1999-610 BUILDING PERMIT Town of Queensbury, 742 Bay Road, Queensbury,NY 12804 County of Warren (518) 761-8256 VALUE $ 4 500 Building Permit No. 9 9 610 TAX MAP NO. 101 . -1-6 Permission is hereby granted to WHITING, ROGER, JR. & Owner of property located at 6 DIXON COURT in the Town of Queensbury,to construct or place a ?-CAR ATTACHED GARAGE at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Owner's Address: PAMELA 6 DIXON COURT QUEENSBURY, NY 12804 Contractor or Builder's Name: - WHITING, ROGER Contractor or Builder's Address: 6 DIXON COURT QUEENSBURY, NY 12804 Electrical Inspection Agency: Type of Construction: 2-CAR GARAGE • Plans and Specifications: 2-CAR ATTACHED GARAGE AS PER. PLOT PLAN SPECIFICATIONS Area Variance No. 50-1997 approved 9/24/97 Proposed Use: 2-CAR ATTACHED GARAGE $ 35 PERMIT FEE PAID-THIS PERMIT EXPIRES November 29 2001 . (If a longer period is required,an application for an extension must be made to the Code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the . . o Qu-enssb- . 29 Day of November 1999 SIGNE •Y ,/ `� )i • -:e- ownof eensbury a_, nforce is ' Offic- ,,,,, , , Building Pe Application - . Town of Queensbury - Dept. of Conununity Development, 742 Bay Road, Queensbury, NY 12804 [761-8256J BUILDING & . COD,E ENFORCEMENT. r • NOTICE Requirements prior to issuance r A permit must be obtained before of this permit: PERMIT FILE.NO. PEE1.10___ beginning construction. No inspections Oo. will be made until applicant has received [ Zoning Board Action . PERMIT FEE PAID$ • a.VALID BUILDING PERMIT. All - 0 /Use` sb-la/f l RECREATION'FEE ' !. $ applicants' spaces on this application MUST be completed attd•the signature 0 Planning Board Action REVIEWED BY ,Ai, of the applicant•must a• ppear on the SPR / Subdivision /Other �` ,!:uitding Inspector application form..Thank pa : J. Recreation Fee Payment 'Applicant:(er ,�Pcurie_Jq' .0h.) 1-1., Owner: ..5CU� . . . ' -Address: CP 4;:xon e+ eei,5bur9 ,+ Address; Phone # (5/g ) 7q8 .1-2iy ' Phone # ( ) - • . Property Location: • . .. ' Tax Map Number /Ol / 1 / �P Subdivision Name: — Section Block Tnt NATURE OF PROPOSED WORK: ESTIMATED MARKET VALUE OF THE. New Building: CONSTRUCTION: $ 1 ono residence / -commercial Addition to Building: residence / commercial OCCUPANCY INFORMATION: Alteration to Building: Primary Building eN . residence / commercial Single Famil , . � Residence / Commercial Two Family Dwelling no change. to exterior size •. • Family Dv . 1 1999 • Office - I/ Other Work (describe below.) Mercantile TOWN OF QUEENSBURY Uec.zduoce ,. v..6.t.eJJt_%. Manufacturi -a ILDING AND CODE Other GROSS AREA' OF PROPOSED 'STRUCTURE:. If ADDITION, what will use 1st Floor .5.-/(o. sq: ft. of new addition be? : 2nd .Floor • sq. ft. Other Floors . sq. ft. . (not unfinished cellar or• basement) • ACCESSO • RY BUILDINGS: Detached Garage 1, 2 car TOTAL FLOOR AREA.: 7(p SQ. FT. ti Attached Garage 1, ar - Private Storage Building SIZE OF NEW STRUCTURE: Commercial Storage Building Other • -.21f FEET X. 02 y FEET Foundation Type: Will any second-hand or ungraded ' Number of Stories : - lumber be- used? If so, for what? (habitable space only) ' . Height (grade to ridge) : feet TYPE OF HEATING SYSTEM: . - Number of fireplaces and/or woodstove (circle. all which applies) to be installed: • Electric / Oil • / .Gas / Wood • Forced Hot Air. / Baseboard / Other ' Person-.responsible for supervision, of work as regardss -to building codes is : . eager t�Jh!(llItlp- 6 ,D'xvr C., C eei2Sbtirip. ` 7/2-7314 - Name Addresss Phone Builder: Plumber: - . . Mason: . . Electrician: • DECLARATION: Please sign below after you have carefully read the statement. TO the best of my knowledge the statements contained in this application, together with the plans and specifications'submitted, are a true and complete statement,of all proposed work to be done on • the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and • that such work is authorized by the owner. Further,•it is understood that I/we shall submit prior to a Certificate of Occupancy'or'Certificate of Compliance being issued, an'AS BUILT PLOT PLAN by a licensed surveyor; drawn to scale, showing,actual-location of project on premises. Signature:• _�`r sept_ � �, �„� . . • • (owner, owner's agent, architect, contractor) 74, q.,, 61D ENERGY CODE COMPLIANCE PPLICATION TOWN. OF QUEENSBURY, WARREN COUNTY = 9000 HEATING DEGREE DAYS Compliance Methods: PART 5 - Acceptable Practice Method - • 1&2 Family Dwellings (only) PART 6* - Thermal Rating - Component Trade Offs 1&2 Family Dwellings; Multi-Family Dwellings (3 stories or less) PART 4* = Design by Component Performance Commercial Buildings-Hi Rise Residential *Requires submission of worksheets. APPLICANT' S NAME: PROPERTY LOCATION: --govx A ?•A 6* awn Ch, 414.eavabadr.q_ PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1 . Gross Floor Area - 57 (P . square feet 2 . TvDe of Heat - Electric Oil Gas Other 3 . Is building mechanically cooled? Yes No 4 . Percentage of area of windows and doors Over 17% Under 17% 5 . R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R-VALUES AS SHOWN ON PLANS SUBMITTED: a . Roof R b . Exterior walls R c . Glazed areas R d. Exterior doors R e . Floors over unheated spaces R _ . Edge of slab on grade (heated building) R g. Basement/cellar walls (above grade) R h . Basement/cellar walls (below grade) R i . Heating/cooling-ducts-piping in unheated space R 6 . Service (domestic) hot water heating device Conforms to minimum efficiency per code Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140° - WILL NOT BE EXCEEDED Aoolicant ' s Signature Date Phone Number . 2�Cnx P, 10-�, 9/tea/99 '71,-7am/ INSPECTOR' S REMARKS: • Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection re e t re ei d: Queensbury Building&Code Enforcement Arrive: epart: a p 742 Bay Road, Queensbury,NY 12804 Inspector's Initi s• NAME: \ C PERMIT#: LOCATION: n\`y-0A C-OV-Vg7 INSPECT ON: — TYPE OF STRUCTURE: Y N N/A COMMENTS • Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses VJ Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 'V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade • Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection reque eceiv Queensbury Building&Code Enforcement Arrive: a m rt: a 742 Bay Road,Queensbury,NY 12804 Inspector's Initi s NAME: RCS6E12-: l�1'��� PERMIT#: — LOCATION: V)P XL;,,% l_�U '�-T INSPECT ON: —0` TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents s a Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test • Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping • Copper Commercial �\�� Copper, CPVC,Pex One &Two Family \� f Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace \--/* Duct Work Sealed Properly • COMMENTS: • • • L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 --2____ &. , ,. i Framing / Firestopping Inspec *on Report 1 Office No. (518) 761-8256 Date Inspection req •st eceive• Queensbury Building&Code Enforcement Arrive: a pi D-a . �m��mm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial': `s IC— NAME: d b3i'arwl'\. PERMIT#: cri,-Co 0 LOCATION: Lk ACS -N, C--CrU INSPECT ON: g---;),(0-03 TYPE OF STRUCTURE: Ca- Qfl COMMENTS Jack Studs/Headers I / Bracing/Bridging Joist hangers Jack Posts/Main Beams / Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. 9-c)C Stairwells 36 in. or more Headroom 6 ft. 8 in. 6 Notches/Holes/Bearing Walls • `\ \G _ qe,...---- Metal Strapping for Notches Top Plate ,i?\L �► ,Q 1 Y2 (w) 16 gauge (8) 16D nails each side C ��/ �/`12 Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center "<\)\- Ice and snow shield 24 inches from wall \\ Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour f`�)irestoppingenetration sealed . 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X • Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection requ-- -cei -•: y./ Queensbury Building&Code Enforcement Arrive: . p • ►ep. i1.m 742 Bay Road, Queensbury,NY 12804 Inspector's Initi.ls• NAME: Rai 1)\-k\T\1C PERMIT#: 1°69-6 tO LOCATION: (c) n 1 51zt. INSPECT ON: "9-3--?, TYPE OF STRUCTURE: • N N/A COMMENTS Framing ._V--ROki) fk 1R 1 ` Jack Studs/Headers � — '6 PtVAS\1__-. Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade WILLIAM E. MONTGOMERY JR. PE NEW YORK STATE PROFESSIONAL ENGINEER 104 HARTMAN-LOOP QUEENSBURY,NEW YORK 12804 Phone: 518-792-4262 INDUSTRIAL August.5, 2003 Structural Renovation Pumps and Piping HVAC Roger Whiting Energy Compliance 6 Dixon Court. _ _- Queensbury,.New_York 12804- . COMERCIAL& RESIDENTIAL Building Codes Dear Roger Whiting, - Energy Codes Septic Design HVAC I inspected your garage this morning. One attic truss has had part of its bottom 2"x8" chord removed to allow a stairway to be installed to the storage area, overhead. The bottom chord has been headed off with a double 2"x8" member on each side of the stairwell opening. Each header was hung to the truss on each side of the stairwell. The attic truss in-line with the center of the stairwell was hung at each end to the headers. The garage has been through two (2) winters with no snow.load injury to it's roof assembly. These trusses were made by Curtis Lumber and have 2"x8" top and bottom chords and are installed 24" O,C. The existing trusses, stairwell and roofing are satisfactory as they-exist now. Although installed long before the new Residential Code took effect last January, the existing-roof assembly is entirely satisfactory: Let-me know if there are any questions. Please give a copy of this letter to the appropriate building inspector for his records. Sincerely yours,17 oe�pEESSiOp���yc�S�• 1AO N TOp 4. ys (//Z e-, op; r2 William E. Montgom Jr. PE " -' �o s 437419 447 /n4THE STA10s Framing / Firestopping Inspection Report 1 :0DA Office No. (518) 761-8256 Date Ins•ection re•uest received: QQueensbury Building& Code Enforcement Arrive, .= ••, • rY � D.•" " s>s.� y 742 Bay Road, Queensbury,NY 12804 Inspector's • -=. l#111r NAME: ll% PERMIT#: �J�f- &I L) LOCATION: 6 d) (j-- INSPECT ON: TYPE OF STRUCTURE: _1 610_ Y I COMMENTS Framing Jack Studs/Headers Bracing/Bridging \O P`�`�� �� Joist hangers i\ 5 f\w Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more _`Kpi Headroom 6 ft. 8 in. �C- (� - t* Notches/Holes/Bearing Walls I F—ist ---\) Metal Strapping for Notches Top Plate 1 %s (w) 16 gauge (8) 16D nails each side —Cle iV71 Draft stopping 1,000 sq. ft. floor trusses — �.VV T Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall U2)?.._-- Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping \--\- Penetration sealed -10iKFC_ 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 GENERAL INSPECTION REPORT ( 518 )761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: '4I ata lb I Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depa a m Inspector's Initials NAME: i. PERMIT# —1-to I r LOCATION: !40 at ,r- Ck DATE: Lev TYPE OF STRUCTURE: a ('cut caul( RECHECK N/A YES-NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is respo ble for providing protection fro freezing for 48 hours following th placemen of the concrete. Materials for this purpose o site Foundation/Wallpour Reinforcement in Place Foundation/Damp.roofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing tang Rough)In n i nsulation �r� 4-1./ Foundatior Walls Interior R Foundation Walls Exterior R / • - Floors R- I.� Walls R- S Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers / Bracing/Bridging , Joist Hangers Jack Posts/Main Beam Air Infiltration Bather Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping --- -.-G-Nk GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804 Arriv72, aipepartii r . eli iP Inspector's Lift'• NAME: OA l L- � PcNM t l l VNN PERMIT# Zt' — — (/ 0 LOCATION: c)1 Cr. n I P r DATE : Ca—ZZ.—0 J (\TYPE OF STRUCTURE: (WI; (-WING ___ RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in PlaceI Foundation/Dampproofing Backfill Approval / Plumbing Under Slab / Plumbing Vent/Vents in Place Rough Plumbing / Heating Rough-In i 1 Insulation N. i Foundation Walls Interior R-----' Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- J Proper Ven Attic Vent Framing ilt1N®�-e� I Jack Studs/Headers I Bracing/Bridging / Joist Hangers \\ o - 5 55 :' 'c\�F�. Jack Posts/Main Beam Air Infiltration Barrier )3 \ \C' c-,- 7 0,P Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping Cin GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Qucensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive b Pm Depart ' Inspector's Initi NAME: PERMIT# — 'cam LOCATION: C-DORT— DATE : 1 —Z_9 TYPE OF STRUCTURE: Pt-r-rACt-kE.n 7_ C_RR ACC RECHECK N/A YES NO COMMENTS Footings/Piers I I Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing fok 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place /Foundation/Dampproof ng VBackfll Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing �Heating Rough-In f IX - �o c✓tnsulation V-e-Eu� �r1e-Yt ec \ /4/ ADD �tV �v Ftko�� OF _iLt 2 FeRt-A Foundation Walls Interior R- 10 t/ J TC P� CO E�TEO t�TD Q F Foundation Walls Exterior R- 1-kERT FetAtt_� ecom �T�>�E- Floors R- Walls R- Cei l ing R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent_ Framing__ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam z1 —3 Ll Air Infiltration Barrier_ Fire Separation 1,2, 3, hour EQQL () 113" Penetration Sealed Fire Wall 2, 3,4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: 6G 0- J' v Building&Code Enforcement 742 Bay Road f; Queensbury,NY 12804 e ✓ j Depart Inspector's Initi NAME: OAT PERMIT#�C.--'7CQ/6 LOCATION: DQ?cDv. C� , DATE : gy�-e7n TYPE OF STRUCTURE: c� RECHECK N/A YES'NO COMMENTS °wigs/Piee o is Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour . Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive, am pm Depa :1pm Ins ctor's Initiate NAME: 0 VP. : CR 1. czy PERMIT# 9-CAI) LOCATION: `c) C r;%: DATE : ‘ -00 TYPE OF STRUCTURE: n E2 - RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing FPI \L__ Q.Jt�CM for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour 1�(�s`� - W Reinforcement in Place \ t �i±Ct Foundatio ampproofing ��� Backfill Approval .13L �-�C Q `� ‘Zl-` t�� Plumbing Under Slab Plumbing VenUVents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R • - Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- _ Duct work or piping in unheated spaces R- Proper Vent, Attic Vent_ Framing_ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam _ Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping _