98-122 CER ]PIFICATE OF COMPLIANCE
TOWN OF QUEENSBURY
WARREN COUNTY . NEW YORK
Da to may y 19 98
� 5 9 22
This is to certify that work requested to be done as shown by Permit No ,
has been completed .
This structure may be used as a DECK
Location 67 PEACHTREE LANE _
Owner ROOT R JAMES
TAX MAP NC3 . 12 f . - 15 - 73 By Order of Town Board
TOWN OF QUEENS URY
Director of Building & Code Enforcement
BUILDING PERMIT
VALUE $ 950 TOWN OF QUEEN5BURY No 98122
TAX MAP NO . 121 . — 15 - 73 WARREN COUNTY, NEW YORK
PERM IS+[ON is hereby granted to ROOT r JFiMES
OWNER of property located at 67 PEACHTREE LANE Street, Road! or Ave.
in the Town of +Oueensbury,
To Construct of place a DECK
at the above location in accordanoe to application together with plot plans and other information hereto filed and
approved and in compliance with the Town of Queensbury Building and Zoning Ordinance.
1. O VVN E FM Address is
67 PEACHTREE LANE
QQUEENSBURYr NY 12804
2. CONTRACTOR or GUILDERS Nang
ROOTr JAMES
3. CONTRACTOR or SUILDER*5 Address
4. ARCHITECT'S Name
5. ARCHITECT'S Address
6. TYPE of Construction — (Please indicate by Xi DECK
rPLANS
wood Frame I I Masonry ( f Steel I l
Sp*clfirstions
Q ET DECK AS PER PLOT PLAN SPEiCIFICATIONS
e
16 Apr i 1 13 2000
$ PERMIT FEE PAID — THIS PERMIT EXPIRES . 19
(if t lownger Ipwiod Oueen:s rvquW*d on
before the eplic ration date Ixtanason must be made to the gulliding and Zoning itoWactor of the
13 Apr11 19
Gated at the Town of Queensbury it is
Day of 19
for the Town of Queensbury
SIGNED BY
i rq and zoning l
TOWN OF QUEERSBURY Fee Paid hQ .
BUILDING & CODES DEPARTMENT
APPLICATION FOR : PORCHES- DECKS- Permit # C �' ��
(a DOCKS & BOATHOUSES 'Est . Cost ' C () `�,' 10
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION , PLEASE ANSWER ALL OF THE FOLLOWING :
The undersigned hereby applies for a Building Permit to do the following work which will be
done in accordance with the description , plans and specifications submitted , and such special
conditions as may be indicated on the permit . TWO SETS OF STRUCTURAL PLANS SHALL BE SUBMITTED
WITH THIS APPLICATION .
Owner of Property : --/& rulFs %. Pra+ _
P . O . Address _ 67 PP'AC41F � L L� 'A)F. . QuEFZ- t cf uklf b 1 �..F�?'i_ Phone # , 7n - ' -73
Property Location [ a �Q Tax Map #
Subdivision Name ( If applicable )
PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES :
Name : TlaszL Address � �x , �, Phone# 7� -
BUILDING SPECIFICATIONS :
Type of work to be done : Porch Deck Dock Boathouse ( G 4 r G 1 e rr -
Size of Structure to be built ( square footage ) : " D
Foundation Material : Width � k,
�:, �' `� C �,' v
Thickness ApR 07 19%
Depth of Footing , below grade : L4 c,, gRy
Sizeov-
of Posts or Studs : � ' x 1 ' x ,,� Long T �"
Size of Floor ,Joists : Y " f -~
�" x� x � { � Span
Decking or Flooring Material
How will
ill Porch or Deck be fastened to building ? (01,5r f, Z,(& " x
c IN f 1'1 E1' 'k L l '4- +o "_f o V p {•-
If Roof Will Be Installed'-,'
nstalled Answer Following Questions :
Size of Posts or Studs : _ x x Long
Roof Rafters : x Spacing Span
Roof Trusses ( pre-engineered spacing ) : Span
Type of Roof : Sloped Flat Shed Other ( Circle one )
Material of Roof :
ZONING INFORMATION :
TWO PLOT PLANS MUST BE PREPARED AND SUBMITTED , drawn reasonably to scale and attached
hereto , showing clearly and distinctly all buildings , whether existing or proposed and
indicate all set back dimensions from property lines . Show location of water supply and
location and configuration of septic disposal area .
Size of Property : ft . x ! ; ft .
Existing building ( s ) : Size �y ft . x _ ft
� .
Size u ft . x c� ft .
Use of Existing building ( s ) :
-;2�'x �� f%z�{2.
Proposed structure , distance from property Tine : '
Front yard 0 ft . Rear yard __33 fte
Side yards I ft . and S ft .
If on corner , setback from side street : ft .
DECLARATION
To the best of my knowledge and belief the statements contained in this application ,
together with the plans and specifications submitted , are a true and complete statement
of all proposed work to be done on the described premises and that all provisions of the
Building Code , the Zoning Ordinance , and all other laws pertaining to the proposed work
shall be complied with , whether specified or not , and that such work is authorized by the
owner .
DATE : t I-7/ SIGNATURE yr
y - L"
n , Owner s Agen , Contractor
REVIEWED BY CODE ENFORCEMENT OFFICER , DATE / SIGNATURE
RESIDENTIAL FINAL INSPECTION REPORT
Office No.�(518) 761-5256 Date inspection request received, ��
Building Cc Code Enforcement t j�
Dept. of Community Development Arrive amlprn Dep - i!
Town of Queensbury Inspector's Initials
742 Bay Road
Queensbury, New York 12864 /'y I� r-,
NAME PERMIT #
LOCATION DATE
TYPE OF STRUCTURE �
NIA YES NO COMMENTS
Chimney HeigbtrWl Ven ect Vent Location
Fresh Air Intake
Plum Vent through roof
Root omplete
Exterior Finish Complete
Interi fExte - Railings 3D" t 36"
Exteri handrails, balconies, ding 18 in. or more _--
Interior drails stairs both s" s 3 or more risers
Crsade 2° away from foundati n
8" elearan to sill plate
Gas Valve ut-off exposed/r gulator 18" above grade
Gas Furnace s ut-off within feet or within line of site.
Oil Furnace sbutroff at entrailce to furnace area
Furnace/Hot Watt Heater o0crating
Relief Valve(s) ins led
Headroom, b ft. 6 in. staff .
Basement stairs, 6 ft. 4
Handrail exterior stairs bo sides more than 3 risers
Interior privacy/trim/doors/ entrance 36"
Floor Finish
Bathroom/Kitchen waterti t
Interior Haurdrails Balcom s/L.andmg 8 in. or more
Railing across window in tairwells
Smoke Detectors:
every level
every bedroom
outside every bedroom
inter connected
Bathroom. fans
Plumbing fixtures
Foundation insulation
3f4 hour fire door/door cl r
Garage fireproofing
Garage penetrations sealed
h'umace m separate room protected fin garage)
Light ventilation per room
Safety glazing 181, or less from floor
Final Electrical
Site Plan/Variance required
Final Survey Plot Plan
As Built Septic system layout required
Okav to issue C/C (Certif. of Compliance)
Okay to issue temp- C/o (Certif of occupancy)
Okav to issue permanent CIO (Certif. of Occupancy)
GENERAL INSPECTION REPORT
Town of Queensbury
Dept. or Community Development Date inspection request received:
Building ,& Code Enforcement �-
742 Bay Road
Queensbury, NY 12$04 ArriV/r am/pm Depart
Inspector's initials`
NAME: C� PERMIT #
LOCATION: god DATE : L-} t;k.!A -R�
TYPE OF S CTURE:
RECHECK
NIA YES NO COMMENTS
Footings/Piers f
Monolithic Po Form,
Reinforcement i Place
The contractor Bible fo
providing protecti from freez'
for 48 hours fo wi the place ent
of the concre
Materials for is purpose on site
Foundati allpour
Reinf6rcement in Place
Foundation/Dampproofing
Backtzll Approval
Plumbing Linder Slab
Plumbing Vent/Vents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
WaIls R-
Ceiling R-
Duct work or piping in
eatcd spaces R-
Pr r Ve Attic Vent
raming
Jack Studs/Headers
Bracing/Bridgin
Joist Hangers
.lack Posts/Main Beam
Air Infiltration Barrier_
Fire Separation 1 , 2, 3, hour
Penetration Sealed
Fire Wall 2, 3 , 4 hour
Firestopping
GENERAL INSPECTION REPORT
Town of Queensbury
Dept. of Community Development Date inspection request received:
Building & +Code Enforcement
742 Bay Road / .
Queensbury, IVY 12804 Arrive! C7` rnlpm Depart/ a�n/ -
Inspector's Initials
NAME: .,� ~ [�t�. PERMIT # ..
LOCATION: -'"" -' TE ;
TYPE OF STRUCTURE:
RECHECK
NIA YES NO COMMENTS
FootingslPiers I
Monolithic Pour Form
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours fol wing acement
of the concrete.
Materials for this p se on ite
FoundationJWallpo
Reinforcement in I
Foundation/Da roofing
Bacicfill Appr 1
Plumbing U der Slab
Plumbing ent/Vents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R- �^
Walls R_ A) !, l L ,, <-e F-A ►"1
Ceiling R-
Duct work or piping in T
unheated spaces R- � L3L �4 �C 1 vec4t<J
Proper V �, , Attic Vent
Jack Studs/Headers
Bracing/Bridging,
.foist Hangers
Jack Posts Main Beam
Air Infiltration Barrier_
Fire Separation 1 , 2. 3, hour
Penetration Sealed
Fire Wail 2. 3, 4 hour
Firestoppin g
GENERAL INSPECTIf)N REPORT
Town of Queensbury
Dept. of Community Development Date inspection request received:
Building & Code Enforcement
742 Bay Road
Queensbury, NY 12804 Arrive W
pm Depat 11,
Inspector°s Initiials
M
--�
NAE: PERMIT # C "
LOCATION! DATE
TYPE OF STRUCTURE:
RECHECK
NIA NO COMMENT
\--�gs/Piers I
Monolithic Pour Form
Reinforcement in Place
The Contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site
Foundation/Wallpour
Reinforcement in Place
Foundation/Da mpproofi n
Backfxll Approval
Plumbing Under Slab
Plumbing VentrVents in Place
Rough Plumbing
Heating Rough-In
Insulation
Foundation Walls Interior R-
Foundation Walls Exterior R-
Floors R-
Walls R-
Ceiling R-
Duct work or piping in
unheated spaces R-
Proper Vent, Attie Vent r
Framing
.tack Studs/Headers
Bracing/Bridging
Joist Hangers
Jack Posts/Main Beam
Air Infiltration Barrier_
Fire Separation 1 . 2, 3. hour
Penetration Sealed
Fire Wall 2. 3, 4 hour
Firestopping
TOWN OF QUEENSBURY BUILDING DEPARTMENT FILE COPY
W4 on our arnmmourc gemination, 1 DI x �0 ' PRESUF MA ED DECK
cam�'�ance with our cammentasha1
rat he mdrued as Wb*tte BY JIM ROOT, 67 PEACHTREE LANE, 11EEOSEERY, NY 12904
plans end vwfatima are in td
comoisnce witty the code
r x a' JESTS Is' D.c
SPETKATIaNs
SIIOINO GLASS FRS Y x 8' LEDGER
1, ALL WE TO OP PRESSIRE TREATED. ID1SE
2. ALL FASTENS TO BE GAL0NI7FO 0R 711UPLATEO FOR EXTERIOR IISE. 4' x 6' PRfMILM
3, FOONG TO 8E 8' DIA, CD ff11 PILLARS 4B' BELOW GRADE e 5' 0.[ 1 DECKING
67 112 [0
4. LEDGER TO BE 2' x 8' AND LAG SR WED TO NI 9 HE AIR
9G
5. GIRDER BEAM 10 OF 4' x 8', SPLICED AT SEAMS, AND ATIkHF9 TO FOETINGS.
l�O
5. JOISTS TO BE 2' x 8' a 3]' O.C. —
7. RING TO BE PREMIIM 5/4' x 5' RAOIL>S FILED. 2' x 12' TREAD
8. RAILINGS TO EXIST OF 4' x 4' POSTS, 2' x 4' VENEERS, 2' x 6' TOP CAP, — —
ANO 2' x 2' [OLOINIAL SPINOLFS a 5' D.[.
9. STAIRS TO HAVE 2' x 12' TREADS, 2' x 8' STRINGERS, 4B' WICE, WITH MAX. 7.5' RISE, 59 I� 59 112 ---wm1 591 59112
d' x B' 01R€PR BEAM
12 72 72 �
2' x 2' (OLONIIL SPINDLES 6' O.[.
2' x 6' TOP CAP
4' x 4' RAIL POSTS
36
POST kla GRADE
B' BIA
PILLAk
� TIiFt �; ° 4 fit°
nty
F k�) Lil4 Y f
f'Evj[-wCD E
DATE f 3
SITE PLAN
57 PEACHTREE LANE, DUEENSOURY, NY 12804
t
LEACHFIELO
79' -
i
[221 �
3' - 3 112"
IO' x 20' 1PROPOSED DECK62" x 92" SEPTIC TANK20 - D T 10' - 4 120
t
78 57 8
100' - 4112"
+ I t l00' - 4 1120
HOUSE 2-1AR GARAGE 20, - 0"
24' 0"
r ,
r ,
60' - 4" 20' - 0"
TOWN WATER l
SUPPLY IN
34, - 6 12"
r ,
DRIVEWAY
PEACHTREE CANE
125' - 1a,