Loading...
98-600 T _..... ..: .. .r... . _. . ..:. . ... . CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YO►RK April 16 99 Date 19 98600 'Thiel is to certify that work requested to be done as shown by Permit No. has been completed. COMMERCIAL ADDITIONS ( EXPAND SNACK This structure may be occupied as a 1035 STATE ROUTE 9 i ncation S KATELAND Ck ner TAX. MAP NO . 7 3 . - 1 - 8 . 3 By Order Town Board [ OWN p8 QUEEN �r� � Director of Bldg. & Code Enforcement BUILDING PERMIT VALUE $ 5000 TOWN OF +QUEENSSURY NQ . g 600 TAX MAP NO . 73 . — 1 - 8 . 3 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to SKATELAND OWNER of property located at 1035 STATE ROUTE 9 Street, Road or Ave. in the Town of Oueensbury, To Construct or place a COMMERCIAL BAR at the above location in accordance to app{ication together with pint plans and other information hereto filed and ith the Town of Queensbury Building and Zoning Ordinance. approved and in compliance w t. OWNERS Address is 1035 STATE ROUTE 9 QUEENSBURYr NY 12804 2. CONTRACTOFt or 8Ul1IRS Name MI L�LgER ,fit J�IgM p� q, I 3 C �i;S]1.�Ie: t7li�'I-I t�OAU DIAMOND POINT , NY i. ARCHITECT'S Name 5, ARCHITECT'S Address 6. TYPE of Conswuction _ {Please indicaxe by Xl COMMERCIAL ADDITION f f Wood Frame f ) Masonry { I Steel I I 7. PLANS end 5p04fiost'Ons 2 CO�RCIAL ADDITIONS AS PER PLOT PLAN SPECIFICATIONS a. proposed Use COMMERCIAL ADDITIONS ( EXPAND SNACK BAR 200 September 30 2000 PERMIT FEE PAID -- THIS PERMIT EXPIRES 19 11f inspector of the a loges+ Period is required an application for an 0xxention must be made to the Huildigp and 2onir+y town of C mwnslwry before the expiration d 30I September 1998 Dated at the Town of Queensbury this Day of t9 for the Town of Oueensbury SIGNED BY BuifdMq and oninp inspects+ Building Permit Applicatio Town of Queensbul'y - Dept. of Community Develvmnent, 742 Bay Read, Quern bury, NY 12804 1761-82.561 BUILDING & CODE ENFORCEMENT NOTICERequirements prior to issuance of this permit; PERMIT FILE NO. `} A permit crust be obtained before , .- beginning constriction. No inspections PERMIT FEE PAID $ will be made until applicant has received ZoningBoardctioCt a VALID BUILDING PERMIT. All Area f Use RECREATION FEE PAID $ applicants` spaces on this application MUST be completed and the signature Q Marmin,g Board Actipu, REVIEWED BY.- of the applicant must appear on the SPR I Subdivision f Other suflding lnspecrnr @EELhcafton form. 7hank ,� _ Recreation Fee Payment Applicant: x- a . a-d G •�. f1 /yl +IJS -� d Owner: �} Address: + /f`d�� ' [ .�"r7 } l Address; G- - ai,47e /ems phone # � 1/? y _ -�c^ : Phone # Property Location: r" ¢"L�' 'T '/_J. I �; Tax Map Number _ Subdivision Name: Section Block T i,t NATURE OF PROPOSED WORK : ESTIMATED MARKET VALUE OF THE New Building : CONSTRUCTION : $ residence / commercial Addition to -Buildi � � residence / commerca_a OCCUPANCY INFORMATION : Alteration to Hui ng : Primary Building - residence / commercial Single Family Dwelling Residence / Commercial Two Family Dwelling no change to exterior size Family Dwelling Office Other Work ( describe below ) Mercantile &EP Manufacturin ? Other GROSS AREA. OF PROPOSED STRUCTURE : If ADDITION , what will use let Floor . 5 d� . sq , ft . of new addition b ? : sq . ft . . Other Floors . , , , sq , ft , ( neat unfinished cellar or basement ) ACCESSORY BUILDINGS : Detached Garage 1 , 2 cap' TOTAL FLOOR AREA : tffap� SQ • FT . Attached Garage 11 2 car Private Storage Building S i ZE OF NEW STRUCTURE : Commercial Storage Building Other FEET X Z FEETr� Foundation Type : PCrfti/4i-y (bv0,e;c Will any second-hand or ungraded Number of Stories : lumber be used ? If so , for what ? ( habitable space only ) it Height ( grade to ridge ) : + /49 feet TYPE OF HEATING SYSTEM : Number of fireplaces and/or w0000c stove ( circle all which lies ) to be installed - AO Electric / Oil / Gas Wood Forced Hot Air / seboard / Other person resporisibl.e. for su ervisio of work as a ds to building p reg codes i s : .7,rx] /1�I � !.S" �'1L-d-�`" .��i` ,L�i./�,.���� Name Addr+es ss PWone Builder : Plumber : Masan : Electrician : DECL RA77ON Please sign below after you have carefully read the statement. To the best of my knowledge the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work: shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit prior to a Certificate of Occupancy-'or Certificate of Compliance being issued, an AS BUILT PLOT PLAN by a licensed surveyor; drawn to scale, showing actual location of project on premises- Signature: (owner, owner's agent, architect, contractor) t _ COMMERCIAL FINAL INSPECTION REPORT Building & Code Enforcement Date inspmuon request received: Office No. (518) 161-8256 Dept. of Community Development . -- Town of Queensbury Arriv �` " apa 742 Bay Road Inspector's Initials Queensbury, NY 12804 CD PERMIT # NAME DATE LOCATION TYPE OF STRi3CT ;LE N/A YES NO COMMENTS ChimneyP'l3" V location Plcunbing Vent Roof Carrsplaw Exterior finish grade comp lmerior/exterior guardrails in. pl aranhde cs lnterior/extmior ballasters 4 . spa &platform/dedcs Stair handrail 34 in. - 38 in. - Step risers 7 3/4 in _ Main door'' in. All others 3 Lever handles Fxhs at grade or p orm Canopy to cover req. (!as valve shut-off exposed & r lator (IS in.) above Fkaor bathroom watcedght other floors okay Hot water relief valve Bodertfiunace enclosure <250.000 BTU N/R 250,000 13-1-U to 1,000.o o aru,s 1 hour)—_ > 1,000.000 BTU's (2 hour)_ Cras furnace shut of Within 30 IL or within line of site Oil furnace shut off at ontruncc to furnace area_ Stockroom enclosure ( 1 hour). %hour door Storagwrece ving/shipping room (2 hour), 1 '/2 doors 1 ' x hour doors and closers * . hour corridor doors and closers_, Firewallslftre separation, 2 hour, 3 hour complete Fire dan3pers. 2 hour fire walk/separation or greater Fire door/shutLcr% 1 1/2 hour, 3 hour Ceiling fire stopping 3,000/5,000 sq. ft-_ _-- Fan shutdown, smoke vents or fan ExA door/panic bars assembly hardware_—. _ Elevators��__ Eievatorsignagef Handicapped bathroom grab_barsisirks/toilets. — Handicapped bath/parking kot signage Handicapped service counters 34 in., checkout 36 in. Handicapped rarnp/handraife continuous/ 12 in. beyond .Naive f ist+eni ng systerrr and sigiage assembly space Final Eiect"Cal __ Site P1anJVanance required.- ,-- - Final Survey, new structures.—. �- -as-buih septic system layout required___--- 01cav to issue terrtp. C/O (CAXA il'. of Occarpancy)_� C&av to issue pefrnanc:rt C/U (Certif. of ocet fancy) Crkav to issue C/C (CACrtif. of Compliance) North leld Desigii 15 Olde Coach Road , Diamond Point , N.Y. 12824 phone 518 - 668 - 3155 March 24, 1999 Mr. David Hatten Town of Queensbury Building Department Queensbury , NY Re: Skateland Renovation Project Route 9 Queensbury, NY Dear Sir, During the construction of the above referenced project, The owner has altered from the Northfield Design construction drawings in the two areas that follow: 1 . The detail for attachment of the wood truss to the angle support has been altered to include a gusset plate at each truss with a bolted attachment. This is in lieu of the wood blocking and nailed attachment shown on our drawings. I feel that this revised connection detail is satisfactory. 2. The detail of attaching the pressure treated top plate to the concrete bond beam at the top of the block wall has been altered. In lieu of bolting the plates to the t(rof the wall , the Owner has power shot the plate to the concrete at a closer increment (12-18 inches on center). Although I prefer to bolt this connection, the method utilized on the project in conjunction with the number of connectors utilized will meet the design criteria for this connection. I trust this letter will satisfy your needs to close out the project for a Certificate of Occupancy. Please do not hesitate to contact my office if I can be of any further assistance in this matter. Sincerely, James E. Miller Northfield Design architects & planners cc: Skateland Enterprises Inc. a CO FIRE MARSHAL TOWN OF QUEENSBURY QUEENSBURY, NY 12804 (S18) 761 -8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME - LOCATION _ PERMIT # SCHEDULE INSPECTION ON /J) PM III"' APPROVED NIA YES NO EXITS �r -- AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING - - FIRE EXTINGUIS ERS _-- - � __.._ ✓ FIRE ALARM SYS M FIRE SPRINKLER SYST. FIRE SUPPRESSION SYS - .-- HOOD INSTALLATION _----- - j INTERIOR FINISHES _ - ---- - -� - - STORAGE: - ------ ! CLEARANCE T SPRINKLERS --- CLEARANCE T HEATING UNIT i REQUIRED SIGNAGE -. --- - - - - CHIMNEY WOOD STOVE --- FIREPLACE [MASONRY ❑ FACTORY BLT, FtOUG- HAN --- Q FINAL - OK TO THIS DATE REMARKS: INS EGTOR INSF'Sl-IP.PIIB GENERAL LN.� Ems' Nr REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road Queensbury, NY 12804 Arriwe Inspector's p or*�PIrd . _ NAME: PERMIT LOCATION: DATE : TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS FootingslPiers Monolithic Pour Form Reinforcement in Plane The ntractor is ble for pro�vi pro n from fireez' for 48 ho cement of the con te. Materials for this purpose on site Foundation/WallPour Reinforcement in Place Fo tion/Dampproofin 1t,. ack Approval Plumbing Under Slab Plumbing vent/Vents in Place Rough Plumbing Hearing Rough-In Unsulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Franun Jack Studs/Headers Bracing/13 idgin Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour _ Firestappin GE2VER4L IN, PECT�CIN REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive am/pm Depart pm 94en Inspector's Initials NAME' PERMIT #LOCATDATE TYPE O RECHECK NIA YkISNO COTS Monolithic Pour Form Reinforcement in Place :Ie The contractor is responsi forproviding protection fromeezin for 48 hours following the pla ent of the concrete. Materials for this on Foundation/ Wall Reinforcement Mi Place FoundaUonlDampp Backfill Approval Plumbing Under Sl Plumbing all is in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R.- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framin Jack Studs/Headers Bracing/Bridging, Joist Hangers Jack posts/Main Beam Air Infiltration Barrier Fire Separation 1, 27 3, hour Penetration Sealed Fire 'Wall 2, 31 4 hour Firestoppin GENERAL iNSP.ECTIQ7lV RT Town of Qaeensbury Dept, of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Read Queensbury, NY 12804 Arrive C, - ., Ina t:a: pit als NAME: PERlir #Vi TL7CATION: DATE TYPE OF STRUCTURE: RECHECK NIA YES NO 'C=c= TT'S FootingslPiers Monolithic Pour Form Reinforcement in Place The contractor is le for providing peon fro freezitr for 48 hours following. th t of the concrete. Materials for this purpose Foundation/Wallpour Reinforcement in Puce Foundation/Dampproofing Ba kfill Approval Plumbing Under Slab Plumbing VentlVents in Place Rough Pl Heating Rough-In insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- P�r Ven Attic ent Frarnin - F SQc�r 1 art- - V""�V Jack. StudslHeaders ✓ �'t`' GP+ s Bracing/Bridgin l_i 4� -A � 7 ► t Q� Joist Hangers Jack Posts/Nlain Beam Air Infiltration Barrier, Fire Separation 1, 29 3, hour "z-x \A 6� Penetration Sealed L1 F,\' Fire Wall 2, 31 4 hour [� y {�- G1h +�� c'��� C - '- i ► „� Firestoppin GENERAL INSFECTI(i1V REPORT Town of Queensbury "`••• Dept, of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive Oft am/pffn Depart n Inspector's Initials; 17) : PERMIT # 9� o NAME LdCATIdN: DATE : I [7 _ TYPE OF STRUCTURE: RECHECK _ N/A YES NO COMMENTS Footings/Piers � Monolithic Pour Form / Reinforcement in Place The contractor is respansib for providing protection from ing Fire. 44�v if d(4j, I L 714ewe^ 41 for 48 hours following the plac ent of the concrete. Materials for this purpose on site FoundationfWallpour Reinforcement in Place FoundationlDamppr�oofiin BackGll Approval E'k' �' lc1r �' /�/ °"j ''^'� Plumbing, Under Slab Plumbing Vent[Vents in Place Rough Plumbin Heating Rough4n Insulation Foundation Walls Interior R. Foundation Walls Exterior R- Floors R- Walls R- C'.eiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent ---- Framing Jack Studs/Headers Bracing/Bridging, Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1 , 2, 3, !tour Penetration Sealed Fire Wall 2, 3, 4 hour, Firestoppin � U%0 GENERAL IN PE N REEPRT - Town. of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road _ PM Queenslwry, NY 12804 Arrive am/pmIns Depart )(ngpeCtllr's Initials NAME: PERMIT # M LOCATI(3N: DATE : - 1 TYPE OF STRUCTURE: RECHECK NIA YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The retractor is responsible for �f Provi 4 1e" mg for 48 hours following placement of the it Materials for this on site FoundationlWallpo Reinforcement in Place Foundation/Damppro ofm �ackfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In insulation Foundation Walls Interior R- Foundation Wails Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framin Jack Studs/Headers Bracing/Bridgin Joist Hangers jack Posts/Main Beam Air Infiltration Barrier Fire Separation. 1, 21 3. hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping. GENERAL LNS CT'IUN REPO R Town of Queensbury Dept. of Community Development Date inspection west received: Building & Code Enforcement 742 Bay Road , r Queensbury, NY 12804 Arrive'Z'0�7 :+, -�P� Inspector's Init NAME: PERMIT # LOCATION: DATE : TYPE OF STRUCTURE: RECHECK NIA YES NO CON4NMNTS FootingstPiers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours follgwing the placement of the concrete. Materials for this se on si Foundation/Wallpoeu Reinforcement in Place Foundation/Dampproo Backfill Approval. Plumbing Under ab Plumbing Ventf Vents in Place Rough Plurnbin Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- E]nict work or piping in unheated spaces R- Proper Vent, Attie Vent Framin Jack Studs/Headcrs Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3. hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTI[7N REPORT Town of Queensbury Dept of community Development Date inspection request received: Building & Code Enforcement 742 Bay Read r--' Queensbury, NY 12904 Arrive r Depart Pector'0 L°itials NAME: �� PERMLT # LOCATIO J�ATE : TYPE OF STRU 0: RECHECK N/A YEs NO CON DENTS 00 n, em Monolithic Orin vtteinforcement in The contractor is ie for providing protection g for 48 hours follo g the p of the concrete. Materials for this on site Foundation/Wallpour Reinforcement in Place FoundationlUarnpproofin Backfill Approval Plumbing Under Stab Plumbing Vent/Vents in Place Rough Plumbin Heating Rough-in Insulation Foundation Walls interior R- Foundation Watts Exterior R- Floors R- Walls R- C`.eiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framin Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air infiltration Barrier Fire separation 1, 2, 3, hour Penetration Sealed — Fire Wall 2. 3, 4 hour Firestoppm 4CL `I OWN OF QJEEN'SBUR,Y 742 Bay Road, Queensbury, NY 12804-5902 518-761 -8201 September 24, 1998 Jim Miller Northfield Designs la Old Coach Road Diamond Point, NY 12824 Dear Jim, This letter will confirm our conversation regarding the expansion of Skateland and projects included in that expansion. The items specifically we are dealing with is exterior fire separations between buildings. As we discussed, the go kart repair building will need to provide a minimum Two Hour masonry wall abutting the existing masonry wall from the footings to the roof deck where the two buildings adjoin each other. The wall that is opposite the expansion for the cafeteria will need to be at least a Three Quarter Hour rating with a noncombustible exterior finish_ The go kart storage building will need to provide a Three Quarter Hour exterior wall with noncombustible facing on any side that faces the existing Skateland building. We also talked about perhaps moving the building so that only one side of the go-kart storage building would need to be rated. It was also confirmed that the expansions to the building will not exceed the allowed fire area for this building, and that the seating capacity for the cafeteria will not be expanded, and will be maintained less than lop persons occupancy- If any of the above information is incorrect per our discussion, please contact me immediately, otherwise the above information is relative to the proposed project_ Thank you for your time. Sincerely-, David Hatin, Director Building and Code Enforcement DH/mg "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO LIVE" SETTLED 1763