IM Inspection Worksheet_24-07-2023_15-50-10INSPECTION WORKSHEET (RESFINAL-026777-2023) RC-0303-2022Case Number:Case Module:Permit Management 07/24/2023 Partial PassInspection Status:Inspection Date: Residential Final InspectionInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:6 Cobblestone Dr Queensbury, NY 12804 290.18-1-6 Company Name NameContact Type Applicant Monty Liu Architect Rucinski-Hall Architecture Contractor LJB Concrete LLC Granted Permission Monty Liu Primary Owner Monty Liu Checklist Item CommentsPassed bedroom(s) with gas appliances False Low flow toilet 1.3 gal/flushing cycle False Bathroom Fans, if no window False 3" Plumbing Vent through roof minimum 18 inch False Grade away from foundation: 6" down, 10' out False Final Survey Plot Plan False Sewer Dept. Inspection Sticker False Window guards req:<2' above floor/6' above grade False Interior privacy/trim/doors/main entrance 36 False Backflow Preventors where required False Basement wall insulation R- value verified False Emergency egress below grade False Fuel Tanks above flood plain elevation False Intake Openings False Safety glazing: w/in 5' of tub/shower False Site Plan / Variance required False Seals on Garage Doors, esp. Wood False Not less than 3' horiz from opening of bthrn False Basement ceiling covered 2x8 fl joist or less False Attic Access Insulation = Attic R- Value False Gas Shut-off Exposed & Regulator 12" min abv grd False Platform at all exterior doors False Fireblocking at fl joist 80 s.f. or less False Garage Floor Pitched False Buried Fuel Tanks anchored in flood zone False Wood deck: 2'+ from grade dia bracing required False Inter Connected False Arc Fault Breaker Habitable Spaces False Dryer Duct Max Length 35', Labeled Over 35'False July 24, 2023 Page 1 of 3 INSPECTION WORKSHEET (RESFINAL-026777-2023) Checklist Item CommentsPassed Energy Sticker on Elec. Panel:R-Val. & Heating Sys False Furnace/Hot Water Heater operating False Hot water drain pan to indirect waste False Fresh Air Intake False Chimney Rain Cap Installed False Basement stairs closed rise greater than 4 inches False Foam in basement/attics covered w/thermal barrier False Outside every bedroom area False Oil Furnace Shut-Off at Entrance to Furnace Area False Blower Door Test Certification False Fin Elect; Energy Saving Light Bulbs 90 Percent False Heat detector in garage False Gas Log In Sealed or Glass Enclosure False OK to Issue C/O False Truss ID Signage Installed at Electrical Meter False Range Hood 400+ cfm-Fresh Air REQUIRED False 4 inch Building Number Address visible from road False CO in bedrooms w/gas appliances False HVAC Vent Terminal 10' from Lot Line & Openings False Attic Access Gasketed False Jack posts in basement lagged at top and bottom False Flood Plain Certification, if required False Furnace shut-off w/in 30 ft. or w/in line of site False Bathroom / Kitchen Watertight False As Built Septic System False Flex Gas Pipe Bonding False Guard at stairwell at 34" or more False Outside Spigots have Air Gap False Battery backup False OK to Issue Temporary C/O False Roof Complete / Exterior Finish Complete False 1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss False Interior/Exterior Railings 34 to 38 False 6" clearance to sill plate False 20 Minute Fire Door/Self-Closing Hardware False 1/2" Gypsum or House Wall and Gable False Plumbing fixtures False Knee wall/Crawl space 18" x 24"False 4+ Deck Joist Ledger Connections-24" From Ends False Guards at stairs,decks,patios 30" + above grade False Duct work sealed properly False Propane Tank: Proper Setback from Prop Line/Struct False July 24, 2023 Page 2 of 3 INSPECTION WORKSHEET (RESFINAL-026777-2023) Checklist Item CommentsPassed Smoke Detectors:False Pull down stairs boxed out and insulated False Attic Access 22 x 30 minimum False Chimney Height / B Vent / Direct Vent Location False Relief Valve ,Heat Trap/Water Temp 110 deg or less False on all levels w/gas appliances (i.e. furnace)False Crawl space/knee wall access insulated & gasketed False Every level, Every bedroom False Fresh air supply 3' from grade False Guard at deck, porches 36" or more False Encl. Stairs Sheetrock Underside minimum ½ Gypsum False HRV or ERV Installed per Bedroom Requirements False Handrail 4 or more risers False Floor truss, draft stop- fin base 1,000 sq. ft.False Handrail Termination at Newell Post or Wall False Foundation insulation to floor False Carbon Monoxide Detectors:False All Hot Water Systems: 3/4" or larger piping R-3 False General Comments True arrived roughly 0915, knocked on garage door couple of times, waited, no answer. Please call to reschedule. 518-761-8207. Thank you Inspection was not for a residential final hard pan dryer vent / fire caulk penetrations at garage / remove wooden door / replace with 20 minute rated door / ok to insulate garage ceiling R-38 within 10' of all sleeping areas False 5/8" Type X with Living Space Above False Electronic as-builts False Low water shut-off boiler False CSST/other piping in conduit if buried,if required False Deck Ledger-Bolted per Code False Basement Egress: 5s.f. window w/sill or Bilco door False July 24, 2023 Page 3 of 3