IM Inspection Worksheet_14-07-2023_14-46-46INSPECTION WORKSHEET (COMFIN-026570-2023) CC-0109-2023Case Number:Case Module:Permit Management 07/14/2023 PassedInspection Status:Inspection Date: Commercial Final InspectionInspection Type:Inspector:Mark Smith Job Address:Parcel Number:75 Carey Rd Queensbury, NY 12804 308.20-1-3.3 Company Name NameContact Type Applicant Okie Properties, LLC Engineer Mark Bergeron Granted Permission Okie Properties, LLC Primary Owner Okie Properties, LLC Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle True Building Inspector Notes True 6/9/23 partial approval for for final inspection of tenant fit up please address the items listed below - provide letter of substantial completion from design architect. - provide air balancing report. - remove the non fire rated plywood from loft area. - submit electronic as built drawings. - install unit number at front of building. 6/14/23 final commercial inspection not approved - non fire rated plywood must be removed from loft as dissolved on site - provide electronic as built drawings 6/16/23 partial approval for final commercial inspection - provide letter of substantial completion from architect - complete Fire Marshals items * if you are unable to provide this requested information by Monday 6/19 you will need to get a temporary Certificate of Occupancy. 7/13/23 final commercial inspection approved - letter of substantial completion received Bldg Access All Sides 20ft Drivable Surface True H/C rear grab bar 36" with 24" to open side True Public Toilet Room Handicapped Accessible True Handicap parking striping True Bldg Num or Tenant Address on Bld or Drive True Gas Shut-off Exposed & Regulator 12" min abv grd True Gas Furnace Shut Off True H/C side & rear grab bars 36" above floor True HVAC air balancing report True H/C sinks 34" above floor True H/C 18" minimum vertical grab bar True Engineer or Architect Approval True Hot water drain pan to indirect waste True H/C grab bar: 42" side, 12" from center True July 14, 2023 Page 1 of 2 INSPECTION WORKSHEET (COMFIN-026570-2023) Checklist Item CommentsPassed OK to Issue C/O True HVAC Vent Terminal 10' from Lot Line & Openings True Universal Symbol of Access displayed True Final Electrical / Flex Gas Piping Bonded True Plumbing Vent Through Roof/Roof complete True Relief Valve ,Heat Trap/Water Temp 110 deg or less True Electronic as-builts True Handicapped Bath/Parking Lot Signage True Exits At Grade Or Platform 36 (w) x 44 (l)True H/C mirrors 40" above floor True H/C toilet flush handle on open side True Outside Spigots have Air Gap True H/C vertical grab bar 39" from floor and corner True Ext Finish /Grade Complete/6 in 10ft or Equivalent True Floor Bathroom Watertight Other Floors Okay True July 14, 2023 Page 2 of 2