Loading...
SEP-0420-2022 SEPTIC DISPOSAL PERMIT office•useOnllyy��p. _ APPLICATION Permit#: Town of ouc s ry Q Permit Fee:$ g5 Invoice#: I y 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Septic Variance? Y G �Flood Zone? Y Wetlands? Y Reviewed By: Project Location: 51 Mason Road IF Tax Map #: 226.16-1-19 9 JUL 0 5 2022 RESIDENCE INFORMATION: . I ` N Year Built Gallons #of bedrooms: X gallons per =total dailyl'floWd A'i, s Cai 11__F=n.PPi ll V i per day bedroom s �i�l 66i?6age*Uff,d'er Yes No- 1980 or older 150 Installed? (choose one) ❑ [� 1981-1991 130 - Spa or Hot Tub Yes No 1992-Present 110 3 110 330 Installed? (choose one) ❑ [� PARCEL INFORMATION: Topography Flat Rolling ❑ Steep Slope % Slope Soil Nature ❑ Sand [0 Loam ❑ Clay ❑ Other, explain: Groundwater At what depth? . Bedrock/Impervious material At what depth? Domestic Water Supply ❑.Municipal V Well ❑Lake (if well or lake, water supply from any septic system absorption is ft.) Percolation Test Rate: per minute per inch (test to be completed by a licensed engineer/architect) 'PROPOSED SYSTEM INFORMATION: - Existing septic tank & field to remain Tank size gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage.Pit w/#3 stone How many: :; Size: 'Alternative System Bed or,other type: Holding Tank System Total required capacity? ; tank size ; # of tanks Existing Septic Tank and Field to remain - Pump Station replacement ONLY Septic Application Revised April 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): William Wetherbee Mailing Address, C/S/Z: P.O. Qdy253 Cleverdale. NY 12820 Cell Phone: = Land Line: Email: • Primary Owner(s): Name(s): William B. Wetherbee Trust Mailing Address, C/S/Z: P.O. Box 253 Cleverdale, NY 12820 Cell Phone: Land Line: Email: 0 Check if all work will be performed by property owner only • Contractor: Contact Name(s): Crandall Excavating Contractor Trade: Installation Mailing Address, C/S/Z: 63 Woodchuck Hill.Road Lake George, NY 12845 Cell Phone: 518-470-4694 Land Line: Email: "Workers' Comp documentation must be submitted with this application" • Engineer(s): Name(s): Hutchins Engineering PLLC Mailing Address, C/S/Z: 169 Haviland Road QueensbUW, NY 12804 Cell Phone: Land Line: 518-745-0307 Email: tutchins@hutchinsengineerinq.corn Contact Person for Compliance in regards to this project: Cell Phone: Land Line: Email: NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no'.ekceptiom. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. 4. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is-retained. Declaration: Any permit or approval granted which"is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of.Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: G. Thomas Hutchins, .E. AGENT) SIGNATURE: ( b DATE: 7/5/22 Septic Application Revised April 2021 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist Plan to scale Received Deep hole pert test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) All wells on property and adjacent properties shown 4�:' Water line shown Municipal or well 10'separation to any part of system CW`Aetback to property lines show 10'or more for any part of system e"ptic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline f✓. Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) 44 Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each i✓ Leech Field 20'from foundation 100'from any well 10'from water line /I -h4eepage pit 150'from well 50'from septic tank Oseepage Pits 3-times diameter apart Septic tank and pump stations over 30 gallons 50'from watercourse or wetland distance from bottom of trench or system 24" to bedrock or mottling 36"within 1000' of Lake George r/�ALeech field 100' from watercourse or wetland N Toe of mound or bottom of retaining wall 10'from property line 100'from well 20'from Foundation Provide Engineer/Architect stamp f ems 1- '' Department of Health Approval for all mobile home park new systems Flood Plain requirements d4b 2' above established flood elevation to bottom of system 1-J6 All tanks anchored or 2' above flood elevation 12—A—A A/1 ;/7n71 LAKE ! i GEORGE ///� — — �•.� — — `_ LANDS N/F OF —1_ — — M DREAM, LLC 183 7.0' '�- :. 1V81 LANDS NIP OF WMIAM B WE'TEERBEE TRUST LAKE WATER SUPPLY LANDS N/F OF ROBERT EVANS LAKE HATER SUPPLY �P sE�ACK PUMP STATION REPLACEMENT PLAN SCALE. 1"--10' GRAPHIC SCALE 5 0 2.5 5 10 20 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES THIS IS NOT A FIELD SURVEY. SETBACK7 UAW ATI EXIS71 G WASTEWATER l / ABSORPTION FIELD / a / 0 10' P.L- SET, 9ACK '•/ -- — EXTENSION TO WPER RESISTANT (NON —TRAFFIC -.AS) LIFTING CABLE OR CHAIN 118" PER FOOT MIN. SLOPE " EFFLUENT SEWER ALARM 3" ABOVE 'PUMP ON' PUMP ON PUMP OFF VOLUME OF DOSE TO BE 40-50f GALLONS FLOAT SWITCHES — INSTALL INSIDE PUMP PIT IN LOCATION ACCESSIBLE WITHOUT PIT ENTRY MAP REFERENCE: 1. BASE MAP INFORMATION FROM WARREN COUNTY CIS, AERIAL PHOTOGRAPHY, AND FIELD MEASUREMENTS. THIS IS NOT A FIELD SURVEY. ALL LOCATIONS ARE APPROXIMATE CONTRACTOR TO FIELD VERIFY ALL SETBACKS PRIOR TO BEGINNING INSTALLATION. 2. NORTHERN NEIGHBORING PROPERTY INFORMATION FROM "MAP OF LANDS OF ANGELA M. AND ROBERT P. KLADIS, SHOWING THE LOCATION OF THE RESIDENCE, LOCATED ON AUGUST 7, 1997," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED AUGUST 7, 1997. PREPARED BY COULTER & MCCORMACK LICENSED LAND SURVEYORS. 3. SOUTHERN NEIGHBORING PROPERTY INFORMATION FROM "MAP OF LANDS BELONGING TO ROBERT L. EVANS, IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED JUNE 19, 1989. LAST REVISED AUGUST 11, 1993. PREPARED BY COULTER & MCCORMACK LICENSED LAND SURVEYORS. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' 100' 16" MIN. 4'0 PRECAST CONCRETE MANHOLE USED AS PUMP STATION INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED PUMP STATION DETAIL SCALE. NTS SITE LOCATION -' LOCATION MAP 1-1/2" FORCEMAIN BALL VALVE EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START—UP OF PUMP STATION. TRANSITION TO 4" OUTSIDE OF D—BOX 12" MIN. COVER DISTRIBUTION BOX ,' CONCRETE BAFFLE USE SPEED LEVELERS TO ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION 2" MIN. DROP 4" PVC SOR-35 SOLID HEADER TO BETWEEN INVERTS ABSORPTION LATERALS, 1/8" PER FOOT MIN SLOPE 1-112" SCH-40 PVC PIPING INSIDE WET PUMP STATION NOTES WELL THROUGH WALL SEAL ALL TANK OPENINGS WATERTIGHT. UNION — LOCATE SUCH THAT UNION CAN BE DISCONNECTED AND PUMP PROVIDE AND INSTALL UL LISTED PACKAGED PUMP REMOVED WITHOUT TANK ENTRY CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. REDUCING TEE POINTED DOWNWARD WITH 1" INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL BALL VALVE THROTTLED TO ALLOW TRICKLE INSIDE HOUSE IN ACCESSIBLE LOCATION. DRAIN BACK INTO WET WELL INSTALL POWER & CONTROL WIRING TO CONTROLLER BALL CHECK VA*MIN OF QUEENSBURY DEPARTMENT WIN ALARM IN HOUSE IN ACCORDANCE WITH GOULDS WE03L INS comp fiance MANUFACTURER'S INSTRUCTIONS AND NA1i0NAL Based on our limited examination, trued an not bfica# ELECTRIC CODE (N.E.C.) REQUIREMENTS. with our Comments plans and ors are indicating P Codes 0f the uilding PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED full compliance with TO PROVIDE A 40-50 GALLON DOSE. EFFLUENT PUMP TO BE GOULDS PUMPS WE SERIES, R TO FIELD r%WERIFFY MODEL WE03L SUBMERSIBLE EFFLUENT PUMP 113 HP, MP STATION 230 VOLT, 1PH REQUIRED VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO �� COPY � P 3 START—UP OF PUMP STATION. Ll 1' � 4 BURY• �Lj 226.16-1-19 � 6 Wetherbee, Willia IL 9 CODES DEFT` JUL 0 5 2022 x 51 Mason Rd B. TOip�i r. EUER r Y Residential Septic AI n `l ��'� rl `' �. .. TAX MAP # 226.16-1-19 Dig (Safely. New/.York ■ Call Before You Dig ■ Wait The Required Time ■ Confirm Utility Response ■ Respect The Marks ■ Dig With Care 800.962-7962 www.dirmfeiynewyork.com 2' MIN. LANDS N/F OF — M DREAM, LLC ,gip L'�JBACK \ SHED PUMP STATION REPLACEMENT PLAN SCALE. I"--10' GRAPHIC SCALE 5 0 2.5 5 10 20 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES THIS IS NOT A FIELD SURVEY. RECORD DRAWING DIMENSIONS TABLE CORNER "A" CORNER "B" PUMP STATION PORT 26' 13.5' MAP REFERENCE: 1. BASE MAP INFORMATION FROM WARREN COUNTY GIS, AERIAL PHOTOGRAPHY, AND FIELD MEASUREMENTS. THIS IS NOT A FIELD SURVEY. ALL LOCATIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ALL SETBACKS PRIOR TO BEGINNING INSTAH AWON. 2. NORTHERN NEIGHBORING PROPERTY INFORMATION FROM "MAP OF LANDS OF ANGELA M. AND ROBERT P. KLADIS, SHOWING THE LOCATION OF THE RESIDENCE, LOCATED ON AUGUST 7, 1997," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED AUGUST 7, 1997 PREPARED BY COULTER & MCCORMACK LICENSED LAND SURVEYORS. J. SOUTHERN NEIGHBORING PROPERTY INFORMATION FROM "MAP OF LANDS BELONGING TO ROBERT L. EVANS, IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED JUNE 19, 1989. LAST REVISED AUGUST 11, 1993. PREPARED BY COULTER & MCCORMACK LICENSED LAND SURVEYORS. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' 100' SITE LOCATION --I LOCATION MAP EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION. TRANSITION TO 4" 12" MIN. COVER OUTSIDE OF D-BOX DISTRIBUTION BOX CONCRETE BAFFLE 1-112" USE SPEED LEVELERS TO L�FORCEMAIN ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVATION BALL VALVE 4" PVC SDR-35 SOLID HEADER TO ABSORPTION LATERALS, 118" PER FOOT MIN SLOPE F 16" MIN. 1. d 4'0 PRECAST CONCRETE MANHOLE USED AS PUMP STA71ON INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED PUMP STATION DETAIL SCALE. NTS 1-1/2" SCH-40 PVC PIPING INSIDE WET WELL THROUGH WALL UNION - LOCATE SUCH THAT UNION CAN BE DISCONNECTED AND PUMP REMOVED WITHOUT TANK ENTRY REDUCING TEE POINTED DOWNWARD WITH 1" BALL VALVE THROTTLED TO ALLOW TRICKLE DRAIN BACK INTO WETWELL BALL CHECK VALVE GOULDS WE03L PUMP W TO FIELDSTATIONUIRED A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE DURING CONSTRUCTION AND IT IS MY OPINION THAT THE SYSTEM IS INSTALLED IN GENERAL CONFORMANCE WITH THE APPROVED PLAN AND THIS RECORD DRAWING. FINAL SURFACE FINISHING AND TURF ESTABLISHMENT IS ONGOING G. THOMAS HUTCHINS, P.E. 71512023 EM Call Before You Dig Wait The Required Time IM Confirm Utility Response EM Respect The Marks IM Dig With Care 800-962-7962 www.digsafelynewyork.com 2" MIN. 2" MIN. DROP BETWEEN INVERTS PUMP STATION NOTES SEAL ALL TANK OPENINGS WATERTIGHT. PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE LOCATION. INSTALL POWER & CONTROL WIRING TO CONTROLLER IMTH ALARM IN HOUSE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NA71ONAL ELECTRIC CODE (N.E.C.) REQUIREMENTS. PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED TO PROVIDE A 40-50 GALLON DOSE. EFFLUENT PUMP TO BE GOULDS PUMPS WE SERIES, MODEL WE03L SUBMERSIBLE EFFLUENT PUMP 113 HP, 230 VOLT, 1PH VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION. INSTALLATION DATE: 612912023 INSTALLED BY - CRANDALL EXCAVATING, INC TAX MAP # 226.16-1-19