IM Inspection Worksheet_09-08-2023_14-36-09INSPECTION WORKSHEET (RESFINAL-027108-2023) RC-0056-2022Case Number:Case Module:Permit Management 08/09/2023 Partial PassInspection Status:Inspection Date: Residential Final InspectionInspection Type:Inspector:Mark Smith Job Address:Parcel Number:1481 Bay Rd Lake George, NY 12845 265.-1-21.2 Company Name NameContact Type Applicant Jesse Stevenson Concrete Contractor Ottens Concrete Contractor Ottens Concrete Engineer Infinite Engineering Solutions Granted Permission Jesse Stevenson Primary Owner Jesse Stevenson Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle True Bathroom Fans, if no window True 3" Plumbing Vent through roof minimum 18 inch True Grade away from foundation: 6" down, 10' out False complete site work Final Survey Plot Plan False Sewer Dept. Inspection Sticker False Window guards req:<2' above floor/6' above grade True Interior privacy/trim/doors/main entrance 36 True Basement wall insulation R- value verified False Emergency egress below grade True walk out basement Fuel Tanks above flood plain elevation False Site Plan / Variance required False Seals on Garage Doors, esp. Wood False Not less than 3' horiz from opening of bthrn True Basement ceiling covered 2x8 fl joist or less False Gas Shut-off Exposed & Regulator 12" min abv grd True Platform at all exterior doors True Fireblocking at fl joist 80 s.f. or less False Garage Floor Pitched False Buried Fuel Tanks anchored in flood zone False Wood deck: 2'+ from grade dia bracing required True Inter Connected True Arc Fault Breaker Habitable Spaces False Dryer Duct Max Length 35', Labeled Over 35'False Furnace/Hot Water Heater operating False Hot water drain pan to indirect waste False Fresh Air Intake True Basement stairs closed rise greater than 4 inches False August 09, 2023 Page 1 of 3 INSPECTION WORKSHEET (RESFINAL-027108-2023) Checklist Item CommentsPassed Outside every bedroom area True Oil Furnace Shut-Off at Entrance to Furnace Area False Blower Door Test Certification True Fin Elect; Energy Saving Light Bulbs 90 Percent False Gas Log In Sealed or Glass Enclosure False OK to Issue C/O False Truss ID Signage Installed at Electrical Meter False 4 inch Building Number Address visible from road True Jack posts in basement lagged at top and bottom False Flood Plain Certification, if required False Guard at deck, porches 36" or more True 6" clearance to sill plate True 5/8" Type X with Living Space Above False Propane Tank: Proper Setback from Prop Line/Struct False 4+ Deck Joist Ledger Connections-24" From Ends True 20 Minute Fire Door/Self-Closing Hardware False Every level, Every bedroom True Furnace shut-off w/in 30 ft. or w/in line of site False within 10' of all sleeping areas True on all levels w/gas appliances (i.e. furnace)True Relief Valve ,Heat Trap/Water Temp 110 deg or less False Electronic as-builts False 1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss False Smoke Detectors:True Guards at stairs,decks,patios 30" + above grade True Battery backup True As Built Septic System False Deck Ledger-Bolted per Code True Foundation insulation to floor True CSST/other piping in conduit if buried,if required False Plumbing fixtures False complete work at upstairs bathroom Low water shut-off boiler False Bathroom / Kitchen Watertight False complete up stairs bathroom Fresh air supply 3' from grade True Duct work sealed properly True All Hot Water Systems: 3/4" or larger piping R-3 True 1/2" Gypsum or House Wall and Gable False OK to Issue Temporary C/O False Outside Spigots have Air Gap True Handrail Termination at Newell Post or Wall True Flex Gas Pipe Bonding False HRV or ERV Installed per Bedroom Requirements True August 09, 2023 Page 2 of 3 INSPECTION WORKSHEET (RESFINAL-027108-2023) Checklist Item CommentsPassed Carbon Monoxide Detectors:True Interior/Exterior Railings 34 to 38 True Roof Complete / Exterior Finish Complete False complete exterior siding and trim General Comments False 8/3/23 final residential inspection not approved, please address the items listed below and call for recheck. - provide an updated manual S & J showing the change to geo thermal heating and cooling equipment. - provide third party sign off for installation of geo thermal heating system -a final inspection by the Fire Marshal for the wood burning stove is required -condensate line can not drain into the floor drain in basement. -thermostat needs installed in main house. -provide blower door test results. -provide proof of final electrical inspection. -basement ceiling will need to be sheet rocked or an approved thermal barrier to cover insulation. complete exterior trim, siding, and soffits. complete interior trim, installation of doors, and work at upstairs bathroom. -ridged insulation at exterior of foundation will need to be covered or cut below grade. - A final inspection by Code Compliance Officer Bruce frank will be required. 8/9/23 partial approval for final inspection. -Approved for temporary certificate of occupancy only. complete the items listed below for final approval - provide a updated manual S&J showing the change to geo thermal heating and cooling system - Provide third party sign off of installation of geo thermal systems, - condensate line cannot drain in to floor drain in basement. - install thermostats in there permanent locations. - Basement ceiling will need to be sheet rocked or have an approved 20 minute thermal barrier installed to cover the insulation. - Complete exterior trim siding and soffits. - complete interior trim, install doors, work in up stairs bath room, install permanent guards at stairs and loft at second floor. - ridged insulation at exterior foundation will need to be covered or cut below grade. - final approval from Code Compliance Officer Bruce Frank Handrail 4 or more risers True Encl. Stairs Sheetrock Underside minimum ½ Gypsum False Basement Egress: 5s.f. window w/sill or Bilco door False Guard at stairwell at 34" or more True August 09, 2023 Page 3 of 3