IM Inspection Worksheet_03-08-2023_14-47-39 Illl 111 Illl llllllll llllll41111111111111111 IIIIIII llllllllll1111111111111111111 fill���� IIIII lull Illl llllllll���1�1 ll`1�111111111 IIII IIIII IIIIIIUUUIII IIIIIIIIIIIIIIIIIIIIIIIIllll4l UIIIIIIIIIIII Illlllllllllllll IIIIIU IIIIIIIIIIIIIIIIIIIIIIII IIII IIIII IIII IIII IIII fill 11111 111 IIIII fill ��� 111�111 l III II U I IIIII 1 l ll l� � I I II I l II II II I I II Il lull � II �l 111�1 r
Case Number: RC-0056-2022 Case Module: Permit Management
Inspection Date: 08/03/2023 Inspection Status: Failed
Inspector: Mark Smith Inspection Type: Residential Final Inspection
Job Address: 1481 Bay Rd Parcel Number: 265.-1-21.2
Lake George, NY 12845
Contact Type Company Name Name
Applicant Jesse Stevenson
Concrete Contractor Ottens Concrete
Contractor Ottens Concrete
Engineer Infinite Engineering Solutions
Granted Permission Jesse Stevenson
Primary Owner Jesse Stevenson
Checklist Item Passed Comments
bedroom(s)with gas appliances False
Low flow toilet 1.3 gal/flushing cycle False
Bathroom Fans, if no window False
3" Plumbing Vent through roof minimum 18 inch False
Grade away from foundation: 6"down, 10'out False
Final Survey Plot Plan False
Sewer Dept. Inspection Sticker False
Window guards req:<2' above floor/6' above grade False
Interior privacy/trim/doors/main entrance 36 False
Backflow Preventors where required False
Basement wall insulation R-value verified False
Emergency egress below grade False
Fuel Tanks above flood plain elevation False
Intake Openings False
Safety glazing: w/in 5'of tub/shower False
Site Plan/Variance required False
Seals on Garage Doors, esp. Wood False
Not less than 3' horiz from opening of bthrn False
Basement ceiling covered 2x8 fl joist or less False
Attic Access Insulation =Attic R-Value False
Gas Shut-off Exposed & Regulator 12" min abv grd False
Platform at all exterior doors False
Fireblocking at fl joist 80 s.f. or less False
Garage Floor Pitched False
Buried Fuel Tanks anchored in flood zone False
Wood deck: 2'+from grade dia bracing required False
Inter Connected False
Arc Fault Breaker Habitable Spaces False
August 03,2023 Page 1 of 4
IIII 111 Illl llllllll 1l�lllll IIIIIIIIIIIIIII IIIIIII llllllllllllllllllll IIIllllll fill���� IIIII lull fill llllllll���11�11``11�IIIIIIII fill IIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII lllllllllllll4l IIIIIIIIIIIIIII Illlllllllllllll IIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIII IIIII IIII IIII IIII fill 11111 111 IIIII Illl ��� 11 �11 II lIII4 UI IIIII 1llll� l � III Il II IIII II IIIllllll � IIIl111��r
Checklist Item Passed Comments
Dryer Duct Max Length 35', Labeled Over 35' False
Energy Sticker on Elec. Panel:R-Val. &Heating Sys False
Furnace/Hot Water Heater operating False
Hot water drain pan to indirect waste False
Fresh Air Intake False
Chimney Rain Cap Installed False
Basement stairs closed rise greater than 4 inches False
Foam in basement/attics covered w/thermal barrier False
Outside every bedroom area False
Oil Furnace Shut-Off at Entrance to Furnace Area False
Blower Door Test Certification False
Fin Elect; Energy Saving Light Bulbs 90 Percent False
Heat detector in garage False
Gas Log In Sealed or Glass Enclosure False
OK to Issue C/O False
Truss ID Signage Installed at Electrical Meter False
Range Hood 400+ cfm-Fresh Air REQUIRED False
4 inch Building Number Address visible from road False
CO in bedrooms w/gas appliances False
HVAC Vent Terminal 10'from Lot Line&Openings False
Attic Access Gasketed False
Jack posts in basement lagged at top and bottom False
Flood Plain Certification, if required False
Deck Ledger-Bolted per Code False
HRV or ERV Installed per Bedroom Requirements False
Floor truss, draft stop-fin base 1,000 sq. ft. False
Low water shut-off boiler False
Roof Complete/Exterior Finish Complete False
Crawl space/knee wall access insulated &gasketed False
1/2" Gypsum or House Wall and Gable False
August 03,2023 Page 2 of 4
IIII 111 Illl llllllll 1l�lllll IIIIIIIIIIIIIII IIIIIII llllllllllllllllllll IIIllllll fill���� IIIII lull fill llllllll���11�11``11�IIIIIIII fill IIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII lllllllllllll4l IIIIIIIIIIIIIII Illlllllllllllll IIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIII IIIII IIII IIII IIII fill 11111 111 IIIII Illl ��� 11 �11 II lIII4 UI IIIII 1llll� l � III Il II IIII II IIIllllll � IIIl111��r
Checklist Item Passed Comments
General Comments False 8/3/23 final residential inspection not approved, please address
the items listed below and call for recheck.
- provide an updated manual S &J showing the change to geo
thermal heating and cooling equipment.
- provide third party sign off for installation of geo thermal heating
system
-a final inspection by the Fire Marshal for the wood burning stove
is required
-condensate line can not drain into the floor drain in basement.
-thermostat needs installed in main house.
-provide blower door test results.
-provide proof of final electrical inspection.
-basement ceiling will need to be sheet rocked or an approved
thermal barrier to cover insulation.
complete exterior trim, siding, and soffits.
complete interior trim, installation of doors, and work at upstairs
bathroom.
-ridged insulation at exterior of foundation will need to be covered
or cut below grade.
-A final inspection by Code Compliance Officer Bruce frank will be
req u i red.
Guard at stairwell at 34"or more False
Bathroom/Kitchen Watertight False
Battery backup False
Every level, Every bedroom False
Knee wall/Crawl space 18"x 24" False
6" clearance to sill plate False
Attic Access 22 x 30 minimum False
Chimney Height/B Vent/Direct Vent Location False
Electronic as-builts False
5/8"Type X with Living Space Above False
Flex Gas Pipe Bonding False
Outside Spigots have Air Gap False
Carbon Monoxide Detectors: False
OK to Issue Temporary C/O False
All Hot Water Systems: 3/4"or larger piping R-3 False
Plumbing fixtures False
Handrail or more risers False
Guard at deck, porches 36" or more False
20 Minute Fire Door/Self-Closing Hardware False
Basement Egress: 5s.f. window w/sill or Bilco door False
Foundation insulation to floor False
on all levels w/gas appliances (i.e. furnace) False
Relief Valve ,Heat Trap/Water Temp 110 deg or less False
Fresh air supply 3'from grade False
Propane Tank: Proper Setback from Prop Line/Struct False
Pull down stairs boxed out and insulated False
Duct work sealed properly False
Guards at stairs,decks,patios 30" + above grade False
August 03,2023 Page 3 of 4
IIII 111 Illl llllllll 1l�lllll IIIIIIIIIIIIIII IIIIIII llllllllllllllllllll IIIllllll fill���� IIIII lull fill llllllll���11�11``11�IIIIIIII fill IIIII IIIIIIIIIIIIIII IIIIIIIIIIIIIII lllllllllllll4l IIIIIIIIIIIIIII Illlllllllllllll IIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIII IIIII IIII IIII IIII fill 11111 111 IIIII Illl ��� 11 �11 II lIII4 UI IIIII 1llll� l � III Il II IIII II IIIllllll � IIIl111��r
Checklist Item Passed Comments
Furnace shut-off w/in 30 ft. or w/in line of site False
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/FI. Truss False
4+ Deck Joist Ledger Connections-24"From Ends False
Smoke Detectors: False
within 10'of all sleeping areas False
As Built Septic System_ False
Interior/Exterior Railings 34 to 38 False
CSST/other piping in conduit if buried,if required False
Encl. Stairs Sheetrock Underside minimum 'h Gypsurr False
Handrail Termination at Newell Post or Wall False
August 03,2023 Page 4 of 4