IM Inspection Worksheet_18-08-2023_13-36-29INSPECTION WORKSHEET (RPLUM-027280-2023)
CC-0161-2023Case Number:Case Module:Permit Management
08/18/2023 Partial PassInspection Status:Inspection Date:
Rough PlumbingInspection Type:Inspector:Mark Smith
Job Address:Parcel Number:1172 State Rte 9
Queensbury, NY 12804
288.20-1-20
Company Name NameContact Type
Applicant GREAT ESCAPE THEME PARK LP
Engineer Haanen Engineering
Granted Permission GREAT ESCAPE THEME PARK LP
Primary Owner GREAT ESCAPE THEME PARK LP
Checklist Item CommentsPassed
Building Inspector Notes False 5/31/23 partial approval for rough plumbing
- plumbing for sanitary drains and vents under slab approved.
8/18/23 partial approval for rough plumbing.
-pluming for domestic water supply approved.
sanitary drains and vents approved.
Pressure Test True
Pressure Test True
3" Vent Through Roof - 18" min False vent at gable must be 3"
5 psi or 10 ft. above highest conn. for 15 minutes True sanitary drains andvents tested with water head test
Water Supply Piping True
Plumbing Vent Vents in Place False
Air Head True
50 P.S.I for 15 minutes True
Drain Vent True
Permit Card Visible From Road True
August 18, 2023 Page 1 of 1