1986-246 BUILDING PERMIT
TOWN OF QUEENSBURY 86-246
No.
WARREN COUNTY, NEW YORK
PERMISSION is hereby granted to Charles McNulty
OWNER of property located at 14 Twicwood Lane Street. Road or Ave.
SewageAl terat ion in the Town of Queensbury,To Construct or place a
m
at the above location in accordance to application together with plot plans and other information hereto filed and
approved and in compliance with the Town of Queensbury Building and Zoning Ordinance.
1. OWNER'S Address is 14 Twicwood Lane
4
Glens Falls, New York
2. CONTRACTOR or BUILDERS Name
Sanitary Sewer Service
F-
F
3. CONTRACTOR or BUILDERS Address
P.O. Box 224 H.
Glens Falls, New York
4. ARCHITECT'S Name
0
0
5. ARCHITECTS Address
B. TYPE of Construction—(Please indicate by XI
N
N
( )Wood Frame ( 1 Masonry ( 1 Steel ( 1
N
w
m
7. PLANS and Specifications
No. 1 dis[. box, 2 6'x8' drywells 24" #3 stone per plot and n
application submitted.
8. Proposed Use w
q
Sewage system for dwelling
$ 10.00 PERMIT FEE PAID—THIS PERMIT EXPIRES May 19 19 88
Of a longer period is required an application for an extension must be made to the Building and Zoning inspector of the
town of Queensbury before the expiration date.)
Dated at the Town of Queensbury this �1y9tth Day of May 19 86
SIGNED BY 2laclD a • Fe for the Town of Queensbury
Building and Zoning Inspector
37a,� _awn o` Quee„d6ury
BUILDING and ZONING DEPARTMENT fT�OWN OF QUEENSRU-"'
Bay and Haviland Road, R.D. 1 Box 98 { iE V E Ii V E
Oueensbury, New York 12801 i1J1511! �J
MNI1.. J1_9•8�`
A.M. /Oct.. • txPl ' P.M.
SEPTIC DISPOSAL PERMIT APPLICATION ?I81911042)
1I2I3I4I6I8
Owner's Name ��A/eI ��- / r c .vl� �/ (, T7 Tel. /p ) - yd-27
Address /4/ -(.0 I C W 0 o i) t4t 1�
Person/Firm installing system SAAJI7-14/Ly crrL v f(KV/cC
Number of bedrooms (residential only) 3 /
Total daily flow: (compute @ 150 cal.per bedroom per day) i'sc
Topography: flat)- rolling - steep - (circle one) Decree of slope 8
Nature of soils: 41, loam-clay- other- Depth ft.
Ground water-- at what depth? ft.
Bedrock or impervious material--at what depth? — ft.
Percolation Test Not recuired ,9• Required -Rate min/inch.
Domestic Water Supply - Municipal Well - Other
IMPORTANT!
On a separate piece of paper, submit a diagram of the proposed septic
system with all dimensions; including distance from any structure,
distance from property lines and distances from aj domestic water
supply or shore-line of lake, stream, pond or wetlands. Include all
dimensions of the system itself.
Description of proposed system:
Septic tank size/060 gal .
Tile field- Lengt of each trench ft. Total field ft.
Size of stone I --
Seepage Pit (s) Number._/ Size Cs., ftX D a ft. Size of stone% 3
Any contractor, corporation, individual,Etc. , engaged in the
construction of a Sanitary Sewage Disposal System, who covers the
same before inspection, does not have an approved Permit, or varies
from the approved application, will be subject to a Penalty of $250
as provided for in Section 6. 010 of the Town of Queensbury Sanitary
Sewage Ordinance. /
c 6 'y/ ' At cc' KJ
a -A-e av <, 3 is/ Sc
Signature of Applicant S71)e-fiC
Date
01/86 and/vl
Septic System Inspections:
A. All applications for septic system installation,
alteration or repair, as reouired by the Town of
Oueensbury Sanitary Sewage Ordinance, shall be
submitted to the Buildina Department at least
24 hours before start of construction and shall
include a plot plan showing:
1) the proposed location of the system
2) location and distance to lot lines
3) location and distance to structures
4) location and distance to any water supply
5) size and dimensions of all tanks, distribution
boxes, tile fields and/or drywalls
B. No system shall be covered before inspection and
approval by the Building Inspector. Failure to
comply with this requirement may result in the
uncovering of the system by the ,installer and a
fine of up to $250.00.
C. An approved copy of the plot plan shall he
available•on the construction site. Failure
to produce said plot plan at time of inspection
may result in an immediate work stoppage.
D. Should unforeseen problems during construction
prevent proper installation, alteration or
repair of an approved system, a new proposal
must be submitted to the Oueensbury Building
Department before further construction.
DO -/,'3D
TOWN OF QUEENSBURY
Building Department �
Impactors Report Date .5-`/�` p(
Nana Tht fttu
Location 71v/t . (iv)
Permmi N . VG- -t-'�G Weather
Remarks
Excaiation
Footing Forms
Footing & Piers
Foundation
Cement Coat
Waterproofing
Backfill
Final Survey Framing
Sheathing
Roof Felt
Roofing
Siding
Masonry Veneer
Rough Plbg.
Relief Valves
Wall Board
Ext. Porches Finished Floor
Interior Trim
Stairs 9 Railings
Cellar Dr. Tile
Concrete Floors
Plbg. Fixtures
Car. Fireproofing
Door Closers
Chimney
Water Meter Inst.
Septic Approval ....—fl,s‹.
Floors
Insulation Foundation,
Walls
Ceiling
Building Inspector
REMARKS