IM Inspection Worksheet_03-08-2023_14-33-56INSPECTION WORKSHEET (FDTN-026995-2023)
RC-0821-2021Case Number:Case Module:Permit Management
08/03/2023 PassedInspection Status:Inspection Date:
Building FoundationInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:113 Seelye Rd
Queensbury, NY 12804
227.17-1-49
Company Name NameContact Type
Applicant Michael Kajdasz
Architect Curtis Dybas
Engineer Hutchins Engineering
Granted Permission Michael Kajdasz
Primary Owner Susan Kajdasz
Michael Kajdasz
Checklist Item CommentsPassed
Building Inspector Notes True Not completed, call for recheck when ready
Verified 12/29/22
8/3/23 verified foam board / poly and wire mesh prior to garage
slab pour
Foundation / Wallpour True
Footings True Complete forms provide chairs or tie off bar, not completed
Verified 12/29/22 with 2 rows #4 continuous
Backfill Approval False
Rough Grade 6 inch drop within 10 ft.False
Foundation Insulation Interior / Exterior True
Reinforcement in Place True With 2 rows # 4 horizontally
Permit Card Visible From Road True
Poly Under Slab True
Footing Dowels or Keyway in place True