SEP-0425-2023 APPLICATION Permit#: �—0�2
QG
Town ofQmensbun- ��7 Permit Fee:$ i�✓ 1
lE C �'' u V E Invoice#: (a�`�
742 Bay Road,Queensbury,NY 12804
P:s18-761-8256 www. ueensbu .ne Flood Zone? Y '6 Reviewed By
JUL 13 2023
TOWN OF QUEENSBURY
UiLDING & CODES
Project Location: 5 e R��€ ��
Tax Map #: 308.8-1-22
RESIDENCE INFORMATION:
Year Built Gallons #of bedrooms: X gallons per =total daily flow
per day bedroom Garbage Grinder Yes No
1980 or older 150 Installed? (choose one) X
1981-1991 130 Spa or Hot Tub Yes No
1992-Present 110 5 t110 550
Installed? (choose one) X
PARCEL INFORMATION:
Topography f Flat Rolling Steep Slope % Slope
Soil Nature Sand Loam Clay Other, explain:
Groundwater At what depth? GREATER THAN 6 FT
Bedrock/Impervious material At what depth? GREATER THAN 6 FT
Domestic Water Supply Municipal Well Lake
(if well or lake,,water supply from any septic system absorption is
ft.)
Percolation Test Rate: 1-5MIN per minute per inch (test to be completed by a
licensed engineer/architect)
PROPOSED SYSTEM INFORMATION:
Tank size EX1500 gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or
spa/hot tub EXISTING 1000 GAL CONCRETE
System Absorption field w/42 stone Total length ft.; Each Trench ft.
Seepage Pit w/#3 stone How many: ; Size:
Alternative System Bed or other type:20 FT X 40 FT
Holding Tank System Total required capacity? ; tank size ;
# of tanks
• Applicant:
Name(s):JAMES LANDERS
Mailing Address, C/S/Z: 51 SMOKE RIDGE ROAD, QUEENSBURY,NY 12804
Cell Phone: Land Liner
Email:
• Primary Owner(s):
Name(s): SAME AS APPLICANT
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
Check if all work will be performed by property owner only
• Contractor:
Contact Name(s):SMITHS EXCAVATING
Contractor Trade:
Mailing Address, C/S/Z:354 LUZERNE RD, QUEENSBURY
Cell Phone: Land Line:518-361-0956
Email:
"Workers' Comp documentation must be submitted with this application**
• Engineer(0:
Name(s): CENTER PROJECT SERVICES
Mailing Address, C/S/Z:73 SHERIDAN STREET, GLENS FALLS NY 12801
Cell Phone: Land Line:
Email:
Contact Person for Compliance in regards to this project: Rip
Cell Phone: Land Line: �4Z
Email:
NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical
inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is
received and approved.The installed system must match the septic layout on file—no exceptions. 3. As-
built drawings must be submitted prior to the inspection, if there has been a change to the submitted
plans. 4. If,for any reason,the building permit application is withdrawn, 30% of the fee-is retained by the
Town of Queensbury. After 1 year from the initial application date, 10.0 of the fee is retained.
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material
representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be
void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury
Sanitary Sewage Disposal Ordinance.
PRINT NAME:FIR
SIGNATURE: DATE: 7 /1/)01 :2,3
TOWN OF QUEENSBURX "c`
742 Bay Road, Queensbury,NY. 12804-5902
Septic System Checklist.
Plan to scale
Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and
Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) U`g4 V
All wells on property and adjacent properties shown
Water line shown Municipal or well 10'separation to any part of system
Setback to property lines show 10'or more for any part of system
Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline
peptic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank
for 0,Separation required(field verification required)
-aseptic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each
Leech Field 20'from foundation 100'from any well 10:from water line
PbSeepage pit 150'from well 50'from septic tank
PLkeepage Pits 3-times diameter.apart
"Septic tank and pump stations over 30 gallons 50'from watercourse or wetland
distance from bottom of trench or system 24"to bedrock or mottling 36"within 1000'of Lake George
Aeech'field 100'from watercourse or wetland
)LfWToe of mound or bottom of retaining wall 10'from.property line 100'from well 20'from
Foundation
�r1
(PZ Provide Engineer/Architect stamp for bed or design systems'
8" bepartment of Health Approval for all mobile home park new systems Flood Plain requirements
k2'above established flood elevation to bottom of system
�±- All tanks anchored or 2'above flood elevation
3lR3moAdsS'�{/?A?1
C-C FI�-e TOWN OF QUEENSBURY
BUILDING & CO ES EPT.
�r Rat °
q t1to 1�-� te:
Q
TOWN OF QUEENSBURY
-J BUILDING DEPARTMENT
Co a ed on our limited examination,compliance
q it our comments shall not be construed as Aj
i di ating the plans and sppecifications are in
f 11 ompliance with the Building Codes of
e York State.
.o
�, FILE ropy
0
zo
Ww
w U�I -2023
C M SEP-0425
J o 0 308.$CS Tammie
Land
m 51 Smoke Ridge Rd
Residential Septic Alteration
cc.7D
CENTER PROJECT
SERVICES
73 Sheridan Street, Glens Falls,NY 12801
Phone-518-796-2515
June 2,2022 .
Project.# 373
Fred Smith
Smiths Excavating
354 Luzerne Road
Queensbury,NY 12804
Re: Proposed Replacement Septic .
51 Smoke Ridge Road, Queensbury,NY
Dear Fred:
At your request, we have reviewed your proposed replacement septic system design of the
existing 5-bedroom house at 51 Smoke Ridge Road in Queensbury. As per our conversation the
residence has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable.Based upon a design flow rate of 550 GPD and a percolation rate of
1 to 5 minutes, you will need a minimum of 612 sf of absorption area. We recommend using 20
ft wide by 40 ft long absorption bed with 4 — 35 ft long laterals. The absorption system can be
constructed with the existing 1,500-gallon septic tank, new distribution box, and 4-inch diameter
perforated pipe and stone.
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely,
Thomas R. Center Jr,P.E.
r
1.v •
TOWN OF QUEENSBURY
�— ' BUILDING & C DES DEPTo
" Reviewe B
Date
UM PRIMtTYl
Cc> _
r ,
_. '
-- - --_
I TOWN, F QUEENSBURY ,
BUILDING DEPARTMENT
Based on our lima ed.examination,compliance �L
with our commen s shall not be construed as Zi
indicating the plE is and specifications are in
full compliance 4th the Building Codes of
New York State.
�I
�e7
11
> AS BUILT
'r :a
^,
00
om
~ 308.8-1-22 SEP-0425-2023
Landers, Tammie
51 Smoke Ridge Rd
Residential Septic Alteration
CENTER PROJECT
SERVICES
73 Sheridan Street, Glens Falls,NY 12801
Phone-518-796-2515
June 2,2022
Project#373
Fred Smith
Smiths Excavating
354 Luzerne Road
Queensbury,NY 12804
Re: Proposed Replacement Septic
51 Smoke Ridge Road,Queensbury,NY
Dear Fred:
At your request, we have reviewed your proposed replacement septic system design of the
existing 5-bedroom house at 51 Smoke Ridge Road in Queensbury. As per our conversation the
residence has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable. Based upon a design flow rate of 550 GPD and a percolation rate of
1 to 5 minutes, you will need a minimum of 612 sf of absorption area. We recommend using 20
ft wide by 40 ft long absorption bed with 4 — 35 ft long laterals. The absorption system can be
constructed with the existing 1,500-gallon septic tank, new distribution box, and 4-inch diameter
perforated pipe and stone.
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely,
Thomas R. Center Jr,P.E.