Loading...
RC-0393-2021 Office Use Only 1 MANUFACTURED HOME Permit#: PERMIT APPLICATION Permit Fee:$ Town of Queensbury 742 Bay Road,Queensbury,NY 12804 e P:518-761-8256 www.gueensbury.net Rec Fee: $ Invoice#: 't)q_gx� Project Location: 78 Briwood Circle Flood Zone? Y 6 Reviewed By: Tax Map ID#: �� Name of Park (if applicable): Forest Park MHC, LLC E C E Q V E PROJECT INFORMATION: MAY 2 5 2021 1. Proposed Date of Placement: 08-01-2021 TOWN OF QUEENSBURY BUILDING A CODES 2. Approximate Value of Home:$ 50,000.00 3. Is the home NEW x or a REPLACEMENT ? 4. Single-wide or Double-wide Size: 16 ft.x 76 ft.- 1216 total square feet 5. Foundation support(choose one): Size Depth x Piers: 2411 48 11 Slab: 6. Is the home being placed on a private lot? No x Yes** (**if yes,you must provide stamped engineered drawings of the permanent foundation plan) 7. Total#of rooms(exclude bathrooms): 5 ;#of bedrooms: 3 ;#of bathrooms: 2 8. Additional heat source? No x Yes Choose one, if yes: gas fp_ woodstove_ wood fp 9. Are there any other/existing buildings on the property? No x Yes ; Explain: 10. What is the water source? PUBLIC x PRIVATE WELL 11. What type of wastewater system is on the parcel? SEWER PRIVATE SEPTIC x 12. Do you need a septic permit application? No x Yes MANUFACTURED HOME INFORMATION: (INFORMATION FOUND ON THE PLATE OR STICKER LOCATED IN THE HOME): Insignia serial#: TBD Name of Manufacturer: Campion -Topeka Place approval #: Model or component designation (New Home Only): D01680 RHPFK7616 Date of manufacture: Manufactured Home Application Revised January 2021 REQUIREMENTS FOR SUBMITTAL: 1. Completed Manufactured Home permit application THREE (3) COPIES OF THE FOLLOWING: 2. Structural drawings, which include: a. Floor plan b. Foundation plan (see 2015 IRC Appendix E Section AE502:foundation systems) c. If the home is being placed on a private parcel (not in a manufactured home park or designated zone),you MUST provide stamped engineered drawings of the permanent foundation plan. 3. Plot plan, using a survey map if possible, which includes: a. Drawn to scale (i.e. 1 inch = 30 feet) b. Indicate proposed location, with setbacks c. Include all.structures on the property d. Include location of water supply (well or water lines) e. Include location &configuration of septic system or sewer line ADDITIONAL SUBMITTAL INFORMATION: 1. Installer Warranty seal must be provided,prior to issuing Certificate of Occupancy. 2. Any changes to the approved plans prior to or during construction will require the submittal of amended plans, additional reviews and re-approval. 3. If, for any reason, the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. 4. Workers' Comp insurance information for all contractors involved—REQUIRED, EVEN FOR SOLE PROPRIETORS DECLARATION: I swear that,to the best of my knowledge and belief,the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises; and,that all provisions of the NYS Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or not, and that such work is authorized by the owner. I have read and agree to the above: PRINT NAME: A-Lk (C 4A SIGNATURE: DATE: I a, Manufactured Home Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Forest Park MHC, LLC Mailing Address, C/S/Z: 183 Pitcher Road Queensbury, NY 12804 Cell Phone:_( Land Line: ( 518 ) 745-7776 Email: forestpark@rhp.com • Primary Owner(s): Name(s): Forest Park MHC, LLC Mailing Address, C/S/Z: 183 Pitcher Road Queensbury, NY 12804 Cell Phone: ( Land Line: ( 518 ) 745-7776 Email: forestpark@rhp.com ❑ Check if all work will be performed by the property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Dan Hunt/ Hunt Home Services Contractor Trade: Site Prep/ Home Set Up Mailing Address, C/S/Z: 36 Brickoven Rd.'Queensbury, NY 12804 Cell Phone: ( 518 ) 361-2931 Land Line: � ) Email: dirtywhiteboy970@yahoo.com "Workers' Comp documentation must be submitted with this application" Contact Person for Compliance in regardsto this project: Jack Evans - Community Manager Cell Phone: ( ) Land Line: ( 518 ) 745-7776 Email: forestpark@rhp.com Manufactured Home Application Revised January 2021 NEW YORK'ATE OF Department S OPPORTUNITY- of Health ANDREW M. CUOMO HOWARD A. ZUCKER, M.D.,3.D. LISA 3. PINO, M.A.,J.D. Governor Commissioner Executive Deputy Commissioner June 11, 2021 Forest Park MHC, LLC LJ E (C 0 E Attn: Joel Brown JUN 2 2 2021 31200 Northwestern Hwy _ 0 Farmington Hills, MI 48334 TOWN OF QUEENS BURY BUILDING & C,'20 S RE: Forest Park Mobile Home Court ., Facility code: 56-6822 (T) Queensbury, Warren County Install mobile homes on Lots 9, 15, 16, 49, 58, 69, &7.8Bftop0-Circle; Lot 17 Gregwood Circle; Lot 12 Timber Lane; and Lot 31 Woodland Path Dear Joel Brown: We have this day, approved the plans for the above-referenced project. Application for this project was initially received on May 24, 2021, with additional information received June 9, 2021, and duly submitted by Jack Evans on form DOH-154 (Notice of Intent)that proposed to: • Replace an existing 3-bedroom, 14-foot x 66-foot mobile home on Lot 9 Briwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 14-foot x 70-foot mobile home on Lot 15 Briwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 14-foot x 70-foot mobile home on Lot 16 Briwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 16-foot x 76-foot mobile home on Lot 49 Briwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 16-foot x 66-foot mobile home on Lot 58 Briwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 14-foot x 66-foot mobile home on Lot 69 Briwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 14-foot x 66-foot mobile home on LotE78_Briwood-Circ elel with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 14-foot x 70-foot mobile home on Lot 17 Gregwood Circle with a 3-bedroom, 16-foot x 76-foot new mobile home. • Replace an existing 3-bedroom, 20-foot x 66-foot mobile home on Lot 12 Timber Lane with a 3-bedroom, 16-foot x 76-foot new mobile home. Glens Falls District Office,77 Mohican Street,Glens Falls,NY 12801,518-793-3893 1 gfdo@health.ny.gov • Replace an existing 3-bedroom, 24-foot x 66-foot mobile home on Lot 31 Woodland Path with a 3-bedroom, 16-foot x 76-foot new mobile home. The Department has no objection to the proposed action and the work may proceed conditioned on the following: 1. The new home may not have a garbage grinder, whirlpool bath/spa, or any other high usage fixtures. 2. If the onsite wastewater treatment systems fail, the systems must be brought into compliance with current regulations. 3. Approval must be granted by other agencies or municipalities having-jurisdiction. 4. Homes and accessory, buildings or structures must be installed such that a minimum separation distance of 10 feet exists between any home, building or structure on any other site or parcel of land. If improper separation distances are observed on the above lots in future inspections, enforcement action will be taken. Additionally, please,note that.this approval expires 1 year from the approval date. Sincerely, John C. Schroeder Senior Sanitarian NYSDOH - Glens Falls District Office 77 Mohican St. Glens Falls, NY 12801 (518) 793-3893 Cc: Rebecca C. Bussert, Acting District Director, Glens Falls District Office Kevin Kenyon, P.E., Glens Falls District Office Town of Queensbury Building Department File P:\Facility Folders\Forest Park Mobile Home Court\Correspondence\Forest Park Lots 9, 15,16,49,58,69,&78 Briwood;Lot 17 Gregwood;Lot 12 Timber;Lot 31 Woodland NOI Approval 06-11-21.Docx Glens Falls District Office,77 Mohican Street,Glens Falls,NY 12801,518-793-3893 1 gfdo@health.ny.gov rf vw f Jl,1d 2 �:021 1 I i �a� 16' x 76' Box PROPERTIES americErs home 20,24"x48" INGROUND PIERS 7---------------------------------------------------7' x _x_ _x_ _x_ x _ _x _x_ _x____ _x__ _ x 99.5" --- 99.5" 99.5'----99.5"----99.5"--- 99.5" --- 99.5" 99.5" —99.5" — —99.5" . c 0 ti 'a w : .c Y Y 2'OC x 767 X 8b7c X Fc X 8 5 X ——87F X 77C X 76C X 8bC X 8757 X 2,OC 2 10' 18' 26' 34' 42' S0' 58' 66' 74' Community: Forest Park(NY) Site Number. B078 Equals pier location-Note all measurments are to the centers of the piers. Approved: Information prepared based upon soil bearing capacity for the Site and calculations performed in accordance with the DAPIA approved factory set up manual. * * PLEASE NOTE - HOME IS ORDERED WITH PIER SAVERS AND DOOR PIERS ARE NOT REQUIRED PER MANUFACTURER. THIS INFORMATION IS AVAILABLE ON THE HOME ORDER AS WELL AS THE DATA PLATE FOR CONFIRMATION AT TIME OF FINAL INSPECTION. Safety First- All work to be conducted abiding by all industry safety rules & regulations Ce PRO PERT I ES I americE`s home' Manufactured Home Drainage Inground Pier Footing manufactured home Gravel bed under home r must have a crown to insure 1/2"per foot drop skirting no water remains under home L, for drainage 10' t into yard o gravel XURCAU 0 0" ARM, PENN,-) 14 RHO jQ0,000f,--!- 14 C) Ogg -0- 61-M 0""In lmmwi,MEM, ism niaw-M All grade material must be LEGEND compacted to a minimum concrete pier of 90% compaction. footing Existing grade Width and depth offiR."AbATOV 6" minimum Gravel* of foundation pier l determined by manufacturers i = Rough graded set up manual to achieve 1/2" per foot drainage Suitable material can replace gravel Vendor Initials: Illustration 2 in non-frost susceptible areas. March 2019 For illustration purposes only- Must follow instruction of manufacturers installation manual, HUD CFR 24-3280, 3285, 3286 and local codes. v Safety First- All work to be conducted abiding by all industry safety rules & regulations PRO PERT I ES I arnerica`s home`' Manufactured Home Drainage DO crown and grade site to DO NOT grade site or set the home so slope away from the home. -- that water collects beneath the home. i rEF-1 mini0'um ❑ El minimum slope 1/z" per foot .l -!__ NSA - 1 k:'e.����;� Y7`w-',r�:.�r"ter', :'^=�...ti e `K= ._ :"2t:."y'""""•:�. .,: .5��'",yr�':'�,;;`I mini�m'um minimum slope ,Xi" per foot NA Home sites shall be prepared so that there will be no depressions in which surface water shall accumulate beneath the home.The area of the site covered by the manufactured home shall be graded,sloped or mechanically designed so as to provide drainage from beneath the home. Vendor Initials: Illustration 5 March 2019 For illustration purposes only-Must follow instruction of manufacturers installation manual, HUD CFR 24-3280, 3285, 3286 and local codes. Safety First- All work to be conducted abiding by all industry safety rules & regulations P R O PE RT I ES I america's hornee Manufactured Horne Set Typical Footing and Pier Design Shims, when required, are to be used in pairs, must be 4" x 6" x 1" in size, installed in opposite directions and be fitted and driven tight between main I-beam frame and ` . :. shims or caps below. Shims can't occupy more than 1" Main I-beam of vertical height. Hardwood plates, shims, or other listed materials not exceeding 2" in thickness. '/2 x 8 x 16 steel caps, 2 x 8 x16 hardwood caps, or minimum '/2" x 8"x16" concrete caps, or other listed . , materials. See§3285.304(b)(2) for cap requirements. } ' ` Note - steel caps must be protected by a minimum of a 10 mil coating of an'exterior paint or an equivalent corrosion resistant protection. Single open or closed concrete blocks 8" x 8" x 16" Less than conforming to ASTM C-90 installed with 16" dimension 36" perpendicular to the main I-bean frame. Open cells are In hel ht placed vertically on footing. Mortar is not required g unless specified in the manufacturers installation instructions or required by a registered professional engineer or registered architect. Typical footing. Solid concrete or other product approved for the purpose. Footing is placed on firm undisturbed soil or on controlled fill, free of grass and organic matter. See manufacturers In freezing climates, the footing must extend below the installation manual for frost line or be otherwise rotected from the effects of instructions for piers over 36" in height. p frost heave as permitted here-in. Vendor Initials: Illustration `16 March 2019 For illustration purposes only- Must follow instruction of manufacturers installation manual, HUD CFR 24-3280, 3285, 3286 and local codes. Safety Rrst- All work to be conducted abiding by all industry safety rules & regulations es PROPERTIES I americECs home' Tie-Down Anchoring RHP-approved anchoring systems: • Tie Down Engineering Xi2 System Ground Level • Oliver Technologies, Inc. • Minute Man Stabilizer Plate • Central Piers, Inc. Diagnal Framed N Consult manufacturer's installation manual for requirements on frame JV and vertical sidewall anchoring, spaing and quantity of anchor points, Ground Anchor 17-' Longitudinal : and method and configuration of strapping. When installing anchors, ensure there are no obstruction underneath the home or potential for damage to underground utilities. Ground anchors and stabilizer plates must be installed at the Note: Public and private locating of proper angles, frame straps must be wrapped at least one underground utilities must be completed revolution over top of the main I-beam, as well as multiple before installing ground anchors. times around the anchor bolt, and must also be properly tensioned according to the installation instructions. Note: Straps should be protected at sharp at sharp corners and when wrapped around the I-beam. 77 .......... > Vendor Initials: Illustratio n 35 Ground Anchor and Strap April202O For illustration purposes only- Must follow instruction of manufacturers installation manual, HUD CFR 24-3280, 3285, 3286 and local codes. y Non-Corner SURVEY Lot 0arne4cM3horneb ,H0MES1TE* t Community Name: re�ffS-� 9if4 Site#: C $ City Set Backs: Front Yard: fl _ Rear Yard-(end to end): )s Side Yard: D' Recommended Home Size: Are Overhead Power Lines Present? YesMNo • I Considerations in [Determining Home Size: . Source of Home Heating (check box):. Natural Gas Propane Heating Oil Electricity i Please provide a Drawing In the center space above that indicates the elements listed below with measurements: • Existing pad runners/ribbons or Piers • Existing driveway• Existing approach(walkway to home) o Locate sewer,water,electrical• Indicate the location of natural gas hookup,propane tank or heating oil tank,If applicable. j Nome Horne Home Total Length of Site Distance between homes (Distance from home to curb) Distance between homes i Total feet between homes i Addition, ' ¢� Addition, r- Steps ` Steps 3 i or Deck Width Width or Deck CO of Porch or NA of Porch �- or NA o i s Depth of Porch Depth of Porch i Carport Carport Yes o No Yes size: x X size: Distance from Distance from curb to home Show oeation of any curb to home overh ad power lines ' i Maximum Building Envelope Size: Width: }— Length: Dame of person fillip out this form: �!�^� Date: ��1� o Form Revised - 9 Octoher2019