IM Inspection Worksheet_04-08-2023_12-06-35INSPECTION WORKSHEET (RESFINAL-027011-2023)
RC-0437-2023Case Number:Case Module:Permit Management
08/04/2023 Partial PassInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:35 Essex Ct
Queensbury, NY 12804
308.19-2-10
Company Name NameContact Type
Applicant Lisa Benton
Granted Permission GEORGE BENTON JR
Primary Owner GEORGE BENTON JR
Checklist Item CommentsPassed
bedroom(s) with gas appliances False
Low flow toilet 1.3 gal/flushing cycle False
Bathroom Fans, if no window False
3" Plumbing Vent through roof minimum 18 inch False
Grade away from foundation: 6" down, 10' out False
Final Survey Plot Plan False
Sewer Dept. Inspection Sticker False
Window guards req:<2' above floor/6' above grade False
Interior privacy/trim/doors/main entrance 36 False
Backflow Preventors where required False
Basement wall insulation R- value verified False
Emergency egress below grade False
Fuel Tanks above flood plain elevation False
Intake Openings False
Safety glazing: w/in 5' of tub/shower False
Site Plan / Variance required False
Seals on Garage Doors, esp. Wood False
Not less than 3' horiz from opening of bthrn False
Basement ceiling covered 2x8 fl joist or less False
Attic Access Insulation = Attic R- Value False
Gas Shut-off Exposed & Regulator 12" min abv grd False
Platform at all exterior doors False
Fireblocking at fl joist 80 s.f. or less False
Garage Floor Pitched False
Buried Fuel Tanks anchored in flood zone False
Wood deck: 2'+ from grade dia bracing required False
Inter Connected False
Arc Fault Breaker Habitable Spaces False
Dryer Duct Max Length 35', Labeled Over 35'False
Energy Sticker on Elec. Panel:R-Val. & Heating Sys False
Furnace/Hot Water Heater operating False
Hot water drain pan to indirect waste False
August 04, 2023 Page 1 of 3
INSPECTION WORKSHEET (RESFINAL-027011-2023)
Checklist Item CommentsPassed
Fresh Air Intake False
Chimney Rain Cap Installed False
Basement stairs closed rise greater than 4 inches False
Foam in basement/attics covered w/thermal barrier False
Outside every bedroom area False
Oil Furnace Shut-Off at Entrance to Furnace Area False
Blower Door Test Certification False
Fin Elect; Energy Saving Light Bulbs 90 Percent False
Heat detector in garage False
Gas Log In Sealed or Glass Enclosure False
OK to Issue C/O False
Truss ID Signage Installed at Electrical Meter False
Range Hood 400+ cfm-Fresh Air REQUIRED False
4 inch Building Number Address visible from road False
CO in bedrooms w/gas appliances False
HVAC Vent Terminal 10' from Lot Line & Openings False
Attic Access Gasketed False
Jack posts in basement lagged at top and bottom False
Flood Plain Certification, if required False
Duct work sealed properly False
OK to Issue Temporary C/O False
Furnace shut-off w/in 30 ft. or w/in line of site False
on all levels w/gas appliances (i.e. furnace)False
20 Minute Fire Door/Self-Closing Hardware False
Floor truss, draft stop- fin base 1,000 sq. ft.False
Attic Access 22 x 30 minimum False
Electronic as-builts False
Guard at stairwell at 34" or more False
6" clearance to sill plate False
Handrail 4 or more risers False
Plumbing fixtures False
Propane Tank: Proper Setback from Prop Line/Struct False
Guard at deck, porches 36" or more False
Fresh air supply 3' from grade False
Handrail Termination at Newell Post or Wall False
Pull down stairs boxed out and insulated False
within 10' of all sleeping areas False
Chimney Height / B Vent / Direct Vent Location False
CSST/other piping in conduit if buried,if required False
Every level, Every bedroom False
As Built Septic System False
Encl. Stairs Sheetrock Underside minimum ½ Gypsum False
August 04, 2023 Page 2 of 3
INSPECTION WORKSHEET (RESFINAL-027011-2023)
Checklist Item CommentsPassed
Flex Gas Pipe Bonding False
Roof Complete / Exterior Finish Complete False
Basement Egress: 5s.f. window w/sill or Bilco door False
Deck Ledger-Bolted per Code False
All Hot Water Systems: 3/4" or larger piping R-3 False
5/8" Type X with Living Space Above False
Knee wall/Crawl space 18" x 24"False
Bathroom / Kitchen Watertight False
Foundation insulation to floor False
General Comments True permit has been issued for egress window / basement finished
off without permit process so now egress window to be added,
please call when ready to verify
Carbon Monoxide Detectors:False
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss False
Guards at stairs,decks,patios 30" + above grade False
Outside Spigots have Air Gap False
1/2" Gypsum or House Wall and Gable False
4+ Deck Joist Ledger Connections-24" From Ends False
Interior/Exterior Railings 34 to 38 False
Crawl space/knee wall access insulated & gasketed False
HRV or ERV Installed per Bedroom Requirements False
Battery backup False
Smoke Detectors:False
Relief Valve ,Heat Trap/Water Temp 110 deg or less False
Low water shut-off boiler False