PM Permit Inspection History Report_01-08-2023_11-25-32PERMIT INSPECTION HISTORY REPORT (SEP-0700-2022)
Septic Alteration
Septic Disposal-Residential
Issued
11/21/2022
01/23/2024
01/23/2023
15 Brayton Ln
Lake George, NY 12845
Address:
Expiration Date:
Issue Date:
Application Date:
Status:
Work Class:
Permit Type:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
01/25/2023 Septic SEP-023348-2023 Partial Pass Mark Smith Reinspection Incomplete
COMMENTS PassedChecklist Item
Building Inspector Notes 1/25/23 partial approval for replacement
septic system.
A new 1000 gallon septic tank is gravity
fed to a new precast D box and an
absorption field of eljen mats. Two laterals
at 32' feet each.
- access riser at inlet side of septic tank is
required.
- provide as built drawing from design
engineer.
No
Roof gutters don't discharge
over leach field
Yes
Soil Type: Sand Yes
Type of Water: Municipal / Well
Water
Well water Yes
Waterline separation distance Yes
Well separation distance Yes
Absorbtion Fields: Total Length 2 laterals at 32' each, 64' total Yes
Septic system field above
flood plain
Yes
Sump pump not connected to
septic system
Yes
Length of Each Trench 2 laterals at 32' each, 64' total Yes
Depth of Trenches 14/16"Yes
System Use Status System approved for use Yes
Building to Tank 4" schedule 40 connected to existing cast
iron pipe
Yes
Tank to Distribution Box 4" schedule 40 Yes
Distribution box to Field / Pit 4" SDR 35 to eljen mats Yes
Opening Sealed:Yes
End Cap Yes
InletOutlet Pipes & Baffles Filter at outlet side of septic tank Yes
Inlet & Outlet manholes 12"+
below grade
Provide access riser at inlet side of septic
tank
No
[Provide extension collar if
Yes]
Provide access riser at inlet side of septic
tank
No
Locations / Separations Yes
Foundation to Tank No
Foundation to Absorption No
Size of tank 1000 gallon septic tank Yes
Conforms as per Plot Plan Yes
Engineer Report and As-Built Provide as built drawing from design
engineer
No
Location of system on
property
Septic tank is in back yard, absorption field
is in side yard near holly lane
Yes
NOTES Created By TEXT Created Date
Kate Deck scheduled with Andy at the B&C window 01/24/2023
August 01, 2023 Page 1 of 6
Septic Alteration
Septic Disposal-Residential
Issued
11/21/2022
01/23/2024
01/23/2023
15 Brayton Ln
Lake George, NY 12845
Address:
Expiration Date:
Issue Date:
Application Date:
Status:
Work Class:
Permit Type:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
08/01/2023 Septic SEP-026951-2023 Partial Pass Mark Smith Reinspection Incomplete
August 01, 2023 Page 2 of 6
Septic Alteration
Septic Disposal-Residential
Issued
11/21/2022
01/23/2024
01/23/2023
15 Brayton Ln
Lake George, NY 12845
Address:
Expiration Date:
Issue Date:
Application Date:
Status:
Work Class:
Permit Type:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
COMMENTS PassedChecklist Item
Building Inspector Notes 1/25/23 partial approval for replacement
septic system.
A new 1000 gallon septic tank is gravity
fed to a new precast D box and an
absorption field of eljen mats. Two laterals
at 32' feet each.
- access riser at inlet side of septic tank is
required.
- provide as built drawing from design
engineer.
8/1/23
Bob,
I left messages on your phone but you
have yet to reply. Please forward to my
attention the certified septic system as-built
showing all required setbacks for 15
Brayton Lane. Bob, I should not have to
wait 7 months for a certified septic as-built
when it should be submitted within a week
after the system is installed. Please submit
the certified septic system as-built to my
attention asap! Your attention to this matter
is imperative in order to close out the
permit.
Thank You!
John O'Brien
Director of Building and Code Enforcement
Town of Queensbury
No
Roof gutters don't discharge
over leach field
Yes
Soil Type: Sand Yes
Type of Water: Municipal / Well
Water
Well water Yes
Waterline separation distance Yes
Well separation distance Yes
Absorbtion Fields: Total Length 2 laterals at 32' each, 64' total Yes
Septic system field above
flood plain
Yes
Sump pump not connected to
septic system
Yes
Length of Each Trench 2 laterals at 32' each, 64' total Yes
Depth of Trenches 14/16"Yes
System Use Status System approved for use Yes
Building to Tank 4" schedule 40 connected to existing cast
iron pipe
Yes
Tank to Distribution Box 4" schedule 40 Yes
Distribution box to Field / Pit 4" SDR 35 to eljen mats Yes
Opening Sealed:Yes
End Cap Yes
InletOutlet Pipes & Baffles Filter at outlet side of septic tank Yes
August 01, 2023 Page 3 of 6
Septic Alteration
Septic Disposal-Residential
Issued
11/21/2022
01/23/2024
01/23/2023
15 Brayton Ln
Lake George, NY 12845
Address:
Expiration Date:
Issue Date:
Application Date:
Status:
Work Class:
Permit Type:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
Inlet & Outlet manholes 12"+
below grade
Provide access riser at inlet side of septic
tank
No
[Provide extension collar if
Yes]
Provide access riser at inlet side of septic
tank
No
Locations / Separations Yes
Foundation to Tank No
Foundation to Absorption No
Size of tank 1000 gallon septic tank Yes
Conforms as per Plot Plan Yes
Engineer Report and As-Built Provide as built drawing from design
engineer
No
Location of system on
property
Septic tank is in back yard, absorption field
is in side yard near holly lane
Yes
NOTES Created By TEXT Created Date
Kate Deck scheduled with Andy at the B&C window 01/24/2023
08/08/2023 Septic SEP-026952-2023 Scheduled John O'Brien Incomplete
August 01, 2023 Page 4 of 6
Septic Alteration
Septic Disposal-Residential
Issued
11/21/2022
01/23/2024
01/23/2023
15 Brayton Ln
Lake George, NY 12845
Address:
Expiration Date:
Issue Date:
Application Date:
Status:
Work Class:
Permit Type:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
COMMENTS PassedChecklist Item
Building Inspector Notes 1/25/23 partial approval for replacement
septic system.
A new 1000 gallon septic tank is gravity
fed to a new precast D box and an
absorption field of eljen mats. Two laterals
at 32' feet each.
- access riser at inlet side of septic tank is
required.
- provide as built drawing from design
engineer.
8/1/23
Bob,
I left messages on your phone but you
have yet to reply. Please forward to my
attention the certified septic system as-built
showing all required setbacks for 15
Brayton Lane. Bob, I should not have to
wait 7 months for a certified septic as-built
when it should be submitted within a week
after the system is installed. Please submit
the certified septic system as-built to my
attention asap! Your attention to this matter
is imperative in order to close out the
permit.
Thank You!
John O'Brien
Director of Building and Code Enforcement
Town of Queensbury
No
Roof gutters don't discharge
over leach field
Yes
Soil Type: Sand Yes
Type of Water: Municipal / Well
Water
Well water Yes
Waterline separation distance Yes
Well separation distance Yes
Absorbtion Fields: Total Length 2 laterals at 32' each, 64' total Yes
Septic system field above
flood plain
Yes
Sump pump not connected to
septic system
Yes
Length of Each Trench 2 laterals at 32' each, 64' total Yes
Depth of Trenches 14/16"Yes
System Use Status System approved for use Yes
Building to Tank 4" schedule 40 connected to existing cast
iron pipe
Yes
Tank to Distribution Box 4" schedule 40 Yes
Distribution box to Field / Pit 4" SDR 35 to eljen mats Yes
Opening Sealed:Yes
End Cap Yes
InletOutlet Pipes & Baffles Filter at outlet side of septic tank Yes
August 01, 2023 Page 5 of 6
Septic Alteration
Septic Disposal-Residential
Issued
11/21/2022
01/23/2024
01/23/2023
15 Brayton Ln
Lake George, NY 12845
Address:
Expiration Date:
Issue Date:
Application Date:
Status:
Work Class:
Permit Type:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
Inlet & Outlet manholes 12"+
below grade
Provide access riser at inlet side of septic
tank
No
[Provide extension collar if
Yes]
Provide access riser at inlet side of septic
tank
No
Locations / Separations Yes
Foundation to Tank No
Foundation to Absorption No
Size of tank 1000 gallon septic tank Yes
Conforms as per Plot Plan Yes
Engineer Report and As-Built Provide as built drawing from design
engineer
No
Location of system on
property
Septic tank is in back yard, absorption field
is in side yard near holly lane
Yes
NOTES Created By TEXT Created Date
Kate Deck scheduled with Andy at the B&C window 01/24/2023
August 01, 2023 Page 6 of 6