SEP-0583-2022 SEPTIC VARIANCE office use!only
Permit#:
W _ 6
'b`�o , - 7�d22-
APPLICATION Permit Fee: -
7-own d4Xcncbury
Invoice
742 Bay Road,Queensbury,NY 12804
P:518-761-8256 www.cl6een9b"urv:rie4 Approvals:i -
Submittal: 1 (one) original &8 copies of the completed ap! ckage
rF-
PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE Q
,Section 1: SEP 19 2022
Contact Information: TOWN OF
QUES
Property Owner(s): Carl & Mph ple Welder Owner's Agent: H �� U y
Address: P.O. Box 2516 Address:. 169 Haviland Road
Briarcliff Manor, NY 10510 Queensbury, NY 12804
Phone#:(914).548-0.197548-0.197 Phone#: 518-745-0307
Email: Email: thutchins@�hutchinsengineering,com
Section 2:
I
Site Information:
Site Address: 114 Rockhurst Road Tax ID#: 22�,.9-1-9
Directions to site: from NY-9L N turn right onto Cleverdale Road for 0.8 miles; right onto Rockhurst Rd
Section 3: for 0.7 miles; parcel on right side
Lake Water Supply
Distance from WeUon property to septic system(if applicable) 63 feet
I
Section 4:
Is it possible to install a conforming septic system on this property? ❑Yes Q No
If YES, please explain and attach a diagram::.
Section 5•
_ I
I
Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring
properties? QYes ❑ No If NO, please explain: No Neighboring Wells
I
Section 6:
Is the proposed system to be installed under a parking area? Al Yes ❑ N'
Section 7:
Section of the Sanitary Sewage Ordinance from which you are seeking the variance(i.e. leaching system will be 89 ft.
from well in lieu of required 100 ft.): Absorption field to Shoreline:63'proposed instead of requiretl 100'(37'of relief requested)
Absorption Field to Westerly Property Line:1'proposed instead of required 10'(9'of relief requested)
Septic variance Application Effluent Sewer Line to Westerly Property Line:4'proposed instead of 10'required(6'of relief requested)
House Sewer Line to Westerly Property Line:4'proposed instead of 10'required(6'of relief requested)
I
I
I
Section 11:
AUTHORIZATION AND SIGNATURE PAGE
This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site
visits, other permit responsibilities and agreement to provide documentation required.
Complete the following if the OWNER is using an Agent:
Owner's Name: Carl Weider
Designates: Hutchins Engineering PLLC as agent regarding the Septic Variance for
Site Address: 114 RoCkhurst Road
Tax Map#:
227.9-1-9
EneineerinR Fee-Disclosure:.Applications may be referred to the Town consultiIng engineer for review of septic
design,storm drainage,etc. as determined by the Town Board of Health. Fees
for engineering review services
will be charged directly to the applicant.
Authorization for Site Visits By signing this page and submitting the applicati In materials attached herein, the
Owner,Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code
Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the
application submitted.
Please Note: Other permits may be required for construction or alteration actil ity subsequent to approval by
the Town Board of Health. It is the applicant's responsibility to obtain any additional permits.
Official Meeting Minute-s Disclosure: It is the practice of the Town Board of Health to have a designated
stenographer tape record the proceedings of the meetings resulting from the application, and that the
minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy
between such record and the handwritten minutes taken by the designated stenographer,the handwritten
minutes shall be deemed the official record.
i
I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the
submission requirements and completed checklist:
1
OWNER—PRINT NAME: Carl W�@I/ller
OWNER—SIGNATURE:��Ax U)64;� DATE: 09/15/22
AGENT—PRINT NAME: A
i
AGENT—SIGNATURE:- �--�. I DATE: Z
Revised December 2021
Septic Variance Application
i
j 169 HaViland Road
Queensbury, NY 12804
Hutchins Engineering j Phone: (518)745-0307
Fax: (518)745-0308
i
i
I
I
September 16, 2022 D E E OW E
I
Town of Queensbury, Local Board of Health SEP 19 2022
742 Bay Road
Queensbury, NY 12804 TOWN OF QUEENSBURY
BUILDING&CODES
Re: Residence of Carl and Michele Weiner
114 Rockhurst Road, Queensbury
Tax Map ID#: 227.9-1-9
Dear Supervisor Strough and Town Board Members:
Attached please find a plan and application for septic variance to allow a replacement septic
system to be installed for owners Carl and Michele Weiner at the above-referenced residence.
We are seeking relief from property line setbacks as well as separation from the absorption field
to the shoreline.
The proposed treatment system will consist of a FujiClean CE-5 enhanced treatment unit and a
10'W x 30'L crushed stone absorption bed with two rows of four 34'' traffic rated Infiltrator H-20
chambers. Every effort has been made to provide a high-quality enhanced treatment system and
minimize requested variances;
We are seeking relief from the absorption field setback to shoreline (63' proposed instead of
required 100'), the absorption field setback to westerly property line (1' proposed instead of
required 10'), the effluent sewer line to westerly property line (4' prop losed instead of the required
10'), and the house sewer line to the westerly property line (4' proposed instead of the required
10
We respectfully request to be placed on the board schedule for the upcoming September 26
meeting.
i
Please contact me if you have any questions or if you require additioinal information.
Best Regards,
G. Thomas Hutchins, P.E.
Cc: Carl and Michele Weiner
i
G.Thomas Hutchins,P.E. thutchins@hutchinsengineering.com
i
Split Rail Fence
CIRF
PROP.10'W x 3W'L CRUSHED
STONE ABSORPTION BED WITH
(2) ROWS OF (6)- 34" WIDE TRAWFIC RATED
OPEN-BOYTOM GRAVELLESS CHAMBERS /
. v a
v� j qy
V
Concrete Drive
`� v1V i,A
EXIST CESSPOOL
22 7.9 -1- 7 TO BE REMOVED
113 Rockhurst ftoa-d- /
Lands of
Lorraine Dickinson
8:1161 P:58
LAKE WATER
SUPPLY
PROP. 4 PVC SCH-40 -
HOUSE SEWER
2% MIN. SLOPE
EXIST CESSPOOL -
TO SE REMOVED
U�
�s
227.9-1-6
111 Rockhurst Road
Lands MIF of
John & Carolyn Swan
8:5107 P:35
LAKE WATER
SUPPLY
CIRS
4" PVC SCH-40
CLEAN-=
TO GRADE mp )
Lands N/F of
Lambert's Landing LLC
8:5023 P:173
227.9 -1- 8 LAKE WATER
SUPPLY
o
NM17 O N. s
CIRIF s�Q'�� S T 00 00" E s`'� CIRI= o
' 64.00' } 6*-
Shed
t ° \ {
1 2" Spruce
SF SF �
1W P.L. SETBACK��`A► i0 5ri0 s .
PROP. SEDIMENT
- CONTROL FENCE
227.9 -1-�9
114 Rockhurst Ro\ad i 1
10 PT-1 28" He lock peck
Lands of " j t
�arl & Michele Weiner t 4 1
VERTICAL DATUM
SR 8: 4226 P: 265
Area NORTH AMERZCAN VERTTCAL DATUM OF 1929 (NGVD29)
1415�8.2 Sq. Feet L
r'
0. 1; Acres o
. f ` LAM WATER I 1I tM
r
0 1
T`
r
., rY 94
. ,
-� PROP. 4' PVC SCH-40 �
EFFLUM SEWER
PROP. 28'" POLY BASIN
W 1RTSER FOR W UNIT t t
I PROP. FU]ICLEAN CE 5
ENHANCED TREATMENT UNIT l 1 1
PROP. 4" PVC SC" - A , t C7 .
HOUSE SEWER
tIIi`s;i:{{. ii' ~` °:P:;.;,'L i;..••.. O i } ti 1 k !
{{. S _ 1
♦=F=33Q~� '• iii tl � � 111 `
{ { tt t {t;{ t°;� t, t } ` = i . � t"�� i" '? { l i .; •'�' •" " ", ''," •"�" 1
{ { Y{ tt{;"{ ie{''t'1l'� r l 1
t t tt { t j l { i , ;'.: �'::: E7 :3' .+':: ... , PROP.4" PVCSCK4M
tt I'. { {
i A l tit { HOUSE SEWER e
{ ;. {•t {t s 1� I1111.1-3302t
i�{{�t•'• t{��'1'{i�`it;i�.
Retami 'Wall
i'
Lake
George
Sandy
Bay
I{ � 4i' jt S � �♦' � i y
.328.0�}': (r ~ Come Walk .-`
Covered
13.01±Dock: I
Ramp i —
:�
• n � �Ole-
0. rW.
:
HOUSE SEWER
I INV.1- 3315f
44" rl pl
WL WL WL WL jj
—j-- WL WL WL WL
� 1
�LAKE WATERINTAt�
It APPROXLMATE LOCATION
Concrete
�V
24" tiemlojck
30" Hemlock
1W P.L. SETBACK{lapA
+1 Il
oPropane Tanks
+i
I 12" He lock 1
NM 6 ° �' Lene-rat�o
v Stockade Fencef Stockade Fence h
r' _
N 79000' 00" W ° Nail Set in Root 10 0 ��
='tits{t4ttli`c{`{''' s 227"9-1-10 m
112 Rockhurst Road
Lands N/F of
} Eric K Cottrell LAKE WATER
B:1441 P:102 SUPPLY
WASTEWATER SYSTEM PLAN
SCALE: 1-=10'
GRAPHIC SCALE
5 0 2.5 5 10 20
IN FEET )
SEPTIC VARIANCE SUMMARY
NYSDOH APPENDIX 75A WASTEWATER TREATMENT STANDARDS
TABLE 2 SEPARATION REQUIREMENTS
1. ABSORPTION FIELD TO SHORELINE
100' REQUIRED
63' PROPOSED
37 OF RELIEF REQUESTED
2. ABSORPTION FIELD TO WESTERLY PROPERTY LINE
10' REQUIRED
1'PROPOSED
9' OF RELIEF REQUESTED
3. EFFLUENT SEWER LINE TO WESTERLY PROPERTY LINE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
4. HOUSE SEWER LINE TO WESTERLY PROPERTY LINE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
SITE SOILS DATA
TEST PIT
TP-1 - 8110122 BY T. HUTCHINS, P.E.
AREA OF PROP. ABSORP71ON FIELD
0-4" TOPSOIL/GRASS
4-60" MIXED SAND & CONCRETE & BRICK
DEBRIS FROM OLD HOTEL
NO BOUNDARY CONDITION ENCOUNTERED
PERCOLATION TEST
PT-1 - 8110122 BY: T. HUTCHINS, P.E.
STABILIZED PERCOLA77ON RATE: 4 MIN11N
IN BLENDED NA TA E AND FILL MATERIAL
SITE LOCATION LOCATION MAP
d
SEP 19 2022
T WN DF QUEENSBURY
G & CODES
227.9-1-9 SEP-0583-2022
Weiner, Carl & Michele
114 Rockhurst Rd
Septic Variance/Alteration
WASTEWATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELL
WATERLINE
HOUSE
LAKE GEORGE
SEPTIC TANK, PUMP
STATION, FORCE MAIN,
EFFLUENT SEWER
10,
50'
10,
10'
50'
ABSORPTION FIELD
10,
100,
10,
20'
100,
Dig INA Safely,
New York
■ Call Before You Dig
■ Wait The Required Time
■ Confirm Utility Response
■ Respect The Marks
■ Dig With Care
800.962.7962
www.dlgsafelynewyorkAmm
MAP REFERENCE:
BASE MAP INFORMATION FROM "MAP OF A SURVEY
MADE FOR CARL AND MICHELE WEINER,- IN THE
TOWN OF QUEENSBURY, WARREN COUNTY, NEW
YORK. DATED FEBRUARY 1, 2022. PREPARED BY.•
8, D u s e.0
Steves
Land Surveyors ALTERATION OF THIS DOCUMENT EXCEPT
BY A LICENSED PROFESSIONAL
169 HsvMmd Road Queensbury, New York 12804 ENGINEER IS A VIOLATION OF NYS
(518) M-8474 Now York Uc. No. 50135 EDUCATION LAW.
TAX MAP # 227.9-1-9
0 ISSUED FOR SEPTIC VARIANCES
No. Revisions
WASTEWATER SYSTEM PLAN
prepared for.
Carl & Michele Weiner
114 Rockhurst Road
Town of Queensbury, County of Warren, State of New York
Drawn: JRS11WD Checked: GTH I Scale: NOTED Date:
169 Haviland Road
911512022
Date
Queensbury, NY 12804 292001-01-S 1
Hutchins Engineering PLLC (518) 745-0307 Phone
g g (518) 745-0308 Fax
ft
ft
WASTEWATER SYSTEM DESIGN
3-BEDROOM REsrDEnlcE
WATER SAVING FIXTURES
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
PRETREATMENT TANK - FUJICLEAN MODEL CE-5 E.T.U.
DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON
6-7 MIN/IN PERCOLATION RATE
(BLEND OF NATIVE & FILL SOILS)
ABSORPTION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF)
= 413 SF
33X E.T.U. REDUCTION AREA REQ'D = 276 SF
ABSORP10 BED AREA PROVIDED = 10'X3O' - 300 SF
WITH 2 LATERALS OF 4 H2O CHAMBERS
WASTEWATER SYSTEM FILL
MATERIAL NOTES
AFTER REMOVING ORGANICS TOPSOIL AND DEBRIS, PLACE SYSTEM
FILL OVER THE EN71RE AREA OF PROPOSED ABSORPTION BED AND
TAPER AREA.
OABSORP71ON AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY
SELECTED SAND OR SANDY LOAM WITH IN -PLACE PERCOLATION
RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3"
IN SIZE LESS THAN 10% BY WEIGHT SHALL BE FINER THAN
0.05mm. AT LEAST 25X OF THE MATERIAL BY WEIGHT SHALL BE
IN THE RANGE OF 0.50mm TO 2.0mm. LESS THAN 157. OF THE
MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE
ABSORPTION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED
TO PROVIDE MINIMUM OF 3-FEET BETWEEN BOUNDARY CONDITION
AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL
SHALL BE INSTALLED THROUGHOUT THE ABSORPTION BED AREA
AND TAPER AREAS
ABSORPTION AREA SYSTEM FILL MATERIAL 1S TO BE
MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT
PRIOR TO INSTALLA71ON OF ABSORPTION TRENCHES
INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF
SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE
SYSTEM MATERIAL SPECIFICATIONS
34" WIDE OPEN -BOTTOM GRAVELLESS CHAMBER
OPEN -BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH
CAPACITY.
HOUSE SEWER PIPE
PIPING TO BE 4" SCH-40 PVC INSTALL WITH 1/4" PER FOOT
MINIMUM SLOPE.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/8" PER FOOT
MINIMUM SLOPE.
ABSORP7101V8ED AGGREGATE
STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION
FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT.
STABILIZATION FABRIC
STABILIZATION FABRIC TO BE WOVEN GE07EX71LE WITH
POLYPROPYLENE YARNS, 7HRACE UNQ GTF-300 OR EQUIVALENT.
FILL MATERIAL.
FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED
IN "FILL MATERIAL NOTES "
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORPTION FIELD
AREA. SEED AND ESTABLISH TURFF,
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE
WITH THE N.YS DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND
ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN
SEP77C TANK LEACH FIELDS
AFTER PLACEMENT OF SYSTEM FILL AND EXCAVA77ON OF 10' WIDE X 30' LONG
ABSORPTION BED . TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE
CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL
BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE
GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT
CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER
UNSUITABLE CONDITIONS PIPE SHALL BE LAID WI714 HOLES DOWN IN ALL CASES
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT
SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN 7HE ABSORPTION AREA AFTER PIPING
HAS BEEN INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON
7HE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110
GPO PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME
WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT THE INSTAH A71ON OF NON -CONSERVING WATER FIXTURES OR
EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS
WASTEWATER TREATMENT SYSTEM.
.ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE
EXCLUDED FROM THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT
SURFACE RUNOFF AROUND ABSORPTION FIELD.
SEP77C TANK, PUMP STA17ON & ABSORPTION BED MUST BE INSPECTED BY TOWN
OF QUEENSBURY BUILDING DEPAR7IMENT AND DESIGN ENGINEER PRIOR TO
BACKFILL AND FINAL GRADING. IT IS 7HE RESPONSIBILITY OF THE CONTRACTOR
TO IDENTIFY THE NECESSARY PAR7IES AND REQUEST INSPECTIONS
10'-0' 36" FENCE POST DRIVEN
O.C. MAX MINIMUM 16" INTO GROUND
[rGROUND
S/LTSTOPEMBED IN
8" MIN.
...........:..........<__..__ ..
I„� � FLOW �•,,�
8" MIN. z ..
w
0� PSWECTIVEE SOIL BACKFlLL SECTION
SEDIMENT CONTROL FENCE DETAIL
NTS
STANDARD SPECIFICATIONS FOR SILT FENCE
ROADWAY Z 4" MIN. TOPSOIL,
SEED, MULCH &
10' BED WIDTH ESTABLISH TURF
W 8" MIN. I7EM-4 GRAVEL
4 ( r 4" 4' CHAMBER SPACINGT_
SUBBASE COURSE
34" CHAMBER WIDTH
INFILTRATOR H-20
CHAMBER SECTION
36' FENCE POST NTS
SILT STOP EMBED IN
GROUND 8" MIN.
UNDISTURBED GROUND
- SENSITIVE AREAS TO BE PROTECTED BY SILT FENCE MAYBE NEED
DEFINITION
TO BE REINFORCED BY USING HEAVY WIRE FENCING FOR ADDED
A TEMPORARY BARRIER OF GE07EX71LE FABRIC INSTALLED ON THE CONTOUR ACROSS
SUPPORT.
A SLOPE TO INTERCEPT SEDIMENT LADEN RUNOFF FROM SMALL DRAINAGE AREAS OF
- WHERE THE ENDS OF THE SILT FENCE COME TOGETHER, THE TWO
DISTURBED SOILS
ENDS SHALL BE OVERLAPPED, ROLLED TOGETHER AND STAPLED
PURPOSE
70 PREVENT SEDIMENT BYPASS AT 7HESE CONNECTIONS
TO REDUCE RUNOFF VELOCITY & TO EFFECT DEPOSITION OF TRANSPORTED SEDIMENT
FABRIC MATERIAL CRITERIA
LOAD.
GRAB TENSILE STRENG7H : 90 LBS ASTW 01682
ELONGATION AT FAILURE: 50% ASIM D1682
APPLICATION
:CONSTRUCTION SPECIFICATIONS
- MAXIMUM ALLOWABLE SLOPE LENGTHS CONTRIBUTING RUNOFF TO THE FENCE
1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE
PLACED ON A SLOPE:
POSTS WITH WIRE 71ES OR STAPLES. POST SHALL BE STEEL
1:2 SLOPE (50%) 25 FT
EITHER "r OR 'U" TYPE OR HARDWOOD.
1:3 SLOPE (33%) 50 FT
2 FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE
1:4 SLOPE (25%) 75 FT
FENCE WITH 71ES SPACED EVERY 24" AT TOP AND MID SECTION.
1:5 SLOPE OR LESS 100 FT
FENCE SHALL BE WOVEN WIRE, 6' MAX. MESH OPENING.
- MAXIMUM DRAINAGE AREA FOR OVERLAND FLOW SHALL NOT EXCEED 1/4 ACRE
3 WHEN TWO SEC71ONS OF FILTER CL07H ADJOIN EACH OTHER
PER 100 FEET OF FENCE WITH MAXIMUM PONDING DEP7H OF 1.5 FEET.
7HEY SHALL BE OVER -LAPPED BY 6-INCHES AND FOLDED.
FILTER CLOTH SHALL BE E17HER FILTER X, MIRAFI 10OX,
- EROSION WILL OCCUR AS SHEET EROSION.
STABILINKA T140N OR APPROVED EQUIVALENT.
- CONCENTRATED WATER FLOW SHALL NOT BE DIRECTED TO FENCE.
4. PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE OR
DESIGN CRITERIA
APPROVED EQUIVALENT.
- ALL SILT FENCES SHALL BE PLACED AS CLOSE TO THE DISTURBED AREAS AS
5 MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL
POSSIBLE, WIN A MINIMUM OF 10 FEET FROM 7HE TOE OF A SLOPE. THE AREA
REMOVED WHEN "BULGES' DEVELOP IN 7HE SILT FENCE.
BEYOND THE FENCE MUST BE UNDISTURBED OR STABILIZED.
IMBER
HT
U 75" EFFECTIVE LENGTH
INFILTRATOR H-20 CHAMBER PROFILE
NTS
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
1/4" PER FOOT 2"
MIN. SLOPE
4" PVC SCH-40 HOUSE SEWER
CHAMBER I ICHAMBER 2
SEDIMENTATION OBIC CONTACT
CHAMBER TRA770N CHAMBER
59'
RUR47ION
16" CHAMBER
HEIGHT
SALCOR UV
I
ELECTRICAL JUNCTION
BOX WITH INDICATORS
I AND ALARM CONTACTS
j
GROUND LEVEL
DISINFECTION UNIT
DISiNFEC7ION
SUB — ASSEMBLY
HANDLE
{ -
i
FOR
II
REMOVAL
i
I
I
SUPPORT
I
FRAME & —•.
GASKET
4" PIPE
1
TREATMENT
j
PLANT
i
TEDEFFLUENT EFLUENT I
F�.NFEC
f
UV LAMP/
&
QUARTZ TUBE
I
i
TEFLON COVER
A
A
SECTION A -A
i
i
I
NOTE: NOT ALL DIMENSIONS TO SCALE
I --UV LAMP
& i
4 \ TEEFL�ON COVBEER
I --SUPPORT FRAME
AND GASKET
_
INSTALL POLYE7HYLENE EXTENSION -
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL SALCOR
ULTRAVIOLET
TREATMENT UNIT
1/8" PER FOOT
MIN, SLOPE
4" PVC SCH-40 EFFLUENT
28" DIA. POLY BASIN,
100 GAL
SALCOR UV DISINFECTION UNIT
NTS
1/8" PER FOOT
MIN. SLOPE
4" PVC SCH-40 EFFLUENT SEWER
TO INFILTRATOR CHAMBERS
FUJI CLEAN USA MODEL CE-5
ENHANCED TREATMENT UNIT
MAINTENANCE CONTRACT NOTE FUJI CLEAN ENHANCED TREATMENT UNIT & UV VESSEL DETAIL
A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM NTS
OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED
FOR SEMI-ANNUAL INSPECTION AND SERVICE OF THE
FUJICLEAN CE-5 ENHANCED TREATMENT UNIT. TAX MAP # 22Z9-1-9
WASTEWATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELL
WATERLINE
HOUSE
LAKE GEORGE
SEP77C TANK PUMP
STATION, FORCE MAIN,
EFFLUENT SEWER
10,
50'
10,
10,
50'
ABSORPTION FIELD
10,
100,
10,
20'
100,
Dig (Safely.
New/.York
■ Call Daiwa You Dig
■ Wait The Required Time
■ Confirm Utility Response
■ Respect The Marks
■ Dig With Care
800-962-7962
www.dig"fotynewywk.com
t
i
SEPTIC DISPOSAL PERMIT Office Use Only
- APPLICATION' Permit#: � — C���3-2022—
Town vi
otOjiec bin• O -- - Permit Fee:$ g5'
FCT 21 2022O Invoice#: ��ZZ
742 Bay Road,Queensbury,NY
i�D 2, 2
Z
P:518-761-8256 www.queensbury:npeiit; Septic Variance?
i
Flood Zone?rw,
Wetlands?�a Reviewed B
Project Location: 114 ROCKHURST ROAD
Tax Map#: 227.9-1-9
RESIDENCE INFORMATION:
Year Built Gallons #of bedrooms: X gallons per =total daily flow
per day bedroom Garbage Grinder Yes No
1980 or older 150 Installed? (choose one) ❑ x❑
1981-1991 130 Spa or Hot Tub Yes No
1992-Present 110 3 • 110 330 Installed? (choose one) ❑ x❑
I
PARCEL INFORMATION:_
Topography Flat Rolling ❑ Steep Slope % Slope
Soil Nature Sand ❑ Loam ❑ Clay 0 Other, explain:
Groundwater At what depth? >60"
Bedrock/Impervious material At what depth? >6011
Domestic Water Supply ❑ Municipal ❑ Well Lake
(if well or lake, water supply from any septic system absorption is
ft.)
Percolation Test Rate: 6-7 per minute per inch (test to be completed by a
licensed engineer/architect)
PROPOSED SYSTEM INFORMATION:
Tank size E.T.U. gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or
spa/hot tub
System Absorption_field w/#2 stone Total length ft.; Eac,h Trench ft.
Seepage Pit w/#3 stone; How many: ; Size:
Alternative System Bed or other type: 10x30 WITH CHAMBERS
Holding Tank System Total required capacity? ; tank size ;
#of tanks
Septic Application Revised July 2022
TOWN OF QL'IEENSBURY
742 Bay Road, Queensbury, NY. 12804-5902
Septic System Checklist
LPlan to scale
Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and
Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects)
�-QAII wells on property and adjacent properties shown
Water line shown Municipal or well 10'separation to any part of system
/ Setback to property lines show 10'or more for any part of system
? �Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline
Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank
for 0',Separation required(field verification required)
Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each
I
Leech Field 20'from foundation 100'from any well 10'from water line
nnLtyyjj i
Aseepage pit 150'from well 50'from septic tank
ti,Seepage Pits 3-times diameter apart
Septic tank and pump stations over 30 gallons 50'from watercourse or wetland'z-
distance from bottom of trench or system 24"to bedrock or mott nD6-mr",, hin 1000'of Lake George
Leech field 100'from watercourse or wetland 2. - 1'- •,�-=
1" -oe of mound or bottom of retaining wall 10'from property line 100'from well 20'from
Foundation
Provide Engineer/Architect stamp for bed or design systems
pLDepartment of Health Approval for all mobile home park new systems Flood Plain requirements .
t! 2'above established flood elevation to bottom of system
Y1 All tanks anchored or 2'above flood elevation
vo,aooA an anent
f`
RESOLUTION APPROVING CARL AND MICHELE WEINER'S
APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES
RESOLUTION NO.: BOH 82,2022
INTRODUCED BY: Mr. Timothy McNulty 227.9-1 9 SEP-0583-2022
WHO MOVED ITS ADOPTION Weiner,, ' arl & Michele
SECONDED BY: Mr.Anthony Metivier 114 Rockhurst Rd
Septic Variance/Alteration
WHEREAS, Carl and Michele Weiner (Applicants) filed an application for variances from
provisions of the Town of Queensbury On-Site Sewage Disposal Ordinance, Chapter 136 to install
a replacement septic system with the:
i
1. Absorption field to be located 63' from the shoreline j in lieu of the required 100'
i
setback;
2. Absorption field to be located 1' from the westerly property line in lieu of the
required 10' setback;
3. Effluent Sewer Line to be located 4' from the westerly property line in lieu of the
required 10' setback; and
4. House Sewer Line to be located 4' from the westerl i property line in lieu of the
required 10' setback;
on property located at 114 Rockhurst Road in the Town of Queensbury, and
WHEREAS,the Town Clerk's Office published the Notice of Public Hearing in the Town's
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
variance requests on Monday, October 17t',2022, and
WHEREAS, the Town Clerk's Office has advised that it duly'notified all property owners
within 500 feet of the subject property,
NOW,THEREFORE,BE IT
RESOLVED,that
1. due to the nature of the variances, the Local Board of Health determines that the
variances would not be materially detrimental to the purposes and objectives of this
Ordinance or other adjoining properties nor otherwise conflict with the purpose and
objectives of any Town plan or policy; and
2. the Local Board of Health finds that the granting of the variances is necessary for the
reasonable use of the land and are the minimum variances which would alleviate the
specific unnecessary hardship found by the Local Board of Health to affect the
Applicants; and
BE IT FURTHER,
RESOLVED, that the Local Board of Health hereby approves the application of Carl and
Michele Weiner for variances from the Sewage Disposal Ordinance to install a replacement septic
system with the:
1. Absorption field to be located 63' from the shoreline I in lieu of the required 100'
setback;
2. Absorption field to be located 1' from the westerly ,property line in lieu of the
required 10' setback;
3. Effluent Sewer Line to be located 4' from the westerly property line in lieu of the
required 10' setback; and
4. House Sewer Line to be located 4' from the westerly property line in lieu of the
required 10' setback;
on property located at 114 Rockhurst Road in the Town of Queensbury and bearing Tax Map No:
227.9-1-9, and
BE IT FURTHER,
RESOLVED, that the Enhanced Treatment Unit (ETU) shall be maintained by the property
owner in accordance with the manufacturer's recommendations for the life of the system, and
BE IT FURTHER,
RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by
certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review, and
BE IT FURTHER,
RESOLVED, that this approval Resolution shall not be effective until 30 days after such
notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park
Agency during such period.
Duly adopted this 17fl'day of October,2022,by the following Vote:
AYES : Mr. Ferone,Mr. McNulty,Mr. Strough,Mr. Metivier
NOES : None
ABSENT: Mr. Freer
S
Split Rail Fence
CIRF
PROP.1WW x 30'LCRUSHED
STONE ABSORP'T10% BED WITH
(2) ROWS OF (6)- 34" WIDETRAFFIC RATED
OPEN -BOTTOM GRAVELLESS CHAMBERS /
fI
I
One Story Wood ll
Frame douse
A/C
.1.
V
Concrete Drive
d , j
'el, 4
EXIST CESSPOOL
227.9 -1- 7 To BE REMOVED
113 Rockhurst RlfaV- r
Lands of
Lorraine Dickinson
B:1161 P:58
LAKE WATER
SUPPLY
PROP. W, PVC SCH-40 -
HOUSE SEWER
2% MIN. SLOPE
EXIST CESSPOOL -
TO BE REMOVED
U�
22 7.9 -1- 6 CI R5
111 Rockhurst Road
Lands NIF of
John & Carolyn Swan
8:5107 P:35
LAKE WATER
SUPPLY
4" PVC SCH-40
CLEAN-01T[
TO GRADE (TYP )
O
1
1
1
1
4'
Lands NIF of
Lambert's Landing LLC
B:5023 P:173
227.9 -1- 8 LAKE WATER
SUPPLY
o
NM 17 O _o
CIRF S 7V00'00° E
64.00, 6 ±
� Shed NI
12" Spruce
SF SF
1W P.L. SETBACK p 5H0 \
3AB5 S14 Q.p t s
PROP. SEDIMENT
CONTROLFENCE t
227.9-1�
i 114 Rockhurst Road '3}
1W PTA ' n Lands of 25" Hemlock
Cfr1 & Michele Weirder 1 l VERTICAL DATUM
B:4226 P:265
NORTH AMERICAN VERTICAL DATUM OF 1929 (NGVD29)
Area
" 14158.2 Sq. Feet L
0. 34 Acres
1
L WATER a�
k
0
� Fireplace- Lake
r ` ' E PROP.4"' PVC SCH-40�
EFFWEliT SEWER 1 -
'~ PROP. 28" POLY BASIN
V11MERFORUVUNTT Georae
4`Playhouse: N
PROP. FU]ICLEAN CE-5 i I
ENHANCED TREATMENT U%V l � } t
PRP.4" P4CSCH-48 Sandy
NOvsE SEWER � � � � �, {: Bay
;jib
j S
't�'�! sf '`: " ` I i
X \'X\-\X
0
i i?\ '. t
��t i 'A\ � � � �� ' � � °' , , , :..::::: _�.: ,. � � � PROP. 4 PVC SCH-40 VOMSEWER
1 t
St
Retamm Imall
32,b 44' Comte Waa V�
<I
�;:::: � -:: ' ��::.:, ::'.�:•:.::::::::�:.','�:. ;.•,�:.:::-;R; -- --- `_' .,. { � � � I Covered
- 13.f7 Dock l
!- O Ramp
ilf oro
k Shed
PROP. 4'° PVC SGH-40 o
... '.......... DER t `}
INV,1=3315i t
w� -=- w< w< w� 44") pl wl wL wL wL -
F 33,E �- —;-
V' ,
t j 14" Mapfe LAI�WATERINTAKE
APPROXIMATE LOCATION
Concrete
24" Hemlock
• Y , _\,_ _ _ _ _ � � � 30 Hemlock
f
10' P L. SETBACK
oPropane Tanks \
1 2" He lock 1 1
NM 6 0 \ enerato
Stockade Fence/ � Stockade Fence
t \ �s N 79000'00" W Na11 Set in Root 10'±
ch o'
°',` 227.9-1-10 �� m
} 112 Rockhurst Road �
Lands NIF of
10A GaraqeEric K Cottrell LAKE WATER
8:1441 P:102
WASTEWATER SYSTEMPLAN
SCALE: 1 "=10'
GRAPHIC SCALE
5 0 2.5 5 10 20
( IN FEET
SUPPLY
SEPTIC VARIANCE SUMMARY
NYSDOH APPENDD(75 A WASTEWATER TREATMENT STANDARDS
TABLE 2 SEPARATION REQUIREMENTS
1. ABSORPTION FIELD TO SHORELINE
100' REQUIRED
63'PROPOSED
37OF RELIEF REQUESTED
2. ABSORPTION FIELD TO WESTERLY PROPERTY LINE
10' REQUIRED
1'PROPOSED
9' OF RELIEF REQUESTED
3. EFFLUENT SEWER LINE TO WESTERLY PROPERTY LINE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
4. HOUSE SEWER LINE TO WESTERLY PROPERTY LINE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
SITE SOILS DATA
TEST PIT
TP-1 - 8110122 BY.- T. HUTCHINS, P.E.
AREA OF PROP. ABSORP7ION FIELD
0-4" TOPSOIL/GRASS
4-60" MIXED SAND & CONCRETE & BRICK
DEBRIS FROM OLD H07EL
NO BOUNDARY COND171ON ENCOUNTERED
PERCOLATION TEST
PT-1 - 8110122 BY T. HUTCHINS; P.E.
STABIL aED PERCOLAT ION RA 7E 4 MIN17N
IN BLENDED NA77VE AND FILL MATERIAL
SITE LOCATION
TOWN OF QUEENSBURY
BUILDING & 2E�r-TReviewed By
Date:
TOWN OF QUEENSBURY
BUILDING DEPARTMENT
Based on our limited examination, compliance
with our comments shall not be construed as
indicating the plans and spepfications are in
full compliance with the Building Codes of
New York State.
LOCATION MAP
227.9-1-9 SEP-0583-2022
Weiner, Carl & Michele
114 Rockhurst Rd
Septic Variance/Alteration
FILE COPY
NEIGHBORHOOD MAP '--SITE LOCATION
WASTEWATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELL
WATERLINE
HOUSE
LAKE GEORGE
SEPTIC TANK PUMP
STATION, FORCE MAIN,
EFFLUENT SEWER
10,
50'
10'
10,
50'
ABSORPTION FIELD
10,
100
10,
20'
100,
TAX MAP # 227.9-1-9
Dig Safely.
New/.York
■ Call Before You Dig
■ Wait The PAKpd ed Time
0 Confirm Utlllty Response
■ Respect The Clarks
® Dig With Care
800-962-7962
1
ADDED APPROVAL RESOLUTION (SHEET S3) - ISSUED FOR PERMIT
1012012022
0
ISSUED FOR SEPTIC VARIANCES
911512022
wwwAigsafslynewyork.00m
No.
Revisions
Dote
WASTEWATER SYSTEM PLAN
prepared for.
Carl & Michele Weiner
-
- 114 Rockhurst Road
. oN E VWV y
MAP REFERENCE. NS HIJ
BASE MAP INFORMATION FROM "MAP OF A SURVEY ��,0�'
FOR CARL AND MICHELE WEINER, 0 IN THE
TOWN OF QUEENSBURY, WARREN COUNTY, NEW c7
YORK. DATED FEBRUARY 1, 2022. PREPARED BY: U
n Du. s h
0, e
Steves
Land Surveyors
159 Havilmd Road Queensbury, New York IN"
(518) M-8474 New York Uc. Nc. 50135
-
���� O67 "A
`�� ��'-
ALTERATION OF THIS DOCUMENT EXCEPT
BY A LICENSED PROFESSIONAL ENGINEER
JIS A VIOLATION OF NYS EDUCATION LAW.
Town of Queensbury, County of Warren, State of New York
Drawn: JRS/LWD
Checked. GTH
Scale: NOTED
Date: 81412022
169 Haviland Road
Queensbury, NY 12804 292001-01-S1
(518) 745-0307 Phone
Hutchins Engineering PLLC (518) 745-0308 Fax
WASTEWATER SYSTEM DESIGN
SYSTEM INSTALLATION NOTES
3-BEDROOMRESULNU
WATER SAVING FIXTURES
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
PRETREATMENT TANK - FUJICLEAN MODEL CE-5 ETU.
DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON
6-7 MIN/IN PERCOLATION RATE
(BLEND OF NATIVE & FILL SOILS)
ABSORPTION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF)
= 413 SF
33% E.T.U. REDUCTION AREA REQ'D = 276 SF
ABSORPTION BED AREA PROWDED = 10 z30' = 300 SF
W►TH 2 LATERALS OF 4 H2O CHAMBERS
WASTEWATER SYSTEM FILL
MATERIAL NOTES
AFTER REMOVING ORGANICS TOPSOIL AND DEBRIS, PLACE SYSTEM
FILL OVER THE ENTIRE AREA OF PROPOSED ABSORPTION BED AND
TAPER AREA.
"ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY
SELECTED SAND OR SANDY LOAM WITH IN -PLACE PERCOLATION
RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3"
1N SIZE. LESS THAN 10% BY WEIGHT SHALL BE FINER THAN
0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE
IN THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 15% OF THE
MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE
ABSORPTION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED
TO PROVIDE MINIMUM OF 3-FEET BETWEEN BOUNDARY CONDITION
AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL
SHALL BE INSTALLED THROUGHOUT THE ABSORPTION BED AREA
AND TAPER AREAS.
ABSORPTION AREA SYSTEM FILL MATERIAL IS TO BE
MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT
PRIOR TO INSTALLATION OF ABSORPTION TRENCHES
INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF
SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE
SYSTEM MATERIAL SPECIFICATIONS
34" WIDE OPEN -BOTTOM GRAVELLESS CHAMBER
OPEN -BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH
CAPACITY.
HOUSE SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/4" PER FOOT
MINIMUM SLOPE.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/8" PER FOOT
MINIMUM SLOPE.
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION
FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT.
STABILIZATION FABRIC
STABILIZA71ON FABRIC TO BE WOVEN GEOTEX77LE KITH
POLYPROPYLENE YARNS, THRACE LINQ GTF--300 OR EQUIVALENT.
FILL MATERIAL
FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED
IN "FILL MATERIAL NOTES."
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORPTION FIELD
AREA. SEED AND ESTABLISH TURF.
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE
WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND
ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN
SEPTIC TANK LEACH FIELDS.
AFTER PLACEMENT OF SYSTEM FILL AND EXCAVATION OF 10' WIDE X 30' LONG
ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE
CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL
BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE
GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT
CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER
UNSUITABLE CONDITIONS PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT
SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTERPIPING
HAS BEEN INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON
THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110
GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME
WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR
EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS
WASTEWATER TREATMENT SYSTEM.
ROOF, F0071NG, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE
EXCLUDED FROM THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT
SURFACE RUNOFF AROUND ABSORPTION FIELD.
SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY TOWN
OF QUEENSBURY BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO
BACKFTLL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR
TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS
10'-0"
0. C. MAX.
36" FENCE POST DRIVEN
MINIMUM 16" INTO GROUND
-SILT STOP EMBED IN
GROUND 8" MIN.
_ ...:
..._.......
... ....
M
8 MIN. ,0
SECTION
p� ptBZSpECnVE�SOIL BACKF7LL
cam'
SEDIMENT CONTROL FENCE DETAIL
NTS
.STANMRD _SPFrTFTr.ATTONS FOR SILT FENCE
DEFINITION
A TEMPORARY BARRIER OF GE07EX71LE FABRIC INSTALLED ON THE CONTOUR ACROSS
A SLOPE TO INTERCEPT SEDIMENT LADEN RUNOFF FROM SMALL DRAINAGE AREAS OF
DISTURBED SOILS
PURPOSE
TO REDUCE RUNOFF VELOCITY & TO EFFECT DEPOS17ION OF TRANSPORTED SEDIMENT
LOAD.
APPLICATION
- MAXIMUM ALLOWABLE SLOPE LENGTHS CONTR16UIING RUNOFF TO THE FENCE
PLACED ON A SLOPE:
1:2 SLOPE (50%) 25 FT
1:3 SLOPE (33%) 50 FT
1:4 SLOPE (25%) 75 FT
1:5 SLOPE OR LESS 100 FT
- MAXIMUM DRAINAGE AREA FOR OVERLAND FLOW SHALL NOT EXCEED 1/4 ACRE
PER 100 FEET OF FENCE WITH MAXIMUM PONDING DEPTH OF 1.5 FEET.
- EROSION WILL OCCUR AS SHEET EROSION.
- CONCENTRATED WATER FLOW SHALL NOT BE DIRECTED TO FENCE.
DESIGN CRITERIA
- ALL SILT FENCES SHALL BE PLACED AS CLOSE TO 714E DISTURBED AREAS AS
POSSIBLE, W714 A MINIMUM OF 10 FEET FROM 714E TOE OF A SLOPE. THE AREA
BEYOND 714E FENCE MUST BE UNDISTURBED OR STABILIZED.
ROADWAY
4"
WOVEN STABILIZATION --J ABSORPTION BED
ROAD FABRIC STONE AGGREGATE
J
10' BED WIDTH
4' CHAMBER SPACING
INFILTRATOR H-20
CHAMBER PER PLAN
ABSORPTION FIELD SECTION
NTS
Ak 34" CHAMBER WIDTH
INFILTRATOR H-20
CHAMBER SECTION
36' FENCE POST NTS
SILT STOP EMBED IN
GROUND 8" MIN.
UNDISTURBED GROUND
— JtNJI11Vt AKtAJ IV t7t t'KVIt(:ItU d1 JILT ttNl.t MAIGC IYCCU
TO BE REINFORCED BY USING HEAVY WIRE FENCING FOR ADDED
SUPPORT.
- NMERE THE ENDS OF THE SILT FENCE COME TOGETHER, THE TWO
ENDS SHALL BE OVERLAPPED, ROLLED TOGETHER AND STAPLED
TO PREVENT SEDIMENT BYPASS AT THESE CONNECTIONS
FABRIC MATERIAL CRITERIA
GRAB TENSILE STRENGTH: 90 LBS AS7M 01682
ELONGA71ON AT FAILURE: 50% ASTM 01682
CONSTRUCTION SPECTRCATIONS
1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE
POSTS WITH WIRE TIES OR STAPLES POST SHALL BE STEEL
EITHER Or OR "U" TYPE OR HARDWOOD.
2. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE
FENCE WITH TIES SPACED EVERY 24' AT TOP AND MID SECTION.
FENCE SHALL BE WOVEN WIRE, 6" MAX. MESH OPENING
J. WHEN TWO SEC77ONS OF FILTER CL07H ADJOIN EACH OTHER
THEY SHALL BE OVER -LAPPED BY 6-INCHES AND FOLDED.
FILTER CL07H SHALL BE EITHER FILTER X, MIRAFI IOOX,
STABILINKA T14ON OR APPROVED EQUIVALENT.
4. PREFABRICATED UN175 SHALL BE GEOFAB, ENVIROFENCE OR
APPROVED EQUIVALENT.
5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL
REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE.
IMBER
HT
4" MIN. TOPSOIL,
SEED, MULCH &
ESTABLISH TURF
-8" MIN. I7EM-4 GRAVEL
SUBBASE COURSE
OEM
AI E h�I MEME ME11
=1Ia�1• ��= =1�z =1�z� =��-1
1m,=A—m B —,ME
—1---M�1B-- —1MEN =11� =11
111E 111111111 111111111 =
1
75' EFFECTIVE LENGTH
INFILTRATOR H-20 CHAMBER PROFILE
NTS
INSTALL
POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
1/4" PER FOOT 2"
MIN. SLOPE
4" PVC SCH-40 HOUSE SEWER
CHAMBER 1
SEDIMENTATION
CHAMBER
59"
CHAMBER 2
AEROBIC CONTACT
MA77ON CHAMBER
SA L COR UV DISINFECTION UNIT
ELECTRICAL JUNCTION
BOX W17H INDICATORS -
AND ALARM CONTACTS
LEVEL
4' PIPE
TREATMENT
PLANT
EFFLUENT
V
SECTION A -A III
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL SALCOR
ULTRAVIOLET
TREATMENT UNIT
1/8" PER FOOT
MIN. SLOPE
4" PVC SCH-40 EFFLUENT
28" DIA. POLY BASIN,
100 GAL
DISINFECTION
SUB - ASSEMBLY
HANDLE
FOR
REMOVAL
SUPPORT
FRAME & - -
GASKET
UV LAMP
QUARTZ BE &
TEFLON COVER
N07E: NOT ALL DIMENSIONS TO SCALE
SALCOR UV DISINFECTION UNIT
NTS
31.5"
1/8" PER FOOT
MIN. SLOPE
4" PVC SCH-40 EFFLUENT SEWER
TO INFILTRATOR CHAMBERS
FUJI CLEAN USA MODEL CE-5
ENHANCED TREATMENT UNIT
MAINTENANCE CONTRACT NOTE FUJI CLEAN ENHANCED TREATMENT UNIT & UV VESSEL DETAIL
A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM NTS
OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED
FOR SEMI-ANNUAL INSPECTION AND SERVICE OF THE
FUJICLEAN CE-5 ENHANCED TREATMENT UNIT.
WASTEWATER SYSTEM SETBACK SCHEDULE
PROPERTY LINE
WELL
WATERLINE
HOUSE
LAKE GEORGE
SEPTIC TANK, PUMP
STATION, FORCE MAIN,
EFFLUENT SEWER
10,
50'
10,
10,
SO'
ABSORPTION FIELD
10,
100,
10,
20'
100,
Dig (Safely.
New/,York
■ Cali Before You Dig
0 Wait The Required Time
E Confirm Utility Response
N Respect The Marks
® Dig With Care
800-962.7%2
www.digeafe"wyork.com
TAX MAP # 227.9-1-9
TOWN OF OUEENSBURY LOCAL BOARD OF HEALTH APPROVAL RESOLUTION - BOH 82, 2022
RESOLUTION APPROVING CARL AND'NUCHELE WEINER'S
NOW, THEREFORE, BE 1T
BE TT FURTHER,
APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES
I
RESOLVED, that
RESOLVED, that the Enhanced Treatment Unit (ETU} shall be maintained by the property
RESOLUTION NO.: BOii 82, 2Q22
owner in accordance with the manufacturer's recommendations for the life of the system, and
1. due to the nature of the variances, the Local Board of Health determines that the
INTRODUCED BY: Mr. Timothy McNulty
WHO MOVED ITS ADOPTION
variances would not be materially detrimental to the purposes and objectives of this
BE IT FURTHER,
Ordinance or other adjoining properties nor otherwise conflict with the purpose and
SECONDED BY: Mr. Anthony Metivier
objectives of any Town plan or policy, and
RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by
2. the Local Board. of Health finds that the. granting of the variances is necessary for the
certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review, and
WHEREAS, Carl and Michele Weiner (Applicants) filed an application for variances from
reasonable use of the land and are the minimum variances which would alleviate the
provisions of the Town of Queensbury On -Site Sewage Disposal Ordinance, Chapter 136 to install
specific unnecessary hardship found by the Local Board of Health to affect the
BE IT FURTHER,
a replacement septic system with the:
Applicants; and
RESOLVED, that this approval Resolution shall not be effective until 30 days after such
1. Absorption field to be located 63' from the shoreline in lieu of the required 100'
BE IT FURTHER,
notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park
setback,
Agency during such period.
2. Absorption field to be located I' from the westerly property line in lieu of the
RESOLVED, that the Local Board of Health hereby approves the application of Carl and
required10' setback;
Michele Weiner for variances from the Sewage Disposal Ordinance to install a replacement septic
Duly adopted this I day of October, 2022, by the following vote:
3. Effluent Sewer Line to be bated 4' from the westerlyproperty line in lieu of the
P P�3' �
systemwith the:
AYES : Mr. Feroie, Mr. McNulty, Mr. Strough, Mr. Metivier
required' 10' setback; and
4. House Sewer Line to be located 4' from the westerly property line in lieu of the
1. Absorption field to be located 63' from the shoreline in lieu of the required 100'
NOES :None
required 10' setback;
setback;
ABSENT: Mr. Freer
2. Absorption field to be located V from the westerly property line in lieu of the
on property located at 114 Rockhurst Road in the Town of Queensbury, and
required 10' setback;
!� BM �� Tom Ct�c of the Tom of tltreerebtitx WarrenCaft
b
3. Effluent Sewer Line to be located 4' from the westerly property line in lieu of the
New ft do hft ce* that i have iompamd the wish the
WHEREAS the Town Clerk's Office published the Notice of Public in the Town's
P H8 �
required l0' setback' and
forreping
above d a W _ '� �d� Q
o9� t n Board
of the Toum Board of the Towm of Que�sbory !� on e 1 -I+h day of
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
4. House Sewer Line to be located 4' from the westerly property line in lieu of the
ft.4Djp i 1- - 2022 at whlch a brio was pm9W and ttiat the
same is a cowl irans#t twatrorn and of the whole odpfiat thereat
variance requests on Monday, October 17a`, 2022, and
required 10' setback,
IN Wti M MR , t bw pereto set my hand W the SEAL. at sold Town
r ,2022
WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners
on property located at 114 Rockhurst Road in the Town of Queensbury and bearing Tax Map No:
within 500 feet of the subject property,
227.9-1-9, and
'$Memm
twatrY
TAX MAP # 22Z9-1-9
Dig 'p'F'
Safely.
New York
® Call Before You Dig
■ Wait The Required Time
■ Confirm Utility Response
® Respect The Marks
■ Dig With Care
800-962-7962
www.dig"feWmwyork.com
D
Split Rail Fence
CIRF
NEW 10'W x 3WL CRUSHED —�
STONE ABSORPTION BED W1T►i
(2) ROWS OF (6)- 34" WIDE TRAFFIC RATED
OPEN -BOTTOM GRAVELLESS CHAMBERS
I
One Story Wood
Frame House
A/C
}g J
�7
Concrete- Drive
<i
227.9-1-7
113 Rockhurst R-oa"d—
Lands of
Lorraine Dickinson
B:1161 P: 58
LAKE WATER
SUPPLY
" NEVd 4" PVC SCH-40 -
HOUSE SEWER
2% MIN. SLOPE
C)
Lands N/F of
Lambert's Landing LLC
8:5023 P:173 LAKE WATER
227.9-1-8
SUPPLY
CIRF
NM17 _�
°`� S 79'00'00" E
s'c*�,
N �
p
CIRF _
=
,64.00'
6''
Shed
12" Spruce
63 All)ABS
E4.
t o
SIN
N
227.9-1-�9
1
—" -10'
I
� '
114 Rockhurst Road
28" He lock
"'
PT-1
® �
� Lands of
� Deck
r .a Carl 8c Michele Weinbr ' _ VERTICAL DATUM
TP-1 Z °0 B: 4226 P: 265;?�
NORTH AMERICAN VERITCAL DATUM OF 1929 (NGVD29)
c AArea
1415` 6.2 Sq. Feet
0.N Acres I I I
F , � I
(n
LANK WATER I 0.)
SOPPLY t 0
y � 1
o ; = 4i
O
Fireplac I ; -
v_ ] NEW 4" PVC SCH-40
EFFLUENT SEWER
y; NEW 28" POLY BASIN
4� W I RISER FOR UV UNIT
�Playhous-
I NEW NORWECO
` d� ENHANCED TREATMENT UNIT j
NEW V1 PVC SCH-40
HOUSE SEWER r• t
6
y t
'
1 i � ✓^"� � � Y � t i
F 4 € ;
}
t t i
1 ; %
III i
;;Ii Si
fF 332.99ke �J
' �,= j A a
._. ? 21
ii}S i?'t i ..
'. G F :. 3 j:=. " NEW 4 PVC SCH-40
" HOUSE SEWER {
Si
c 1
1 "NA,
F Retainincf Wall
Lake
George
i=
F2 SF i, i FF=328.04.0 Cone eW te alk < j
<
V.
Covered
1 1 F S .��f: YYY ti tl I
Dock
,"0,
� r
F�I 1 W I
�"0 10
Ramp _
Shed
\ .
-1� I € I
x° t S�I
I
5 �;
01
y.
' 1 NEW 4" PVC SCH-40 t t
a
U HOUSE SEWER
44' IM�ape
WL WL WL WL L WL I W WL WL WL
0
1
i � }
1F 1' � 4" apl LAKE WATERINTAKE
I APPROXIMATE LOCATION
Concrete
`\' ( 24" Hem
t �
q
o
30" Hemloc I
1 e»
4" PVCSCH-40 � ' 10' P.L. SETS G
CLEAN-OUT\
�TOGRADE(T(P) Propane Tanks;. ,.
�' _= 12" Helock ;
1 o enerato
2 F I 4 i i 4 Fy
1�
1F ii
NM 6
@
�'
Stockade Fern e
Stockad Fence
ry
/ / Q%
1
"".
f +>
�
#
227.9-1-6 CIRS
St 1
•
N 79'00'00" W
Nail Set in Root 10'f
111 Rockhurst Road
1
227.9-1-10
/o
"� s
Lands N/F of
- i 1z 1 �; '
i1 �'ii�
112 Rockhurst Road
John & Carolyn Swan
y
F,2
� � F � "'A, A
Lands
N/F of
8:5107 P:35
F. ���:`
Garage Eric K
Cottrell
LAKE WATER
B:1441
P:102
SUPPLY
LAKE WATER
SUPPLY
WASTEWATER SYSTEM PLAN
SCALE: 1 "=10'
GRAPHIC SCALE
5 0 2.5 5 10 20
IN FEET )
SEPTIC VARIANCE SUMMARY
NYSDOH APPENDIX 75 A WASTEWATER TREATMENT STANDARDS
TABLE 2 SEPARATION REQUIREMENTS
1. ABSORPTION FIELD TO SHORELINE
100' REQUIRED
63'PROPOSED
37OF RELIEF REQUESTED
2. ABSORPTION FIELD TO WESTERLY PROPERTY LINE
10' REQUIRED
1'PROPOSED
9' OF RELIEF REQUESTED
3. EFFLUENT SEWER LINE TO WESTERLY PROPERTY LINE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
4. HOUSE SEWER LINE TO WESTERLY PROPERTY LINE
10' REQUIRED
4'PROPOSED
6' OF RELIEF REQUESTED
SITE SOILS DATA
TEST PIT
TP-1 - 8110122 BY: T. HUTCHINS, P.E.
AREA OF PROP. ABSORPTION FIELD
0-4" TOPSOIL/GRASS
4-60" MIXED SAND & CONCRETE & BRICK
DEBRIS FROM OLD H07EL
NO BOUNDARY COND177ON ENCOUNTERED
PERCOLATION TEST
PT-1 - 8110122 BY: T. HUTCHINS, P.E.
STABILIZED PERCOLA77ON RATE: 4 MIN/IN
IN BLENDED NA77VE AND FILL MATERIAL
SITE LOCATION LOCATION MAP
RECORD DRAWING NOTE:
A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE
DURING CONSTRUCTION AND IT IS MY OPINION THAT
THE SYSTEM IS INSTALLED IN GENERAL CONFORMANCE
WITH THE APPROVED PLAN AND THIS RECORD
DRAWING FINAL SURFACE FINISHING AND TURF
ESTABLISHMENT IS ONGOING.
G. THOMAS HUTCHINS, P.E.
1112212022
Dig "Safely.
New I York
IfflCall Before You Dig
® Wt •Th R ' d T•
T
s
Mr
NEIGHBORHOOD MAP SITE LOCATION
INSTALLATION DATE: 1112212022
INSTALLED BY - ELLSWORTH & SON EXCAVATING
TAX MAP # 227.9-1-9
ai a equire ime
®Confirm Utility Response
2
RECORD DRAWING
1
ADDED APPROVAL RESOLUTION (SHEET S3) — ISSUED FOR PERMIT
®Respect The Marks
®Dig With Care
0
ISSUED FOR SEPTIC VARIANCES
8 0 0— 9 6 2— 7 9 6 2
www.digsafelynewyork.com
No.
Revisions
WASTEWATER SYSTEM PLAN
-c OF N
MAP REFERENCE:
BASE MAP INFORMATION FROM "MAP OF A SURVEY
��� ON
prepared for. -
MADE FOR CARL AND MICHELE WEINER, IN THE
or
Carl & Michele Weiner
TOWN OF QUEENSBURY, WARREN COUNTY, NEW
i r~
YORK. DATED FEBRUARY 1, 2022. PREPARED BY.-
rnn 7'/,F
114 Rockhurst Road
Town of Queensbury, County of Warren, State of New York
it D u S e
�w�
® o
Drawn: JRS/LWD/WGC
Checked: GTH
Scale: NOTED
Date:
n
��vv
e V e s
eo �
6
�Qc, 79
169 Haviland Road
T A s
1112312022
10 20 2022
911512022
Date
4=Zl L1Y°V@370Y'S
ALTERATION OF T IS DOCUMENT EXCEPT
Queensbury, NY 12804
292001-01
169 Haviland Road Queensbury, New York 12804
BY A LICENSED PROFESSIONAL ENGINEER
(518) 745-0307 Phone
-S1
(518) 792-6474 New York Lie. No. 50135
1IS A VIOLATION OF NYS EDUCATION LAW.
Hutchins Engineering PLLC (518) 745-0308 Fax
WASTEWATER SYSTEM DESIGN
3—BEDROOM RESIDENCE
WATER SAVING FIXTURES
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW — 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 330 GPD
PRETREATMENT TANK — FUJICLEAN MODEL CE-5 E.T.U.
DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON
6-7 MIN/IN PERCOLATION RATE
(BLEND OF NATIVE & FILL SOILS)
ABSORPTION BED AREA REQ'D = (330 GPD)/(0.8 GPD/SF)
= 413 SF
339 E.T.U. REDUCTION AREA REQ'D = 276 SF
ABSORPTION BED AREA PROVIDED = 10 z30' = 300 SF
WITH 2 LATERALS OF 4 H2O CHAMBERS
WASTEWATER SYSTEM FILL
MATERIAL NOTES
AFTER REMOVING ORGANICS TOPSOIL AND DEBRIS, PLACE SYSTEM
FILL OVER THE ENTIRE AREA OF PROPOSED ABSORPTION BED AND
TAPER AREA.
"ABSORPTION AREA SYSTEM FILL" MATERIAL SHALL BE CAREFULLY
SELECTED SAND OR SANDY LOAM WITH IN —PLACE PERCOLATION
RATE OF 3-6 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3"
IN SIZE. LESS THAN 107. BY WEIGHT SHALL BE FINER THAN
0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE
IN THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 151'. OF THE
MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE.
ABSORPTION AREA SYSTEM FILL MATERIAL SHALL BE INSTALLED
TO PROVIDE MINIMUM OF 3—FEET BETWEEN BOUNDARY CONDITION
AND BOTTOM OF ABSORPTION BED. ONLY SYSTEM FILL MATERIAL
SHALL BE INSTALLED THROUGHOUT THE ABSORPTION BED AREA
AND TAPER AREAS.
ABSORPTION AREA SYSTEM FILL MATERIAL IS TO BE
MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT
PRIOR TO INSTALLATION OF ABSORPTION TRENCHES
INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF
SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE.
SYSTEM MATERIAL SPECIFICATIONS
34" WIDE OPEN -BOTTOM GRAVELLESS CHAMBER
OPEN —BOTTOM CHAMBERS TO BE INFILTRATOR H-20 HIGH
CAPACITY.
HOUSE SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 114" PER FOOT
MINIMUM SLOPE.
EFFLUENT SEWER PIPE
PIPING TO BE 4" SCH-40 PVC. INSTALL WITH 1/8" PER FOOT
MINIMUM SLOPE.
ABSORPTION BED AGGREGATE
STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE.
FILTER FABRIC
FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION
FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT.
STABILIZATION FABRIC
STABILIZATION FABRIC TO BE WOVEN GEOTEXTILE WITH
POLYPROPYLENE YARNS, THRACE L1NQ GTF-300 OR EQUIVALENT.
FILL MATERIAL
FILL MATERIAL TO BE GRANULAR LOAMY SAND AS DESCRIBED
IN "FILL MATERIAL NOTES."
TOPSOIL
PLACE 4" MINIMUM TOPSOIL OVER ENTIRE ABSORPTION FIELD
AREA. SEED AND ESTABLISH TURF.
SYSTEM INSTALLATION NOTES
CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE
WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND
ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN
SEPTIC TANK LEACH FIELDS.
AFTER PLACEMENT OF SYSTEM FILL AND EXCAVATION OF 10' WIDE X 30' LONG
ABSORPTION BED TO THE DEPTHS REQUIRED, THE WALLS AND FLOOR SHALL BE
CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL.
PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL
BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE
GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE.
THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT
CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER
UNSUITABLE CONDITIONS. PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES.
ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT
SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD.
DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING
HAS BEEN INSTALLED.
THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON
THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110
GPO PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME
WATER USE FIXTURES, SUCH AS JACUZZI—TYPE SPA TUBS OR WATER TREATMENT
EQUIPMENT THE INSTALLATION OF NON —CONSERVING WATER FIXTURES OR
EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS
WASTEWATER TREATMENT SYSTEM.
ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE
EXCLUDED FROM THE WASTEWATER SYSTEM.
CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT
SURFACE RUNOFF AROUND ABSORPTION FIELD.
SEPTIC TANK, PUMP STATION & ABSORPTION BED MUST BE INSPECTED BY TOWN
OF QUEENSBURY BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO
BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR
TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS.
10'-0" 36" FENCE POST DRIVEN
O.C. MAX. MINIMUM 16" INTO GROUND
SILT STOP EMBED IN
GROUND 8" MIN.
STANDARD SPECIFICATIONS FOR SILT FENCE
DEFINITION
A TEMPORARY BARRIER OF GEOTEXTILE FABRIC INSTALLED ON THE CONTOUR ACROSS
A SLOPE TO INTERCEPT SEDIMENT LADEN RUNOFF FROM SMALL DRAINAGE AREAS OF
DISTURBED SOILS.
PURPOSE
TO REDUCE RUNOFF VELOCITY & TO EFFECT DEPOSITION OF TRANSPORTED SEDIMENT
LOAD.
APPLICATION
— MAXIMUM ALLOWABLE SLOPE LENGTHS CONTRIBUTING RUNOFF TO THE FENCE
PLACED ON A SLOPE.
1:2 SLOPE (507.) 25 FT
1:3 SLOPE (33%) 50 FT
1:4 SLOPE (259a) 75 FT
1:5 SLOPE OR LESS 100 FT
— MAXIMUM DRAINAGE AREA FOR OVERLAND FLOW SHALL NOT EXCEED 1/4 ACRE
PER 100 FEET OF FENCE WITH MAXIMUM PONDING DEPTH OF 1.5 FEET.
— EROSION WILL OCCUR AS SHEET EROSION.
— CONCENTRATED WATER FLOW SHALL NOT BE DIRECTED TO FENCE.
DESIGN CRITERIA
— ALL SILT FENCES SHALL BE PLACED AS CLOSE TO THE DISTURBED AREAS AS
POSSIBLE, WITH A MINIMUM OF 10 FEET FROM THE TOE OF A SLOPE. THE AREA
BEYOND THE FENCE MUST BE UNDISTURBED OR STABILIZED.
ROADWAY
36" FENCE POST
SILT STOP EMBED IN
GROUND 8" MIN.
UNDISTURBED GROUND
wl
— SENSITIVE AREAS TO BE PROTECTED BY SILT FENCE MAYBE NEED
TO BE REINFORCED BY USING HEAVY WIRE FENCING FOR ADDED
SUPPORT
— WHERE THE ENDS OF THE SILT FENCE COME TOGETHER, THE TWO
ENDS SHALL BE OVERLAPPED, ROLLED TOGETHER AND STAPLED
TO PREVENT SEDIMENT BYPASS AT THESE CONNECTIONS.
FABRIC MATERIAL CRITERIA
GRAB TENSILE STRENGTH : 90 LBS ASTM D1682
ELONGATION AT FAILURE: 507. ASTM D1682
CONSTRUCTION SPECIFICATIONS
1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE
POSTS WITH WIRE TIES OR STAPLES. POST SHALL BE STEEL
EITHER "T" OR "U" TYPE OR HARDWOOD.
2. FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE
FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION.
FENCE SHALL BE WOVEN WIRE, 6" MAX. MESH OPENING.
3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER
THEY SHALL BE OVER —LAPPED BY 6—INCHES AND FOLDED.
FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI 100X,
STABILINKA T140N OR APPROVED EQUIVALENT.
4. PREFABRICATED UNITS SHALL BE GEOFAB, ENWROFENCE OR
APPROVED EQUIVALENT.
5. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL
REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE.
—10' BED WIDTH-
4' CHAMBER SPACING
4"
ABSORPTION FIELD SECTION
NTS
34" CHAMBER WIDTH
INFILTRATOR H-20
CHAMBER SECTION
NTS
IMBER
HT
4" MIN. TOPSOIL,
SEED, MULCH &
ESTABLISH TURF
-8" MIN. ITEM-4 GRAVEL
SUBBASE COURSE
75" EFFECTIVE LENGTH
INFILTRATOR H-20 CHAMBER PROFILE
NTS
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
1/4" PER FOOT
MIN. SLOPE
4" PVC SCH-40 HOUSE SEWER
59"
2"
CHAMBER 1 CHAMBER 2
SEDIMENTATION NAEROBIC CONTACT
CHAMBER �,LTRAT[ON CHAMBER
I�lrl�d�� l��L�1C�1_•� R�Ir1���L�7
ENHANCED TREATMENT UNIT
MAINTENANCE CONTRACT NOTE
A MAINTENANCE AND SERVICE CONTRACT BETWEEN SYSTEM
OWNER AND MANUFACTURER'S REPRESENTATIVE IS REQUIRED
FOR SEMI-ANNUAL INSPECTION AND SERVICE OF THE
FUJICLEAN ENHANCED TREATMENT UNIT.
AEROBIC C
FILTRA71ON
I
INSTALL POLYETHYLENE EXTENSION
TO GRADE WITH TAMPER
RESISTANT ACCESS COVER
(NON -TRAFFIC AREAS)
INSTALL NORWECO
ULTRAVIOLET
TREATMENT UNIT
1/8" PER FOOT
MIN. SLOPE
4" PVC SCH-40 EFFLUENT SEWER
28" DIA. POLY BASIN,
100 GAL
NTS
31.5"
1/8" PER FOOT
MIN. SLOPE
4" PVC SCH-40 EFFLUENT SEWER
TO INFILTRATOR CHAMBERS
FUJICLEAN ENHANCED TREATMENT UNIT & UV VESSEL DETAIL
NTS
wM10109
. &,"
EM Call
Before You Dig
Wait The Required Time
Confirm Utility Response
Respect The Marks
Dig With Care
800-962-7962
www.digsafelynewyork.com
TAX MAP # 227.9-1-9
RESOLUTION APPROVING CARL AND MICHELE WEINEWS
NOW, THEREFORE, BE IT
BE IT FURTHER,
APPLICATION FOR SANITARY SEWAGE DISPOSAL VARIANCES
RESOLVED, that
RESOLVED, that the Enhanced Treatment Unit (ETU) shall be maintained by the property
RESOLUTION NO.: BOH 82, 2022
owner in accordance with the manufacturer's recommendations for the Iife of the system, and
1. due to the nature of the variances, the Local Board of Health determines that the
INTRODUCED BY: Mr. Timothy McNulty
WHO MOVED ITS ADOPTION
variances would not be materially detrimental to the purposes and objectives of this
BE IT FURTHER,
Ordinance or other adjoining properties nor otherwise conflict with the purpose and
SECONDED BY: Mr. Anthony Metivier
objectives of any Town plan or policy; and
RESOLVED, that the Town Board authorizes and directs the Town Clerk to forward by
2. the Local Board of Health finds that the granting of the variances is necessary for the
certified mail a certified copy of this Resolution to the Adirondack Park Agency for its review, and
WHEREAS, Carl and Michele Weiner (Applicants) filed an application for variances from
reasonable use of the land and are the minimum variances which would alleviate the
provisions of the Town of Queensbury On -Site Sewage Disposal Ordinance, Chapter 136 to install
specific unnecessary hardship found by the Local Board of Health to affect the
BE IT FURTHER,
a replacement septic system with the:
Applicants; and
RESOLVED, that this approval Resolution shall not be effective until 30 days after such
1. Absorption field to be located 63' from the shoreline in lieu of the required 100'
BE IT FURTHER,
notice to the Adirondack Park Agency and shall be subject to review by the Adirondack Park
setback;
Agency during such period.
2. Absorption field to be located 1' from the westerly property line in lieu of the
RESOLVED, that the Local Board of Health hereby approves the application of Carl and
required 10' setback,
Michele Weiner for variances from the Sewage Disposal Ordinance to install a replacement septic
Duly adopted this 17u' day of October, 2022, by the following vote:
3. Effluent Sewer Lane to be located 4' from the westerly property line in lieu of the
system with the:
AYES : Mr. Ferone, Mr. McNulty, Mr. Strough, Mr. Metivier
required 10' setback; and
4. House Sewer Line to be located 4' from the westerly property line in lieu of the
1. Absorption field to be located 63' from the shoreline in lieu of the required 100'
NOES :None
required 10' setback;
setback;
ABSENT: Mr. Freer
2. Absorption field to be located V from the westerly property line in lieu of the
on property located at 114 Rockhurst Road in the Town of Queensbury, and
required 10' setback;
3. Effluent Sewer Line to be located 4' from the westerly property line in lieu of the
r, Betty Murphy, Deputy Town Clerk of the Town of e Warren County,
Hew York, do hereby certify that 1 have compared the fore g e foregoing with the
WHEREAS, the Town Clerks Office published the Notice of Public Hearing in the Towns
required 10' setback; and
original resolution as rested above adopted at a ICLI ,rr meeting
of the Town Board of the Town of Queensbury held on e 1 � day of
official newspaper and the Local Board of Health duly conducted a public hearing concerning the
4. House Sewer Line to be located 4' from the westerly property line in lieu of the
(DL+D(©{ eV— 2= at which a quorum was present and that the
same is a correct transcript therefrom and of the whole original thereof
variance requests on Monday, October 17cn , 2022, and
required 10' setback;
to date,
1N WITNESS THEREOF I lave hereto set my hand and the SEAT. of said Town
of Queensbury; this 1gVh fiat of f cft)to .r , 2022
WHEREAS, the Town Clerk's Office has advised that it duly notified all property owners
on property located at 114 Rockhurst Road in the Town of Queensbury and bearing Tax Map No:
. -
within 500 feet of the subject property,
227.9-1-9, and
, SEAL SIGNM
_ Betty Murphy
Deputy Town lell t
- TM Of QUee
TAX MAP # 227.9-1-9
EM Call Before You Dig
Wait The Required Time
® Confirm Utility Response
• Respect The Marks
® Dig With Care
800-962-7962
www.digsafelynewyork.com