IM Inspection Worksheet_01-08-2023_13-20-54INSPECTION WORKSHEET (FDTN-026912-2023)
RC-0296-2023Case Number:Case Module:Permit Management
08/01/2023 Partial PassInspection Status:Inspection Date:
Building FoundationInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:98 West Mountain Rd
Queensbury, NY 12804
315.6-1-18
Company Name NameContact Type
Applicant CERRONE BUILDERS, INC.
Contractor CERRONE BUILDERS, INC.
Engineer Vision Engineering
Granted Permission CERRONE BUILDERS, INC.
Primary Owner CERRONE BUILDERS, INC.
Checklist Item CommentsPassed
Building Inspector Notes False
Footing Drain Stone - 12 inch width False
PVC/Cast/Copper/Pex tubing False
Pressure Test False
Foundation / Wallpour False
5 psi or 10 ft. above highest conn. for 15 minutes False
Masonry Wall False
Air or head test False
Footing Drain Stone - 6 inches above footing False
Foundation Dampproofing False
Plumbing Under Slab False
Foundation Waterproofing False
Footing Drain Daylight or Sump False
Footings True
Footing Drain stone - 6 mil poly False
Piers True
Backfill Approval False
Rough Grade 6 inch drop within 10 ft.False
Foundation Insulation Interior / Exterior False
Reinforcement in Place True 2 rows # 4...
Reinforcement in Place False
Permit Card Visible From Road True
Poly Under Slab False
Footing Dowels or Keyway in place False
August 01, 2023 Page 1 of 1