IM Inspection Worksheet_31-07-2023_15-33-09INSPECTION WORKSHEET (POOL-026889-2023)
POOL-0250-2023Case Number:Case Module:Permit Management
07/31/2023 PassedInspection Status:Inspection Date:
PoolInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:516 Luzerne Rd
Queensbury, NY 12804
308.6-2-1
Company Name NameContact Type
Applicant Holly Irion
Contractor Pools Plus
Granted Permission Shane Donaldson
Primary Owner Holly Irion
Checklist Item CommentsPassed
Self closing device or alarms (30 sec Alarm time)True
Gate less than 56" to latch ½ max space in open True
Suction outlt must be protected agst user entrpmnt True
Final Electrical True
Pool enclosure around pool or yard True
2 inch max to grade from underside of fence True
Pool Surface Motion Alarm True
Wndws <48” abv flr reqd to latch w/o 4” orb True
Padlock provided on gates or ladder True
Ladder secured in place and latched True
4 feet above grade True
Timer on pool pump (no plug in timer allowed)True
Vehicle access gate closed & locked True
Ok to issue CC True
Gate opens outward, self closing True
Permit Card Visible From Road True
July 31, 2023 Page 1 of 1