Loading...
IM Inspection Worksheet_25-08-2023_14-02-51INSPECTION WORKSHEET (SEP-027427-2023) SEP-0690-2022Case Number:Case Module:Permit Management 08/25/2023 Partial PassInspection Status:Inspection Date: SepticInspection Type:Inspector:Mark Smith Job Address:Parcel Number:20 Burnt Ridge Rd Lake George, NY 12845 239.16-1-19 Company Name NameContact Type Applicant Environmental Design Partnership (EDP) Contractor Moss Capital Group LLC Engineer Environmental Design Partnership (EDP) Granted Permission DAN SLOTE Primary Owner DAN SLOTE Checklist Item CommentsPassed Building Inspector Notes False 8/25/23 partial approval for septic system. -placement of 1250 gallon poly septic tank verified -placement of 1000 gallon pump tank verified.. - placement of 20' x30' raised absorption bed verified. 2' forced main from pump tank verified. items remaining - verify baffles at septic tank. -verify alarm and pump floats at pump tank. - verify grinder pump and alarms at grinder pump are operational. -provide proof of final electrical inspection. -provide final as built drawing from design engineer. - verify final grading at raised bed. Soil Type: Sand False ETU Maintenance Contract provided False Size of Stone False Final Electrical False Roof gutters don't discharge over leach field False Waterline separation distance False Building to Tank False Public Sewer Sign-Off False [Provide extension collar if Yes]False Tank to Distribution Box False Size False Opening Sealed:False Soil Type: Clay False 90% alarm level activates False End Cap False Absorbtion Fields: Total Length False Septic system field above flood plain False Foundation to Tank False Engineer Report and As-Built False Sump pump not connected to septic system False August 25, 2023 Page 1 of 2 INSPECTION WORKSHEET (SEP-027427-2023) Checklist Item CommentsPassed Water shut off activates at 90% full False Well Casing Length: 50ft +/-False Location of system on property False Inlet & Outlet manholes 12"+ below grade False Septic tanks & pump station anchored in flood zone False Water softener not connected to septic system False Type of Water: Municipal / Well Water False Locations / Separations False Well separation distance False Depth of Trenches False Separation of Pits False Stone Size:False Seepage Pits: Number False Length of Each Trench False System Use Status False Conforms as per Plot Plan False Size of tank False Distribution box to Field / Pit False Foundation to Absorption False InletOutlet Pipes & Baffles False 50% alarm level activates False Soil Type: Loam False August 25, 2023 Page 2 of 2