IM Inspection Worksheet_31-07-2023_15-45-29INSPECTION WORKSHEET (RESFINAL-026794-2023)
RC-0261-2020Case Number:Case Module:Permit Management
07/31/2023 Partial PassInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Mark Smith
Job Address:Parcel Number:12 Shore Acres Rd
Queensbury, NY 12804
227.17-1-11
Company Name NameContact Type
Applicant Daniel Frazier
Meghan Frazier
Architect Phinney Design Group
Contractor J. Clarke Construction
Granted Permission J. Clarke Construction
Primary Owner Daniel Frazier
Meghan Frazier
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle True
Bathroom Fans, if no window True
3" Plumbing Vent through roof minimum 18 inch True
Grade away from foundation: 6" down, 10' out False Complete site work.
Final Survey Plot Plan False
Window guards req:<2' above floor/6' above grade True
Interior privacy/trim/doors/main entrance 36 True
Emergency egress below grade True
Safety glazing: w/in 5' of tub/shower True
Seals on Garage Doors, esp. Wood True
Gas Shut-off Exposed & Regulator 12" min abv grd True
Platform at all exterior doors False
Garage Floor Pitched True
Inter Connected True
Arc Fault Breaker Habitable Spaces True
Dryer Duct Max Length 35', Labeled Over 35'True
Furnace/Hot Water Heater operating True
Fresh Air Intake True
Basement stairs closed rise greater than 4 inches True
Foam in basement/attics covered w/thermal barrier False Provide thermal barrier at laundry room attic
Outside every bedroom area True
Oil Furnace Shut-Off at Entrance to Furnace Area False
Blower Door Test Certification False
Fin Elect; Energy Saving Light Bulbs 90 Percent True Middle inspection service
Gas Log In Sealed or Glass Enclosure False
OK to Issue C/O False
Truss ID Signage Installed at Electrical Meter True Check with Fire Marshal for placement of truss ID
July 31, 2023 Page 1 of 3
INSPECTION WORKSHEET (RESFINAL-026794-2023)
Checklist Item CommentsPassed
Range Hood 400+ cfm-Fresh Air REQUIRED False
3/16/23 make up air for oven hood verified as operational,
contractor to provide as build drawing of system.
4 inch Building Number Address visible from road False
HVAC Vent Terminal 10' from Lot Line & Openings True
Guard at deck, porches 36" or more True
6" clearance to sill plate True
5/8" Type X with Living Space Above True
20 Minute Fire Door/Self-Closing Hardware False
Every level, Every bedroom True
Furnace shut-off w/in 30 ft. or w/in line of site True
Floor truss, draft stop- fin base 1,000 sq. ft.True
within 10' of all sleeping areas True
on all levels w/gas appliances (i.e. furnace)True
Relief Valve ,Heat Trap/Water Temp 110 deg or less True
Electronic as-builts False
1/2" Gypsum or House Wall and Gable True
Basement Egress: 5s.f. window w/sill or Bilco door True Walk out basement
Bathroom / Kitchen Watertight True
HRV or ERV Installed per Bedroom Requirements True
Duct work sealed properly True
As Built Septic System True
Outside Spigots have Air Gap True
OK to Issue Temporary C/O False
All Hot Water Systems: 3/4" or larger piping R-3 True
Battery backup True
Guard at stairwell at 34" or more True
Fresh air supply 3' from grade True
Interior/Exterior Railings 34 to 38 True
Smoke Detectors:True
Roof Complete / Exterior Finish Complete True
Carbon Monoxide Detectors:True
Handrail 4 or more risers True
Guards at stairs,decks,patios 30" + above grade True
July 31, 2023 Page 2 of 3
INSPECTION WORKSHEET (RESFINAL-026794-2023)
Checklist Item CommentsPassed
General Comments False 2/22/23 partial approval for for final inspection of single family
dwelling. Please address the following items
- provide letter of substantial completion from architect stating that
the project was completed in accordance with the approved plans
and specifications.
-provide a maintenance agreement for the septic system
-a 20 minute thermal barrier is required at the laundry room attic at
the spray foam insulation.
-20 minute fire door at garage is required to be self closing and
latching.
-complete work in theater room
- complete exterior stone work and siding
- any exterior door that with out a platform will need to be secured.
-submit blower door test results
- submit final stamped survey
-- complete exterior site work.
- a final inspection by Code Compliance officer Bruce Frank is
required.
-provide electronic as built drawings.
2/24/23 final inspection of single family dwelling approved for
temporary Certificate of Occupancy only, the items listed above
must be addressed before a C.O can be issued.
3/16/23 make up air for oven hood verified as operational,
contractor to provide as build drawing of system.
7/31/23 partial approval for final inspection of single family
dwelling.
-temporary C.O. has been renewed.
3' from Baths True
Plumbing fixtures True
Attic Access 22 x 30 minimum True
Handrail Termination at Newell Post or Wall True