AST-0392-2023(2)HAANEN ENGINEERING
254 BAY ROAD
PH. (518) 793-7444
FAX (518) 793-7061
To: Duncan Mularz, Dean Hyv-
From: Daniel A. De Nero Y
Date: 07/25/23
Re. Ticket Booth Rear Pergola & Window Opening framing Inspection (HE#84017)
Duncan,
Hernal Golwala, a representative of Haanen Engineering visited the site on July 20, 2023 to inspect the framing of ticket
booth rear pergola and window opening framing. Based on visual inspection, the rear shed pergola framing is in
conformance with the permit set drawings.
The window opening size has been modified from (2) 2'-9" opening to (1) 7'-0" opening. The lintel size has been
changed from L5"x3 1/2"x5/16" to L6"x4"x3/8". The header size has been changed from (2) M members to (2) 2xl 0
members. Based on analysis, the L6"x4"x3/8" lintel and (2) 2xl 0 header is adequate for anticipated loading as per New
York State Building Code 2020.
Should you have any questions, feel free to contact me.
U of NEW
A.
Daniel A. De Nero, P.E.