mcns r+- �
Permit Fee:
742 Bay Road, Queensbury, NY 12804
P: 518-761-8256 www.queensbury.net Invoice
Approvals: C`G nix:G
Submittal. I (one) original & 8 copies of the completed L ........... .................
application package
Property Owner(s): Steve Mackey Owner's Agent: Eric Murdock, P.E.
Address: 21 MacArthur Drive, Glens Falls, NY 12801 Address: PO Box 6265, Syracuse, NY 13217
Phone #: 518-338-8173_ Phone #: 315-254-6891
Site Address: 14 Genista Lane, Queensbury NY 128014 Tax ID#: 289.10-1-37
Directions to Site: Turn off of Glen Lake Road
Distance from well on property to septic system (if applicable) _NO Well_ feet
Is it possible to install a conforming septic system on this property? ❑ Yes X❑ No
If YES, please explain and attach a diagram:
Does the proposed system meet setback requirements for distance from wells & septic systems on neighboring
properties? ❑ Yes X❑ No If NO, please explain: See below
Is the proposed system to be installed under a parking area? X❑ Yes ❑ No
Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system will be 89 ft.
from well in lieu of required 100 ft.):
1. Ejector basin is 3' from house instead of 10'
2. Ejector Basin is 42' from Glen Lake instead of 50'
eptic Variance Application Revised February 2019
r
List the names, parcel addresses , and tax map numbers of all adjoining property owners. You may obtain tax
map numbers from the Assessor's Office as welt as the names and addresses:
North Name James V Keller
Address 15 Fernwood Road
Tax Map ID 289ACI- 1-34. 1
South Name Glen Lake
Address
Tax Map ID
Fast Name Dave Jenkins
Address 15 Genista Lane
Tax Map ID
West Name Frank Cottone
Address 16 Genista Lane
Tax Map ID 289. 10- 1-38
OWNER STATEMENT
I/We do 'hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at :
14 Genista Lane, Queensbury, NY
I/We realize that putting the well, septic tank or leaching system less than the required 10' feet from the may increase
the risk of pollution.
Owner—Print Name : Steve Mackey Date: March 8, 2023 Owner
Signature: r..�{. Date : March8, 2023
eptkc variance Applp[anan Reviwd February 2019
This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site
visits, other permit responsibilities and agreement to provide documentation required .
Complete the following if the OWNER is using an Agent:
Owner's Narne: Steve Mackey
Designates. Fric Murdock, PE as agent regarding the Septic Variance for
Tax Map #: 289. 10-1-37
OWNER'S SIGNATURE: DATE:
Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design,
stor-n drainage, etc. as determined by the Town Board of Health. Fees for engineering review services wilf be charged
directly to the applicant.
Authorization for Site Visits: By signing this page and submitting the application materials attached herein, the owner,
Applicant and his/her/their agent hereby authorize the Towns Board of Health, building and code Enforcement Officers
and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted .
Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town
Board of Health . It is the applicant's responsibility to obtain any additional permits.
Official Meeting Minutes Disclosure: tt is the practice of the Town Board of Health to have a designated stenographer
tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those
tapes constitute the official record of all proceedings. If there Is a discrepancy between such record and the handwritten
minutes taken by the designated stenographer, the handwritten minutes shall be deemed the official record .
1, the undersigned, have thoroughly read and understand the instructions for submission; agree to the
submission requirements and completed checklist :
OWNER — PRINT NAME: Steve Mackey
yy
t^' . rz+f
OWNER—SIGNATURE : w /' ...-DATE -,
AGENT—PRINT NAME : Eric Murdock,
,. -- PE f
AGE NT—SIGNATURE: j�pE3x-2t _ DATE :
ep'hc variance Application Revised rebrvary 2019
U
JN
Glen lake Road
o` Glen Lake Road � C
sc° W
W
Z0)
r�
N
Z!P
Age 6 ows
X
Doo z W
N L Q
Of Z
SITE LOCATION MAP o � U)
N TS t,.l�- u- m 0
03: 0 N Z
wZ UJ W — �
ZF- > y
of
(n>- D 0
WD0cr Q
Wm I F Lli
z
Y
Q W Q N Q
cy m Q J
(n � a Z
INDEX OF DRAWINGS z w _ `� O
J O W
FIGURE 1 - SITE LOCATION MAP & DRAWINGS INDEX O (Ln O
FIGURE 2 - SEPTIC SYSTEM PLAN W Z J
FIGURE 3 - SELECT DETAILS J C9 �O Q W
FIGURE 4 - SELECT DETAILS U)
"• 1, f FIGURE 5 - SELECT DETAILS
e.. _ FILE NUMBER
7 FIGURE 6 - SELECT DETAILS EEM2021-022
F7 t1rg9s' �� FIGURE 7 - SYSTEM SPECIFICATIONS DATE
2-11-2022
FIGURE 8 - GENERAL CONSTRUCTION NOTES FIGURE NO.
1
I—ONE DEDICATED 115 VOLT,20 AM
ISOLATED ELECTRIC aRCUIT FROM THE MAI DO
EXCAVATING DIMENSIONS ELECTRrAL SERVICE TO FUSION PANEL VARE
SYSTEM L W H I E TB
COMPRESSOR DIRECTLY INTO CONTROL PANEL
I wklww 92
16LW.. I 6w
GND
120 VAC D SNF
INCOMING ALAR
POWER GNO------+.
R,VVR.
Dov.5 (2)
-FOR ILLUSTRATION PURPOSES
GRETIR TO SCHEMATIC LOCATED HIGH WATER 'Ir z
MNEL FOR INSTALLATION ALARM IF c:
REQUIRED �`=�� V 0
D"
INIEt
wam
W w
kEDO"5 m ENn Tao AR
W
Lam
z 00
BLOWER
NOTES: Lo
BLOWER FOR ZF-450 AND 04
1)DIMESIONS"I"AND"E"ARE TO THE BOTTOM OF THE INLET/OUTLET PIPE. ZF-800
2)THE OVERALL HEIGHT DIMENSION"Ll"IS TO THE TOP OF THE NARROW uy
ADAPTER RING. NOT E RISER LTD. Z
3)A RISER COVER COMES STANDARD. ADDITIONAL RISERS ARE PURCHASED
SEPARATELY. nnEm
-ow
LINES amen M F
LINES=—
FUSION 450 — DIMENSIONS & EXCAVATION DETAILS PANEL SCHEMATIC FUSION 450 — AIR COMPRESSOR DETAILS Do z
Li
CK
NTS NTS NTS
FUSION CONTROL PANEL CONTRACTORINSTAU.ER 0
MUST READ&FOLLOW INSTRUCTIONS >-
INSTASOLATED LL ONE DEDICATED 115 VOLT,20 AMP GLARUS INSTALLATION R LLJ 00
1 &PROCEDURES CONTAINED '-) 0
ELECTRIC CIRCUIT FROM THE MAIN IN MANUAL 3: c"I
ELECTRICAL SERVICE TO FUSION PANELVARE _22.5* Z Lj >_COMPRESSOR DIRECTLY INTO CONTROL PANEL LLJ
�INSULATE TOP OF UNIT W/ z I— >
4/1
DWEULING RIGID FOAM INSULATION. z —
DO NOT INSTALL UNDER DRI'I THE OF ROOF, R-8 PROTECTION REQUIRED W
P THICK) ITUFTITE BOX] V)>�
INSTALL 7U TE BOX MINIMUM.(2' EXTEND Ld cr 0 0 0
ON STONE FRID.TO PROMOTE RIGID INSULATION 12"BEYOND )_
DRAINAGE AWAY FROM COMPRESSOR. TANK ON ALL SIDES =) 0 Of w
AIR COMPRESSOR INSULATED UD TYP. M
L'J U) LLJ
24'x 18*x S'THICK STONE PAD INSTALL THE FUSION MATH TUFTITE BOX PLACED
ONE 6-INCH RISER TO BRING ON STONE PAD, Z >_
E DS TO GRADE TYP. PROMOTE DRAINAGE AWAY LJ Of
0'
P
FROM COMPRESSOR. DO NOT <LLJ Of < V� C)
1 :3 ::) 0 _j
APPLY TWO BEADS OF SIUCONE SEALANT OR INSTALL UNDER DRIPLINE OF Cy Do < w
T ROOF.P
P,
ji 4STO.E
P 1
BUTYL SEALANT FULLY AROUND EACH RISER ROOF.
CLEANOUT SECTION PRIOR TO SECURING W7H SUPPUED <
SCREWS.TYP, AIR COMPRESSOR Li Z I,
OUTLET Z LLJ w
PATIO BLOCKS < Lij (f) U)
BUILDING I SUITABLE GRANULAR MATERIAL SHALL
SEVER UNE AIR UNES TO FUSION BE PLACED ON THE SIDES OF THE CAPILLARY AIR 4UNES LLJ
PANEL
FUSION TREATMENT UNIT FUSION UNIT TO BRING THE TO CONTROL PANEL <
SURROUNDING GROUND TO GRADE. STONE PAD LL 0
---- CONCRETE ANCHORING AS SHOWN WHEN Ln 0
MIN REQUIRED IN HIGH WATER TABLE AREAS. AIR.UNE—S TO FUSION. Z
NE'l, SEE FUSION OWNER'S MANUAL FOR MORE 1/2-0 SCD 40 PVC ¢ Ld Z
W
OR APPROVED EQUAL
FUSION VENTS THROUGH HOUSE VENT. INFORMATION.CONSULT SPECIFYING
I EXISTING VMT SYSTEM DOTS NOT0 Q
F HOUSE VENT IS NOT IN ENGINEER FOR REQUIREMENTS
Q_ MEET THE WLGNC CODE AND THE F-
-TANK EXCAVATION SHALL
FUSION MANUFATUIWS 4 12-18*LONGER AND
RECOWMENREQUIREMENTS.
I MA WDERIDTHAN TANK.
RATE RATION&REOU
SEPARATE VOTT MUST BE FUSION SHALL BE PLACED ON S"LAYER OF WASHED
BROKEN STONE(1/4-1/2*0)0 LEVELED TO FUSION 450 TANK FILE NUMBER
WITHIN 1/8-INCH SIDE TO SIDE AND END TO END. MEASURES 85t x 44'x 6ZH
EEM2021-022
FUSION 450 — TYPICAL PROFILE DATE
AIR COMPRESSOR INSTALLATION 2-11-2022
NTS FIGURE NO
NTS 3 ��
U
Jm
SPECIFlCATIONS: C
MEETS ASTM A-615
pp 51100 PSI CONCRETE MEETS N
MEETS ASTM C 478 tT
Z�7AFULFC0 QLS SERIES
* BODY: 104.2 LBS. [.06 TON] PDfrARR/CA TED LIFT SrarioiwS Wiry Z RAn fEcimmoay
PLASTIC BAFFLE *COVER:35 LBS. [.02 TON] P U Mf P COMPANY
*RISER:78 LBS.[.04 TON] C
RISER AVAILABLE Ty 0
18 .. Bain System
Type Du
ple. WLL
Diameter 36" Flhecylaaa '//J ,
CV --- _ Depth 48" 36"Diameter ` W—
TOP VIEW 3
O Dluharga standard 19"Dee i„ ;:'� Duplex Main 00
CcvK Blank-Fiberglass "'L �
COVER..: ..; Pumps&Controls
----, _ Solid Flergiau L
pump Famlty 2935ewage Pump /f Cover J„ N
', '• Pump Model 6293,23tlV,1PH Inlet: 1 Z to
ot
Cord Option No 1-Box,20'Cords 4'Pipe Seal
® . Panel standard Piva .. , ,L _- W M'
the Mode!E2931s o 1Np,130V,ZPk sewage pump,,
___._ _ _ D 4p o0
_s
� Discharge
1777777777777771.1 19" z
Pump Parformana
15' 13 aD — - — -- NOf
18 16" aD
r
-- — - ¢
SIDE VIEW END VIEW 46 0 O
3D _._ __— __ _.. 4 aasin Depth Lil la— DO
BOX ON 12"MIN. LIFT OF SAND 7YP - O DO
to
sD .._ zz >_ Y J
._ ....,,
6 OUTLET BAFFLED CONCRETE D—BOX °o— 2D b a� 100 12D M f �'' _ o Q
Ofcr
o
NTS Flow(GPM) ....._...._.. '_ ? U
W
Daslyn Point.Optional w Cn I = LLj
toalmnnww.,u?„n nm In vwl Zoeller ULS Series Package Description Yz 1— z
Flout(GPM) 10 GPM C.)W >—
Q
TOM(Ft) 35' Thlscompiete Zoeller Packets includes two Zoeller Model E203 ¢z (_) J U
Stalk Held(n) wwa9a pumps,Z•RWI dhconnacts with galvanized nib,l"sch. 0 m ¢ J W
80 PVC discharge piping with shutoff and check valves,duplex U) :5i ¢ J
AS6"Saaln has 4,41 Ballomn per Inch of Depth Plvot control panel,and three float switches with detachable Z W — L� W
float tree All pump and float cards are 20'long, ¢ LeJ U) W
J z
¢ J
z ({n O
DUPLEX EFFLUENT PUMP EJECTOR BASIN z z w
NTS O
I—
* 'n
r.y FILE NUMBER
EEM2021-022
DATE
2-11-2022
FIGURE N0.
4
0
_j U)
22'
--------........................... ------ TOP VIEW SIDE VIEW END VIEW
c:
ENMRO-SEPTIC PIPE 90'
20' ENVIRO-SEPTIC PIPE-
ELBOW
LEVEL.
-----------
ELBOW
PVC PIPE OFFSET ADAPTER Z
DO
OFFSET ADAPTER
DO-bW INSERT PVC PIPE
02-M INSERT PVC PIPE MOM THAN e INTO OFFSET fv
MORE THAN IV INTO OFFSET ADAPTER
ADAPTER r&.
RAISED CONNECTION DETAIL w
z co
.......... (0
NTS
_�
Lo
Z Lo
SEWN SEAM w M.
MANSE PLASTIC FIBER -PERFORATIONS
SOMMERS 0
_4 FOOTPRINT OF SYSTEM SAND-/ 00 Z
TYP. SEE SPECS. 0 LL�j- - - - ( 2"
cV
0
>- U- 0
ui o 00
EXTERIOR RIDGES z 3:
ui bi
CORRUGATED PLASTIC PIPE DETAIL Ld z >
........ 0 z —
---------- 0 o
'r-
Lli 0
tE_= !I
USE ADVANCED ENVIRO-SEPTIC (AES) M :D 3. LLJ
Ld V) lu 0
BY PRESBY ENVIRONMENTAL, INC. FOR YZ Z
THE DRAINFIELD. AES IS A LARGE ENVIRO—SEPTIC CORRUGATED PIPE OUJ >_ x
HIGH VENT <uJ < U5
DIAMETER PERFORATED, MULTI-LAYER SEE DETAIL TYP. NTS =D 0 _j
m < _j w
Ul :2 <
FABRIC-WRAPPED 12"0 PIPE. SEE ui Z u-
SPECS AND DETAILS. 6 OUTLET z w w
CONCRETE D-BOX SITE PREPARATION < uj C'4 U) U)
-i :D z
0 w
• MAINTAIN THE EXISTING CHARACTERISTICS OF THE UNDERLYING SOIL AS MUCH AS POSSIBLE. < -i
I- Ll- CD
0
• ADD THE SAND FILL ON THE SAME DAY THAT THE LEACH AREA IS EXCAVATED. Ln
C�4-NL':j' I=< z LLI z
PRESBY AES GSF BED PLAN INSTALL INITIAL 6" OF LEACHING SAND, THEN SCARIFY INTO THE UNDERLYING SOIL 8
WITH TEETH OF BUCKET TO ACHIEVE AN UNDEFINED EDGE BETWEEN THE SOILS. 0
INTS
DO NOT ALLOW WATER TO RUN INTO OR OVER THE SYSTEM DURING CONSTRUCTION.
• DO NOT WORK WET OR FROZEN SOILS. FILE NUMBER
EEM2021-022
DO NOT SMEAR OR COMPACT SOILS WHILE PREPARING SITE. DATE
"f-E S 2-11-2a22
NOTE: IT IS NOT NECESSARY FOR THE LEACH AREA TO BE SMOOTH WHEN THE SITE IS PREPARED. FIGURE No.
n U
VENTING REQ'DH-20 Y
X
FOR ALL H-20SCREQIVENT—SYSTEMS 36' EXTEND FABRIC 3' MIN BEYOND aENINGSBANK RUN GRAVEL EDGE OF PIPE(ALL EDGES) N(NO STONES OVER 2"0) PAVEMENT C
12" MIN (BELOW PAVEMENT) DISGUISE VENT IN TREE
VENT MAINIFOLD ," � �
(IF REQ'D) _
6" SYSTEM SAND z am 0
BOTTOM DRAINS RECOMMENDED �_
WHEN E-S PIPE ENDS ARE O
INACCESSIBLE INSTALL STABILIZATION FABRIC WITH A FlNQ GRADE
SYSTEM SAND 6" MIN ABOVE AND BELOW E-S PIPE. "GRAB TENSILE STRENGTH OF 315 LBS I.I
NO SAND VOIDS ALLOWED. WALK BETWEEN ROWS PER ASTM D 4632" SIX INCHES OVER w
(COMPRESSING SAND) TO ENSURE SAND FILLS ALL ENVIRO-SEPTIC PIPE `Q W
VOIDS AROUND E-S PIPES. -ENVIRO-SEPTIC
PIPE pPE. to
......... OD
NOTE ALL ROWS NOT SHOWN DISMBUIICN Box (—(�4
THE ONLY SOIL COMPACTION THAT SHOULD TAKE PLACE ENVIRO—SEPTIC DETAIL FOR H-20 PUCE WASHED STORE V�
IS AT THE POINT OF PREPARATION FOR PAVEMENT. WHEEL LOADING AROUND ELBOW o
N
(DO NOT SCALE) Z
H-20 WHEEL LOADING DETAIL HIGH GROIN/WATER TABLE
DRILL SEVERAL 1/4'f HOLES AT IOW w...i
POINT OF ELBOW TO DRAIN CONDENSATION.
NTS LOW POINT MUST BE ABOVE SEASONAL
HIGH WATER TABLE It
00 Z
REMOTE VENTING DETAILuj
G_
FINISHED CONCRETE, NTS Y Q
0_
GRAVEL OR ASPHALT
O
INSTALL STABILIZATION FABRIC WITH A "GRAB W>- I.I_ �
TENSILE STRENGTH OF 315 LBS PER ASTM D O O N
4632" SIX INCHES OVER ENVIRO-SEPTIC PIPE Z W >- W
BANK RUN GRAVEL L'J z I- > J
(NO STONES OVER 2"0) Z 0
12" MIN (BELOW PAVEMENT) W>- z 0 0 O
Lij
W U) I< LLJ
Z
Z
>- W'
Ls 2' 3' �� m4J W
- � Q J
4' 4' 4' 4' ' Z w L` w
q LL1 N U)
SYSTEM SAND 6" MIN ABOVE AND BELOW E—S-- ENVIRO SEPTIC J Orw
4
PIPE. NO SAND VOIDS ALLOWED. WALK BETWEEN LATERALS 12"0 N LL —i
ROWS (COMPRESSING SAND) TO ENSURE SAND N_ O
FILLS ALL VOIDS AROUND E-S PIPES. _
NOTE: zL'i z w
`t hJr'1 Y THE ONLY SOIL COMPACTION THAT
SHOULD TAKE PLACE IS AT THE O a
¢' POINT OF PREPARATION FOR
PAVEMENT. o
• s FILE NUMBER
F, TYP. PRESBY AES GSF TRENCH CROSS SECTION EEM2021-022
DATE
NTS 2-11-2022
FIGURE NO.
6
U
SYSTEM SPECIFICATIONS J
INSTALL A DUPLEX EFFLUENT PUMP EJECTOR BASIN MEASURING 36" IN DISPERSAL FIELD c
DIAMETER BY 48" TALL AT THE LOCATION SHOWN ON FIGURE 2. INSTALL 0)
ZOELLER MODEL E293 NON-AUTOMATIC, 230 VOLT, SINGLE PHASE PUMPS. DESIGN CRITERIA: THE MINIMUM TRENCH LENGTH CALCULATION FOR A 220 c:
PUMP CONTROL SHALL BE ZOELLER MODEL 10-1044 DEMAND DOSE PANEL. GALLON PER DAY DESIGN FLOW USING AN IN-SITU SOIL PERCOLATION RATE
PUMPS WILL ALTERNATE BETWEEN CYCLES. OF 1-5 MINUTES PER INCH REQUIRES A MINIMUM OF 42 LINEAR FEET OF 0 z y
TRENCH, AS SHOWN ON TABLE B - TRENCH CONFIGURATION GRAVELLESS o
USE 1 1/4"DIAMETER PRESSURE RATED PIPE CONFORMING WITH ASTM GEOTEXTILE SAND FILTER PAGE 6 OF THE DESIGN MANUAL
D-2241 CLASS 200 FOR FORCE MAIN. ALL PRESSURE JOINTS SHALL BE ENTITLED `DESIGN AND INSTALLATION MANUAL FOR ADVANCED TREATMENT W
PRIMED AND CHEMICALLY FUSED. FORCE MAIN SHALL TRANSITION FROM 1 LEACHFIELD AND ADVANCED ENVIRO-SEPTIC (AES) WASTEWATER
1/4 INCH DIAMETER TO 4 INCH DIAMETER PIPING A MINIMUM OF 8 FEET SYSTEMS",DATED MARCH 2O20. THIS DESIGN USES 60 LINEAR FEET OF W
FROM THE FUSION INLET. THE LAST 8 FEET SECTION OF THE FORCE MAIN TRENCH. z m
SHALL SLOPE TOWARDS THE FUSION (1/4 INCH PER FOOT). (�
FUSION SHALL BE INSTALLED AT THE LOCATION SHOWN ON FIGURE 2 IN N
z
ACCORDANCE WITH MANUFACTURES WRITTEN INSTALLATION INSTRUCTIONS
FOUND IN GLARUS DOCUMENT CL0056, DATED 2020. TREATMENT TANK ows
SHALL BE PLACED ON 6" LAYER OF WASHED BROKEN
STONE (1/4 - 1/2 INCH DIAMETER) LEVELED TO WITHIN 1/8-INCH SIDE TO
SIDE AND END TO END. TANK EXCAVATION SHALL EXTEND 12-18" LONGER 000 z
AND WIDER THAN TANK. FUSION 450 TANK MEASURES 85'L X 44"W N
X 62'H. SUITABLE GRANULAR MATERIAL SHALL BE USED TO BACKFILL THE
FUSION. INSTALL THE FUSION WITH A MINIMUM OF 6 INCHES OF COVER o � (n
OVER THE TOP OF THE TANK. o Z
0� o N O
INSTALL ONE DEDICATED 115 VOLT, 20 AMP ISOLATED ELECTRIC CIRCUIT w w >- Li
FROM THE MAIN ELECTRICAL SERVICE TO FUSION PANEL, WIRE AIR o z Z > Y Q
COMPRESSOR DIRECTLY INTO FUSION PANEL. of W>=0cr 000 _V
FUSION EFFLUENT SHALL BE PIPED THROUGH A 4" DIAMETER =) U L.L
SCHEDULE 40 PVC WITH SOLVENT-WELDED JOINTS, LAID AT MINIMUM GRADE w m I = w (�
OF 1/8 INCH PER FOOT TO A 6-OUTLET DISTRIBUTION BOX. DISTRIBUTION Yw > z W
BOX SHALL BE SET ON A MINIMUM 12" BED OF SAND. THE ELEVATION OF Uq w <t V
THE BOTTOM OF THE BOX SHALL BE AS NEEDED TO PROMOTE GRAVITY m m q J U)
DISTRIBUTION TO THE LATERALS. INSTALL SPEED LEVELERS ON THE INVERT w z :2 <
DISTRIBUTION PIPING. Q ui w N w
Or LzILL
I—
v~i o
W
z
'r a ;u,p• g
n' FILE NUMBER
EEM2021-022
DATE
2-11-2022
FIGURE .
7N0
U
GENERAL CONSTRUCTION NOTES '
ALL ELECTRICAL WORK SHALL BE COMPLETED BY A QUALIFIED ALL SYSTEM COMPONENTS SHALL BE INSTALLED, OPERATED, AND
ELECTRICIAN IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE, STATE MAINTAINED IN ACCORDANCE WITH EQUIPMENT MANUFACTURES �
CODE, AND LOCAL CODES. RECOMMENDATIONS, DESIGN DRAWINGS, AND ALL STATE AND LOCAL 0
REGULATIONS.
NO ROOF DRAINS, FOOTING DRAINS, OR WATER SOFTENING BACKWASH o
SHALL BE CONNECTED TO THE SYSTEM. CONSTRUCTION SHALL BE UNDER THE SUPERVISION OF THE
PROFESSIONAL ENGINEER CERTIFYING THAT THE SYSTEM WAS W
ANY CURTAIN DRAINS MUST BE 15 FEET FROM THE DISPERSAL FIELD. INSTALLED IN SUBSTANTIAL ACCORDANCE WITH THE APPROVED W T
DOCUMENTS.
LANDSCAPE - INSTALLER SHALL, TO THE EXTENT PRACTICAL, LIMIT z 0000
DISTURBANCE TO THE EXISTING VEGETATION INCLUDING MATURE TREES. NO GUARANTEE AS TO THE FUNCTIONALITY OR LIFE EXPECTANCY OF CO
SOME TREE REMOVAL MAY BE NECESSARY HOWEVER, NO TREES SHALL BE THE OWTS IS WARRANTED OR IMPLIED BY THE ENGINEER. UI N
REMOVED WITHOUT THE OWNER'S EXPLICIT CONSENT. ALL AREAS
DISTURBED BY THIS CONSTRUCTION SHALL BE COVERED WITH A MINIMUM THIS SEPTIC SYSTEM IS DESIGNED FOR USE WITH BIODEGRADABLE Z
OF 4-INCHES OF TOPSOIL AND PROPERLY SEEDED TO GRASS AND PRODUCTS ONLY. USE OF ANY OTHER PRODUCTS MAY CAUSE ows
MULCHED, PREMATURE FAILURE.
SETTLING OF FINISHED LANDSCAPING IS LIKELY TO OCCUR AND MAY CORRECTING MATERIAL/PRODUCT DEFICIENCIES IS THE
REQUIRE REGRADING IN A YEAR. RESPONSIBILITY OF THE MANUFACTURE/SUPPLIER. WORKMANSHIP IS w
LLJ
THE RESPONSIBILITY OF THE INSTALLER. THE UNDERSIGNED 0
SILT FENCE AND STRAW BALES SHALL BE INSTALLED AS NEEDED TO ENGINEER DOES NOT GUARANTEE OR WARRANTEE EITHER OF THE 4
PREVENT SOIL FROM WASHING AWAY FROM THE WORK AREA. ABOVE. O o z
W r 1- 00
THE CONTRACTOR SHALL CALL DIG SAFELY NEW YORK THE ENTIRE WASTEWATER TREATMENT SYSTEM INCLUDING TANKS, v>. O N Z
(1-800-962-7962) AND HAVE THE PROPERTY OWNER LOCATE ANY PIPING, RISERS, COMPONENTS, AND LIDS SHALL BE INSTALLED wZ j O
ON-SITE UTILITIES PRIOR TO INITIATION OF ANY CONSTRUCTION WATER-TIGHT. THE SYSTEM MAY BE TESTED FOR WATER TIGHTNESS. z y F-
ACTIVITIES. ANY UNDERGROUND ELECTRICAL UTILITIES IN THE VICINITY OF CONTRACTOR WILL RE-INSTALL ANY EQUIPMENT/COMPONENT THAT IS w cr p O V
THE OWTS DISPERSAL FIELD SHALL BE RELOCATED AS NEEDED AT THE NOT FOUND TO BE WATER TIGHT. TANKS SHALL BE INSTALLED AS O O D
DISCRETION OF THE OWTS INSTALLER. NEEDED (TO BE DETERMINED BY THE INSTALLER) TO RESIST w m 1 = w
BUOYANCY. Y z z �-
MAINTENANCE SHALL BE PERFORMED BY ONSITE EQUIPMENT, INC. IN U w Of
Of ¢ (n
ACCORDANCE WITH THE EQUIPMENT MANUFACTURES RECOMMENDATIONS SPECIFIED EQUIPMENT AND MATERIALS MAY BE REPLACED WITH z z U _j Z
OUTLINED IN THE HOMEOWNER'S MANUAL (CLARUS DOCUMENT CL0056, ENGINEER-APPROVED EQUIVALENT EQUIPMENT OR MATERIALS. c3 m ¢ O
DATED 2020). ONSITE EQUIPMENT, INC. HAS BEEN TRAINED TO PERFORM PROPOSALS FOR PRODUCTS SEEKING APPROVED-EQUAL STATUS Z z u- (�
INSTALLATION, OPERATION & MAINTENANCE BY THE EQUIPMENT SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. Q w (N V) J
MANUFACTURE AND IS AN AUTHORIZED SERVICE PROVIDER. a w
THESE PLANS HAVE BEEN PREPARED FOR THE USE BY THE Q
CURRENT PROPERTY OWNER. UNAUTHORIZED ALTERATION OR z cn O U.1
`F_raen ADDITION OF THESE PLANS IS A VIOLATION OF THE NEW YORK Q z Z
STATE EDUCATION LAW ARTICLE 145, SECTION 7209. wtn
.1 FILE NUMBER
EEM2021-022
DATE
2-11-2022
FIGURE N0.
8