IM Inspection Worksheet_05-09-2023_10-37-05INSPECTION WORKSHEET (RESFINAL-027385-2023)
RC-0395-2022Case Number:Case Module:Permit Management
09/05/2023 PassedInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:11 Nacy Rd
Lake George, NY 12845
289.6-1-18
Company Name NameContact Type
Applicant Guy DiMemmo
Contractor Reece Rudolph
Granted Permission Guy DiMemmo
Primary Owner Guy DiMemmo
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle True
Bathroom Fans, if no window True
3" Plumbing Vent through roof minimum 18 inch False existing vent stack
Grade away from foundation: 6" down, 10' out True
Final Survey Plot Plan True
Interior privacy/trim/doors/main entrance 36 True
Emergency egress below grade True
Intake Openings True
Gas Shut-off Exposed & Regulator 12" min abv grd False propane
Platform at all exterior doors True
Inter Connected True
Arc Fault Breaker Habitable Spaces True
Furnace/Hot Water Heater operating True
Fresh Air Intake True
Outside every bedroom area True
Fin Elect; Energy Saving Light Bulbs 90 Percent True
4 inch Building Number Address visible from road True
HVAC Vent Terminal 10' from Lot Line & Openings True
Jack posts in basement lagged at top and bottom True
Guard at deck, porches 36" or more True
Propane Tank: Proper Setback from Prop Line/Struct True
Every level, Every bedroom True
Furnace shut-off w/in 30 ft. or w/in line of site True
Chimney Height / B Vent / Direct Vent Location True
within 10' of all sleeping areas True
on all levels w/gas appliances (i.e. furnace)True
Relief Valve ,Heat Trap/Water Temp 110 deg or less True
Bathroom / Kitchen Watertight True
Duct work sealed properly True
As Built Septic System True
Outside Spigots have Air Gap True
September 05, 2023 Page 1 of 2
INSPECTION WORKSHEET (RESFINAL-027385-2023)
Checklist Item CommentsPassed
OK to Issue Temporary C/O True OK to issue Certificate of Compliance
Battery backup True
Fresh air supply 3' from grade True
Handrail 4 or more risers True
Handrail Termination at Newell Post or Wall True
Roof Complete / Exterior Finish Complete True
General Comments True for interior alterations
Smoke Detectors:True
Carbon Monoxide Detectors:True
Plumbing fixtures True
September 05, 2023 Page 2 of 2